2026-02-02 15:23:17,298 INFO Start Time: 2026-02-02 15:23:17.298136 2026-02-02 15:23:17,298 INFO [MOCK] Serial terminal initialized 2026-02-02 15:23:17,298 INFO [MOCK] Serial terminal connected 2026-02-02 15:23:17,298 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!****** 2026-02-02 15:23:17,401 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!****** 2026-02-02 15:23:17,401 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ... 2026-02-02 15:23:17,410 INFO [MOCK] Simulating target acquisition: will appear after 10 scan cycles 2026-02-02 15:23:17,411 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,463 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,517 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,573 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,636 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,688 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,752 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,811 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,870 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,935 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:17,999 INFO [MOCK] Target simulated at distance 1180 2026-02-02 15:23:17,999 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts 2026-02-02 15:23:17,999 INFO tgt_gen_alone(): 0 2026-02-02 15:23:18,000 INFO tgt_gen() - timeout: 5.0s 2026-02-02 15:23:18,014 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 15:23:18,014 DEBUG [MOCK] Field rng: 1180 2026-02-02 15:23:18,014 INFO TgtMsg: 0 0 2026-02-02 15:23:18,014 INFO Tgt: 1 @ 1180 2026-02-02 15:23:18,015 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 15:23:18,015 INFO OK: read value = 1 2026-02-02 15:23:18,015 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 15:23:18,015 INFO OK: read value = 1180 2026-02-02 15:23:18,015 INFO [MOCK] Log stopped 2026-02-02 15:23:18,015 INFO Repetition 1 of 3 2026-02-02 15:23:18,016 DEBUG [MOCK] Serial statistics reset 2026-02-02 15:23:18,016 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 15:23:19,025 INFO Set MAIN_POWER to False 2026-02-02 15:23:19,025 INFO [MOCK] Power OFF 2026-02-02 15:23:19,025 INFO [MOCK] 1553 Interface stopped 2026-02-02 15:23:24,026 INFO Check that MAIN_POWER is equal to 0 2026-02-02 15:23:24,027 INFO OK: read value = False 2026-02-02 15:23:28,041 INFO The test operator is required to switch on the target. 2026-02-02 15:23:28,041 INFO Set MAIN_POWER to True 2026-02-02 15:23:28,041 INFO [MOCK] Power ON 2026-02-02 15:23:28,042 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 15:23:28,042 INFO run_count = 1 2026-02-02 15:23:28,042 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 15:23:28,042 INFO current_scenario = 'mixed' 2026-02-02 15:23:28,042 INFO _scenario_list = ['tx_tests_fail', 'sp_tests_fail', 'normal'] 2026-02-02 15:23:28,042 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 15:23:28,042 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='tx_tests_fail' 2026-02-02 15:23:28,042 INFO [DEBUG] About to call _log_scenario_info('tx_tests_fail', 1, 3) 2026-02-02 15:23:28,043 INFO 2026-02-02 15:23:28,043 INFO #################################################################################################### 2026-02-02 15:23:28,043 INFO #################################################################################################### 2026-02-02 15:23:28,043 INFO ### RUN 1/3: TRANSMITTER TEST FAILURES 2026-02-02 15:23:28,043 INFO #################################################################################################### 2026-02-02 15:23:28,044 INFO 2026-02-02 15:23:28,044 INFO SCENARIO: tx_tests_fail 2026-02-02 15:23:28,044 INFO DESCRIPTION: Individual TX tests fail (TX10, TX11, TX12) 2026-02-02 15:23:28,044 INFO 2026-02-02 15:23:28,044 INFO EXPECTED FAILURES: 2026-02-02 15:23:28,044 INFO ✗ B8: test_tx10_hv_ps_over_temperature_warning = FAIL 2026-02-02 15:23:28,044 INFO ✗ B8: test_tx11_twt_helix_over_current = FAIL 2026-02-02 15:23:28,045 INFO ✗ B8: test_tx12_cathode_to_helix_arc = FAIL 2026-02-02 15:23:28,045 INFO 2026-02-02 15:23:28,045 INFO EXPECTED PASSES: 2026-02-02 15:23:28,045 INFO ✓ B6 status fields (except transmitter) 2026-02-02 15:23:28,045 INFO ✓ Other B8 tests 2026-02-02 15:23:28,045 INFO 2026-02-02 15:23:28,045 INFO NOTES: Demonstrates granular test failure analysis - specific TX high-voltage issues 2026-02-02 15:23:28,045 INFO 2026-02-02 15:23:28,045 INFO #################################################################################################### 2026-02-02 15:23:28,046 INFO #################################################################################################### 2026-02-02 15:23:28,046 INFO 2026-02-02 15:23:28,046 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 15:23:28,046 INFO [MOCK APPLY] ✗ Setting trasmitter_status = FAIL 2026-02-02 15:23:28,046 INFO [MOCK APPLY] ✗ B8 failures: TX10 (hv_ps_over_temp), TX11 (twt_helix_overcurrent), TX12 (cathode_arc) 2026-02-02 15:23:28,046 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1) 2026-02-02 15:23:33,058 INFO Check that MAIN_POWER is equal to 1 2026-02-02 15:23:33,058 INFO OK: read value = True 2026-02-02 15:23:33,170 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 15:23:33,374 INFO [MOCK] BIT report available after 5.3s 2026-02-02 15:23:33,405 INFO BIT report available after 0.2s 2026-02-02 15:23:33,406 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false 2026-02-02 15:23:33,406 INFO OK: read value = false 2026-02-02 15:23:33,406 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false 2026-02-02 15:23:33,406 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:33,406 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:33,406 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status 2026-02-02 15:23:33,406 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false 2026-02-02 15:23:33,407 INFO OK: read value = false 2026-02-02 15:23:33,407 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false 2026-02-02 15:23:33,407 INFO OK: read value = false 2026-02-02 15:23:33,407 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false 2026-02-02 15:23:33,407 INFO OK: read value = false 2026-02-02 15:23:33,407 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false 2026-02-02 15:23:33,408 INFO OK: read value = false 2026-02-02 15:23:33,408 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false 2026-02-02 15:23:33,408 INFO OK: read value = false 2026-02-02 15:23:33,408 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false 2026-02-02 15:23:33,408 INFO OK: read value = false 2026-02-02 15:23:33,408 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false 2026-02-02 15:23:33,408 INFO OK: read value = false 2026-02-02 15:23:33,409 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false 2026-02-02 15:23:33,409 INFO OK: read value = false 2026-02-02 15:23:33,409 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false 2026-02-02 15:23:33,409 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:33,409 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:33,409 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false 2026-02-02 15:23:33,409 DEBUG [MOCK] Field status: RDR_FAIL 2026-02-02 15:23:33,409 WARNING CHECK ERROR: read value = RDR_FAIL 2026-02-02 15:23:33,409 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL 2026-02-02 15:23:33,409 WARNING Radar fail status: REAL failure (caused by: status, status) 2026-02-02 15:23:33,409 INFO [Run 1] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known 2026-02-02 15:23:33,409 INFO Known failures (HW setup): 1 2026-02-02 15:23:33,409 WARNING Real failures: status, status 2026-02-02 15:23:33,410 INFO Drill-down: Verifying all 173 B8 diagnostic fields... 2026-02-02 15:23:33,410 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false 2026-02-02 15:23:33,410 INFO OK: read value = false 2026-02-02 15:23:33,410 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false 2026-02-02 15:23:33,410 INFO OK: read value = false 2026-02-02 15:23:33,410 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false 2026-02-02 15:23:33,410 INFO OK: read value = false 2026-02-02 15:23:33,410 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false 2026-02-02 15:23:33,410 INFO OK: read value = false 2026-02-02 15:23:33,410 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false 2026-02-02 15:23:33,411 INFO OK: read value = false 2026-02-02 15:23:33,411 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false 2026-02-02 15:23:33,412 INFO OK: read value = false 2026-02-02 15:23:33,412 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false 2026-02-02 15:23:33,412 INFO OK: read value = false 2026-02-02 15:23:33,412 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false 2026-02-02 15:23:33,412 INFO OK: read value = false 2026-02-02 15:23:33,412 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false 2026-02-02 15:23:33,412 INFO OK: read value = false 2026-02-02 15:23:33,413 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false 2026-02-02 15:23:33,413 WARNING CHECK ERROR: read value = 0 2026-02-02 15:23:33,413 ERROR INTERFACE ERROR: Expected false, got 0 2026-02-02 15:23:33,413 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false 2026-02-02 15:23:33,413 INFO OK: read value = false 2026-02-02 15:23:33,413 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false 2026-02-02 15:23:33,413 INFO OK: read value = false 2026-02-02 15:23:33,413 WARNING B8_Degradation: 1/12 failures 2026-02-02 15:23:33,413 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false 2026-02-02 15:23:33,413 INFO OK: read value = false 2026-02-02 15:23:33,415 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false 2026-02-02 15:23:33,415 INFO OK: read value = false 2026-02-02 15:23:33,415 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false 2026-02-02 15:23:33,415 INFO OK: read value = false 2026-02-02 15:23:33,415 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false 2026-02-02 15:23:33,415 INFO OK: read value = false 2026-02-02 15:23:33,415 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false 2026-02-02 15:23:33,415 INFO OK: read value = false 2026-02-02 15:23:33,416 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false 2026-02-02 15:23:33,416 INFO OK: read value = false 2026-02-02 15:23:33,416 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false 2026-02-02 15:23:33,416 INFO OK: read value = false 2026-02-02 15:23:33,416 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false 2026-02-02 15:23:33,417 INFO OK: read value = false 2026-02-02 15:23:33,417 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false 2026-02-02 15:23:33,418 INFO OK: read value = false 2026-02-02 15:23:33,418 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false 2026-02-02 15:23:33,418 INFO OK: read value = false 2026-02-02 15:23:33,418 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false 2026-02-02 15:23:33,418 INFO OK: read value = false 2026-02-02 15:23:33,418 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false 2026-02-02 15:23:33,418 INFO OK: read value = false 2026-02-02 15:23:33,418 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false 2026-02-02 15:23:33,418 INFO OK: read value = false 2026-02-02 15:23:33,421 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false 2026-02-02 15:23:33,426 INFO OK: read value = false 2026-02-02 15:23:33,426 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false 2026-02-02 15:23:33,426 INFO OK: read value = false 2026-02-02 15:23:33,426 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false 2026-02-02 15:23:33,426 INFO OK: read value = false 2026-02-02 15:23:33,426 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false 2026-02-02 15:23:33,426 INFO OK: read value = false 2026-02-02 15:23:33,427 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false 2026-02-02 15:23:33,427 INFO OK: read value = false 2026-02-02 15:23:33,427 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false 2026-02-02 15:23:33,427 INFO OK: read value = false 2026-02-02 15:23:33,427 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false 2026-02-02 15:23:33,427 INFO OK: read value = false 2026-02-02 15:23:33,427 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false 2026-02-02 15:23:33,427 INFO OK: read value = false 2026-02-02 15:23:33,427 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false 2026-02-02 15:23:33,428 INFO OK: read value = false 2026-02-02 15:23:33,428 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false 2026-02-02 15:23:33,428 INFO OK: read value = false 2026-02-02 15:23:33,428 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false 2026-02-02 15:23:33,428 INFO OK: read value = false 2026-02-02 15:23:33,428 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false 2026-02-02 15:23:33,428 INFO OK: read value = false 2026-02-02 15:23:33,428 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false 2026-02-02 15:23:33,428 INFO OK: read value = false 2026-02-02 15:23:33,428 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false 2026-02-02 15:23:33,429 INFO OK: read value = false 2026-02-02 15:23:33,429 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false 2026-02-02 15:23:33,429 INFO OK: read value = false 2026-02-02 15:23:33,429 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false 2026-02-02 15:23:33,429 INFO OK: read value = false 2026-02-02 15:23:33,429 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false 2026-02-02 15:23:33,429 INFO OK: read value = false 2026-02-02 15:23:33,429 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false 2026-02-02 15:23:33,429 INFO OK: read value = false 2026-02-02 15:23:33,429 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false 2026-02-02 15:23:33,429 INFO OK: read value = false 2026-02-02 15:23:33,430 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false 2026-02-02 15:23:33,430 INFO OK: read value = false 2026-02-02 15:23:33,430 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false 2026-02-02 15:23:33,430 INFO OK: read value = false 2026-02-02 15:23:33,430 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false 2026-02-02 15:23:33,430 INFO OK: read value = false 2026-02-02 15:23:33,430 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false 2026-02-02 15:23:33,430 INFO OK: read value = false 2026-02-02 15:23:33,430 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false 2026-02-02 15:23:33,431 INFO OK: read value = false 2026-02-02 15:23:33,431 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false 2026-02-02 15:23:33,431 INFO OK: read value = false 2026-02-02 15:23:33,431 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false 2026-02-02 15:23:33,431 INFO OK: read value = false 2026-02-02 15:23:33,431 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false 2026-02-02 15:23:33,431 INFO OK: read value = false 2026-02-02 15:23:33,431 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false 2026-02-02 15:23:33,431 INFO OK: read value = false 2026-02-02 15:23:33,431 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false 2026-02-02 15:23:33,431 INFO OK: read value = false 2026-02-02 15:23:33,432 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false 2026-02-02 15:23:33,432 INFO OK: read value = false 2026-02-02 15:23:33,432 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false 2026-02-02 15:23:33,432 INFO OK: read value = false 2026-02-02 15:23:33,432 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false 2026-02-02 15:23:33,432 INFO OK: read value = false 2026-02-02 15:23:33,432 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false 2026-02-02 15:23:33,432 INFO OK: read value = false 2026-02-02 15:23:33,432 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false 2026-02-02 15:23:33,432 INFO OK: read value = false 2026-02-02 15:23:33,433 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false 2026-02-02 15:23:33,433 INFO OK: read value = false 2026-02-02 15:23:33,433 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false 2026-02-02 15:23:33,433 INFO OK: read value = false 2026-02-02 15:23:33,433 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false 2026-02-02 15:23:33,433 INFO OK: read value = false 2026-02-02 15:23:33,434 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false 2026-02-02 15:23:33,434 INFO OK: read value = false 2026-02-02 15:23:33,434 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false 2026-02-02 15:23:33,434 INFO OK: read value = false 2026-02-02 15:23:33,434 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false 2026-02-02 15:23:33,434 INFO OK: read value = false 2026-02-02 15:23:33,434 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false 2026-02-02 15:23:33,434 INFO OK: read value = false 2026-02-02 15:23:33,434 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false 2026-02-02 15:23:33,435 INFO OK: read value = false 2026-02-02 15:23:33,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false 2026-02-02 15:23:33,435 INFO OK: read value = false 2026-02-02 15:23:33,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false 2026-02-02 15:23:33,435 INFO OK: read value = false 2026-02-02 15:23:33,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false 2026-02-02 15:23:33,435 INFO OK: read value = false 2026-02-02 15:23:33,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false 2026-02-02 15:23:33,436 INFO OK: read value = false 2026-02-02 15:23:33,436 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false 2026-02-02 15:23:33,436 INFO OK: read value = false 2026-02-02 15:23:33,436 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false 2026-02-02 15:23:33,436 INFO OK: read value = false 2026-02-02 15:23:33,436 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false 2026-02-02 15:23:33,436 INFO OK: read value = false 2026-02-02 15:23:33,437 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false 2026-02-02 15:23:33,437 INFO OK: read value = false 2026-02-02 15:23:33,437 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false 2026-02-02 15:23:33,437 INFO OK: read value = false 2026-02-02 15:23:33,437 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false 2026-02-02 15:23:33,437 INFO OK: read value = false 2026-02-02 15:23:33,437 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false 2026-02-02 15:23:33,438 INFO OK: read value = false 2026-02-02 15:23:33,438 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false 2026-02-02 15:23:33,438 INFO OK: read value = false 2026-02-02 15:23:33,438 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false 2026-02-02 15:23:33,438 INFO OK: read value = false 2026-02-02 15:23:33,438 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false 2026-02-02 15:23:33,439 INFO OK: read value = false 2026-02-02 15:23:33,439 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false 2026-02-02 15:23:33,439 INFO OK: read value = false 2026-02-02 15:23:33,439 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false 2026-02-02 15:23:33,439 INFO OK: read value = false 2026-02-02 15:23:33,439 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false 2026-02-02 15:23:33,439 INFO OK: read value = false 2026-02-02 15:23:33,439 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false 2026-02-02 15:23:33,439 INFO OK: read value = false 2026-02-02 15:23:33,440 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false 2026-02-02 15:23:33,440 INFO OK: read value = false 2026-02-02 15:23:33,440 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false 2026-02-02 15:23:33,440 INFO OK: read value = false 2026-02-02 15:23:33,441 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false 2026-02-02 15:23:33,441 INFO OK: read value = false 2026-02-02 15:23:33,441 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false 2026-02-02 15:23:33,441 INFO OK: read value = false 2026-02-02 15:23:33,441 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false 2026-02-02 15:23:33,441 INFO OK: read value = false 2026-02-02 15:23:33,441 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false 2026-02-02 15:23:33,442 INFO OK: read value = false 2026-02-02 15:23:33,442 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false 2026-02-02 15:23:33,442 INFO OK: read value = false 2026-02-02 15:23:33,442 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false 2026-02-02 15:23:33,442 INFO OK: read value = false 2026-02-02 15:23:33,442 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false 2026-02-02 15:23:33,442 INFO OK: read value = false 2026-02-02 15:23:33,442 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false 2026-02-02 15:23:33,443 INFO OK: read value = false 2026-02-02 15:23:33,443 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false 2026-02-02 15:23:33,443 INFO OK: read value = false 2026-02-02 15:23:33,444 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false 2026-02-02 15:23:33,444 INFO OK: read value = false 2026-02-02 15:23:33,444 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false 2026-02-02 15:23:33,444 INFO OK: read value = false 2026-02-02 15:23:33,444 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false 2026-02-02 15:23:33,444 INFO OK: read value = false 2026-02-02 15:23:33,444 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false 2026-02-02 15:23:33,444 INFO OK: read value = false 2026-02-02 15:23:33,444 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false 2026-02-02 15:23:33,445 INFO OK: read value = false 2026-02-02 15:23:33,445 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false 2026-02-02 15:23:33,446 INFO OK: read value = false 2026-02-02 15:23:33,446 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false 2026-02-02 15:23:33,447 INFO OK: read value = false 2026-02-02 15:23:33,447 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false 2026-02-02 15:23:33,447 INFO OK: read value = false 2026-02-02 15:23:33,448 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false 2026-02-02 15:23:33,448 INFO OK: read value = false 2026-02-02 15:23:33,448 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false 2026-02-02 15:23:33,448 INFO OK: read value = false 2026-02-02 15:23:33,448 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false 2026-02-02 15:23:33,448 INFO OK: read value = false 2026-02-02 15:23:33,448 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false 2026-02-02 15:23:33,448 INFO OK: read value = false 2026-02-02 15:23:33,448 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false 2026-02-02 15:23:33,449 INFO OK: read value = false 2026-02-02 15:23:33,449 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false 2026-02-02 15:23:33,449 INFO OK: read value = false 2026-02-02 15:23:33,449 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false 2026-02-02 15:23:33,449 INFO OK: read value = false 2026-02-02 15:23:33,450 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false 2026-02-02 15:23:33,450 INFO OK: read value = false 2026-02-02 15:23:33,450 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false 2026-02-02 15:23:33,450 INFO OK: read value = false 2026-02-02 15:23:33,450 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false 2026-02-02 15:23:33,450 INFO OK: read value = false 2026-02-02 15:23:33,450 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false 2026-02-02 15:23:33,450 INFO OK: read value = false 2026-02-02 15:23:33,451 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false 2026-02-02 15:23:33,451 INFO OK: read value = false 2026-02-02 15:23:33,453 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false 2026-02-02 15:23:33,453 INFO OK: read value = false 2026-02-02 15:23:33,453 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false 2026-02-02 15:23:33,454 INFO OK: read value = false 2026-02-02 15:23:33,454 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false 2026-02-02 15:23:33,454 INFO OK: read value = false 2026-02-02 15:23:33,455 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false 2026-02-02 15:23:33,455 INFO OK: read value = false 2026-02-02 15:23:33,455 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false 2026-02-02 15:23:33,456 INFO OK: read value = false 2026-02-02 15:23:33,456 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false 2026-02-02 15:23:33,456 INFO OK: read value = false 2026-02-02 15:23:33,457 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false 2026-02-02 15:23:33,457 INFO OK: read value = false 2026-02-02 15:23:33,457 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false 2026-02-02 15:23:33,458 INFO OK: read value = false 2026-02-02 15:23:33,458 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false 2026-02-02 15:23:33,458 INFO OK: read value = false 2026-02-02 15:23:33,459 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false 2026-02-02 15:23:33,459 INFO OK: read value = false 2026-02-02 15:23:33,459 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,460 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false 2026-02-02 15:23:33,460 INFO OK: read value = false 2026-02-02 15:23:33,462 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false 2026-02-02 15:23:33,462 INFO OK: read value = false 2026-02-02 15:23:33,462 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false 2026-02-02 15:23:33,462 INFO OK: read value = false 2026-02-02 15:23:33,462 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false 2026-02-02 15:23:33,462 INFO OK: read value = false 2026-02-02 15:23:33,462 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false 2026-02-02 15:23:33,462 INFO OK: read value = false 2026-02-02 15:23:33,463 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false 2026-02-02 15:23:33,463 INFO OK: read value = false 2026-02-02 15:23:33,463 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false 2026-02-02 15:23:33,463 INFO OK: read value = false 2026-02-02 15:23:33,463 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false 2026-02-02 15:23:33,463 INFO OK: read value = false 2026-02-02 15:23:33,463 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false 2026-02-02 15:23:33,463 INFO OK: read value = false 2026-02-02 15:23:33,463 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false 2026-02-02 15:23:33,463 INFO OK: read value = false 2026-02-02 15:23:33,464 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false 2026-02-02 15:23:33,464 INFO OK: read value = false 2026-02-02 15:23:33,464 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false 2026-02-02 15:23:33,464 INFO OK: read value = false 2026-02-02 15:23:33,464 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false 2026-02-02 15:23:33,465 DEBUG [MOCK] Field warning: true 2026-02-02 15:23:33,465 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:33,465 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:33,465 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false 2026-02-02 15:23:33,466 DEBUG [MOCK] Field current: true 2026-02-02 15:23:33,466 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:33,466 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:33,466 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false 2026-02-02 15:23:33,466 DEBUG [MOCK] Field arc: true 2026-02-02 15:23:33,466 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:33,467 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:33,467 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false 2026-02-02 15:23:33,467 INFO OK: read value = false 2026-02-02 15:23:33,468 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false 2026-02-02 15:23:33,468 INFO OK: read value = false 2026-02-02 15:23:33,468 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false 2026-02-02 15:23:33,468 INFO OK: read value = false 2026-02-02 15:23:33,468 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false 2026-02-02 15:23:33,468 INFO OK: read value = false 2026-02-02 15:23:33,468 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false 2026-02-02 15:23:33,468 INFO OK: read value = false 2026-02-02 15:23:33,469 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false 2026-02-02 15:23:33,469 INFO OK: read value = false 2026-02-02 15:23:33,469 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false 2026-02-02 15:23:33,469 INFO OK: read value = false 2026-02-02 15:23:33,470 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false 2026-02-02 15:23:33,470 INFO OK: read value = false 2026-02-02 15:23:33,470 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false 2026-02-02 15:23:33,470 INFO OK: read value = false 2026-02-02 15:23:33,471 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false 2026-02-02 15:23:33,471 INFO OK: read value = false 2026-02-02 15:23:33,471 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false 2026-02-02 15:23:33,471 INFO OK: read value = false 2026-02-02 15:23:33,471 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false 2026-02-02 15:23:33,471 INFO OK: read value = false 2026-02-02 15:23:33,471 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false 2026-02-02 15:23:33,471 INFO OK: read value = false 2026-02-02 15:23:33,472 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false 2026-02-02 15:23:33,472 INFO OK: read value = false 2026-02-02 15:23:33,472 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false 2026-02-02 15:23:33,472 INFO OK: read value = false 2026-02-02 15:23:33,473 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false 2026-02-02 15:23:33,473 INFO OK: read value = false 2026-02-02 15:23:33,473 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false 2026-02-02 15:23:33,473 INFO OK: read value = false 2026-02-02 15:23:33,473 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false 2026-02-02 15:23:33,473 INFO OK: read value = false 2026-02-02 15:23:33,473 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false 2026-02-02 15:23:33,473 INFO OK: read value = false 2026-02-02 15:23:33,474 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false 2026-02-02 15:23:33,474 INFO OK: read value = false 2026-02-02 15:23:33,474 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false 2026-02-02 15:23:33,474 INFO OK: read value = false 2026-02-02 15:23:33,474 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false 2026-02-02 15:23:33,474 INFO OK: read value = false 2026-02-02 15:23:33,475 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false 2026-02-02 15:23:33,475 INFO OK: read value = false 2026-02-02 15:23:33,475 WARNING B8_Test_Transmitter: 3/26 failures 2026-02-02 15:23:33,476 INFO [Run 1] B8 Diagnostics: 173 checked, 169 pass, 4 fail 2026-02-02 15:23:33,476 WARNING B8_Degradation: 1 failures - fail 2026-02-02 15:23:33,477 WARNING B8_Test_Transmitter: 3 failures - warning, current, arc 2026-02-02 15:23:33,477 INFO 0.0s remaining ... 2026-02-02 15:23:33,477 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles 2026-02-02 15:23:33,479 INFO Target Detection Test 2026-02-02 15:23:33,479 INFO [Run 1] Starting target detection test (timeout: 5.0s) 2026-02-02 15:23:33,479 INFO tgt_gen() - timeout: 5.0s 2026-02-02 15:23:33,499 INFO TgtMsg: 1 1 2026-02-02 15:23:33,500 INFO Tgt: 1 @ 1180 2026-02-02 15:23:33,500 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 15:23:33,500 INFO OK: read value = 1 2026-02-02 15:23:33,500 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 15:23:33,501 INFO OK: read value = 1180 2026-02-02 15:23:33,501 INFO Target detected successfully in 0.02s 2026-02-02 15:23:33,501 INFO [Run 1] Target DETECTED in 0.02s 2026-02-02 15:23:33,501 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3 Total Step 194: Success 187 (96.39%), Failed 7 (3.61%), 2026-02-02 15:23:33,502 INFO Repetition 2 of 3 2026-02-02 15:23:33,502 DEBUG [MOCK] Serial statistics reset 2026-02-02 15:23:33,502 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 15:23:34,508 INFO Set MAIN_POWER to False 2026-02-02 15:23:34,508 INFO [MOCK] Power OFF 2026-02-02 15:23:34,508 INFO [MOCK] 1553 Interface stopped 2026-02-02 15:23:39,509 INFO Check that MAIN_POWER is equal to 0 2026-02-02 15:23:39,510 INFO OK: read value = False 2026-02-02 15:23:43,525 INFO The test operator is required to switch on the target. 2026-02-02 15:23:43,525 INFO Set MAIN_POWER to True 2026-02-02 15:23:43,525 INFO [MOCK] Power ON 2026-02-02 15:23:43,526 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 15:23:43,526 INFO run_count = 2 2026-02-02 15:23:43,526 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 15:23:43,526 INFO current_scenario = 'mixed' 2026-02-02 15:23:43,526 INFO _scenario_list = ['tx_tests_fail', 'sp_tests_fail', 'normal'] 2026-02-02 15:23:43,527 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 15:23:43,527 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='sp_tests_fail' 2026-02-02 15:23:43,527 INFO [DEBUG] About to call _log_scenario_info('sp_tests_fail', 2, 3) 2026-02-02 15:23:43,527 INFO 2026-02-02 15:23:43,527 INFO #################################################################################################### 2026-02-02 15:23:43,527 INFO #################################################################################################### 2026-02-02 15:23:43,528 INFO ### RUN 2/3: SIGNAL PROCESSOR TEST FAILURES 2026-02-02 15:23:43,528 INFO #################################################################################################### 2026-02-02 15:23:43,528 INFO 2026-02-02 15:23:43,528 INFO SCENARIO: sp_tests_fail 2026-02-02 15:23:43,528 INFO DESCRIPTION: Individual SP tests fail (SP1, SP2, SP3) 2026-02-02 15:23:43,528 INFO 2026-02-02 15:23:43,528 INFO EXPECTED FAILURES: 2026-02-02 15:23:43,528 INFO ✗ B8: test_sp1_timer1_up = FAIL 2026-02-02 15:23:43,528 INFO ✗ B8: test_sp2_timer_dma_pxc_if = FAIL 2026-02-02 15:23:43,528 INFO ✗ B8: test_sp3_timer_internal = FAIL 2026-02-02 15:23:43,529 INFO 2026-02-02 15:23:43,529 INFO EXPECTED PASSES: 2026-02-02 15:23:43,529 INFO ✓ B6 status fields (except processor) 2026-02-02 15:23:43,529 INFO ✓ Other B8 tests 2026-02-02 15:23:43,529 INFO 2026-02-02 15:23:43,529 INFO NOTES: Demonstrates granular test failure analysis - specific SP component failures 2026-02-02 15:23:43,529 INFO 2026-02-02 15:23:43,530 INFO #################################################################################################### 2026-02-02 15:23:43,530 INFO #################################################################################################### 2026-02-02 15:23:43,530 INFO 2026-02-02 15:23:43,530 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 15:23:43,530 INFO [MOCK APPLY] ✗ Setting processor_status = FAIL 2026-02-02 15:23:43,530 INFO [MOCK APPLY] ✗ B8 failures: SP1 (timer1_up), SP2 (timer_dma_pxc_if), SP3 (timer_internal) 2026-02-02 15:23:43,530 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2) 2026-02-02 15:23:48,540 INFO Check that MAIN_POWER is equal to 1 2026-02-02 15:23:48,540 INFO OK: read value = True 2026-02-02 15:23:48,650 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 15:23:48,853 INFO [MOCK] BIT report available after 5.3s 2026-02-02 15:23:48,884 INFO BIT report available after 0.2s 2026-02-02 15:23:48,884 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false 2026-02-02 15:23:48,884 INFO OK: read value = false 2026-02-02 15:23:48,885 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false 2026-02-02 15:23:48,885 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:48,885 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:48,885 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status 2026-02-02 15:23:48,886 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false 2026-02-02 15:23:48,886 INFO OK: read value = false 2026-02-02 15:23:48,886 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false 2026-02-02 15:23:48,886 INFO OK: read value = false 2026-02-02 15:23:48,887 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false 2026-02-02 15:23:48,887 DEBUG [MOCK] Field status: true 2026-02-02 15:23:48,887 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:48,887 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:48,887 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false 2026-02-02 15:23:48,887 INFO OK: read value = false 2026-02-02 15:23:48,887 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false 2026-02-02 15:23:48,888 INFO OK: read value = false 2026-02-02 15:23:48,889 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false 2026-02-02 15:23:48,889 INFO OK: read value = false 2026-02-02 15:23:48,889 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false 2026-02-02 15:23:48,889 INFO OK: read value = false 2026-02-02 15:23:48,890 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false 2026-02-02 15:23:48,890 INFO OK: read value = false 2026-02-02 15:23:48,890 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false 2026-02-02 15:23:48,891 INFO OK: read value = false 2026-02-02 15:23:48,891 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false 2026-02-02 15:23:48,891 DEBUG [MOCK] Field status: RDR_FAIL 2026-02-02 15:23:48,892 WARNING CHECK ERROR: read value = RDR_FAIL 2026-02-02 15:23:48,892 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL 2026-02-02 15:23:48,892 WARNING Radar fail status: REAL failure (caused by: status, status) 2026-02-02 15:23:48,893 INFO [Run 2] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known 2026-02-02 15:23:48,893 INFO Known failures (HW setup): 1 2026-02-02 15:23:48,893 WARNING Real failures: status, status 2026-02-02 15:23:48,893 INFO Drill-down: Verifying all 173 B8 diagnostic fields... 2026-02-02 15:23:48,893 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false 2026-02-02 15:23:48,893 INFO OK: read value = false 2026-02-02 15:23:48,893 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false 2026-02-02 15:23:48,893 INFO OK: read value = false 2026-02-02 15:23:48,893 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false 2026-02-02 15:23:48,894 INFO OK: read value = false 2026-02-02 15:23:48,894 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false 2026-02-02 15:23:48,894 INFO OK: read value = false 2026-02-02 15:23:48,894 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false 2026-02-02 15:23:48,894 INFO OK: read value = false 2026-02-02 15:23:48,894 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false 2026-02-02 15:23:48,894 INFO OK: read value = false 2026-02-02 15:23:48,894 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false 2026-02-02 15:23:48,895 INFO OK: read value = false 2026-02-02 15:23:48,895 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false 2026-02-02 15:23:48,895 INFO OK: read value = false 2026-02-02 15:23:48,895 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false 2026-02-02 15:23:48,895 INFO OK: read value = false 2026-02-02 15:23:48,895 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false 2026-02-02 15:23:48,895 WARNING CHECK ERROR: read value = 0 2026-02-02 15:23:48,895 ERROR INTERFACE ERROR: Expected false, got 0 2026-02-02 15:23:48,896 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false 2026-02-02 15:23:48,896 INFO OK: read value = false 2026-02-02 15:23:48,896 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false 2026-02-02 15:23:48,896 INFO OK: read value = false 2026-02-02 15:23:48,896 WARNING B8_Degradation: 1/12 failures 2026-02-02 15:23:48,896 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false 2026-02-02 15:23:48,896 INFO OK: read value = false 2026-02-02 15:23:48,896 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false 2026-02-02 15:23:48,896 INFO OK: read value = false 2026-02-02 15:23:48,896 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false 2026-02-02 15:23:48,897 INFO OK: read value = false 2026-02-02 15:23:48,897 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false 2026-02-02 15:23:48,897 INFO OK: read value = false 2026-02-02 15:23:48,897 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false 2026-02-02 15:23:48,897 INFO OK: read value = false 2026-02-02 15:23:48,897 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false 2026-02-02 15:23:48,897 INFO OK: read value = false 2026-02-02 15:23:48,897 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false 2026-02-02 15:23:48,897 INFO OK: read value = false 2026-02-02 15:23:48,897 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false 2026-02-02 15:23:48,897 INFO OK: read value = false 2026-02-02 15:23:48,898 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false 2026-02-02 15:23:48,898 INFO OK: read value = false 2026-02-02 15:23:48,898 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false 2026-02-02 15:23:48,898 INFO OK: read value = false 2026-02-02 15:23:48,898 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false 2026-02-02 15:23:48,898 INFO OK: read value = false 2026-02-02 15:23:48,898 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false 2026-02-02 15:23:48,898 INFO OK: read value = false 2026-02-02 15:23:48,898 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false 2026-02-02 15:23:48,899 INFO OK: read value = false 2026-02-02 15:23:48,899 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false 2026-02-02 15:23:48,899 INFO OK: read value = false 2026-02-02 15:23:48,899 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false 2026-02-02 15:23:48,899 INFO OK: read value = false 2026-02-02 15:23:48,899 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false 2026-02-02 15:23:48,899 INFO OK: read value = false 2026-02-02 15:23:48,899 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false 2026-02-02 15:23:48,899 INFO OK: read value = false 2026-02-02 15:23:48,899 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false 2026-02-02 15:23:48,899 INFO OK: read value = false 2026-02-02 15:23:48,900 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false 2026-02-02 15:23:48,900 INFO OK: read value = false 2026-02-02 15:23:48,900 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false 2026-02-02 15:23:48,900 INFO OK: read value = false 2026-02-02 15:23:48,900 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false 2026-02-02 15:23:48,900 INFO OK: read value = false 2026-02-02 15:23:48,900 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false 2026-02-02 15:23:48,901 INFO OK: read value = false 2026-02-02 15:23:48,901 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false 2026-02-02 15:23:48,901 INFO OK: read value = false 2026-02-02 15:23:48,901 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false 2026-02-02 15:23:48,902 INFO OK: read value = false 2026-02-02 15:23:48,902 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false 2026-02-02 15:23:48,902 INFO OK: read value = false 2026-02-02 15:23:48,902 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false 2026-02-02 15:23:48,902 INFO OK: read value = false 2026-02-02 15:23:48,902 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false 2026-02-02 15:23:48,903 INFO OK: read value = false 2026-02-02 15:23:48,903 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false 2026-02-02 15:23:48,903 INFO OK: read value = false 2026-02-02 15:23:48,903 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false 2026-02-02 15:23:48,903 INFO OK: read value = false 2026-02-02 15:23:48,903 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false 2026-02-02 15:23:48,903 INFO OK: read value = false 2026-02-02 15:23:48,903 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false 2026-02-02 15:23:48,903 INFO OK: read value = false 2026-02-02 15:23:48,903 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false 2026-02-02 15:23:48,903 INFO OK: read value = false 2026-02-02 15:23:48,904 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false 2026-02-02 15:23:48,904 INFO OK: read value = false 2026-02-02 15:23:48,904 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false 2026-02-02 15:23:48,904 INFO OK: read value = false 2026-02-02 15:23:48,904 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false 2026-02-02 15:23:48,904 INFO OK: read value = false 2026-02-02 15:23:48,905 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false 2026-02-02 15:23:48,905 INFO OK: read value = false 2026-02-02 15:23:48,905 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false 2026-02-02 15:23:48,905 INFO OK: read value = false 2026-02-02 15:23:48,906 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false 2026-02-02 15:23:48,906 INFO OK: read value = false 2026-02-02 15:23:48,906 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false 2026-02-02 15:23:48,906 INFO OK: read value = false 2026-02-02 15:23:48,906 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false 2026-02-02 15:23:48,907 INFO OK: read value = false 2026-02-02 15:23:48,907 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false 2026-02-02 15:23:48,907 INFO OK: read value = false 2026-02-02 15:23:48,907 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false 2026-02-02 15:23:48,907 INFO OK: read value = false 2026-02-02 15:23:48,908 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false 2026-02-02 15:23:48,908 INFO OK: read value = false 2026-02-02 15:23:48,908 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false 2026-02-02 15:23:48,908 INFO OK: read value = false 2026-02-02 15:23:48,908 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false 2026-02-02 15:23:48,909 INFO OK: read value = false 2026-02-02 15:23:48,909 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false 2026-02-02 15:23:48,909 INFO OK: read value = false 2026-02-02 15:23:48,909 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false 2026-02-02 15:23:48,909 INFO OK: read value = false 2026-02-02 15:23:48,909 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false 2026-02-02 15:23:48,910 INFO OK: read value = false 2026-02-02 15:23:48,910 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false 2026-02-02 15:23:48,910 INFO OK: read value = false 2026-02-02 15:23:48,910 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false 2026-02-02 15:23:48,911 INFO OK: read value = false 2026-02-02 15:23:48,911 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false 2026-02-02 15:23:48,911 INFO OK: read value = false 2026-02-02 15:23:48,911 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false 2026-02-02 15:23:48,911 INFO OK: read value = false 2026-02-02 15:23:48,911 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false 2026-02-02 15:23:48,911 INFO OK: read value = false 2026-02-02 15:23:48,912 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false 2026-02-02 15:23:48,912 INFO OK: read value = false 2026-02-02 15:23:48,912 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false 2026-02-02 15:23:48,912 INFO OK: read value = false 2026-02-02 15:23:48,912 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false 2026-02-02 15:23:48,912 INFO OK: read value = false 2026-02-02 15:23:48,913 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false 2026-02-02 15:23:48,913 INFO OK: read value = false 2026-02-02 15:23:48,913 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false 2026-02-02 15:23:48,913 INFO OK: read value = false 2026-02-02 15:23:48,913 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false 2026-02-02 15:23:48,914 INFO OK: read value = false 2026-02-02 15:23:48,914 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false 2026-02-02 15:23:48,914 INFO OK: read value = false 2026-02-02 15:23:48,914 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false 2026-02-02 15:23:48,914 INFO OK: read value = false 2026-02-02 15:23:48,915 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false 2026-02-02 15:23:48,915 INFO OK: read value = false 2026-02-02 15:23:48,915 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false 2026-02-02 15:23:48,916 INFO OK: read value = false 2026-02-02 15:23:48,916 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false 2026-02-02 15:23:48,916 INFO OK: read value = false 2026-02-02 15:23:48,916 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false 2026-02-02 15:23:48,916 INFO OK: read value = false 2026-02-02 15:23:48,916 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false 2026-02-02 15:23:48,917 INFO OK: read value = false 2026-02-02 15:23:48,917 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false 2026-02-02 15:23:48,917 INFO OK: read value = false 2026-02-02 15:23:48,918 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false 2026-02-02 15:23:48,918 INFO OK: read value = false 2026-02-02 15:23:48,919 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false 2026-02-02 15:23:48,919 INFO OK: read value = false 2026-02-02 15:23:48,920 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false 2026-02-02 15:23:48,920 INFO OK: read value = false 2026-02-02 15:23:48,920 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false 2026-02-02 15:23:48,921 INFO OK: read value = false 2026-02-02 15:23:48,921 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false 2026-02-02 15:23:48,922 INFO OK: read value = false 2026-02-02 15:23:48,922 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false 2026-02-02 15:23:48,922 INFO OK: read value = false 2026-02-02 15:23:48,923 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false 2026-02-02 15:23:48,923 INFO OK: read value = false 2026-02-02 15:23:48,923 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false 2026-02-02 15:23:48,924 INFO OK: read value = false 2026-02-02 15:23:48,924 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false 2026-02-02 15:23:48,924 INFO OK: read value = false 2026-02-02 15:23:48,924 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false 2026-02-02 15:23:48,925 INFO OK: read value = false 2026-02-02 15:23:48,925 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false 2026-02-02 15:23:48,925 INFO OK: read value = false 2026-02-02 15:23:48,925 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false 2026-02-02 15:23:48,925 INFO OK: read value = false 2026-02-02 15:23:48,925 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false 2026-02-02 15:23:48,926 INFO OK: read value = false 2026-02-02 15:23:48,926 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false 2026-02-02 15:23:48,926 INFO OK: read value = false 2026-02-02 15:23:48,926 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false 2026-02-02 15:23:48,926 INFO OK: read value = false 2026-02-02 15:23:48,926 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false 2026-02-02 15:23:48,926 INFO OK: read value = false 2026-02-02 15:23:48,927 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false 2026-02-02 15:23:48,927 INFO OK: read value = false 2026-02-02 15:23:48,927 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false 2026-02-02 15:23:48,927 INFO OK: read value = false 2026-02-02 15:23:48,927 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false 2026-02-02 15:23:48,927 INFO OK: read value = false 2026-02-02 15:23:48,927 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false 2026-02-02 15:23:48,927 INFO OK: read value = false 2026-02-02 15:23:48,928 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false 2026-02-02 15:23:48,928 INFO OK: read value = false 2026-02-02 15:23:48,928 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false 2026-02-02 15:23:48,928 INFO OK: read value = false 2026-02-02 15:23:48,928 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false 2026-02-02 15:23:48,928 INFO OK: read value = false 2026-02-02 15:23:48,930 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false 2026-02-02 15:23:48,930 INFO OK: read value = false 2026-02-02 15:23:48,930 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false 2026-02-02 15:23:48,930 INFO OK: read value = false 2026-02-02 15:23:48,931 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false 2026-02-02 15:23:48,931 INFO OK: read value = false 2026-02-02 15:23:48,931 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false 2026-02-02 15:23:48,931 INFO OK: read value = false 2026-02-02 15:23:48,931 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false 2026-02-02 15:23:48,932 INFO OK: read value = false 2026-02-02 15:23:48,932 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false 2026-02-02 15:23:48,932 INFO OK: read value = false 2026-02-02 15:23:48,932 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false 2026-02-02 15:23:48,932 INFO OK: read value = false 2026-02-02 15:23:48,933 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false 2026-02-02 15:23:48,933 INFO OK: read value = false 2026-02-02 15:23:48,933 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false 2026-02-02 15:23:48,933 INFO OK: read value = false 2026-02-02 15:23:48,933 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false 2026-02-02 15:23:48,933 INFO OK: read value = false 2026-02-02 15:23:48,933 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false 2026-02-02 15:23:48,933 INFO OK: read value = false 2026-02-02 15:23:48,933 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false 2026-02-02 15:23:48,934 INFO OK: read value = false 2026-02-02 15:23:48,934 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false 2026-02-02 15:23:48,934 INFO OK: read value = false 2026-02-02 15:23:48,934 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false 2026-02-02 15:23:48,934 INFO OK: read value = false 2026-02-02 15:23:48,934 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false 2026-02-02 15:23:48,934 INFO OK: read value = false 2026-02-02 15:23:48,935 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false 2026-02-02 15:23:48,935 INFO OK: read value = false 2026-02-02 15:23:48,935 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false 2026-02-02 15:23:48,935 INFO OK: read value = false 2026-02-02 15:23:48,935 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false 2026-02-02 15:23:48,935 INFO OK: read value = false 2026-02-02 15:23:48,935 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false 2026-02-02 15:23:48,935 INFO OK: read value = false 2026-02-02 15:23:48,935 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false 2026-02-02 15:23:48,935 INFO OK: read value = false 2026-02-02 15:23:48,936 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false 2026-02-02 15:23:48,936 INFO OK: read value = false 2026-02-02 15:23:48,936 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false 2026-02-02 15:23:48,936 INFO OK: read value = false 2026-02-02 15:23:48,936 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false 2026-02-02 15:23:48,936 INFO OK: read value = false 2026-02-02 15:23:48,937 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false 2026-02-02 15:23:48,937 INFO OK: read value = false 2026-02-02 15:23:48,937 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false 2026-02-02 15:23:48,938 INFO OK: read value = false 2026-02-02 15:23:48,940 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false 2026-02-02 15:23:48,940 INFO OK: read value = false 2026-02-02 15:23:48,940 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false 2026-02-02 15:23:48,940 INFO OK: read value = false 2026-02-02 15:23:48,940 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false 2026-02-02 15:23:48,940 INFO OK: read value = false 2026-02-02 15:23:48,940 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false 2026-02-02 15:23:48,940 INFO OK: read value = false 2026-02-02 15:23:48,942 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false 2026-02-02 15:23:48,942 INFO OK: read value = false 2026-02-02 15:23:48,943 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false 2026-02-02 15:23:48,943 INFO OK: read value = false 2026-02-02 15:23:48,943 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false 2026-02-02 15:23:48,943 INFO OK: read value = false 2026-02-02 15:23:48,943 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false 2026-02-02 15:23:48,943 INFO OK: read value = false 2026-02-02 15:23:48,943 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false 2026-02-02 15:23:48,943 INFO OK: read value = false 2026-02-02 15:23:48,943 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false 2026-02-02 15:23:48,944 INFO OK: read value = false 2026-02-02 15:23:48,944 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false 2026-02-02 15:23:48,944 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:48,944 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:48,945 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false 2026-02-02 15:23:48,945 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:48,945 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:48,945 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false 2026-02-02 15:23:48,945 WARNING CHECK ERROR: read value = true 2026-02-02 15:23:48,945 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:23:48,946 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false 2026-02-02 15:23:48,946 INFO OK: read value = false 2026-02-02 15:23:48,946 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false 2026-02-02 15:23:48,946 INFO OK: read value = false 2026-02-02 15:23:48,947 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false 2026-02-02 15:23:48,947 INFO OK: read value = false 2026-02-02 15:23:48,947 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false 2026-02-02 15:23:48,947 INFO OK: read value = false 2026-02-02 15:23:48,947 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false 2026-02-02 15:23:48,947 INFO OK: read value = false 2026-02-02 15:23:48,947 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false 2026-02-02 15:23:48,947 INFO OK: read value = false 2026-02-02 15:23:48,947 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false 2026-02-02 15:23:48,949 INFO OK: read value = false 2026-02-02 15:23:48,949 WARNING B8_Test_SignalProcessor: 3/14 failures 2026-02-02 15:23:48,949 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false 2026-02-02 15:23:48,949 INFO OK: read value = false 2026-02-02 15:23:48,949 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false 2026-02-02 15:23:48,951 INFO OK: read value = false 2026-02-02 15:23:48,951 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false 2026-02-02 15:23:48,951 INFO OK: read value = false 2026-02-02 15:23:48,951 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false 2026-02-02 15:23:48,951 INFO OK: read value = false 2026-02-02 15:23:48,951 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false 2026-02-02 15:23:48,951 INFO OK: read value = false 2026-02-02 15:23:48,951 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false 2026-02-02 15:23:48,951 INFO OK: read value = false 2026-02-02 15:23:48,951 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false 2026-02-02 15:23:48,952 INFO OK: read value = false 2026-02-02 15:23:48,952 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false 2026-02-02 15:23:48,952 INFO OK: read value = false 2026-02-02 15:23:48,952 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false 2026-02-02 15:23:48,952 INFO OK: read value = false 2026-02-02 15:23:48,952 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false 2026-02-02 15:23:48,952 INFO OK: read value = false 2026-02-02 15:23:48,952 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false 2026-02-02 15:23:48,953 INFO OK: read value = false 2026-02-02 15:23:48,953 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false 2026-02-02 15:23:48,953 INFO OK: read value = false 2026-02-02 15:23:48,953 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false 2026-02-02 15:23:48,953 INFO OK: read value = false 2026-02-02 15:23:48,953 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false 2026-02-02 15:23:48,953 INFO OK: read value = false 2026-02-02 15:23:48,953 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false 2026-02-02 15:23:48,953 INFO OK: read value = false 2026-02-02 15:23:48,954 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false 2026-02-02 15:23:48,954 INFO OK: read value = false 2026-02-02 15:23:48,954 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false 2026-02-02 15:23:48,954 INFO OK: read value = false 2026-02-02 15:23:48,954 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false 2026-02-02 15:23:48,954 INFO OK: read value = false 2026-02-02 15:23:48,954 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false 2026-02-02 15:23:48,954 INFO OK: read value = false 2026-02-02 15:23:48,954 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false 2026-02-02 15:23:48,955 INFO OK: read value = false 2026-02-02 15:23:48,955 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false 2026-02-02 15:23:48,955 INFO OK: read value = false 2026-02-02 15:23:48,955 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false 2026-02-02 15:23:48,955 INFO OK: read value = false 2026-02-02 15:23:48,955 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false 2026-02-02 15:23:48,955 INFO OK: read value = false 2026-02-02 15:23:48,955 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false 2026-02-02 15:23:48,955 INFO OK: read value = false 2026-02-02 15:23:48,955 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false 2026-02-02 15:23:48,955 INFO OK: read value = false 2026-02-02 15:23:48,956 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false 2026-02-02 15:23:48,956 INFO OK: read value = false 2026-02-02 15:23:48,956 INFO [Run 2] B8 Diagnostics: 173 checked, 169 pass, 4 fail 2026-02-02 15:23:48,956 WARNING B8_Degradation: 1 failures - fail 2026-02-02 15:23:48,956 WARNING B8_Test_SignalProcessor: 3 failures - up, if, internal 2026-02-02 15:23:48,956 INFO 0.0s remaining ... 2026-02-02 15:23:48,956 INFO [Run 2] Serial: 0 total, 0 errors, 0 fatal, 0 recycles 2026-02-02 15:23:48,957 INFO Target Detection Test 2026-02-02 15:23:48,957 INFO [Run 2] Starting target detection test (timeout: 5.0s) 2026-02-02 15:23:48,957 INFO tgt_gen() - timeout: 5.0s 2026-02-02 15:23:48,977 INFO TgtMsg: 2 2 2026-02-02 15:23:48,977 INFO Tgt: 1 @ 1180 2026-02-02 15:23:48,977 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 15:23:48,977 DEBUG [MOCK] Field num: 1 2026-02-02 15:23:48,977 INFO OK: read value = 1 2026-02-02 15:23:48,977 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 15:23:48,977 INFO OK: read value = 1180 2026-02-02 15:23:48,978 INFO Target detected successfully in 0.02s 2026-02-02 15:23:48,979 INFO [Run 2] Target DETECTED in 0.02s 2026-02-02 15:23:48,980 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3 Total Step 192: Success 185 (96.35%), Failed 7 (3.65%), 2026-02-02 15:23:48,980 INFO Repetition 3 of 3 2026-02-02 15:23:48,980 DEBUG [MOCK] Serial statistics reset 2026-02-02 15:23:48,980 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 15:23:49,982 INFO Set MAIN_POWER to False 2026-02-02 15:23:49,982 INFO [MOCK] Power OFF 2026-02-02 15:23:49,982 INFO [MOCK] 1553 Interface stopped 2026-02-02 15:23:54,996 INFO Check that MAIN_POWER is equal to 0 2026-02-02 15:23:54,996 INFO OK: read value = False 2026-02-02 15:23:58,997 INFO The test operator is required to switch on the target. 2026-02-02 15:23:58,997 INFO Set MAIN_POWER to True 2026-02-02 15:23:58,997 INFO [MOCK] Power ON 2026-02-02 15:23:58,998 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 15:23:58,998 INFO run_count = 3 2026-02-02 15:23:58,998 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 15:23:58,998 INFO current_scenario = 'mixed' 2026-02-02 15:23:58,999 INFO _scenario_list = ['tx_tests_fail', 'sp_tests_fail', 'normal'] 2026-02-02 15:23:59,001 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 15:23:59,001 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='normal' 2026-02-02 15:23:59,001 INFO [DEBUG] About to call _log_scenario_info('normal', 3, 3) 2026-02-02 15:23:59,001 INFO 2026-02-02 15:23:59,001 INFO #################################################################################################### 2026-02-02 15:23:59,001 INFO #################################################################################################### 2026-02-02 15:23:59,001 INFO ### RUN 3/3: NORMAL OPERATION 2026-02-02 15:23:59,001 INFO #################################################################################################### 2026-02-02 15:23:59,002 INFO 2026-02-02 15:23:59,002 INFO SCENARIO: normal 2026-02-02 15:23:59,002 INFO DESCRIPTION: All systems operational - no failures 2026-02-02 15:23:59,002 INFO 2026-02-02 15:23:59,002 INFO EXPECTED FAILURES: 2026-02-02 15:23:59,002 INFO (none) 2026-02-02 15:23:59,002 INFO 2026-02-02 15:23:59,003 INFO EXPECTED PASSES: 2026-02-02 15:23:59,003 INFO ✓ All B6 status fields (except pedestal) 2026-02-02 15:23:59,003 INFO ✓ All B8 diagnostic fields 2026-02-02 15:23:59,004 INFO ✓ Target generation 2026-02-02 15:23:59,004 INFO 2026-02-02 15:23:59,004 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present) 2026-02-02 15:23:59,004 INFO 2026-02-02 15:23:59,004 INFO #################################################################################################### 2026-02-02 15:23:59,004 INFO #################################################################################################### 2026-02-02 15:23:59,004 INFO 2026-02-02 15:23:59,004 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 15:23:59,004 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected) 2026-02-02 15:23:59,004 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3) 2026-02-02 15:24:04,009 INFO Check that MAIN_POWER is equal to 1 2026-02-02 15:24:04,010 INFO OK: read value = True 2026-02-02 15:24:04,112 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 15:24:04,323 INFO [MOCK] BIT report available after 5.3s 2026-02-02 15:24:04,355 INFO BIT report available after 0.2s 2026-02-02 15:24:04,355 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false 2026-02-02 15:24:04,355 INFO OK: read value = false 2026-02-02 15:24:04,355 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false 2026-02-02 15:24:04,355 WARNING CHECK ERROR: read value = true 2026-02-02 15:24:04,356 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 15:24:04,356 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status 2026-02-02 15:24:04,356 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false 2026-02-02 15:24:04,356 INFO OK: read value = false 2026-02-02 15:24:04,356 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false 2026-02-02 15:24:04,356 INFO OK: read value = false 2026-02-02 15:24:04,356 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false 2026-02-02 15:24:04,356 INFO OK: read value = false 2026-02-02 15:24:04,356 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false 2026-02-02 15:24:04,358 INFO OK: read value = false 2026-02-02 15:24:04,358 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false 2026-02-02 15:24:04,358 INFO OK: read value = false 2026-02-02 15:24:04,358 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false 2026-02-02 15:24:04,358 INFO OK: read value = false 2026-02-02 15:24:04,358 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false 2026-02-02 15:24:04,358 INFO OK: read value = false 2026-02-02 15:24:04,359 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false 2026-02-02 15:24:04,359 INFO OK: read value = false 2026-02-02 15:24:04,359 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false 2026-02-02 15:24:04,359 INFO OK: read value = false 2026-02-02 15:24:04,359 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false 2026-02-02 15:24:04,359 WARNING CHECK ERROR: read value = RDR_OK 2026-02-02 15:24:04,359 ERROR INTERFACE ERROR: Expected false, got RDR_OK 2026-02-02 15:24:04,359 WARNING Radar fail status: Known failure (caused only by pedestal) 2026-02-02 15:24:04,359 INFO [Run 3] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known 2026-02-02 15:24:04,359 INFO Known failures (HW setup): 2 2026-02-02 15:24:04,359 INFO Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields... 2026-02-02 15:24:04,359 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures 2026-02-02 15:24:04,359 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false 2026-02-02 15:24:04,359 INFO OK: read value = false 2026-02-02 15:24:04,359 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false 2026-02-02 15:24:04,360 INFO OK: read value = false 2026-02-02 15:24:04,360 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false 2026-02-02 15:24:04,360 INFO OK: read value = false 2026-02-02 15:24:04,360 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false 2026-02-02 15:24:04,360 INFO OK: read value = false 2026-02-02 15:24:04,360 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false 2026-02-02 15:24:04,360 INFO OK: read value = false 2026-02-02 15:24:04,360 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false 2026-02-02 15:24:04,360 INFO OK: read value = false 2026-02-02 15:24:04,360 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false 2026-02-02 15:24:04,361 INFO OK: read value = false 2026-02-02 15:24:04,361 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false 2026-02-02 15:24:04,361 INFO OK: read value = false 2026-02-02 15:24:04,361 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false 2026-02-02 15:24:04,361 INFO OK: read value = false 2026-02-02 15:24:04,361 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false 2026-02-02 15:24:04,361 WARNING CHECK ERROR: read value = 0 2026-02-02 15:24:04,361 ERROR INTERFACE ERROR: Expected false, got 0 2026-02-02 15:24:04,361 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false 2026-02-02 15:24:04,361 INFO OK: read value = false 2026-02-02 15:24:04,361 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false 2026-02-02 15:24:04,362 INFO OK: read value = false 2026-02-02 15:24:04,362 WARNING B8_Degradation: 1/12 failures 2026-02-02 15:24:04,362 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false 2026-02-02 15:24:04,362 INFO OK: read value = false 2026-02-02 15:24:04,362 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false 2026-02-02 15:24:04,362 INFO OK: read value = false 2026-02-02 15:24:04,362 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false 2026-02-02 15:24:04,362 INFO OK: read value = false 2026-02-02 15:24:04,362 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false 2026-02-02 15:24:04,362 INFO OK: read value = false 2026-02-02 15:24:04,362 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false 2026-02-02 15:24:04,363 INFO OK: read value = false 2026-02-02 15:24:04,363 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false 2026-02-02 15:24:04,363 INFO OK: read value = false 2026-02-02 15:24:04,363 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false 2026-02-02 15:24:04,363 INFO OK: read value = false 2026-02-02 15:24:04,363 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false 2026-02-02 15:24:04,363 INFO OK: read value = false 2026-02-02 15:24:04,363 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false 2026-02-02 15:24:04,363 INFO OK: read value = false 2026-02-02 15:24:04,363 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false 2026-02-02 15:24:04,363 INFO OK: read value = false 2026-02-02 15:24:04,364 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false 2026-02-02 15:24:04,364 INFO OK: read value = false 2026-02-02 15:24:04,364 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false 2026-02-02 15:24:04,364 INFO OK: read value = false 2026-02-02 15:24:04,364 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false 2026-02-02 15:24:04,364 INFO OK: read value = false 2026-02-02 15:24:04,364 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false 2026-02-02 15:24:04,364 INFO OK: read value = false 2026-02-02 15:24:04,364 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false 2026-02-02 15:24:04,364 INFO OK: read value = false 2026-02-02 15:24:04,365 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false 2026-02-02 15:24:04,365 INFO OK: read value = false 2026-02-02 15:24:04,365 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false 2026-02-02 15:24:04,365 INFO OK: read value = false 2026-02-02 15:24:04,365 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false 2026-02-02 15:24:04,365 INFO OK: read value = false 2026-02-02 15:24:04,365 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false 2026-02-02 15:24:04,365 INFO OK: read value = false 2026-02-02 15:24:04,365 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false 2026-02-02 15:24:04,365 INFO OK: read value = false 2026-02-02 15:24:04,366 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false 2026-02-02 15:24:04,366 INFO OK: read value = false 2026-02-02 15:24:04,366 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false 2026-02-02 15:24:04,366 INFO OK: read value = false 2026-02-02 15:24:04,366 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false 2026-02-02 15:24:04,366 INFO OK: read value = false 2026-02-02 15:24:04,366 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false 2026-02-02 15:24:04,366 INFO OK: read value = false 2026-02-02 15:24:04,366 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false 2026-02-02 15:24:04,367 INFO OK: read value = false 2026-02-02 15:24:04,367 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false 2026-02-02 15:24:04,367 INFO OK: read value = false 2026-02-02 15:24:04,367 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false 2026-02-02 15:24:04,367 INFO OK: read value = false 2026-02-02 15:24:04,367 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false 2026-02-02 15:24:04,367 INFO OK: read value = false 2026-02-02 15:24:04,367 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false 2026-02-02 15:24:04,367 INFO OK: read value = false 2026-02-02 15:24:04,368 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false 2026-02-02 15:24:04,368 INFO OK: read value = false 2026-02-02 15:24:04,368 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false 2026-02-02 15:24:04,368 INFO OK: read value = false 2026-02-02 15:24:04,368 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false 2026-02-02 15:24:04,368 INFO OK: read value = false 2026-02-02 15:24:04,368 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false 2026-02-02 15:24:04,368 INFO OK: read value = false 2026-02-02 15:24:04,368 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false 2026-02-02 15:24:04,368 INFO OK: read value = false 2026-02-02 15:24:04,368 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false 2026-02-02 15:24:04,369 INFO OK: read value = false 2026-02-02 15:24:04,369 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false 2026-02-02 15:24:04,369 INFO OK: read value = false 2026-02-02 15:24:04,369 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false 2026-02-02 15:24:04,369 INFO OK: read value = false 2026-02-02 15:24:04,369 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false 2026-02-02 15:24:04,369 INFO OK: read value = false 2026-02-02 15:24:04,369 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false 2026-02-02 15:24:04,369 INFO OK: read value = false 2026-02-02 15:24:04,369 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false 2026-02-02 15:24:04,370 INFO OK: read value = false 2026-02-02 15:24:04,370 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false 2026-02-02 15:24:04,370 INFO OK: read value = false 2026-02-02 15:24:04,370 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false 2026-02-02 15:24:04,370 INFO OK: read value = false 2026-02-02 15:24:04,370 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false 2026-02-02 15:24:04,370 INFO OK: read value = false 2026-02-02 15:24:04,370 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false 2026-02-02 15:24:04,371 INFO OK: read value = false 2026-02-02 15:24:04,371 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false 2026-02-02 15:24:04,371 INFO OK: read value = false 2026-02-02 15:24:04,371 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false 2026-02-02 15:24:04,371 INFO OK: read value = false 2026-02-02 15:24:04,371 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false 2026-02-02 15:24:04,371 INFO OK: read value = false 2026-02-02 15:24:04,371 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false 2026-02-02 15:24:04,371 INFO OK: read value = false 2026-02-02 15:24:04,371 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false 2026-02-02 15:24:04,371 INFO OK: read value = false 2026-02-02 15:24:04,372 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false 2026-02-02 15:24:04,372 INFO OK: read value = false 2026-02-02 15:24:04,372 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false 2026-02-02 15:24:04,372 INFO OK: read value = false 2026-02-02 15:24:04,372 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false 2026-02-02 15:24:04,372 INFO OK: read value = false 2026-02-02 15:24:04,372 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false 2026-02-02 15:24:04,372 INFO OK: read value = false 2026-02-02 15:24:04,372 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false 2026-02-02 15:24:04,372 INFO OK: read value = false 2026-02-02 15:24:04,373 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false 2026-02-02 15:24:04,373 INFO OK: read value = false 2026-02-02 15:24:04,373 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false 2026-02-02 15:24:04,373 INFO OK: read value = false 2026-02-02 15:24:04,373 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false 2026-02-02 15:24:04,373 INFO OK: read value = false 2026-02-02 15:24:04,373 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false 2026-02-02 15:24:04,373 INFO OK: read value = false 2026-02-02 15:24:04,373 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false 2026-02-02 15:24:04,373 INFO OK: read value = false 2026-02-02 15:24:04,374 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false 2026-02-02 15:24:04,374 INFO OK: read value = false 2026-02-02 15:24:04,374 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false 2026-02-02 15:24:04,374 INFO OK: read value = false 2026-02-02 15:24:04,374 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false 2026-02-02 15:24:04,374 INFO OK: read value = false 2026-02-02 15:24:04,374 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false 2026-02-02 15:24:04,374 INFO OK: read value = false 2026-02-02 15:24:04,374 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false 2026-02-02 15:24:04,374 INFO OK: read value = false 2026-02-02 15:24:04,375 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false 2026-02-02 15:24:04,375 INFO OK: read value = false 2026-02-02 15:24:04,375 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false 2026-02-02 15:24:04,375 INFO OK: read value = false 2026-02-02 15:24:04,375 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false 2026-02-02 15:24:04,375 INFO OK: read value = false 2026-02-02 15:24:04,375 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false 2026-02-02 15:24:04,375 INFO OK: read value = false 2026-02-02 15:24:04,376 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false 2026-02-02 15:24:04,376 INFO OK: read value = false 2026-02-02 15:24:04,376 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false 2026-02-02 15:24:04,376 INFO OK: read value = false 2026-02-02 15:24:04,376 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false 2026-02-02 15:24:04,376 INFO OK: read value = false 2026-02-02 15:24:04,376 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false 2026-02-02 15:24:04,376 INFO OK: read value = false 2026-02-02 15:24:04,377 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false 2026-02-02 15:24:04,377 INFO OK: read value = false 2026-02-02 15:24:04,377 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false 2026-02-02 15:24:04,377 INFO OK: read value = false 2026-02-02 15:24:04,377 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false 2026-02-02 15:24:04,377 INFO OK: read value = false 2026-02-02 15:24:04,377 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false 2026-02-02 15:24:04,377 INFO OK: read value = false 2026-02-02 15:24:04,377 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false 2026-02-02 15:24:04,377 INFO OK: read value = false 2026-02-02 15:24:04,377 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false 2026-02-02 15:24:04,377 INFO OK: read value = false 2026-02-02 15:24:04,378 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false 2026-02-02 15:24:04,378 INFO OK: read value = false 2026-02-02 15:24:04,378 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false 2026-02-02 15:24:04,378 INFO OK: read value = false 2026-02-02 15:24:04,378 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false 2026-02-02 15:24:04,378 INFO OK: read value = false 2026-02-02 15:24:04,378 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false 2026-02-02 15:24:04,378 INFO OK: read value = false 2026-02-02 15:24:04,378 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false 2026-02-02 15:24:04,378 INFO OK: read value = false 2026-02-02 15:24:04,378 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false 2026-02-02 15:24:04,379 INFO OK: read value = false 2026-02-02 15:24:04,379 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false 2026-02-02 15:24:04,379 INFO OK: read value = false 2026-02-02 15:24:04,379 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false 2026-02-02 15:24:04,379 INFO OK: read value = false 2026-02-02 15:24:04,379 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false 2026-02-02 15:24:04,379 INFO OK: read value = false 2026-02-02 15:24:04,379 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false 2026-02-02 15:24:04,379 INFO OK: read value = false 2026-02-02 15:24:04,380 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false 2026-02-02 15:24:04,380 INFO OK: read value = false 2026-02-02 15:24:04,380 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false 2026-02-02 15:24:04,380 INFO OK: read value = false 2026-02-02 15:24:04,380 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false 2026-02-02 15:24:04,380 INFO OK: read value = false 2026-02-02 15:24:04,380 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false 2026-02-02 15:24:04,380 INFO OK: read value = false 2026-02-02 15:24:04,380 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false 2026-02-02 15:24:04,381 INFO OK: read value = false 2026-02-02 15:24:04,381 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false 2026-02-02 15:24:04,381 INFO OK: read value = false 2026-02-02 15:24:04,381 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false 2026-02-02 15:24:04,381 INFO OK: read value = false 2026-02-02 15:24:04,381 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false 2026-02-02 15:24:04,381 INFO OK: read value = false 2026-02-02 15:24:04,381 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false 2026-02-02 15:24:04,382 INFO OK: read value = false 2026-02-02 15:24:04,382 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false 2026-02-02 15:24:04,382 INFO OK: read value = false 2026-02-02 15:24:04,382 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false 2026-02-02 15:24:04,382 INFO OK: read value = false 2026-02-02 15:24:04,383 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false 2026-02-02 15:24:04,383 INFO OK: read value = false 2026-02-02 15:24:04,383 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false 2026-02-02 15:24:04,383 INFO OK: read value = false 2026-02-02 15:24:04,383 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false 2026-02-02 15:24:04,383 INFO OK: read value = false 2026-02-02 15:24:04,384 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false 2026-02-02 15:24:04,384 INFO OK: read value = false 2026-02-02 15:24:04,384 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false 2026-02-02 15:24:04,384 INFO OK: read value = false 2026-02-02 15:24:04,385 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false 2026-02-02 15:24:04,385 INFO OK: read value = false 2026-02-02 15:24:04,385 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false 2026-02-02 15:24:04,385 INFO OK: read value = false 2026-02-02 15:24:04,386 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false 2026-02-02 15:24:04,386 INFO OK: read value = false 2026-02-02 15:24:04,386 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false 2026-02-02 15:24:04,387 INFO OK: read value = false 2026-02-02 15:24:04,387 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false 2026-02-02 15:24:04,387 INFO OK: read value = false 2026-02-02 15:24:04,387 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false 2026-02-02 15:24:04,389 INFO OK: read value = false 2026-02-02 15:24:04,389 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false 2026-02-02 15:24:04,390 INFO OK: read value = false 2026-02-02 15:24:04,390 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false 2026-02-02 15:24:04,391 INFO OK: read value = false 2026-02-02 15:24:04,391 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false 2026-02-02 15:24:04,391 INFO OK: read value = false 2026-02-02 15:24:04,391 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false 2026-02-02 15:24:04,392 INFO OK: read value = false 2026-02-02 15:24:04,392 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false 2026-02-02 15:24:04,392 INFO OK: read value = false 2026-02-02 15:24:04,392 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false 2026-02-02 15:24:04,393 INFO OK: read value = false 2026-02-02 15:24:04,394 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false 2026-02-02 15:24:04,394 INFO OK: read value = false 2026-02-02 15:24:04,395 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false 2026-02-02 15:24:04,395 INFO OK: read value = false 2026-02-02 15:24:04,395 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false 2026-02-02 15:24:04,395 INFO OK: read value = false 2026-02-02 15:24:04,395 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false 2026-02-02 15:24:04,396 INFO OK: read value = false 2026-02-02 15:24:04,396 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false 2026-02-02 15:24:04,396 INFO OK: read value = false 2026-02-02 15:24:04,396 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false 2026-02-02 15:24:04,396 INFO OK: read value = false 2026-02-02 15:24:04,396 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false 2026-02-02 15:24:04,396 INFO OK: read value = false 2026-02-02 15:24:04,397 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false 2026-02-02 15:24:04,397 INFO OK: read value = false 2026-02-02 15:24:04,397 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false 2026-02-02 15:24:04,397 INFO OK: read value = false 2026-02-02 15:24:04,398 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false 2026-02-02 15:24:04,398 INFO OK: read value = false 2026-02-02 15:24:04,398 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false 2026-02-02 15:24:04,398 INFO OK: read value = false 2026-02-02 15:24:04,398 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false 2026-02-02 15:24:04,398 INFO OK: read value = false 2026-02-02 15:24:04,398 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false 2026-02-02 15:24:04,398 INFO OK: read value = false 2026-02-02 15:24:04,399 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false 2026-02-02 15:24:04,399 INFO OK: read value = false 2026-02-02 15:24:04,399 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false 2026-02-02 15:24:04,399 INFO OK: read value = false 2026-02-02 15:24:04,399 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false 2026-02-02 15:24:04,399 INFO OK: read value = false 2026-02-02 15:24:04,399 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false 2026-02-02 15:24:04,399 INFO OK: read value = false 2026-02-02 15:24:04,400 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false 2026-02-02 15:24:04,400 INFO OK: read value = false 2026-02-02 15:24:04,400 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false 2026-02-02 15:24:04,400 INFO OK: read value = false 2026-02-02 15:24:04,400 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false 2026-02-02 15:24:04,400 INFO OK: read value = false 2026-02-02 15:24:04,401 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false 2026-02-02 15:24:04,401 INFO OK: read value = false 2026-02-02 15:24:04,401 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false 2026-02-02 15:24:04,401 INFO OK: read value = false 2026-02-02 15:24:04,401 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false 2026-02-02 15:24:04,401 INFO OK: read value = false 2026-02-02 15:24:04,401 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false 2026-02-02 15:24:04,402 INFO OK: read value = false 2026-02-02 15:24:04,402 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false 2026-02-02 15:24:04,402 INFO OK: read value = false 2026-02-02 15:24:04,402 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false 2026-02-02 15:24:04,402 INFO OK: read value = false 2026-02-02 15:24:04,402 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false 2026-02-02 15:24:04,402 INFO OK: read value = false 2026-02-02 15:24:04,402 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false 2026-02-02 15:24:04,403 INFO OK: read value = false 2026-02-02 15:24:04,403 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false 2026-02-02 15:24:04,403 INFO OK: read value = false 2026-02-02 15:24:04,403 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false 2026-02-02 15:24:04,403 INFO OK: read value = false 2026-02-02 15:24:04,403 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false 2026-02-02 15:24:04,404 INFO OK: read value = false 2026-02-02 15:24:04,404 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false 2026-02-02 15:24:04,404 INFO OK: read value = false 2026-02-02 15:24:04,404 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false 2026-02-02 15:24:04,405 INFO OK: read value = false 2026-02-02 15:24:04,405 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false 2026-02-02 15:24:04,405 INFO OK: read value = false 2026-02-02 15:24:04,405 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false 2026-02-02 15:24:04,405 INFO OK: read value = false 2026-02-02 15:24:04,405 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false 2026-02-02 15:24:04,405 INFO OK: read value = false 2026-02-02 15:24:04,406 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false 2026-02-02 15:24:04,406 INFO OK: read value = false 2026-02-02 15:24:04,406 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false 2026-02-02 15:24:04,406 INFO OK: read value = false 2026-02-02 15:24:04,406 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false 2026-02-02 15:24:04,406 INFO OK: read value = false 2026-02-02 15:24:04,406 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false 2026-02-02 15:24:04,406 INFO OK: read value = false 2026-02-02 15:24:04,407 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false 2026-02-02 15:24:04,407 INFO OK: read value = false 2026-02-02 15:24:04,407 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false 2026-02-02 15:24:04,407 INFO OK: read value = false 2026-02-02 15:24:04,407 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false 2026-02-02 15:24:04,407 INFO OK: read value = false 2026-02-02 15:24:04,407 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false 2026-02-02 15:24:04,408 INFO OK: read value = false 2026-02-02 15:24:04,408 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false 2026-02-02 15:24:04,408 INFO OK: read value = false 2026-02-02 15:24:04,408 INFO [Run 3] B8 Diagnostics: 173 checked, 172 pass, 1 fail 2026-02-02 15:24:04,408 WARNING B8_Degradation: 1 failures - fail 2026-02-02 15:24:04,408 INFO 0.0s remaining ... 2026-02-02 15:24:04,408 INFO [Run 3] Serial: 0 total, 0 errors, 0 fatal, 0 recycles 2026-02-02 15:24:04,409 INFO Target Detection Test 2026-02-02 15:24:04,409 INFO [Run 3] Starting target detection test (timeout: 5.0s) 2026-02-02 15:24:04,409 INFO tgt_gen() - timeout: 5.0s 2026-02-02 15:24:04,422 INFO TgtMsg: 3 3 2026-02-02 15:24:04,427 INFO Tgt: 1 @ 1180 2026-02-02 15:24:04,428 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 15:24:04,428 INFO OK: read value = 1 2026-02-02 15:24:04,428 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 15:24:04,429 INFO OK: read value = 1180 2026-02-02 15:24:04,429 INFO Target detected successfully in 0.02s 2026-02-02 15:24:04,429 INFO [Run 3] Target DETECTED in 0.02s 2026-02-02 15:24:04,430 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3 Total Step 192: Success 189 (98.44%), Failed 3 (1.56%), 2026-02-02 15:24:04,430 INFO Repetitions terminated. 2026-02-02 15:24:04,430 INFO [Report] Custom statistics data registered for PDF generation 2026-02-02 15:24:04,430 INFO ========================================================================================== 2026-02-02 15:24:04,431 INFO FINAL TEST STATISTICS SUMMARY 2026-02-02 15:24:04,431 INFO ========================================================================================== 2026-02-02 15:24:04,431 INFO Total Runs: 3 2026-02-02 15:24:04,431 INFO Successful: 1 (33.3%) 2026-02-02 15:24:04,431 INFO Failed: 2 (66.7%) 2026-02-02 15:24:04,431 INFO B6 Checks: 36 (Pass: 28, Fail: 4, Known: 4) 2026-02-02 15:24:04,431 INFO B8 Checks: 519 (Pass: 510, Fail: 9) 2026-02-02 15:24:04,431 INFO Serial: 0 messages (0 errors, 0 fatal, 0 recycles) 2026-02-02 15:24:04,431 INFO Target: 3 detected, 0 not detected (100.0% pass rate) 2026-02-02 15:24:04,431 INFO PBIT Timing: avg=0.24s, min=0.23s, max=0.24s, σ=0.00s 2026-02-02 15:24:04,432 INFO ========================================================================================== 2026-02-02 15:24:04,432 INFO Detailed statistics will be available in the PDF report 2026-02-02 15:24:04,432 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_152404_statistics.csv 2026-02-02 15:24:04,439 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_152404_statistics.csv 2026-02-02 15:24:04,445 INFO Statistics exported successfully to JSON: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_152404_statistics.json 2026-02-02 15:24:04,445 INFO Set MAIN_POWER to False 2026-02-02 15:24:04,445 INFO [MOCK] Power OFF 2026-02-02 15:24:04,445 INFO [MOCK] 1553 Interface stopped 2026-02-02 15:24:09,448 INFO Check that MAIN_POWER is equal to 0 2026-02-02 15:24:09,448 INFO OK: read value = False 2026-02-02 15:24:09,449 INFO [MOCK] Serial terminal disconnected 2026-02-02 15:24:09,449 INFO Stop Time: 2026-02-02 15:23:17.298136 2026-02-02 15:24:09,449 INFO Test execution time: 0:00:52.151778