2026-02-02 14:51:12,751 INFO Start Time: 2026-02-02 14:51:12.751451 2026-02-02 14:51:12,752 INFO [MOCK] Serial terminal initialized 2026-02-02 14:51:12,752 INFO [MOCK] Serial terminal connected 2026-02-02 14:51:12,752 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!****** 2026-02-02 14:51:12,752 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ... 2026-02-02 14:51:12,752 INFO [MOCK] Simulating target acquisition: will appear after 2 scan cycles 2026-02-02 14:51:12,753 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 14:51:12,803 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 14:51:12,854 INFO [MOCK] Target simulated at distance 1180 2026-02-02 14:51:12,854 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts 2026-02-02 14:51:12,854 INFO tgt_gen_alone(): 0 2026-02-02 14:51:12,855 INFO tgt_gen() 2026-02-02 14:51:12,865 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 14:51:12,865 DEBUG [MOCK] Field num: 1 2026-02-02 14:51:12,865 DEBUG [MOCK] Field rng: 1180 2026-02-02 14:51:12,865 INFO TgtMsg: 0 0 2026-02-02 14:51:12,866 INFO Tgt: 1 @ 1180 2026-02-02 14:51:12,866 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 14:51:12,866 INFO OK: read value = 1 2026-02-02 14:51:12,867 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 14:51:12,867 INFO OK: read value = 1180 2026-02-02 14:51:12,867 INFO [MOCK] Log stopped 2026-02-02 14:51:12,867 INFO Repetition 1 of 2 2026-02-02 14:51:12,867 DEBUG [MOCK] Serial statistics reset 2026-02-02 14:51:12,867 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 14:51:13,868 INFO Set MAIN_POWER to False 2026-02-02 14:51:13,868 INFO [MOCK] Power OFF 2026-02-02 14:51:13,869 INFO [MOCK] 1553 Interface stopped 2026-02-02 14:51:18,870 INFO Check that MAIN_POWER is equal to 0 2026-02-02 14:51:18,870 INFO OK: read value = False 2026-02-02 14:51:22,871 INFO The test operator is required to switch on the target. 2026-02-02 14:51:22,872 INFO Set MAIN_POWER to True 2026-02-02 14:51:22,872 INFO [MOCK] Power ON 2026-02-02 14:51:22,873 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 14:51:22,873 INFO run_count = 1 2026-02-02 14:51:22,873 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 14:51:22,873 INFO current_scenario = 'mixed' 2026-02-02 14:51:22,873 INFO _scenario_list = ['sp_tests_fail', 'normal'] 2026-02-02 14:51:22,873 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 14:51:22,874 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='sp_tests_fail' 2026-02-02 14:51:22,874 INFO [DEBUG] About to call _log_scenario_info('sp_tests_fail', 1, 2) 2026-02-02 14:51:22,874 INFO 2026-02-02 14:51:22,874 INFO #################################################################################################### 2026-02-02 14:51:22,874 INFO #################################################################################################### 2026-02-02 14:51:22,875 INFO ### RUN 1/2: SIGNAL PROCESSOR TEST FAILURES 2026-02-02 14:51:22,875 INFO #################################################################################################### 2026-02-02 14:51:22,875 INFO 2026-02-02 14:51:22,875 INFO SCENARIO: sp_tests_fail 2026-02-02 14:51:22,876 INFO DESCRIPTION: Individual SP tests fail (SP1, SP2, SP3) 2026-02-02 14:51:22,876 INFO 2026-02-02 14:51:22,876 INFO EXPECTED FAILURES: 2026-02-02 14:51:22,876 INFO ✗ B8: test_sp1_timer1_up = FAIL 2026-02-02 14:51:22,877 INFO ✗ B8: test_sp2_timer_dma_pxc_if = FAIL 2026-02-02 14:51:22,877 INFO ✗ B8: test_sp3_timer_internal = FAIL 2026-02-02 14:51:22,877 INFO 2026-02-02 14:51:22,877 INFO EXPECTED PASSES: 2026-02-02 14:51:22,877 INFO ✓ B6 status fields (except processor) 2026-02-02 14:51:22,877 INFO ✓ Other B8 tests 2026-02-02 14:51:22,878 INFO 2026-02-02 14:51:22,878 INFO NOTES: Demonstrates granular test failure analysis - specific SP component failures 2026-02-02 14:51:22,878 INFO 2026-02-02 14:51:22,878 INFO #################################################################################################### 2026-02-02 14:51:22,879 INFO #################################################################################################### 2026-02-02 14:51:22,879 INFO 2026-02-02 14:51:22,879 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 14:51:22,879 INFO [MOCK APPLY] ✗ Setting processor_status = FAIL 2026-02-02 14:51:22,879 INFO [MOCK APPLY] ✗ B8 failures: SP1 (timer1_up), SP2 (timer_dma_pxc_if), SP3 (timer_internal) 2026-02-02 14:51:22,879 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1) 2026-02-02 14:51:27,880 INFO Check that MAIN_POWER is equal to 1 2026-02-02 14:51:27,881 INFO OK: read value = True 2026-02-02 14:51:27,981 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 14:51:28,182 INFO [MOCK] BIT report available after 5.3s 2026-02-02 14:51:28,204 INFO BIT report available after 0.2s 2026-02-02 14:51:28,204 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false 2026-02-02 14:51:28,204 INFO OK: read value = false 2026-02-02 14:51:28,204 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false 2026-02-02 14:51:28,205 WARNING CHECK ERROR: read value = true 2026-02-02 14:51:28,205 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:51:28,205 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status 2026-02-02 14:51:28,205 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false 2026-02-02 14:51:28,206 INFO OK: read value = false 2026-02-02 14:51:28,206 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false 2026-02-02 14:51:28,206 INFO OK: read value = false 2026-02-02 14:51:28,207 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false 2026-02-02 14:51:28,207 WARNING CHECK ERROR: read value = true 2026-02-02 14:51:28,207 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:51:28,207 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false 2026-02-02 14:51:28,207 INFO OK: read value = false 2026-02-02 14:51:28,208 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false 2026-02-02 14:51:28,208 INFO OK: read value = false 2026-02-02 14:51:28,208 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false 2026-02-02 14:51:28,208 INFO OK: read value = false 2026-02-02 14:51:28,208 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false 2026-02-02 14:51:28,208 INFO OK: read value = false 2026-02-02 14:51:28,208 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false 2026-02-02 14:51:28,208 INFO OK: read value = false 2026-02-02 14:51:28,209 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false 2026-02-02 14:51:28,209 INFO OK: read value = false 2026-02-02 14:51:28,209 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false 2026-02-02 14:51:28,209 WARNING CHECK ERROR: read value = RDR_FAIL 2026-02-02 14:51:28,209 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL 2026-02-02 14:51:28,209 WARNING Radar fail status: REAL failure (caused by: status, status) 2026-02-02 14:51:28,209 INFO [Run 1] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known 2026-02-02 14:51:28,209 INFO Known failures (HW setup): 1 2026-02-02 14:51:28,209 WARNING Real failures: status, status 2026-02-02 14:51:28,209 INFO Drill-down: Verifying all 173 B8 diagnostic fields... 2026-02-02 14:51:28,210 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false 2026-02-02 14:51:28,210 INFO OK: read value = false 2026-02-02 14:51:28,210 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false 2026-02-02 14:51:28,210 INFO OK: read value = false 2026-02-02 14:51:28,210 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false 2026-02-02 14:51:28,210 INFO OK: read value = false 2026-02-02 14:51:28,210 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false 2026-02-02 14:51:28,211 INFO OK: read value = false 2026-02-02 14:51:28,211 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false 2026-02-02 14:51:28,211 INFO OK: read value = false 2026-02-02 14:51:28,211 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false 2026-02-02 14:51:28,211 INFO OK: read value = false 2026-02-02 14:51:28,211 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false 2026-02-02 14:51:28,211 INFO OK: read value = false 2026-02-02 14:51:28,211 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false 2026-02-02 14:51:28,212 INFO OK: read value = false 2026-02-02 14:51:28,212 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false 2026-02-02 14:51:28,212 INFO OK: read value = false 2026-02-02 14:51:28,212 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false 2026-02-02 14:51:28,212 WARNING CHECK ERROR: read value = 0 2026-02-02 14:51:28,212 ERROR INTERFACE ERROR: Expected false, got 0 2026-02-02 14:51:28,212 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false 2026-02-02 14:51:28,212 INFO OK: read value = false 2026-02-02 14:51:28,212 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false 2026-02-02 14:51:28,212 INFO OK: read value = false 2026-02-02 14:51:28,213 WARNING B8_Degradation: 1/12 failures 2026-02-02 14:51:28,213 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false 2026-02-02 14:51:28,213 INFO OK: read value = false 2026-02-02 14:51:28,213 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false 2026-02-02 14:51:28,213 INFO OK: read value = false 2026-02-02 14:51:28,213 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false 2026-02-02 14:51:28,213 INFO OK: read value = false 2026-02-02 14:51:28,213 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false 2026-02-02 14:51:28,214 INFO OK: read value = false 2026-02-02 14:51:28,214 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false 2026-02-02 14:51:28,214 INFO OK: read value = false 2026-02-02 14:51:28,214 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false 2026-02-02 14:51:28,214 INFO OK: read value = false 2026-02-02 14:51:28,214 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false 2026-02-02 14:51:28,214 INFO OK: read value = false 2026-02-02 14:51:28,215 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false 2026-02-02 14:51:28,215 INFO OK: read value = false 2026-02-02 14:51:28,215 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false 2026-02-02 14:51:28,215 INFO OK: read value = false 2026-02-02 14:51:28,215 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false 2026-02-02 14:51:28,215 INFO OK: read value = false 2026-02-02 14:51:28,215 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false 2026-02-02 14:51:28,215 INFO OK: read value = false 2026-02-02 14:51:28,215 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false 2026-02-02 14:51:28,215 INFO OK: read value = false 2026-02-02 14:51:28,216 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false 2026-02-02 14:51:28,216 INFO OK: read value = false 2026-02-02 14:51:28,216 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false 2026-02-02 14:51:28,216 INFO OK: read value = false 2026-02-02 14:51:28,216 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false 2026-02-02 14:51:28,216 INFO OK: read value = false 2026-02-02 14:51:28,216 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false 2026-02-02 14:51:28,216 INFO OK: read value = false 2026-02-02 14:51:28,216 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false 2026-02-02 14:51:28,216 INFO OK: read value = false 2026-02-02 14:51:28,216 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false 2026-02-02 14:51:28,216 INFO OK: read value = false 2026-02-02 14:51:28,217 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false 2026-02-02 14:51:28,217 INFO OK: read value = false 2026-02-02 14:51:28,217 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false 2026-02-02 14:51:28,217 INFO OK: read value = false 2026-02-02 14:51:28,217 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false 2026-02-02 14:51:28,217 INFO OK: read value = false 2026-02-02 14:51:28,217 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false 2026-02-02 14:51:28,217 INFO OK: read value = false 2026-02-02 14:51:28,217 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false 2026-02-02 14:51:28,217 INFO OK: read value = false 2026-02-02 14:51:28,217 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false 2026-02-02 14:51:28,218 INFO OK: read value = false 2026-02-02 14:51:28,218 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false 2026-02-02 14:51:28,218 INFO OK: read value = false 2026-02-02 14:51:28,218 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false 2026-02-02 14:51:28,218 INFO OK: read value = false 2026-02-02 14:51:28,218 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false 2026-02-02 14:51:28,218 INFO OK: read value = false 2026-02-02 14:51:28,218 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false 2026-02-02 14:51:28,218 INFO OK: read value = false 2026-02-02 14:51:28,218 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false 2026-02-02 14:51:28,219 INFO OK: read value = false 2026-02-02 14:51:28,219 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false 2026-02-02 14:51:28,219 INFO OK: read value = false 2026-02-02 14:51:28,219 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false 2026-02-02 14:51:28,219 INFO OK: read value = false 2026-02-02 14:51:28,219 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false 2026-02-02 14:51:28,219 INFO OK: read value = false 2026-02-02 14:51:28,219 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false 2026-02-02 14:51:28,220 INFO OK: read value = false 2026-02-02 14:51:28,220 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false 2026-02-02 14:51:28,220 INFO OK: read value = false 2026-02-02 14:51:28,220 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false 2026-02-02 14:51:28,220 INFO OK: read value = false 2026-02-02 14:51:28,220 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false 2026-02-02 14:51:28,220 INFO OK: read value = false 2026-02-02 14:51:28,220 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false 2026-02-02 14:51:28,220 INFO OK: read value = false 2026-02-02 14:51:28,221 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false 2026-02-02 14:51:28,221 INFO OK: read value = false 2026-02-02 14:51:28,221 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false 2026-02-02 14:51:28,221 INFO OK: read value = false 2026-02-02 14:51:28,221 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false 2026-02-02 14:51:28,221 INFO OK: read value = false 2026-02-02 14:51:28,221 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false 2026-02-02 14:51:28,221 INFO OK: read value = false 2026-02-02 14:51:28,221 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false 2026-02-02 14:51:28,221 INFO OK: read value = false 2026-02-02 14:51:28,221 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false 2026-02-02 14:51:28,222 INFO OK: read value = false 2026-02-02 14:51:28,222 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false 2026-02-02 14:51:28,222 INFO OK: read value = false 2026-02-02 14:51:28,222 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false 2026-02-02 14:51:28,222 INFO OK: read value = false 2026-02-02 14:51:28,224 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false 2026-02-02 14:51:28,224 INFO OK: read value = false 2026-02-02 14:51:28,225 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false 2026-02-02 14:51:28,225 INFO OK: read value = false 2026-02-02 14:51:28,226 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false 2026-02-02 14:51:28,226 INFO OK: read value = false 2026-02-02 14:51:28,227 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false 2026-02-02 14:51:28,227 INFO OK: read value = false 2026-02-02 14:51:28,227 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false 2026-02-02 14:51:28,228 INFO OK: read value = false 2026-02-02 14:51:28,228 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false 2026-02-02 14:51:28,228 INFO OK: read value = false 2026-02-02 14:51:28,228 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false 2026-02-02 14:51:28,228 INFO OK: read value = false 2026-02-02 14:51:28,228 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false 2026-02-02 14:51:28,228 INFO OK: read value = false 2026-02-02 14:51:28,228 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false 2026-02-02 14:51:28,228 INFO OK: read value = false 2026-02-02 14:51:28,229 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false 2026-02-02 14:51:28,229 INFO OK: read value = false 2026-02-02 14:51:28,229 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false 2026-02-02 14:51:28,229 INFO OK: read value = false 2026-02-02 14:51:28,229 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false 2026-02-02 14:51:28,229 INFO OK: read value = false 2026-02-02 14:51:28,229 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false 2026-02-02 14:51:28,229 INFO OK: read value = false 2026-02-02 14:51:28,229 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false 2026-02-02 14:51:28,229 INFO OK: read value = false 2026-02-02 14:51:28,230 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false 2026-02-02 14:51:28,230 INFO OK: read value = false 2026-02-02 14:51:28,230 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false 2026-02-02 14:51:28,230 INFO OK: read value = false 2026-02-02 14:51:28,230 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false 2026-02-02 14:51:28,230 INFO OK: read value = false 2026-02-02 14:51:28,230 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false 2026-02-02 14:51:28,230 INFO OK: read value = false 2026-02-02 14:51:28,230 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false 2026-02-02 14:51:28,230 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false 2026-02-02 14:51:28,231 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false 2026-02-02 14:51:28,231 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false 2026-02-02 14:51:28,231 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false 2026-02-02 14:51:28,231 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false 2026-02-02 14:51:28,231 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false 2026-02-02 14:51:28,231 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false 2026-02-02 14:51:28,231 INFO OK: read value = false 2026-02-02 14:51:28,231 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false 2026-02-02 14:51:28,232 INFO OK: read value = false 2026-02-02 14:51:28,232 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false 2026-02-02 14:51:28,232 INFO OK: read value = false 2026-02-02 14:51:28,232 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false 2026-02-02 14:51:28,232 INFO OK: read value = false 2026-02-02 14:51:28,232 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false 2026-02-02 14:51:28,232 INFO OK: read value = false 2026-02-02 14:51:28,234 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false 2026-02-02 14:51:28,234 INFO OK: read value = false 2026-02-02 14:51:28,234 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false 2026-02-02 14:51:28,234 INFO OK: read value = false 2026-02-02 14:51:28,234 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false 2026-02-02 14:51:28,234 INFO OK: read value = false 2026-02-02 14:51:28,235 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false 2026-02-02 14:51:28,235 INFO OK: read value = false 2026-02-02 14:51:28,235 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false 2026-02-02 14:51:28,235 INFO OK: read value = false 2026-02-02 14:51:28,235 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false 2026-02-02 14:51:28,235 INFO OK: read value = false 2026-02-02 14:51:28,235 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false 2026-02-02 14:51:28,235 INFO OK: read value = false 2026-02-02 14:51:28,235 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false 2026-02-02 14:51:28,236 INFO OK: read value = false 2026-02-02 14:51:28,236 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false 2026-02-02 14:51:28,236 INFO OK: read value = false 2026-02-02 14:51:28,236 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false 2026-02-02 14:51:28,236 INFO OK: read value = false 2026-02-02 14:51:28,236 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false 2026-02-02 14:51:28,236 INFO OK: read value = false 2026-02-02 14:51:28,237 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false 2026-02-02 14:51:28,237 INFO OK: read value = false 2026-02-02 14:51:28,237 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false 2026-02-02 14:51:28,237 INFO OK: read value = false 2026-02-02 14:51:28,237 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false 2026-02-02 14:51:28,237 INFO OK: read value = false 2026-02-02 14:51:28,237 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false 2026-02-02 14:51:28,237 INFO OK: read value = false 2026-02-02 14:51:28,237 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false 2026-02-02 14:51:28,237 INFO OK: read value = false 2026-02-02 14:51:28,238 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false 2026-02-02 14:51:28,238 INFO OK: read value = false 2026-02-02 14:51:28,238 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false 2026-02-02 14:51:28,238 INFO OK: read value = false 2026-02-02 14:51:28,238 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false 2026-02-02 14:51:28,238 INFO OK: read value = false 2026-02-02 14:51:28,238 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false 2026-02-02 14:51:28,238 INFO OK: read value = false 2026-02-02 14:51:28,239 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false 2026-02-02 14:51:28,239 INFO OK: read value = false 2026-02-02 14:51:28,239 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false 2026-02-02 14:51:28,239 INFO OK: read value = false 2026-02-02 14:51:28,239 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false 2026-02-02 14:51:28,239 INFO OK: read value = false 2026-02-02 14:51:28,240 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false 2026-02-02 14:51:28,240 INFO OK: read value = false 2026-02-02 14:51:28,240 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false 2026-02-02 14:51:28,240 INFO OK: read value = false 2026-02-02 14:51:28,240 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false 2026-02-02 14:51:28,240 INFO OK: read value = false 2026-02-02 14:51:28,240 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false 2026-02-02 14:51:28,240 INFO OK: read value = false 2026-02-02 14:51:28,240 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false 2026-02-02 14:51:28,241 INFO OK: read value = false 2026-02-02 14:51:28,241 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false 2026-02-02 14:51:28,241 INFO OK: read value = false 2026-02-02 14:51:28,241 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false 2026-02-02 14:51:28,241 INFO OK: read value = false 2026-02-02 14:51:28,241 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false 2026-02-02 14:51:28,241 INFO OK: read value = false 2026-02-02 14:51:28,241 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false 2026-02-02 14:51:28,242 INFO OK: read value = false 2026-02-02 14:51:28,242 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false 2026-02-02 14:51:28,242 INFO OK: read value = false 2026-02-02 14:51:28,242 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false 2026-02-02 14:51:28,242 INFO OK: read value = false 2026-02-02 14:51:28,242 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false 2026-02-02 14:51:28,243 INFO OK: read value = false 2026-02-02 14:51:28,243 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false 2026-02-02 14:51:28,243 INFO OK: read value = false 2026-02-02 14:51:28,243 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false 2026-02-02 14:51:28,243 INFO OK: read value = false 2026-02-02 14:51:28,243 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false 2026-02-02 14:51:28,243 INFO OK: read value = false 2026-02-02 14:51:28,243 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false 2026-02-02 14:51:28,243 INFO OK: read value = false 2026-02-02 14:51:28,244 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false 2026-02-02 14:51:28,244 INFO OK: read value = false 2026-02-02 14:51:28,244 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false 2026-02-02 14:51:28,244 INFO OK: read value = false 2026-02-02 14:51:28,244 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false 2026-02-02 14:51:28,244 INFO OK: read value = false 2026-02-02 14:51:28,244 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false 2026-02-02 14:51:28,244 INFO OK: read value = false 2026-02-02 14:51:28,244 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false 2026-02-02 14:51:28,245 INFO OK: read value = false 2026-02-02 14:51:28,245 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false 2026-02-02 14:51:28,245 INFO OK: read value = false 2026-02-02 14:51:28,245 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false 2026-02-02 14:51:28,245 INFO OK: read value = false 2026-02-02 14:51:28,245 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false 2026-02-02 14:51:28,245 INFO OK: read value = false 2026-02-02 14:51:28,245 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false 2026-02-02 14:51:28,245 INFO OK: read value = false 2026-02-02 14:51:28,245 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false 2026-02-02 14:51:28,246 INFO OK: read value = false 2026-02-02 14:51:28,246 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false 2026-02-02 14:51:28,246 INFO OK: read value = false 2026-02-02 14:51:28,246 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false 2026-02-02 14:51:28,246 WARNING CHECK ERROR: read value = true 2026-02-02 14:51:28,246 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:51:28,246 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false 2026-02-02 14:51:28,246 WARNING CHECK ERROR: read value = true 2026-02-02 14:51:28,246 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:51:28,247 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false 2026-02-02 14:51:28,247 WARNING CHECK ERROR: read value = true 2026-02-02 14:51:28,247 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:51:28,247 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false 2026-02-02 14:51:28,247 INFO OK: read value = false 2026-02-02 14:51:28,247 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false 2026-02-02 14:51:28,247 INFO OK: read value = false 2026-02-02 14:51:28,247 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false 2026-02-02 14:51:28,247 INFO OK: read value = false 2026-02-02 14:51:28,248 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false 2026-02-02 14:51:28,248 INFO OK: read value = false 2026-02-02 14:51:28,248 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false 2026-02-02 14:51:28,248 INFO OK: read value = false 2026-02-02 14:51:28,248 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false 2026-02-02 14:51:28,248 INFO OK: read value = false 2026-02-02 14:51:28,248 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false 2026-02-02 14:51:28,248 INFO OK: read value = false 2026-02-02 14:51:28,248 WARNING B8_Test_SignalProcessor: 3/14 failures 2026-02-02 14:51:28,249 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false 2026-02-02 14:51:28,249 INFO OK: read value = false 2026-02-02 14:51:28,249 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false 2026-02-02 14:51:28,249 INFO OK: read value = false 2026-02-02 14:51:28,249 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false 2026-02-02 14:51:28,249 INFO OK: read value = false 2026-02-02 14:51:28,249 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false 2026-02-02 14:51:28,249 INFO OK: read value = false 2026-02-02 14:51:28,249 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false 2026-02-02 14:51:28,250 INFO OK: read value = false 2026-02-02 14:51:28,250 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false 2026-02-02 14:51:28,250 INFO OK: read value = false 2026-02-02 14:51:28,250 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false 2026-02-02 14:51:28,250 INFO OK: read value = false 2026-02-02 14:51:28,250 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false 2026-02-02 14:51:28,250 INFO OK: read value = false 2026-02-02 14:51:28,250 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false 2026-02-02 14:51:28,251 INFO OK: read value = false 2026-02-02 14:51:28,251 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false 2026-02-02 14:51:28,251 INFO OK: read value = false 2026-02-02 14:51:28,251 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false 2026-02-02 14:51:28,251 INFO OK: read value = false 2026-02-02 14:51:28,251 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false 2026-02-02 14:51:28,251 INFO OK: read value = false 2026-02-02 14:51:28,252 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false 2026-02-02 14:51:28,252 INFO OK: read value = false 2026-02-02 14:51:28,252 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false 2026-02-02 14:51:28,252 INFO OK: read value = false 2026-02-02 14:51:28,252 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false 2026-02-02 14:51:28,252 INFO OK: read value = false 2026-02-02 14:51:28,253 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false 2026-02-02 14:51:28,253 INFO OK: read value = false 2026-02-02 14:51:28,253 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false 2026-02-02 14:51:28,253 INFO OK: read value = false 2026-02-02 14:51:28,253 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false 2026-02-02 14:51:28,253 INFO OK: read value = false 2026-02-02 14:51:28,253 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false 2026-02-02 14:51:28,254 INFO OK: read value = false 2026-02-02 14:51:28,254 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false 2026-02-02 14:51:28,254 INFO OK: read value = false 2026-02-02 14:51:28,254 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false 2026-02-02 14:51:28,254 INFO OK: read value = false 2026-02-02 14:51:28,254 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false 2026-02-02 14:51:28,254 INFO OK: read value = false 2026-02-02 14:51:28,255 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false 2026-02-02 14:51:28,255 INFO OK: read value = false 2026-02-02 14:51:28,255 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false 2026-02-02 14:51:28,255 INFO OK: read value = false 2026-02-02 14:51:28,255 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false 2026-02-02 14:51:28,255 INFO OK: read value = false 2026-02-02 14:51:28,255 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false 2026-02-02 14:51:28,255 INFO OK: read value = false 2026-02-02 14:51:28,255 INFO [Run 1] B8 Diagnostics: 173 checked, 169 pass, 4 fail 2026-02-02 14:51:28,256 WARNING B8_Degradation: 1 failures - fail 2026-02-02 14:51:28,256 WARNING B8_Test_SignalProcessor: 3 failures - up, if, internal 2026-02-02 14:51:28,256 INFO 0.0s remaining ... 2026-02-02 14:51:28,256 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles 2026-02-02 14:51:28,256 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 2 Total Step 192: Success 185 (96.35%), Failed 7 (3.65%), 2026-02-02 14:51:28,256 INFO Repetition 2 of 2 2026-02-02 14:51:28,256 DEBUG [MOCK] Serial statistics reset 2026-02-02 14:51:28,256 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 14:51:29,257 INFO Set MAIN_POWER to False 2026-02-02 14:51:29,257 INFO [MOCK] Power OFF 2026-02-02 14:51:29,257 INFO [MOCK] 1553 Interface stopped 2026-02-02 14:51:34,258 INFO Check that MAIN_POWER is equal to 0 2026-02-02 14:51:34,258 INFO OK: read value = False 2026-02-02 14:51:38,259 INFO The test operator is required to switch on the target. 2026-02-02 14:51:38,260 INFO Set MAIN_POWER to True 2026-02-02 14:51:38,260 INFO [MOCK] Power ON 2026-02-02 14:51:38,260 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 14:51:38,261 INFO run_count = 2 2026-02-02 14:51:38,261 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 14:51:38,261 INFO current_scenario = 'mixed' 2026-02-02 14:51:38,261 INFO _scenario_list = ['sp_tests_fail', 'normal'] 2026-02-02 14:51:38,262 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 14:51:38,262 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='normal' 2026-02-02 14:51:38,262 INFO [DEBUG] About to call _log_scenario_info('normal', 2, 2) 2026-02-02 14:51:38,262 INFO 2026-02-02 14:51:38,262 INFO #################################################################################################### 2026-02-02 14:51:38,262 INFO #################################################################################################### 2026-02-02 14:51:38,262 INFO ### RUN 2/2: NORMAL OPERATION 2026-02-02 14:51:38,262 INFO #################################################################################################### 2026-02-02 14:51:38,263 INFO 2026-02-02 14:51:38,263 INFO SCENARIO: normal 2026-02-02 14:51:38,263 INFO DESCRIPTION: All systems operational - no failures 2026-02-02 14:51:38,263 INFO 2026-02-02 14:51:38,263 INFO EXPECTED FAILURES: 2026-02-02 14:51:38,263 INFO (none) 2026-02-02 14:51:38,263 INFO 2026-02-02 14:51:38,263 INFO EXPECTED PASSES: 2026-02-02 14:51:38,263 INFO ✓ All B6 status fields (except pedestal) 2026-02-02 14:51:38,263 INFO ✓ All B8 diagnostic fields 2026-02-02 14:51:38,263 INFO ✓ Target generation 2026-02-02 14:51:38,263 INFO 2026-02-02 14:51:38,263 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present) 2026-02-02 14:51:38,263 INFO 2026-02-02 14:51:38,263 INFO #################################################################################################### 2026-02-02 14:51:38,264 INFO #################################################################################################### 2026-02-02 14:51:38,264 INFO 2026-02-02 14:51:38,264 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 14:51:38,264 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected) 2026-02-02 14:51:38,264 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2) 2026-02-02 14:51:43,265 INFO Check that MAIN_POWER is equal to 1 2026-02-02 14:51:43,265 INFO OK: read value = True 2026-02-02 14:51:43,366 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 14:51:43,567 INFO [MOCK] BIT report available after 5.3s 2026-02-02 14:51:43,590 INFO BIT report available after 0.2s 2026-02-02 14:51:43,591 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false 2026-02-02 14:51:43,591 INFO OK: read value = false 2026-02-02 14:51:43,591 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false 2026-02-02 14:51:43,591 WARNING CHECK ERROR: read value = true 2026-02-02 14:51:43,591 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:51:43,591 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status 2026-02-02 14:51:43,592 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false 2026-02-02 14:51:43,592 INFO OK: read value = false 2026-02-02 14:51:43,592 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false 2026-02-02 14:51:43,592 INFO OK: read value = false 2026-02-02 14:51:43,592 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false 2026-02-02 14:51:43,592 INFO OK: read value = false 2026-02-02 14:51:43,592 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false 2026-02-02 14:51:43,592 INFO OK: read value = false 2026-02-02 14:51:43,593 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false 2026-02-02 14:51:43,593 INFO OK: read value = false 2026-02-02 14:51:43,593 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false 2026-02-02 14:51:43,593 INFO OK: read value = false 2026-02-02 14:51:43,593 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false 2026-02-02 14:51:43,593 INFO OK: read value = false 2026-02-02 14:51:43,593 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false 2026-02-02 14:51:43,593 INFO OK: read value = false 2026-02-02 14:51:43,593 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false 2026-02-02 14:51:43,594 INFO OK: read value = false 2026-02-02 14:51:43,594 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false 2026-02-02 14:51:43,594 WARNING CHECK ERROR: read value = RDR_OK 2026-02-02 14:51:43,594 ERROR INTERFACE ERROR: Expected false, got RDR_OK 2026-02-02 14:51:43,594 WARNING Radar fail status: Known failure (caused only by pedestal) 2026-02-02 14:51:43,594 INFO [Run 2] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known 2026-02-02 14:51:43,594 INFO Known failures (HW setup): 2 2026-02-02 14:51:43,594 INFO Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields... 2026-02-02 14:51:43,594 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures 2026-02-02 14:51:43,595 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false 2026-02-02 14:51:43,595 INFO OK: read value = false 2026-02-02 14:51:43,595 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false 2026-02-02 14:51:43,595 INFO OK: read value = false 2026-02-02 14:51:43,595 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false 2026-02-02 14:51:43,595 INFO OK: read value = false 2026-02-02 14:51:43,595 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false 2026-02-02 14:51:43,595 INFO OK: read value = false 2026-02-02 14:51:43,595 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false 2026-02-02 14:51:43,595 INFO OK: read value = false 2026-02-02 14:51:43,596 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false 2026-02-02 14:51:43,596 INFO OK: read value = false 2026-02-02 14:51:43,596 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false 2026-02-02 14:51:43,596 INFO OK: read value = false 2026-02-02 14:51:43,596 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false 2026-02-02 14:51:43,596 INFO OK: read value = false 2026-02-02 14:51:43,597 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false 2026-02-02 14:51:43,597 INFO OK: read value = false 2026-02-02 14:51:43,599 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false 2026-02-02 14:51:43,599 WARNING CHECK ERROR: read value = 0 2026-02-02 14:51:43,600 ERROR INTERFACE ERROR: Expected false, got 0 2026-02-02 14:51:43,600 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false 2026-02-02 14:51:43,600 INFO OK: read value = false 2026-02-02 14:51:43,600 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false 2026-02-02 14:51:43,600 INFO OK: read value = false 2026-02-02 14:51:43,600 WARNING B8_Degradation: 1/12 failures 2026-02-02 14:51:43,600 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false 2026-02-02 14:51:43,600 INFO OK: read value = false 2026-02-02 14:51:43,601 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false 2026-02-02 14:51:43,601 INFO OK: read value = false 2026-02-02 14:51:43,601 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false 2026-02-02 14:51:43,601 INFO OK: read value = false 2026-02-02 14:51:43,601 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false 2026-02-02 14:51:43,601 INFO OK: read value = false 2026-02-02 14:51:43,601 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false 2026-02-02 14:51:43,601 INFO OK: read value = false 2026-02-02 14:51:43,601 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false 2026-02-02 14:51:43,601 INFO OK: read value = false 2026-02-02 14:51:43,602 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false 2026-02-02 14:51:43,602 INFO OK: read value = false 2026-02-02 14:51:43,602 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false 2026-02-02 14:51:43,602 INFO OK: read value = false 2026-02-02 14:51:43,602 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false 2026-02-02 14:51:43,602 INFO OK: read value = false 2026-02-02 14:51:43,602 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false 2026-02-02 14:51:43,602 INFO OK: read value = false 2026-02-02 14:51:43,602 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false 2026-02-02 14:51:43,603 INFO OK: read value = false 2026-02-02 14:51:43,603 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false 2026-02-02 14:51:43,603 INFO OK: read value = false 2026-02-02 14:51:43,603 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false 2026-02-02 14:51:43,603 INFO OK: read value = false 2026-02-02 14:51:43,603 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false 2026-02-02 14:51:43,603 INFO OK: read value = false 2026-02-02 14:51:43,603 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false 2026-02-02 14:51:43,603 INFO OK: read value = false 2026-02-02 14:51:43,603 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false 2026-02-02 14:51:43,603 INFO OK: read value = false 2026-02-02 14:51:43,603 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false 2026-02-02 14:51:43,604 INFO OK: read value = false 2026-02-02 14:51:43,604 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false 2026-02-02 14:51:43,604 INFO OK: read value = false 2026-02-02 14:51:43,604 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false 2026-02-02 14:51:43,604 INFO OK: read value = false 2026-02-02 14:51:43,604 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false 2026-02-02 14:51:43,604 INFO OK: read value = false 2026-02-02 14:51:43,604 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false 2026-02-02 14:51:43,604 INFO OK: read value = false 2026-02-02 14:51:43,604 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false 2026-02-02 14:51:43,605 INFO OK: read value = false 2026-02-02 14:51:43,605 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false 2026-02-02 14:51:43,605 INFO OK: read value = false 2026-02-02 14:51:43,605 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false 2026-02-02 14:51:43,605 INFO OK: read value = false 2026-02-02 14:51:43,605 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false 2026-02-02 14:51:43,605 INFO OK: read value = false 2026-02-02 14:51:43,605 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false 2026-02-02 14:51:43,605 INFO OK: read value = false 2026-02-02 14:51:43,606 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false 2026-02-02 14:51:43,607 INFO OK: read value = false 2026-02-02 14:51:43,607 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false 2026-02-02 14:51:43,607 INFO OK: read value = false 2026-02-02 14:51:43,607 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false 2026-02-02 14:51:43,607 INFO OK: read value = false 2026-02-02 14:51:43,607 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false 2026-02-02 14:51:43,608 INFO OK: read value = false 2026-02-02 14:51:43,608 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false 2026-02-02 14:51:43,608 INFO OK: read value = false 2026-02-02 14:51:43,608 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false 2026-02-02 14:51:43,608 INFO OK: read value = false 2026-02-02 14:51:43,608 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false 2026-02-02 14:51:43,608 INFO OK: read value = false 2026-02-02 14:51:43,608 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false 2026-02-02 14:51:43,608 INFO OK: read value = false 2026-02-02 14:51:43,609 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false 2026-02-02 14:51:43,609 INFO OK: read value = false 2026-02-02 14:51:43,609 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false 2026-02-02 14:51:43,609 INFO OK: read value = false 2026-02-02 14:51:43,609 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false 2026-02-02 14:51:43,609 INFO OK: read value = false 2026-02-02 14:51:43,609 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false 2026-02-02 14:51:43,609 INFO OK: read value = false 2026-02-02 14:51:43,609 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false 2026-02-02 14:51:43,610 INFO OK: read value = false 2026-02-02 14:51:43,610 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false 2026-02-02 14:51:43,610 INFO OK: read value = false 2026-02-02 14:51:43,610 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false 2026-02-02 14:51:43,610 INFO OK: read value = false 2026-02-02 14:51:43,610 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false 2026-02-02 14:51:43,610 INFO OK: read value = false 2026-02-02 14:51:43,610 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false 2026-02-02 14:51:43,611 INFO OK: read value = false 2026-02-02 14:51:43,611 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false 2026-02-02 14:51:43,611 INFO OK: read value = false 2026-02-02 14:51:43,611 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false 2026-02-02 14:51:43,611 INFO OK: read value = false 2026-02-02 14:51:43,611 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false 2026-02-02 14:51:43,611 INFO OK: read value = false 2026-02-02 14:51:43,612 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false 2026-02-02 14:51:43,612 INFO OK: read value = false 2026-02-02 14:51:43,612 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false 2026-02-02 14:51:43,612 INFO OK: read value = false 2026-02-02 14:51:43,612 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false 2026-02-02 14:51:43,612 INFO OK: read value = false 2026-02-02 14:51:43,612 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false 2026-02-02 14:51:43,612 INFO OK: read value = false 2026-02-02 14:51:43,613 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false 2026-02-02 14:51:43,613 INFO OK: read value = false 2026-02-02 14:51:43,614 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false 2026-02-02 14:51:43,614 INFO OK: read value = false 2026-02-02 14:51:43,614 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false 2026-02-02 14:51:43,618 INFO OK: read value = false 2026-02-02 14:51:43,620 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false 2026-02-02 14:51:43,622 INFO OK: read value = false 2026-02-02 14:51:43,623 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false 2026-02-02 14:51:43,623 INFO OK: read value = false 2026-02-02 14:51:43,623 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false 2026-02-02 14:51:43,623 INFO OK: read value = false 2026-02-02 14:51:43,625 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false 2026-02-02 14:51:43,626 INFO OK: read value = false 2026-02-02 14:51:43,627 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false 2026-02-02 14:51:43,627 INFO OK: read value = false 2026-02-02 14:51:43,627 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false 2026-02-02 14:51:43,627 INFO OK: read value = false 2026-02-02 14:51:43,628 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false 2026-02-02 14:51:43,630 INFO OK: read value = false 2026-02-02 14:51:43,631 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false 2026-02-02 14:51:43,631 INFO OK: read value = false 2026-02-02 14:51:43,631 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false 2026-02-02 14:51:43,632 INFO OK: read value = false 2026-02-02 14:51:43,632 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false 2026-02-02 14:51:43,632 INFO OK: read value = false 2026-02-02 14:51:43,633 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false 2026-02-02 14:51:43,633 INFO OK: read value = false 2026-02-02 14:51:43,633 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false 2026-02-02 14:51:43,633 INFO OK: read value = false 2026-02-02 14:51:43,634 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false 2026-02-02 14:51:43,634 INFO OK: read value = false 2026-02-02 14:51:43,634 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false 2026-02-02 14:51:43,635 INFO OK: read value = false 2026-02-02 14:51:43,635 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false 2026-02-02 14:51:43,635 INFO OK: read value = false 2026-02-02 14:51:43,635 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false 2026-02-02 14:51:43,635 INFO OK: read value = false 2026-02-02 14:51:43,636 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false 2026-02-02 14:51:43,636 INFO OK: read value = false 2026-02-02 14:51:43,636 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false 2026-02-02 14:51:43,636 INFO OK: read value = false 2026-02-02 14:51:43,636 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false 2026-02-02 14:51:43,636 INFO OK: read value = false 2026-02-02 14:51:43,637 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false 2026-02-02 14:51:43,637 INFO OK: read value = false 2026-02-02 14:51:43,637 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false 2026-02-02 14:51:43,637 INFO OK: read value = false 2026-02-02 14:51:43,637 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false 2026-02-02 14:51:43,637 INFO OK: read value = false 2026-02-02 14:51:43,638 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false 2026-02-02 14:51:43,638 INFO OK: read value = false 2026-02-02 14:51:43,638 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false 2026-02-02 14:51:43,638 INFO OK: read value = false 2026-02-02 14:51:43,638 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false 2026-02-02 14:51:43,638 INFO OK: read value = false 2026-02-02 14:51:43,638 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false 2026-02-02 14:51:43,638 INFO OK: read value = false 2026-02-02 14:51:43,639 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false 2026-02-02 14:51:43,639 INFO OK: read value = false 2026-02-02 14:51:43,639 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false 2026-02-02 14:51:43,639 INFO OK: read value = false 2026-02-02 14:51:43,639 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false 2026-02-02 14:51:43,639 INFO OK: read value = false 2026-02-02 14:51:43,639 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false 2026-02-02 14:51:43,639 INFO OK: read value = false 2026-02-02 14:51:43,640 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false 2026-02-02 14:51:43,640 INFO OK: read value = false 2026-02-02 14:51:43,640 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false 2026-02-02 14:51:43,640 INFO OK: read value = false 2026-02-02 14:51:43,640 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false 2026-02-02 14:51:43,640 INFO OK: read value = false 2026-02-02 14:51:43,640 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false 2026-02-02 14:51:43,641 INFO OK: read value = false 2026-02-02 14:51:43,641 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false 2026-02-02 14:51:43,641 INFO OK: read value = false 2026-02-02 14:51:43,641 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false 2026-02-02 14:51:43,641 INFO OK: read value = false 2026-02-02 14:51:43,641 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false 2026-02-02 14:51:43,641 INFO OK: read value = false 2026-02-02 14:51:43,641 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false 2026-02-02 14:51:43,642 INFO OK: read value = false 2026-02-02 14:51:43,642 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false 2026-02-02 14:51:43,642 INFO OK: read value = false 2026-02-02 14:51:43,642 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false 2026-02-02 14:51:43,642 INFO OK: read value = false 2026-02-02 14:51:43,642 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false 2026-02-02 14:51:43,642 INFO OK: read value = false 2026-02-02 14:51:43,643 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false 2026-02-02 14:51:43,643 INFO OK: read value = false 2026-02-02 14:51:43,643 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false 2026-02-02 14:51:43,643 INFO OK: read value = false 2026-02-02 14:51:43,643 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false 2026-02-02 14:51:43,643 INFO OK: read value = false 2026-02-02 14:51:43,643 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false 2026-02-02 14:51:43,644 INFO OK: read value = false 2026-02-02 14:51:43,644 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false 2026-02-02 14:51:43,644 INFO OK: read value = false 2026-02-02 14:51:43,644 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false 2026-02-02 14:51:43,644 INFO OK: read value = false 2026-02-02 14:51:43,644 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false 2026-02-02 14:51:43,644 INFO OK: read value = false 2026-02-02 14:51:43,644 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false 2026-02-02 14:51:43,644 INFO OK: read value = false 2026-02-02 14:51:43,645 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false 2026-02-02 14:51:43,645 INFO OK: read value = false 2026-02-02 14:51:43,645 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false 2026-02-02 14:51:43,645 INFO OK: read value = false 2026-02-02 14:51:43,645 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false 2026-02-02 14:51:43,645 INFO OK: read value = false 2026-02-02 14:51:43,645 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false 2026-02-02 14:51:43,645 INFO OK: read value = false 2026-02-02 14:51:43,645 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false 2026-02-02 14:51:43,646 INFO OK: read value = false 2026-02-02 14:51:43,646 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false 2026-02-02 14:51:43,646 INFO OK: read value = false 2026-02-02 14:51:43,646 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false 2026-02-02 14:51:43,646 INFO OK: read value = false 2026-02-02 14:51:43,646 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false 2026-02-02 14:51:43,646 INFO OK: read value = false 2026-02-02 14:51:43,646 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false 2026-02-02 14:51:43,647 INFO OK: read value = false 2026-02-02 14:51:43,647 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false 2026-02-02 14:51:43,647 INFO OK: read value = false 2026-02-02 14:51:43,647 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false 2026-02-02 14:51:43,647 INFO OK: read value = false 2026-02-02 14:51:43,647 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false 2026-02-02 14:51:43,647 INFO OK: read value = false 2026-02-02 14:51:43,648 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false 2026-02-02 14:51:43,648 INFO OK: read value = false 2026-02-02 14:51:43,648 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false 2026-02-02 14:51:43,648 INFO OK: read value = false 2026-02-02 14:51:43,648 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false 2026-02-02 14:51:43,648 INFO OK: read value = false 2026-02-02 14:51:43,648 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false 2026-02-02 14:51:43,648 INFO OK: read value = false 2026-02-02 14:51:43,648 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false 2026-02-02 14:51:43,649 INFO OK: read value = false 2026-02-02 14:51:43,649 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false 2026-02-02 14:51:43,649 INFO OK: read value = false 2026-02-02 14:51:43,649 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false 2026-02-02 14:51:43,649 INFO OK: read value = false 2026-02-02 14:51:43,649 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false 2026-02-02 14:51:43,649 INFO OK: read value = false 2026-02-02 14:51:43,649 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false 2026-02-02 14:51:43,650 INFO OK: read value = false 2026-02-02 14:51:43,650 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false 2026-02-02 14:51:43,650 INFO OK: read value = false 2026-02-02 14:51:43,650 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false 2026-02-02 14:51:43,650 INFO OK: read value = false 2026-02-02 14:51:43,650 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false 2026-02-02 14:51:43,650 INFO OK: read value = false 2026-02-02 14:51:43,650 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false 2026-02-02 14:51:43,651 INFO OK: read value = false 2026-02-02 14:51:43,651 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false 2026-02-02 14:51:43,651 INFO OK: read value = false 2026-02-02 14:51:43,651 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false 2026-02-02 14:51:43,651 INFO OK: read value = false 2026-02-02 14:51:43,651 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false 2026-02-02 14:51:43,651 INFO OK: read value = false 2026-02-02 14:51:43,651 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false 2026-02-02 14:51:43,652 INFO OK: read value = false 2026-02-02 14:51:43,652 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false 2026-02-02 14:51:43,652 INFO OK: read value = false 2026-02-02 14:51:43,652 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false 2026-02-02 14:51:43,652 INFO OK: read value = false 2026-02-02 14:51:43,652 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false 2026-02-02 14:51:43,652 INFO OK: read value = false 2026-02-02 14:51:43,652 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false 2026-02-02 14:51:43,653 INFO OK: read value = false 2026-02-02 14:51:43,653 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false 2026-02-02 14:51:43,653 INFO OK: read value = false 2026-02-02 14:51:43,653 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false 2026-02-02 14:51:43,653 INFO OK: read value = false 2026-02-02 14:51:43,653 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false 2026-02-02 14:51:43,653 INFO OK: read value = false 2026-02-02 14:51:43,653 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false 2026-02-02 14:51:43,653 INFO OK: read value = false 2026-02-02 14:51:43,657 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false 2026-02-02 14:51:43,657 INFO OK: read value = false 2026-02-02 14:51:43,657 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false 2026-02-02 14:51:43,657 INFO OK: read value = false 2026-02-02 14:51:43,657 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false 2026-02-02 14:51:43,658 INFO OK: read value = false 2026-02-02 14:51:43,658 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false 2026-02-02 14:51:43,659 INFO OK: read value = false 2026-02-02 14:51:43,659 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false 2026-02-02 14:51:43,659 INFO OK: read value = false 2026-02-02 14:51:43,659 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false 2026-02-02 14:51:43,660 INFO OK: read value = false 2026-02-02 14:51:43,660 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false 2026-02-02 14:51:43,660 INFO OK: read value = false 2026-02-02 14:51:43,660 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false 2026-02-02 14:51:43,660 INFO OK: read value = false 2026-02-02 14:51:43,660 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false 2026-02-02 14:51:43,661 INFO OK: read value = false 2026-02-02 14:51:43,661 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false 2026-02-02 14:51:43,661 INFO OK: read value = false 2026-02-02 14:51:43,661 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false 2026-02-02 14:51:43,661 INFO OK: read value = false 2026-02-02 14:51:43,661 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false 2026-02-02 14:51:43,661 INFO OK: read value = false 2026-02-02 14:51:43,661 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false 2026-02-02 14:51:43,662 INFO OK: read value = false 2026-02-02 14:51:43,662 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false 2026-02-02 14:51:43,662 INFO OK: read value = false 2026-02-02 14:51:43,662 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false 2026-02-02 14:51:43,662 INFO OK: read value = false 2026-02-02 14:51:43,662 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false 2026-02-02 14:51:43,663 INFO OK: read value = false 2026-02-02 14:51:43,663 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false 2026-02-02 14:51:43,663 INFO OK: read value = false 2026-02-02 14:51:43,663 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false 2026-02-02 14:51:43,663 INFO OK: read value = false 2026-02-02 14:51:43,663 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false 2026-02-02 14:51:43,664 INFO OK: read value = false 2026-02-02 14:51:43,664 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false 2026-02-02 14:51:43,664 INFO OK: read value = false 2026-02-02 14:51:43,664 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false 2026-02-02 14:51:43,664 INFO OK: read value = false 2026-02-02 14:51:43,664 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false 2026-02-02 14:51:43,665 INFO OK: read value = false 2026-02-02 14:51:43,665 INFO [Run 2] B8 Diagnostics: 173 checked, 172 pass, 1 fail 2026-02-02 14:51:43,665 WARNING B8_Degradation: 1 failures - fail 2026-02-02 14:51:43,665 INFO 0.0s remaining ... 2026-02-02 14:51:43,665 INFO [Run 2] Serial: 0 total, 0 errors, 0 fatal, 0 recycles 2026-02-02 14:51:43,666 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 2 Total Step 190: Success 187 (98.42%), Failed 3 (1.58%), 2026-02-02 14:51:43,666 INFO tgt_gen() 2026-02-02 14:51:43,676 DEBUG [MOCK] Field rng: 1180 2026-02-02 14:51:43,676 INFO TgtMsg: 1 1 2026-02-02 14:51:43,676 INFO Tgt: 1 @ 1180 2026-02-02 14:51:43,677 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 14:51:43,677 INFO OK: read value = 1 2026-02-02 14:51:43,677 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 14:51:43,677 DEBUG [MOCK] Field rng: 1180 2026-02-02 14:51:43,677 INFO OK: read value = 1180 2026-02-02 14:51:43,677 INFO Repetitions terminated. 2026-02-02 14:51:43,678 INFO [Report] Custom statistics data registered for PDF generation 2026-02-02 14:51:43,678 INFO ========================================================================================== 2026-02-02 14:51:43,678 INFO FINAL TEST STATISTICS SUMMARY 2026-02-02 14:51:43,678 INFO ========================================================================================== 2026-02-02 14:51:43,678 INFO Total Runs: 2 2026-02-02 14:51:43,678 INFO Successful: 1 (50.0%) 2026-02-02 14:51:43,678 INFO Failed: 1 (50.0%) 2026-02-02 14:51:43,678 INFO B6 Checks: 24 (Pass: 19, Fail: 2, Known: 3) 2026-02-02 14:51:43,678 INFO B8 Checks: 346 (Pass: 341, Fail: 5) 2026-02-02 14:51:43,679 INFO Serial: 0 messages (0 errors, 0 fatal, 0 recycles) 2026-02-02 14:51:43,679 INFO PBIT Timing: avg=0.22s, min=0.22s, max=0.22s, σ=0.00s 2026-02-02 14:51:43,679 INFO ========================================================================================== 2026-02-02 14:51:43,679 INFO Detailed statistics will be available in the PDF report 2026-02-02 14:51:43,679 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_145143_statistics.csv 2026-02-02 14:51:43,682 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_145143_statistics.csv 2026-02-02 14:51:43,682 INFO Statistics exported successfully to JSON: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_145143_statistics.json 2026-02-02 14:51:43,683 INFO Set MAIN_POWER to False 2026-02-02 14:51:43,683 INFO [MOCK] Power OFF 2026-02-02 14:51:43,683 INFO [MOCK] 1553 Interface stopped 2026-02-02 14:51:48,684 INFO Check that MAIN_POWER is equal to 0 2026-02-02 14:51:48,685 INFO OK: read value = False 2026-02-02 14:51:48,685 INFO [MOCK] Serial terminal disconnected 2026-02-02 14:51:48,685 INFO Stop Time: 2026-02-02 14:51:12.751451 2026-02-02 14:51:48,685 INFO Test execution time: 0:00:35.934101