2026-02-02 10:48:49,067 INFO Start Time: 2026-02-02 10:48:49.067157 2026-02-02 10:48:49,067 INFO [MOCK] Serial terminal initialized 2026-02-02 10:48:49,069 INFO [MOCK] Serial terminal connected 2026-02-02 10:48:49,069 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!****** 2026-02-02 10:48:49,069 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ... 2026-02-02 10:48:49,072 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts 2026-02-02 10:48:49,083 INFO tgt_gen_alone(): 0 2026-02-02 10:48:49,084 INFO tgt_gen() 2026-02-02 10:48:49,094 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 10:48:49,094 INFO TgtMsg: 0 0 2026-02-02 10:48:49,095 INFO Tgt: 1 @ 1180 2026-02-02 10:48:49,095 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 10:48:49,095 INFO OK: read value = 1 2026-02-02 10:48:49,095 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 10:48:49,095 INFO OK: read value = 1180 2026-02-02 10:48:49,095 INFO [MOCK] Log stopped 2026-02-02 10:48:49,096 INFO Repetition 1 of 3 2026-02-02 10:48:49,096 DEBUG [MOCK] Serial statistics reset 2026-02-02 10:48:49,096 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 10:48:50,096 INFO Set MAIN_POWER to False 2026-02-02 10:48:50,097 INFO [MOCK] Power OFF 2026-02-02 10:48:50,097 INFO [MOCK] 1553 Interface stopped 2026-02-02 10:48:55,097 INFO Check that MAIN_POWER is equal to 0 2026-02-02 10:48:55,098 INFO OK: read value = False 2026-02-02 10:48:59,099 INFO The test operator is required to switch on the target. 2026-02-02 10:48:59,099 INFO Set MAIN_POWER to True 2026-02-02 10:48:59,099 INFO [MOCK] Power ON 2026-02-02 10:48:59,100 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 10:48:59,100 INFO run_count = 1 2026-02-02 10:48:59,100 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 10:48:59,100 INFO current_scenario = 'mixed' 2026-02-02 10:48:59,100 INFO _scenario_list = ['normal', 'processor_fail', 'normal'] 2026-02-02 10:48:59,100 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 10:48:59,101 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='normal' 2026-02-02 10:48:59,101 INFO [DEBUG] About to call _log_scenario_info('normal', 1, 3) 2026-02-02 10:48:59,101 INFO 2026-02-02 10:48:59,102 INFO #################################################################################################### 2026-02-02 10:48:59,102 INFO #################################################################################################### 2026-02-02 10:48:59,102 INFO ### RUN 1/3: NORMAL OPERATION 2026-02-02 10:48:59,102 INFO #################################################################################################### 2026-02-02 10:48:59,103 INFO 2026-02-02 10:48:59,103 INFO SCENARIO: normal 2026-02-02 10:48:59,103 INFO DESCRIPTION: All systems operational - no failures 2026-02-02 10:48:59,103 INFO 2026-02-02 10:48:59,103 INFO EXPECTED FAILURES: 2026-02-02 10:48:59,103 INFO (none) 2026-02-02 10:48:59,104 INFO 2026-02-02 10:48:59,104 INFO EXPECTED PASSES: 2026-02-02 10:48:59,104 INFO ✓ All B6 status fields (except pedestal) 2026-02-02 10:48:59,104 INFO ✓ All B8 diagnostic fields 2026-02-02 10:48:59,104 INFO ✓ Target generation 2026-02-02 10:48:59,104 INFO 2026-02-02 10:48:59,104 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present) 2026-02-02 10:48:59,105 INFO 2026-02-02 10:48:59,105 INFO #################################################################################################### 2026-02-02 10:48:59,105 INFO #################################################################################################### 2026-02-02 10:48:59,105 INFO 2026-02-02 10:48:59,105 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 10:48:59,105 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected) 2026-02-02 10:48:59,105 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1) 2026-02-02 10:49:04,106 INFO Check that MAIN_POWER is equal to 1 2026-02-02 10:49:04,107 INFO OK: read value = True 2026-02-02 10:49:04,208 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 10:49:04,209 INFO Test terminated unexpectedly :'MockGrifoInstrumentInterface' object has no attribute 'default_timeout' 2026-02-02 10:49:04,210 INFO Stop Time: 2026-02-02 10:48:49.067157 2026-02-02 10:49:04,210 INFO Test execution time: 0:00:15.142751 2026-02-02 10:49:04,210 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3 Total Step 6: Success 6 (100.00%), Failed 0 (0.00%),