2026-02-02 14:57:25,539 INFO Start Time: 2026-02-02 14:57:25.539620 2026-02-02 14:57:25,540 INFO [MOCK] Serial terminal initialized 2026-02-02 14:57:25,540 INFO [MOCK] Serial terminal connected 2026-02-02 14:57:25,540 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!****** 2026-02-02 14:57:25,540 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ... 2026-02-02 14:57:25,540 INFO [MOCK] Simulating target acquisition: will appear after 2 scan cycles 2026-02-02 14:57:25,550 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 14:57:25,601 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 14:57:25,652 INFO [MOCK] Target simulated at distance 1180 2026-02-02 14:57:25,653 INFO [MOCK] Log started at level 3 in directory: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts 2026-02-02 14:57:25,653 INFO tgt_gen_alone(): 0 2026-02-02 14:57:25,654 INFO tgt_gen() 2026-02-02 14:57:25,664 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 14:57:25,664 INFO TgtMsg: 0 0 2026-02-02 14:57:25,665 INFO Tgt: 1 @ 1180 2026-02-02 14:57:25,665 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 14:57:25,665 INFO OK: read value = 1 2026-02-02 14:57:25,665 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 14:57:25,666 INFO OK: read value = 1180 2026-02-02 14:57:25,666 INFO [MOCK] Log stopped 2026-02-02 14:57:25,666 INFO Repetition 1 of 2 2026-02-02 14:57:25,667 DEBUG [MOCK] Serial statistics reset 2026-02-02 14:57:25,667 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 14:57:26,667 INFO Set MAIN_POWER to False 2026-02-02 14:57:26,668 INFO [MOCK] Power OFF 2026-02-02 14:57:26,669 INFO [MOCK] 1553 Interface stopped 2026-02-02 14:57:31,670 INFO Check that MAIN_POWER is equal to 0 2026-02-02 14:57:31,670 INFO OK: read value = False 2026-02-02 14:57:35,673 INFO The test operator is required to switch on the target. 2026-02-02 14:57:35,674 INFO Set MAIN_POWER to True 2026-02-02 14:57:35,674 INFO [MOCK] Power ON 2026-02-02 14:57:35,675 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 14:57:35,675 INFO run_count = 1 2026-02-02 14:57:35,675 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 14:57:35,675 INFO current_scenario = 'mixed' 2026-02-02 14:57:35,675 INFO _scenario_list = ['normal', 'normal'] 2026-02-02 14:57:35,675 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 14:57:35,675 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='normal' 2026-02-02 14:57:35,676 INFO [DEBUG] About to call _log_scenario_info('normal', 1, 2) 2026-02-02 14:57:35,676 INFO 2026-02-02 14:57:35,676 INFO #################################################################################################### 2026-02-02 14:57:35,676 INFO #################################################################################################### 2026-02-02 14:57:35,676 INFO ### RUN 1/2: NORMAL OPERATION 2026-02-02 14:57:35,676 INFO #################################################################################################### 2026-02-02 14:57:35,676 INFO 2026-02-02 14:57:35,676 INFO SCENARIO: normal 2026-02-02 14:57:35,677 INFO DESCRIPTION: All systems operational - no failures 2026-02-02 14:57:35,677 INFO 2026-02-02 14:57:35,677 INFO EXPECTED FAILURES: 2026-02-02 14:57:35,677 INFO (none) 2026-02-02 14:57:35,677 INFO 2026-02-02 14:57:35,677 INFO EXPECTED PASSES: 2026-02-02 14:57:35,677 INFO ✓ All B6 status fields (except pedestal) 2026-02-02 14:57:35,677 INFO ✓ All B8 diagnostic fields 2026-02-02 14:57:35,678 INFO ✓ Target generation 2026-02-02 14:57:35,678 INFO 2026-02-02 14:57:35,678 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present) 2026-02-02 14:57:35,678 INFO 2026-02-02 14:57:35,678 INFO #################################################################################################### 2026-02-02 14:57:35,679 INFO #################################################################################################### 2026-02-02 14:57:35,679 INFO 2026-02-02 14:57:35,679 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 14:57:35,679 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected) 2026-02-02 14:57:35,679 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1) 2026-02-02 14:57:40,680 INFO Check that MAIN_POWER is equal to 1 2026-02-02 14:57:40,681 INFO OK: read value = True 2026-02-02 14:57:40,784 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 14:57:40,987 INFO [MOCK] BIT report available after 5.3s 2026-02-02 14:57:41,007 INFO BIT report available after 0.2s 2026-02-02 14:57:41,008 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false 2026-02-02 14:57:41,008 INFO OK: read value = false 2026-02-02 14:57:41,008 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false 2026-02-02 14:57:41,008 WARNING CHECK ERROR: read value = true 2026-02-02 14:57:41,008 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:57:41,008 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status 2026-02-02 14:57:41,008 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false 2026-02-02 14:57:41,009 INFO OK: read value = false 2026-02-02 14:57:41,009 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false 2026-02-02 14:57:41,009 INFO OK: read value = false 2026-02-02 14:57:41,010 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false 2026-02-02 14:57:41,010 INFO OK: read value = false 2026-02-02 14:57:41,010 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false 2026-02-02 14:57:41,011 INFO OK: read value = false 2026-02-02 14:57:41,011 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false 2026-02-02 14:57:41,011 INFO OK: read value = false 2026-02-02 14:57:41,011 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false 2026-02-02 14:57:41,011 INFO OK: read value = false 2026-02-02 14:57:41,011 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false 2026-02-02 14:57:41,011 INFO OK: read value = false 2026-02-02 14:57:41,011 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false 2026-02-02 14:57:41,011 INFO OK: read value = false 2026-02-02 14:57:41,012 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false 2026-02-02 14:57:41,012 INFO OK: read value = false 2026-02-02 14:57:41,012 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false 2026-02-02 14:57:41,012 WARNING CHECK ERROR: read value = RDR_OK 2026-02-02 14:57:41,012 ERROR INTERFACE ERROR: Expected false, got RDR_OK 2026-02-02 14:57:41,012 WARNING Radar fail status: Known failure (caused only by pedestal) 2026-02-02 14:57:41,013 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known 2026-02-02 14:57:41,014 INFO Known failures (HW setup): 2 2026-02-02 14:57:41,015 INFO Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields... 2026-02-02 14:57:41,015 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures 2026-02-02 14:57:41,015 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false 2026-02-02 14:57:41,015 INFO OK: read value = false 2026-02-02 14:57:41,015 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false 2026-02-02 14:57:41,016 INFO OK: read value = false 2026-02-02 14:57:41,017 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false 2026-02-02 14:57:41,017 INFO OK: read value = false 2026-02-02 14:57:41,017 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false 2026-02-02 14:57:41,018 INFO OK: read value = false 2026-02-02 14:57:41,018 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false 2026-02-02 14:57:41,018 INFO OK: read value = false 2026-02-02 14:57:41,018 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false 2026-02-02 14:57:41,018 INFO OK: read value = false 2026-02-02 14:57:41,019 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false 2026-02-02 14:57:41,019 INFO OK: read value = false 2026-02-02 14:57:41,019 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false 2026-02-02 14:57:41,019 INFO OK: read value = false 2026-02-02 14:57:41,019 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false 2026-02-02 14:57:41,020 INFO OK: read value = false 2026-02-02 14:57:41,020 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false 2026-02-02 14:57:41,020 WARNING CHECK ERROR: read value = 0 2026-02-02 14:57:41,020 ERROR INTERFACE ERROR: Expected false, got 0 2026-02-02 14:57:41,020 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false 2026-02-02 14:57:41,020 INFO OK: read value = false 2026-02-02 14:57:41,020 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false 2026-02-02 14:57:41,020 INFO OK: read value = false 2026-02-02 14:57:41,020 WARNING B8_Degradation: 1/12 failures 2026-02-02 14:57:41,021 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false 2026-02-02 14:57:41,021 INFO OK: read value = false 2026-02-02 14:57:41,021 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false 2026-02-02 14:57:41,021 INFO OK: read value = false 2026-02-02 14:57:41,021 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false 2026-02-02 14:57:41,021 INFO OK: read value = false 2026-02-02 14:57:41,021 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false 2026-02-02 14:57:41,021 INFO OK: read value = false 2026-02-02 14:57:41,021 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false 2026-02-02 14:57:41,021 INFO OK: read value = false 2026-02-02 14:57:41,022 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false 2026-02-02 14:57:41,022 INFO OK: read value = false 2026-02-02 14:57:41,022 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false 2026-02-02 14:57:41,022 INFO OK: read value = false 2026-02-02 14:57:41,022 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false 2026-02-02 14:57:41,022 INFO OK: read value = false 2026-02-02 14:57:41,022 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false 2026-02-02 14:57:41,022 INFO OK: read value = false 2026-02-02 14:57:41,023 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false 2026-02-02 14:57:41,023 INFO OK: read value = false 2026-02-02 14:57:41,023 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false 2026-02-02 14:57:41,023 INFO OK: read value = false 2026-02-02 14:57:41,023 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false 2026-02-02 14:57:41,023 INFO OK: read value = false 2026-02-02 14:57:41,023 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false 2026-02-02 14:57:41,023 INFO OK: read value = false 2026-02-02 14:57:41,023 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false 2026-02-02 14:57:41,023 INFO OK: read value = false 2026-02-02 14:57:41,024 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false 2026-02-02 14:57:41,024 INFO OK: read value = false 2026-02-02 14:57:41,024 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false 2026-02-02 14:57:41,024 INFO OK: read value = false 2026-02-02 14:57:41,024 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false 2026-02-02 14:57:41,026 INFO OK: read value = false 2026-02-02 14:57:41,026 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false 2026-02-02 14:57:41,026 INFO OK: read value = false 2026-02-02 14:57:41,026 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false 2026-02-02 14:57:41,026 INFO OK: read value = false 2026-02-02 14:57:41,026 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false 2026-02-02 14:57:41,026 INFO OK: read value = false 2026-02-02 14:57:41,027 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false 2026-02-02 14:57:41,027 INFO OK: read value = false 2026-02-02 14:57:41,027 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false 2026-02-02 14:57:41,027 INFO OK: read value = false 2026-02-02 14:57:41,027 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false 2026-02-02 14:57:41,028 INFO OK: read value = false 2026-02-02 14:57:41,028 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false 2026-02-02 14:57:41,028 INFO OK: read value = false 2026-02-02 14:57:41,029 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false 2026-02-02 14:57:41,029 INFO OK: read value = false 2026-02-02 14:57:41,029 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false 2026-02-02 14:57:41,029 INFO OK: read value = false 2026-02-02 14:57:41,029 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false 2026-02-02 14:57:41,029 INFO OK: read value = false 2026-02-02 14:57:41,029 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false 2026-02-02 14:57:41,029 INFO OK: read value = false 2026-02-02 14:57:41,029 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false 2026-02-02 14:57:41,029 INFO OK: read value = false 2026-02-02 14:57:41,029 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false 2026-02-02 14:57:41,029 INFO OK: read value = false 2026-02-02 14:57:41,029 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false 2026-02-02 14:57:41,030 INFO OK: read value = false 2026-02-02 14:57:41,030 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false 2026-02-02 14:57:41,030 INFO OK: read value = false 2026-02-02 14:57:41,030 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false 2026-02-02 14:57:41,030 INFO OK: read value = false 2026-02-02 14:57:41,030 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false 2026-02-02 14:57:41,030 INFO OK: read value = false 2026-02-02 14:57:41,030 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false 2026-02-02 14:57:41,030 INFO OK: read value = false 2026-02-02 14:57:41,030 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false 2026-02-02 14:57:41,030 INFO OK: read value = false 2026-02-02 14:57:41,030 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false 2026-02-02 14:57:41,031 INFO OK: read value = false 2026-02-02 14:57:41,031 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false 2026-02-02 14:57:41,031 INFO OK: read value = false 2026-02-02 14:57:41,031 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false 2026-02-02 14:57:41,031 INFO OK: read value = false 2026-02-02 14:57:41,031 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false 2026-02-02 14:57:41,031 INFO OK: read value = false 2026-02-02 14:57:41,031 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false 2026-02-02 14:57:41,031 INFO OK: read value = false 2026-02-02 14:57:41,032 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false 2026-02-02 14:57:41,032 INFO OK: read value = false 2026-02-02 14:57:41,032 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false 2026-02-02 14:57:41,032 INFO OK: read value = false 2026-02-02 14:57:41,032 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false 2026-02-02 14:57:41,032 INFO OK: read value = false 2026-02-02 14:57:41,032 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false 2026-02-02 14:57:41,032 INFO OK: read value = false 2026-02-02 14:57:41,032 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false 2026-02-02 14:57:41,033 INFO OK: read value = false 2026-02-02 14:57:41,033 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false 2026-02-02 14:57:41,033 INFO OK: read value = false 2026-02-02 14:57:41,033 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false 2026-02-02 14:57:41,034 INFO OK: read value = false 2026-02-02 14:57:41,034 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false 2026-02-02 14:57:41,034 INFO OK: read value = false 2026-02-02 14:57:41,034 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false 2026-02-02 14:57:41,034 INFO OK: read value = false 2026-02-02 14:57:41,034 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false 2026-02-02 14:57:41,035 INFO OK: read value = false 2026-02-02 14:57:41,035 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false 2026-02-02 14:57:41,035 INFO OK: read value = false 2026-02-02 14:57:41,035 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false 2026-02-02 14:57:41,035 INFO OK: read value = false 2026-02-02 14:57:41,036 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false 2026-02-02 14:57:41,036 INFO OK: read value = false 2026-02-02 14:57:41,036 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false 2026-02-02 14:57:41,036 INFO OK: read value = false 2026-02-02 14:57:41,036 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false 2026-02-02 14:57:41,036 INFO OK: read value = false 2026-02-02 14:57:41,036 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false 2026-02-02 14:57:41,037 INFO OK: read value = false 2026-02-02 14:57:41,037 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false 2026-02-02 14:57:41,037 INFO OK: read value = false 2026-02-02 14:57:41,037 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false 2026-02-02 14:57:41,037 INFO OK: read value = false 2026-02-02 14:57:41,037 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false 2026-02-02 14:57:41,037 INFO OK: read value = false 2026-02-02 14:57:41,037 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false 2026-02-02 14:57:41,038 INFO OK: read value = false 2026-02-02 14:57:41,038 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false 2026-02-02 14:57:41,038 INFO OK: read value = false 2026-02-02 14:57:41,038 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false 2026-02-02 14:57:41,038 INFO OK: read value = false 2026-02-02 14:57:41,038 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false 2026-02-02 14:57:41,038 INFO OK: read value = false 2026-02-02 14:57:41,039 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false 2026-02-02 14:57:41,039 INFO OK: read value = false 2026-02-02 14:57:41,039 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false 2026-02-02 14:57:41,039 INFO OK: read value = false 2026-02-02 14:57:41,039 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false 2026-02-02 14:57:41,039 INFO OK: read value = false 2026-02-02 14:57:41,039 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false 2026-02-02 14:57:41,039 INFO OK: read value = false 2026-02-02 14:57:41,040 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false 2026-02-02 14:57:41,040 INFO OK: read value = false 2026-02-02 14:57:41,040 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false 2026-02-02 14:57:41,040 INFO OK: read value = false 2026-02-02 14:57:41,040 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false 2026-02-02 14:57:41,040 INFO OK: read value = false 2026-02-02 14:57:41,040 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false 2026-02-02 14:57:41,040 INFO OK: read value = false 2026-02-02 14:57:41,040 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false 2026-02-02 14:57:41,040 INFO OK: read value = false 2026-02-02 14:57:41,040 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false 2026-02-02 14:57:41,041 INFO OK: read value = false 2026-02-02 14:57:41,041 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false 2026-02-02 14:57:41,041 INFO OK: read value = false 2026-02-02 14:57:41,041 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false 2026-02-02 14:57:41,041 INFO OK: read value = false 2026-02-02 14:57:41,041 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false 2026-02-02 14:57:41,041 INFO OK: read value = false 2026-02-02 14:57:41,041 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false 2026-02-02 14:57:41,042 INFO OK: read value = false 2026-02-02 14:57:41,042 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false 2026-02-02 14:57:41,042 INFO OK: read value = false 2026-02-02 14:57:41,042 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false 2026-02-02 14:57:41,042 INFO OK: read value = false 2026-02-02 14:57:41,042 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false 2026-02-02 14:57:41,042 INFO OK: read value = false 2026-02-02 14:57:41,042 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false 2026-02-02 14:57:41,042 INFO OK: read value = false 2026-02-02 14:57:41,043 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false 2026-02-02 14:57:41,043 INFO OK: read value = false 2026-02-02 14:57:41,043 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false 2026-02-02 14:57:41,043 INFO OK: read value = false 2026-02-02 14:57:41,043 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false 2026-02-02 14:57:41,043 INFO OK: read value = false 2026-02-02 14:57:41,043 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false 2026-02-02 14:57:41,044 INFO OK: read value = false 2026-02-02 14:57:41,044 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false 2026-02-02 14:57:41,044 INFO OK: read value = false 2026-02-02 14:57:41,045 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false 2026-02-02 14:57:41,045 INFO OK: read value = false 2026-02-02 14:57:41,045 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false 2026-02-02 14:57:41,046 INFO OK: read value = false 2026-02-02 14:57:41,046 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false 2026-02-02 14:57:41,046 INFO OK: read value = false 2026-02-02 14:57:41,047 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false 2026-02-02 14:57:41,047 INFO OK: read value = false 2026-02-02 14:57:41,048 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false 2026-02-02 14:57:41,048 INFO OK: read value = false 2026-02-02 14:57:41,048 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false 2026-02-02 14:57:41,049 INFO OK: read value = false 2026-02-02 14:57:41,049 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false 2026-02-02 14:57:41,049 INFO OK: read value = false 2026-02-02 14:57:41,050 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false 2026-02-02 14:57:41,050 INFO OK: read value = false 2026-02-02 14:57:41,050 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false 2026-02-02 14:57:41,050 INFO OK: read value = false 2026-02-02 14:57:41,051 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false 2026-02-02 14:57:41,051 INFO OK: read value = false 2026-02-02 14:57:41,051 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false 2026-02-02 14:57:41,051 INFO OK: read value = false 2026-02-02 14:57:41,051 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false 2026-02-02 14:57:41,052 INFO OK: read value = false 2026-02-02 14:57:41,052 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false 2026-02-02 14:57:41,052 INFO OK: read value = false 2026-02-02 14:57:41,052 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false 2026-02-02 14:57:41,052 INFO OK: read value = false 2026-02-02 14:57:41,052 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false 2026-02-02 14:57:41,052 INFO OK: read value = false 2026-02-02 14:57:41,053 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false 2026-02-02 14:57:41,053 INFO OK: read value = false 2026-02-02 14:57:41,053 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false 2026-02-02 14:57:41,053 INFO OK: read value = false 2026-02-02 14:57:41,053 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false 2026-02-02 14:57:41,053 INFO OK: read value = false 2026-02-02 14:57:41,053 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false 2026-02-02 14:57:41,053 INFO OK: read value = false 2026-02-02 14:57:41,054 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false 2026-02-02 14:57:41,054 INFO OK: read value = false 2026-02-02 14:57:41,054 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false 2026-02-02 14:57:41,054 INFO OK: read value = false 2026-02-02 14:57:41,054 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false 2026-02-02 14:57:41,055 INFO OK: read value = false 2026-02-02 14:57:41,055 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false 2026-02-02 14:57:41,055 INFO OK: read value = false 2026-02-02 14:57:41,055 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false 2026-02-02 14:57:41,055 INFO OK: read value = false 2026-02-02 14:57:41,055 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false 2026-02-02 14:57:41,056 INFO OK: read value = false 2026-02-02 14:57:41,056 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false 2026-02-02 14:57:41,056 INFO OK: read value = false 2026-02-02 14:57:41,056 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false 2026-02-02 14:57:41,056 INFO OK: read value = false 2026-02-02 14:57:41,056 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false 2026-02-02 14:57:41,056 INFO OK: read value = false 2026-02-02 14:57:41,057 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false 2026-02-02 14:57:41,057 INFO OK: read value = false 2026-02-02 14:57:41,057 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false 2026-02-02 14:57:41,057 INFO OK: read value = false 2026-02-02 14:57:41,057 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false 2026-02-02 14:57:41,057 INFO OK: read value = false 2026-02-02 14:57:41,057 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false 2026-02-02 14:57:41,057 INFO OK: read value = false 2026-02-02 14:57:41,057 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false 2026-02-02 14:57:41,058 INFO OK: read value = false 2026-02-02 14:57:41,058 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false 2026-02-02 14:57:41,058 INFO OK: read value = false 2026-02-02 14:57:41,058 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false 2026-02-02 14:57:41,058 INFO OK: read value = false 2026-02-02 14:57:41,058 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false 2026-02-02 14:57:41,058 INFO OK: read value = false 2026-02-02 14:57:41,058 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false 2026-02-02 14:57:41,058 INFO OK: read value = false 2026-02-02 14:57:41,059 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false 2026-02-02 14:57:41,059 INFO OK: read value = false 2026-02-02 14:57:41,059 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false 2026-02-02 14:57:41,059 INFO OK: read value = false 2026-02-02 14:57:41,059 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false 2026-02-02 14:57:41,059 INFO OK: read value = false 2026-02-02 14:57:41,059 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false 2026-02-02 14:57:41,059 INFO OK: read value = false 2026-02-02 14:57:41,060 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false 2026-02-02 14:57:41,060 INFO OK: read value = false 2026-02-02 14:57:41,060 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false 2026-02-02 14:57:41,060 INFO OK: read value = false 2026-02-02 14:57:41,060 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false 2026-02-02 14:57:41,060 INFO OK: read value = false 2026-02-02 14:57:41,060 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false 2026-02-02 14:57:41,060 INFO OK: read value = false 2026-02-02 14:57:41,061 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false 2026-02-02 14:57:41,061 INFO OK: read value = false 2026-02-02 14:57:41,061 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false 2026-02-02 14:57:41,061 INFO OK: read value = false 2026-02-02 14:57:41,061 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false 2026-02-02 14:57:41,061 INFO OK: read value = false 2026-02-02 14:57:41,062 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false 2026-02-02 14:57:41,062 INFO OK: read value = false 2026-02-02 14:57:41,062 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false 2026-02-02 14:57:41,062 INFO OK: read value = false 2026-02-02 14:57:41,062 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false 2026-02-02 14:57:41,062 INFO OK: read value = false 2026-02-02 14:57:41,063 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false 2026-02-02 14:57:41,063 INFO OK: read value = false 2026-02-02 14:57:41,063 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false 2026-02-02 14:57:41,063 INFO OK: read value = false 2026-02-02 14:57:41,063 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false 2026-02-02 14:57:41,063 INFO OK: read value = false 2026-02-02 14:57:41,063 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false 2026-02-02 14:57:41,064 INFO OK: read value = false 2026-02-02 14:57:41,064 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false 2026-02-02 14:57:41,064 INFO OK: read value = false 2026-02-02 14:57:41,065 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false 2026-02-02 14:57:41,065 INFO OK: read value = false 2026-02-02 14:57:41,065 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false 2026-02-02 14:57:41,065 INFO OK: read value = false 2026-02-02 14:57:41,065 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false 2026-02-02 14:57:41,065 INFO OK: read value = false 2026-02-02 14:57:41,065 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false 2026-02-02 14:57:41,066 INFO OK: read value = false 2026-02-02 14:57:41,066 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false 2026-02-02 14:57:41,066 INFO OK: read value = false 2026-02-02 14:57:41,066 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false 2026-02-02 14:57:41,066 INFO OK: read value = false 2026-02-02 14:57:41,066 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false 2026-02-02 14:57:41,066 INFO OK: read value = false 2026-02-02 14:57:41,066 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false 2026-02-02 14:57:41,067 INFO OK: read value = false 2026-02-02 14:57:41,067 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false 2026-02-02 14:57:41,067 INFO OK: read value = false 2026-02-02 14:57:41,067 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false 2026-02-02 14:57:41,067 INFO OK: read value = false 2026-02-02 14:57:41,067 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false 2026-02-02 14:57:41,068 INFO OK: read value = false 2026-02-02 14:57:41,068 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false 2026-02-02 14:57:41,068 INFO OK: read value = false 2026-02-02 14:57:41,068 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false 2026-02-02 14:57:41,068 INFO OK: read value = false 2026-02-02 14:57:41,068 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false 2026-02-02 14:57:41,068 INFO OK: read value = false 2026-02-02 14:57:41,068 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false 2026-02-02 14:57:41,068 INFO OK: read value = false 2026-02-02 14:57:41,069 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false 2026-02-02 14:57:41,069 INFO OK: read value = false 2026-02-02 14:57:41,069 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false 2026-02-02 14:57:41,069 INFO OK: read value = false 2026-02-02 14:57:41,069 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false 2026-02-02 14:57:41,069 INFO OK: read value = false 2026-02-02 14:57:41,069 INFO [Run 1] B8 Diagnostics: 173 checked, 172 pass, 1 fail 2026-02-02 14:57:41,069 WARNING B8_Degradation: 1 failures - fail 2026-02-02 14:57:41,069 INFO 0.0s remaining ... 2026-02-02 14:57:41,070 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles 2026-02-02 14:57:41,070 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 2 Total Step 192: Success 189 (98.44%), Failed 3 (1.56%), 2026-02-02 14:57:41,070 INFO Repetition 2 of 2 2026-02-02 14:57:41,070 DEBUG [MOCK] Serial statistics reset 2026-02-02 14:57:41,070 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 14:57:42,071 INFO Set MAIN_POWER to False 2026-02-02 14:57:42,071 INFO [MOCK] Power OFF 2026-02-02 14:57:42,072 INFO [MOCK] 1553 Interface stopped 2026-02-02 14:57:47,073 INFO Check that MAIN_POWER is equal to 0 2026-02-02 14:57:47,073 INFO OK: read value = False 2026-02-02 14:57:51,074 INFO The test operator is required to switch on the target. 2026-02-02 14:57:51,075 INFO Set MAIN_POWER to True 2026-02-02 14:57:51,075 INFO [MOCK] Power ON 2026-02-02 14:57:51,076 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 14:57:51,076 INFO run_count = 2 2026-02-02 14:57:51,076 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 14:57:51,077 INFO current_scenario = 'mixed' 2026-02-02 14:57:51,077 INFO _scenario_list = ['normal', 'normal'] 2026-02-02 14:57:51,077 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 14:57:51,077 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='normal' 2026-02-02 14:57:51,078 INFO [DEBUG] About to call _log_scenario_info('normal', 2, 2) 2026-02-02 14:57:51,078 INFO 2026-02-02 14:57:51,078 INFO #################################################################################################### 2026-02-02 14:57:51,078 INFO #################################################################################################### 2026-02-02 14:57:51,078 INFO ### RUN 2/2: NORMAL OPERATION 2026-02-02 14:57:51,078 INFO #################################################################################################### 2026-02-02 14:57:51,080 INFO 2026-02-02 14:57:51,080 INFO SCENARIO: normal 2026-02-02 14:57:51,081 INFO DESCRIPTION: All systems operational - no failures 2026-02-02 14:57:51,081 INFO 2026-02-02 14:57:51,081 INFO EXPECTED FAILURES: 2026-02-02 14:57:51,081 INFO (none) 2026-02-02 14:57:51,082 INFO 2026-02-02 14:57:51,082 INFO EXPECTED PASSES: 2026-02-02 14:57:51,082 INFO ✓ All B6 status fields (except pedestal) 2026-02-02 14:57:51,082 INFO ✓ All B8 diagnostic fields 2026-02-02 14:57:51,082 INFO ✓ Target generation 2026-02-02 14:57:51,082 INFO 2026-02-02 14:57:51,083 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present) 2026-02-02 14:57:51,083 INFO 2026-02-02 14:57:51,083 INFO #################################################################################################### 2026-02-02 14:57:51,083 INFO #################################################################################################### 2026-02-02 14:57:51,083 INFO 2026-02-02 14:57:51,083 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 14:57:51,083 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected) 2026-02-02 14:57:51,083 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2) 2026-02-02 14:57:56,084 INFO Check that MAIN_POWER is equal to 1 2026-02-02 14:57:56,085 INFO OK: read value = True 2026-02-02 14:57:56,186 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 14:57:56,387 INFO [MOCK] BIT report available after 5.3s 2026-02-02 14:57:56,408 INFO BIT report available after 0.2s 2026-02-02 14:57:56,409 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false 2026-02-02 14:57:56,409 INFO OK: read value = false 2026-02-02 14:57:56,409 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false 2026-02-02 14:57:56,409 WARNING CHECK ERROR: read value = true 2026-02-02 14:57:56,410 ERROR INTERFACE ERROR: Expected false, got true 2026-02-02 14:57:56,410 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status 2026-02-02 14:57:56,410 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false 2026-02-02 14:57:56,412 INFO OK: read value = false 2026-02-02 14:57:56,412 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false 2026-02-02 14:57:56,412 INFO OK: read value = false 2026-02-02 14:57:56,412 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false 2026-02-02 14:57:56,412 INFO OK: read value = false 2026-02-02 14:57:56,413 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false 2026-02-02 14:57:56,413 INFO OK: read value = false 2026-02-02 14:57:56,413 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false 2026-02-02 14:57:56,413 INFO OK: read value = false 2026-02-02 14:57:56,413 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false 2026-02-02 14:57:56,414 INFO OK: read value = false 2026-02-02 14:57:56,414 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false 2026-02-02 14:57:56,414 INFO OK: read value = false 2026-02-02 14:57:56,414 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false 2026-02-02 14:57:56,414 INFO OK: read value = false 2026-02-02 14:57:56,414 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false 2026-02-02 14:57:56,415 INFO OK: read value = false 2026-02-02 14:57:56,415 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false 2026-02-02 14:57:56,415 WARNING CHECK ERROR: read value = RDR_OK 2026-02-02 14:57:56,415 ERROR INTERFACE ERROR: Expected false, got RDR_OK 2026-02-02 14:57:56,415 WARNING Radar fail status: Known failure (caused only by pedestal) 2026-02-02 14:57:56,415 INFO [Run 2] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known 2026-02-02 14:57:56,416 INFO Known failures (HW setup): 2 2026-02-02 14:57:56,416 INFO Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields... 2026-02-02 14:57:56,416 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures 2026-02-02 14:57:56,416 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false 2026-02-02 14:57:56,416 INFO OK: read value = false 2026-02-02 14:57:56,416 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false 2026-02-02 14:57:56,416 INFO OK: read value = false 2026-02-02 14:57:56,417 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false 2026-02-02 14:57:56,417 INFO OK: read value = false 2026-02-02 14:57:56,417 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false 2026-02-02 14:57:56,417 INFO OK: read value = false 2026-02-02 14:57:56,417 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false 2026-02-02 14:57:56,417 INFO OK: read value = false 2026-02-02 14:57:56,417 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false 2026-02-02 14:57:56,417 INFO OK: read value = false 2026-02-02 14:57:56,418 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false 2026-02-02 14:57:56,418 INFO OK: read value = false 2026-02-02 14:57:56,418 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false 2026-02-02 14:57:56,418 INFO OK: read value = false 2026-02-02 14:57:56,418 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false 2026-02-02 14:57:56,418 INFO OK: read value = false 2026-02-02 14:57:56,418 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false 2026-02-02 14:57:56,418 WARNING CHECK ERROR: read value = 0 2026-02-02 14:57:56,419 ERROR INTERFACE ERROR: Expected false, got 0 2026-02-02 14:57:56,419 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false 2026-02-02 14:57:56,419 INFO OK: read value = false 2026-02-02 14:57:56,419 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false 2026-02-02 14:57:56,419 INFO OK: read value = false 2026-02-02 14:57:56,419 WARNING B8_Degradation: 1/12 failures 2026-02-02 14:57:56,420 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false 2026-02-02 14:57:56,420 INFO OK: read value = false 2026-02-02 14:57:56,420 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false 2026-02-02 14:57:56,420 INFO OK: read value = false 2026-02-02 14:57:56,420 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false 2026-02-02 14:57:56,420 INFO OK: read value = false 2026-02-02 14:57:56,420 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false 2026-02-02 14:57:56,420 INFO OK: read value = false 2026-02-02 14:57:56,420 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false 2026-02-02 14:57:56,420 INFO OK: read value = false 2026-02-02 14:57:56,421 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false 2026-02-02 14:57:56,421 INFO OK: read value = false 2026-02-02 14:57:56,421 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false 2026-02-02 14:57:56,421 INFO OK: read value = false 2026-02-02 14:57:56,421 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false 2026-02-02 14:57:56,421 INFO OK: read value = false 2026-02-02 14:57:56,421 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false 2026-02-02 14:57:56,421 INFO OK: read value = false 2026-02-02 14:57:56,422 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false 2026-02-02 14:57:56,423 INFO OK: read value = false 2026-02-02 14:57:56,423 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false 2026-02-02 14:57:56,423 INFO OK: read value = false 2026-02-02 14:57:56,424 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false 2026-02-02 14:57:56,424 INFO OK: read value = false 2026-02-02 14:57:56,424 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false 2026-02-02 14:57:56,424 INFO OK: read value = false 2026-02-02 14:57:56,424 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false 2026-02-02 14:57:56,424 INFO OK: read value = false 2026-02-02 14:57:56,424 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false 2026-02-02 14:57:56,425 INFO OK: read value = false 2026-02-02 14:57:56,425 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false 2026-02-02 14:57:56,425 INFO OK: read value = false 2026-02-02 14:57:56,425 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false 2026-02-02 14:57:56,425 INFO OK: read value = false 2026-02-02 14:57:56,425 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false 2026-02-02 14:57:56,425 INFO OK: read value = false 2026-02-02 14:57:56,425 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false 2026-02-02 14:57:56,425 INFO OK: read value = false 2026-02-02 14:57:56,426 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false 2026-02-02 14:57:56,426 INFO OK: read value = false 2026-02-02 14:57:56,426 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false 2026-02-02 14:57:56,426 INFO OK: read value = false 2026-02-02 14:57:56,426 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false 2026-02-02 14:57:56,426 INFO OK: read value = false 2026-02-02 14:57:56,426 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false 2026-02-02 14:57:56,427 INFO OK: read value = false 2026-02-02 14:57:56,427 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false 2026-02-02 14:57:56,427 INFO OK: read value = false 2026-02-02 14:57:56,427 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false 2026-02-02 14:57:56,427 INFO OK: read value = false 2026-02-02 14:57:56,427 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false 2026-02-02 14:57:56,427 INFO OK: read value = false 2026-02-02 14:57:56,427 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false 2026-02-02 14:57:56,427 INFO OK: read value = false 2026-02-02 14:57:56,427 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false 2026-02-02 14:57:56,427 INFO OK: read value = false 2026-02-02 14:57:56,428 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false 2026-02-02 14:57:56,428 INFO OK: read value = false 2026-02-02 14:57:56,428 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false 2026-02-02 14:57:56,428 INFO OK: read value = false 2026-02-02 14:57:56,428 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false 2026-02-02 14:57:56,428 INFO OK: read value = false 2026-02-02 14:57:56,428 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false 2026-02-02 14:57:56,428 INFO OK: read value = false 2026-02-02 14:57:56,428 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false 2026-02-02 14:57:56,428 INFO OK: read value = false 2026-02-02 14:57:56,428 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false 2026-02-02 14:57:56,429 INFO OK: read value = false 2026-02-02 14:57:56,429 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false 2026-02-02 14:57:56,429 INFO OK: read value = false 2026-02-02 14:57:56,429 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false 2026-02-02 14:57:56,429 INFO OK: read value = false 2026-02-02 14:57:56,429 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false 2026-02-02 14:57:56,429 INFO OK: read value = false 2026-02-02 14:57:56,429 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false 2026-02-02 14:57:56,429 INFO OK: read value = false 2026-02-02 14:57:56,429 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false 2026-02-02 14:57:56,430 INFO OK: read value = false 2026-02-02 14:57:56,430 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false 2026-02-02 14:57:56,430 INFO OK: read value = false 2026-02-02 14:57:56,430 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false 2026-02-02 14:57:56,430 INFO OK: read value = false 2026-02-02 14:57:56,430 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false 2026-02-02 14:57:56,430 INFO OK: read value = false 2026-02-02 14:57:56,430 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false 2026-02-02 14:57:56,430 INFO OK: read value = false 2026-02-02 14:57:56,430 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false 2026-02-02 14:57:56,430 INFO OK: read value = false 2026-02-02 14:57:56,430 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false 2026-02-02 14:57:56,430 INFO OK: read value = false 2026-02-02 14:57:56,431 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false 2026-02-02 14:57:56,431 INFO OK: read value = false 2026-02-02 14:57:56,431 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false 2026-02-02 14:57:56,431 INFO OK: read value = false 2026-02-02 14:57:56,431 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false 2026-02-02 14:57:56,431 INFO OK: read value = false 2026-02-02 14:57:56,431 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false 2026-02-02 14:57:56,431 INFO OK: read value = false 2026-02-02 14:57:56,431 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false 2026-02-02 14:57:56,431 INFO OK: read value = false 2026-02-02 14:57:56,431 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false 2026-02-02 14:57:56,432 INFO OK: read value = false 2026-02-02 14:57:56,432 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false 2026-02-02 14:57:56,432 INFO OK: read value = false 2026-02-02 14:57:56,432 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false 2026-02-02 14:57:56,432 INFO OK: read value = false 2026-02-02 14:57:56,432 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false 2026-02-02 14:57:56,433 INFO OK: read value = false 2026-02-02 14:57:56,433 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false 2026-02-02 14:57:56,433 INFO OK: read value = false 2026-02-02 14:57:56,433 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false 2026-02-02 14:57:56,433 INFO OK: read value = false 2026-02-02 14:57:56,433 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false 2026-02-02 14:57:56,433 INFO OK: read value = false 2026-02-02 14:57:56,433 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false 2026-02-02 14:57:56,433 INFO OK: read value = false 2026-02-02 14:57:56,434 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false 2026-02-02 14:57:56,434 INFO OK: read value = false 2026-02-02 14:57:56,434 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false 2026-02-02 14:57:56,434 INFO OK: read value = false 2026-02-02 14:57:56,434 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false 2026-02-02 14:57:56,434 INFO OK: read value = false 2026-02-02 14:57:56,434 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false 2026-02-02 14:57:56,435 INFO OK: read value = false 2026-02-02 14:57:56,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false 2026-02-02 14:57:56,435 INFO OK: read value = false 2026-02-02 14:57:56,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false 2026-02-02 14:57:56,435 INFO OK: read value = false 2026-02-02 14:57:56,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false 2026-02-02 14:57:56,435 INFO OK: read value = false 2026-02-02 14:57:56,435 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false 2026-02-02 14:57:56,436 INFO OK: read value = false 2026-02-02 14:57:56,436 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false 2026-02-02 14:57:56,436 INFO OK: read value = false 2026-02-02 14:57:56,436 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false 2026-02-02 14:57:56,436 INFO OK: read value = false 2026-02-02 14:57:56,436 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false 2026-02-02 14:57:56,436 INFO OK: read value = false 2026-02-02 14:57:56,436 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false 2026-02-02 14:57:56,436 INFO OK: read value = false 2026-02-02 14:57:56,436 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false 2026-02-02 14:57:56,436 INFO OK: read value = false 2026-02-02 14:57:56,436 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false 2026-02-02 14:57:56,437 INFO OK: read value = false 2026-02-02 14:57:56,437 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false 2026-02-02 14:57:56,437 INFO OK: read value = false 2026-02-02 14:57:56,437 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false 2026-02-02 14:57:56,437 INFO OK: read value = false 2026-02-02 14:57:56,437 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false 2026-02-02 14:57:56,437 INFO OK: read value = false 2026-02-02 14:57:56,437 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false 2026-02-02 14:57:56,437 INFO OK: read value = false 2026-02-02 14:57:56,437 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false 2026-02-02 14:57:56,437 INFO OK: read value = false 2026-02-02 14:57:56,437 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false 2026-02-02 14:57:56,438 INFO OK: read value = false 2026-02-02 14:57:56,438 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false 2026-02-02 14:57:56,438 INFO OK: read value = false 2026-02-02 14:57:56,438 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false 2026-02-02 14:57:56,438 INFO OK: read value = false 2026-02-02 14:57:56,438 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false 2026-02-02 14:57:56,438 INFO OK: read value = false 2026-02-02 14:57:56,438 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false 2026-02-02 14:57:56,438 INFO OK: read value = false 2026-02-02 14:57:56,438 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false 2026-02-02 14:57:56,438 INFO OK: read value = false 2026-02-02 14:57:56,438 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false 2026-02-02 14:57:56,439 INFO OK: read value = false 2026-02-02 14:57:56,439 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false 2026-02-02 14:57:56,439 INFO OK: read value = false 2026-02-02 14:57:56,439 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false 2026-02-02 14:57:56,439 INFO OK: read value = false 2026-02-02 14:57:56,439 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false 2026-02-02 14:57:56,439 INFO OK: read value = false 2026-02-02 14:57:56,439 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false 2026-02-02 14:57:56,439 INFO OK: read value = false 2026-02-02 14:57:56,439 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false 2026-02-02 14:57:56,439 INFO OK: read value = false 2026-02-02 14:57:56,439 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false 2026-02-02 14:57:56,439 INFO OK: read value = false 2026-02-02 14:57:56,439 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false 2026-02-02 14:57:56,440 INFO OK: read value = false 2026-02-02 14:57:56,440 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false 2026-02-02 14:57:56,440 INFO OK: read value = false 2026-02-02 14:57:56,440 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false 2026-02-02 14:57:56,440 INFO OK: read value = false 2026-02-02 14:57:56,440 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false 2026-02-02 14:57:56,440 INFO OK: read value = false 2026-02-02 14:57:56,440 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false 2026-02-02 14:57:56,440 INFO OK: read value = false 2026-02-02 14:57:56,440 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false 2026-02-02 14:57:56,441 INFO OK: read value = false 2026-02-02 14:57:56,441 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false 2026-02-02 14:57:56,441 INFO OK: read value = false 2026-02-02 14:57:56,441 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false 2026-02-02 14:57:56,441 INFO OK: read value = false 2026-02-02 14:57:56,441 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false 2026-02-02 14:57:56,441 INFO OK: read value = false 2026-02-02 14:57:56,441 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false 2026-02-02 14:57:56,441 INFO OK: read value = false 2026-02-02 14:57:56,441 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false 2026-02-02 14:57:56,441 INFO OK: read value = false 2026-02-02 14:57:56,442 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false 2026-02-02 14:57:56,442 INFO OK: read value = false 2026-02-02 14:57:56,442 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false 2026-02-02 14:57:56,442 INFO OK: read value = false 2026-02-02 14:57:56,442 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false 2026-02-02 14:57:56,442 INFO OK: read value = false 2026-02-02 14:57:56,442 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false 2026-02-02 14:57:56,442 INFO OK: read value = false 2026-02-02 14:57:56,443 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false 2026-02-02 14:57:56,443 INFO OK: read value = false 2026-02-02 14:57:56,443 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false 2026-02-02 14:57:56,443 INFO OK: read value = false 2026-02-02 14:57:56,443 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false 2026-02-02 14:57:56,443 INFO OK: read value = false 2026-02-02 14:57:56,443 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false 2026-02-02 14:57:56,443 INFO OK: read value = false 2026-02-02 14:57:56,443 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false 2026-02-02 14:57:56,443 INFO OK: read value = false 2026-02-02 14:57:56,443 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false 2026-02-02 14:57:56,444 INFO OK: read value = false 2026-02-02 14:57:56,444 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false 2026-02-02 14:57:56,444 INFO OK: read value = false 2026-02-02 14:57:56,444 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false 2026-02-02 14:57:56,444 INFO OK: read value = false 2026-02-02 14:57:56,444 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false 2026-02-02 14:57:56,444 INFO OK: read value = false 2026-02-02 14:57:56,444 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false 2026-02-02 14:57:56,445 INFO OK: read value = false 2026-02-02 14:57:56,445 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false 2026-02-02 14:57:56,445 INFO OK: read value = false 2026-02-02 14:57:56,445 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false 2026-02-02 14:57:56,445 INFO OK: read value = false 2026-02-02 14:57:56,445 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false 2026-02-02 14:57:56,445 INFO OK: read value = false 2026-02-02 14:57:56,445 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false 2026-02-02 14:57:56,446 INFO OK: read value = false 2026-02-02 14:57:56,446 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false 2026-02-02 14:57:56,446 INFO OK: read value = false 2026-02-02 14:57:56,446 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false 2026-02-02 14:57:56,446 INFO OK: read value = false 2026-02-02 14:57:56,446 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false 2026-02-02 14:57:56,446 INFO OK: read value = false 2026-02-02 14:57:56,447 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false 2026-02-02 14:57:56,447 INFO OK: read value = false 2026-02-02 14:57:56,447 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false 2026-02-02 14:57:56,447 INFO OK: read value = false 2026-02-02 14:57:56,447 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false 2026-02-02 14:57:56,447 INFO OK: read value = false 2026-02-02 14:57:56,447 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false 2026-02-02 14:57:56,447 INFO OK: read value = false 2026-02-02 14:57:56,447 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false 2026-02-02 14:57:56,448 INFO OK: read value = false 2026-02-02 14:57:56,448 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false 2026-02-02 14:57:56,448 INFO OK: read value = false 2026-02-02 14:57:56,448 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false 2026-02-02 14:57:56,448 INFO OK: read value = false 2026-02-02 14:57:56,448 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false 2026-02-02 14:57:56,448 INFO OK: read value = false 2026-02-02 14:57:56,450 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false 2026-02-02 14:57:56,450 INFO OK: read value = false 2026-02-02 14:57:56,450 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false 2026-02-02 14:57:56,452 INFO OK: read value = false 2026-02-02 14:57:56,453 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false 2026-02-02 14:57:56,453 INFO OK: read value = false 2026-02-02 14:57:56,453 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false 2026-02-02 14:57:56,453 INFO OK: read value = false 2026-02-02 14:57:56,454 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false 2026-02-02 14:57:56,454 INFO OK: read value = false 2026-02-02 14:57:56,454 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false 2026-02-02 14:57:56,454 INFO OK: read value = false 2026-02-02 14:57:56,454 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false 2026-02-02 14:57:56,455 INFO OK: read value = false 2026-02-02 14:57:56,455 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false 2026-02-02 14:57:56,455 INFO OK: read value = false 2026-02-02 14:57:56,455 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false 2026-02-02 14:57:56,455 INFO OK: read value = false 2026-02-02 14:57:56,455 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false 2026-02-02 14:57:56,455 INFO OK: read value = false 2026-02-02 14:57:56,455 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false 2026-02-02 14:57:56,456 INFO OK: read value = false 2026-02-02 14:57:56,456 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false 2026-02-02 14:57:56,456 INFO OK: read value = false 2026-02-02 14:57:56,456 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false 2026-02-02 14:57:56,456 INFO OK: read value = false 2026-02-02 14:57:56,456 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false 2026-02-02 14:57:56,456 INFO OK: read value = false 2026-02-02 14:57:56,456 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false 2026-02-02 14:57:56,456 INFO OK: read value = false 2026-02-02 14:57:56,456 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false 2026-02-02 14:57:56,456 INFO OK: read value = false 2026-02-02 14:57:56,457 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false 2026-02-02 14:57:56,457 INFO OK: read value = false 2026-02-02 14:57:56,457 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false 2026-02-02 14:57:56,457 INFO OK: read value = false 2026-02-02 14:57:56,457 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false 2026-02-02 14:57:56,457 INFO OK: read value = false 2026-02-02 14:57:56,457 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false 2026-02-02 14:57:56,457 INFO OK: read value = false 2026-02-02 14:57:56,458 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false 2026-02-02 14:57:56,458 INFO OK: read value = false 2026-02-02 14:57:56,458 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false 2026-02-02 14:57:56,458 INFO OK: read value = false 2026-02-02 14:57:56,458 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false 2026-02-02 14:57:56,458 INFO OK: read value = false 2026-02-02 14:57:56,458 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false 2026-02-02 14:57:56,458 INFO OK: read value = false 2026-02-02 14:57:56,459 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false 2026-02-02 14:57:56,459 INFO OK: read value = false 2026-02-02 14:57:56,459 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false 2026-02-02 14:57:56,459 INFO OK: read value = false 2026-02-02 14:57:56,459 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false 2026-02-02 14:57:56,459 INFO OK: read value = false 2026-02-02 14:57:56,459 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false 2026-02-02 14:57:56,459 INFO OK: read value = false 2026-02-02 14:57:56,460 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false 2026-02-02 14:57:56,460 INFO OK: read value = false 2026-02-02 14:57:56,460 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false 2026-02-02 14:57:56,461 INFO OK: read value = false 2026-02-02 14:57:56,461 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false 2026-02-02 14:57:56,461 INFO OK: read value = false 2026-02-02 14:57:56,462 INFO [Run 2] B8 Diagnostics: 173 checked, 172 pass, 1 fail 2026-02-02 14:57:56,462 WARNING B8_Degradation: 1 failures - fail 2026-02-02 14:57:56,462 INFO 0.0s remaining ... 2026-02-02 14:57:56,463 INFO [Run 2] Serial: 0 total, 0 errors, 0 fatal, 0 recycles 2026-02-02 14:57:56,463 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 2 Total Step 190: Success 187 (98.42%), Failed 3 (1.58%), 2026-02-02 14:57:56,463 INFO tgt_gen() 2026-02-02 14:57:56,474 DEBUG [MOCK] Field num: 1 2026-02-02 14:57:56,475 INFO TgtMsg: 1 1 2026-02-02 14:57:56,475 INFO Tgt: 1 @ 1180 2026-02-02 14:57:56,475 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 14:57:56,476 INFO OK: read value = 1 2026-02-02 14:57:56,476 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 14:57:56,476 INFO OK: read value = 1180 2026-02-02 14:57:56,477 INFO Repetitions terminated. 2026-02-02 14:57:56,477 INFO [Report] Custom statistics data registered for PDF generation 2026-02-02 14:57:56,478 INFO ========================================================================================== 2026-02-02 14:57:56,478 INFO FINAL TEST STATISTICS SUMMARY 2026-02-02 14:57:56,478 INFO ========================================================================================== 2026-02-02 14:57:56,479 INFO Total Runs: 2 2026-02-02 14:57:56,479 INFO Successful: 2 (100.0%) 2026-02-02 14:57:56,479 INFO Failed: 0 (0.0%) 2026-02-02 14:57:56,479 INFO B6 Checks: 24 (Pass: 20, Fail: 0, Known: 4) 2026-02-02 14:57:56,480 INFO B8 Checks: 346 (Pass: 344, Fail: 2) 2026-02-02 14:57:56,480 INFO Serial: 0 messages (0 errors, 0 fatal, 0 recycles) 2026-02-02 14:57:56,480 INFO PBIT Timing: avg=0.22s, min=0.22s, max=0.22s, σ=0.00s 2026-02-02 14:57:56,481 INFO ========================================================================================== 2026-02-02 14:57:56,481 INFO Detailed statistics will be available in the PDF report 2026-02-02 14:57:56,482 INFO Exporting statistics to CSV: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_145756_statistics.csv 2026-02-02 14:57:56,503 INFO Statistics exported successfully to: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_145756_statistics.csv 2026-02-02 14:57:56,504 INFO Statistics exported successfully to JSON: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_145756_statistics.json 2026-02-02 14:57:56,505 INFO Set MAIN_POWER to False 2026-02-02 14:57:56,506 INFO [MOCK] Power OFF 2026-02-02 14:57:56,506 INFO [MOCK] 1553 Interface stopped 2026-02-02 14:58:01,507 INFO Check that MAIN_POWER is equal to 0 2026-02-02 14:58:01,508 INFO OK: read value = False 2026-02-02 14:58:01,508 INFO [MOCK] Serial terminal disconnected 2026-02-02 14:58:01,508 INFO Stop Time: 2026-02-02 14:57:25.539620 2026-02-02 14:58:01,508 INFO Test execution time: 0:00:35.969097