2026-02-02 10:46:40,090 INFO Start Time: 2026-02-02 10:46:40.090391 2026-02-02 10:46:40,090 INFO [MOCK] Serial terminal initialized 2026-02-02 10:46:40,090 INFO [MOCK] Serial terminal connected 2026-02-02 10:46:40,101 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!****** 2026-02-02 10:46:40,101 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ... 2026-02-02 10:46:40,101 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts 2026-02-02 10:46:40,101 INFO tgt_gen_alone(): 0 2026-02-02 10:46:40,101 INFO tgt_gen() 2026-02-02 10:46:40,121 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0 2026-02-02 10:46:40,123 INFO TgtMsg: 0 0 2026-02-02 10:46:40,123 INFO Tgt: 1 @ 1180 2026-02-02 10:46:40,124 INFO Check that B9 b9_t_num is between 1 and 2 2026-02-02 10:46:40,124 INFO OK: read value = 1 2026-02-02 10:46:40,124 INFO Check that B9 b9_t1_rng is between 1179 and 1186 2026-02-02 10:46:40,124 INFO OK: read value = 1180 2026-02-02 10:46:40,124 INFO [MOCK] Log stopped 2026-02-02 10:46:40,124 INFO Repetition 1 of 3 2026-02-02 10:46:40,124 DEBUG [MOCK] Serial statistics reset 2026-02-02 10:46:40,124 INFO The test operator is required to switch off the target and wait 3 seconds. 2026-02-02 10:46:41,153 INFO Set MAIN_POWER to False 2026-02-02 10:46:41,156 INFO [MOCK] Power OFF 2026-02-02 10:46:41,156 INFO [MOCK] 1553 Interface stopped 2026-02-02 10:46:46,172 INFO Check that MAIN_POWER is equal to 0 2026-02-02 10:46:46,172 INFO OK: read value = False 2026-02-02 10:46:50,173 INFO The test operator is required to switch on the target. 2026-02-02 10:46:50,174 INFO Set MAIN_POWER to True 2026-02-02 10:46:50,174 INFO [MOCK] Power ON 2026-02-02 10:46:50,175 INFO ==================================================================================================== [CRITICAL DEBUG] _initialize_field_values() CALLED ==================================================================================================== 2026-02-02 10:46:50,175 INFO run_count = 1 2026-02-02 10:46:50,175 INFO SIMULATION_SCENARIO = 'mixed' 2026-02-02 10:46:50,175 INFO current_scenario = 'mixed' 2026-02-02 10:46:50,175 INFO _scenario_list = ['normal', 'normal', 'recycle_recovery_2'] 2026-02-02 10:46:50,175 INFO [DEBUG] Entering MIXED MODE branch 2026-02-02 10:46:50,175 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='normal' 2026-02-02 10:46:50,175 INFO [DEBUG] About to call _log_scenario_info('normal', 1, 3) 2026-02-02 10:46:50,175 INFO 2026-02-02 10:46:50,175 INFO #################################################################################################### 2026-02-02 10:46:50,175 INFO #################################################################################################### 2026-02-02 10:46:50,179 INFO ### RUN 1/3: NORMAL OPERATION 2026-02-02 10:46:50,179 INFO #################################################################################################### 2026-02-02 10:46:50,179 INFO 2026-02-02 10:46:50,179 INFO SCENARIO: normal 2026-02-02 10:46:50,179 INFO DESCRIPTION: All systems operational - no failures 2026-02-02 10:46:50,179 INFO 2026-02-02 10:46:50,180 INFO EXPECTED FAILURES: 2026-02-02 10:46:50,180 INFO (none) 2026-02-02 10:46:50,180 INFO 2026-02-02 10:46:50,181 INFO EXPECTED PASSES: 2026-02-02 10:46:50,181 INFO ✓ All B6 status fields (except pedestal) 2026-02-02 10:46:50,182 INFO ✓ All B8 diagnostic fields 2026-02-02 10:46:50,182 INFO ✓ Target generation 2026-02-02 10:46:50,182 INFO 2026-02-02 10:46:50,187 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present) 2026-02-02 10:46:50,187 INFO 2026-02-02 10:46:50,187 INFO #################################################################################################### 2026-02-02 10:46:50,187 INFO #################################################################################################### 2026-02-02 10:46:50,187 INFO 2026-02-02 10:46:50,188 INFO [DEBUG] _log_scenario_info() completed 2026-02-02 10:46:50,188 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected) 2026-02-02 10:46:50,188 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1) 2026-02-02 10:46:55,197 INFO Check that MAIN_POWER is equal to 1 2026-02-02 10:46:55,197 INFO OK: read value = True 2026-02-02 10:46:55,309 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100 2026-02-02 10:46:55,310 INFO Test terminated unexpectedly :'MockGrifoInstrumentInterface' object has no attribute 'default_timeout' 2026-02-02 10:46:55,310 INFO Stop Time: 2026-02-02 10:46:40.090391 2026-02-02 10:46:55,311 INFO Test execution time: 0:00:15.220005 2026-02-02 10:46:55,312 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3 Total Step 6: Success 6 (100.00%), Failed 0 (0.00%),