2026-02-02 14:29:16,101 INFO Start Time: 2026-02-02 14:29:16.101333
2026-02-02 14:29:16,101 INFO [MOCK] Serial terminal initialized
2026-02-02 14:29:16,101 INFO [MOCK] Serial terminal connected
2026-02-02 14:29:16,101 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 14:29:16,211 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 14:29:16,211 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-02-02 14:29:16,222 INFO Repetition 1 of 3
2026-02-02 14:29:16,222 DEBUG [MOCK] Serial statistics reset
2026-02-02 14:29:16,222 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 14:29:17,235 INFO Set MAIN_POWER to False
2026-02-02 14:29:17,235 INFO [MOCK] Power OFF
2026-02-02 14:29:17,235 INFO [MOCK] 1553 Interface stopped
2026-02-02 14:29:22,242 INFO Check that MAIN_POWER is equal to 0
2026-02-02 14:29:22,242 INFO OK: read value = False
2026-02-02 14:29:26,253 INFO The test operator is required to switch on the target.
2026-02-02 14:29:26,253 INFO Set MAIN_POWER to True
2026-02-02 14:29:26,253 INFO [MOCK] Power ON
2026-02-02 14:29:26,253 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 14:29:26,253 INFO run_count = 1
2026-02-02 14:29:26,253 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 14:29:26,253 INFO current_scenario = 'mixed'
2026-02-02 14:29:26,253 INFO _scenario_list = ['agc_tests_fail', 'normal', 'mixed_b8_failures']
2026-02-02 14:29:26,253 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 14:29:26,253 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='agc_tests_fail'
2026-02-02 14:29:26,253 INFO [DEBUG] About to call _log_scenario_info('agc_tests_fail', 1, 3)
2026-02-02 14:29:26,253 INFO
2026-02-02 14:29:26,253 INFO ####################################################################################################
2026-02-02 14:29:26,253 INFO ####################################################################################################
2026-02-02 14:29:26,253 INFO ### RUN 1/3: AGC TEST FAILURES
2026-02-02 14:29:26,253 INFO ####################################################################################################
2026-02-02 14:29:26,253 INFO
2026-02-02 14:29:26,253 INFO SCENARIO: agc_tests_fail
2026-02-02 14:29:26,253 INFO DESCRIPTION: Individual AGC tests fail (AGC1, AGC2, AGC5)
2026-02-02 14:29:26,253 INFO
2026-02-02 14:29:26,253 INFO EXPECTED FAILURES:
2026-02-02 14:29:26,253 INFO ✗ B8: test_agc1_internal_xyp_ram = FAIL
2026-02-02 14:29:26,253 INFO ✗ B8: test_agc2_external_xyp_ram = FAIL
2026-02-02 14:29:26,253 INFO ✗ B8: test_agc5_dual_port_ram = FAIL
2026-02-02 14:29:26,253 INFO
2026-02-02 14:29:26,253 INFO EXPECTED PASSES:
2026-02-02 14:29:26,259 INFO ✓ B6 status fields
2026-02-02 14:29:26,259 INFO ✓ Other B8 tests
2026-02-02 14:29:26,259 INFO
2026-02-02 14:29:26,260 INFO NOTES: Demonstrates granular test failure analysis - AGC memory subsystem failures
2026-02-02 14:29:26,260 INFO
2026-02-02 14:29:26,260 INFO ####################################################################################################
2026-02-02 14:29:26,260 INFO ####################################################################################################
2026-02-02 14:29:26,261 INFO
2026-02-02 14:29:26,261 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 14:29:26,261 INFO [MOCK APPLY] ✗ B8 failures only (no B6 category failure): AGC1, AGC2, AGC5 (memory tests)
2026-02-02 14:29:26,261 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1)
2026-02-02 14:29:31,272 INFO Check that MAIN_POWER is equal to 1
2026-02-02 14:29:31,272 INFO OK: read value = True
2026-02-02 14:29:31,377 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 14:29:31,583 INFO [MOCK] BIT report available after 5.3s
2026-02-02 14:29:31,614 INFO BIT report available after 0.2s
2026-02-02 14:29:31,614 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 14:29:31,614 INFO OK: read value = false
2026-02-02 14:29:31,614 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 14:29:31,615 WARNING CHECK ERROR: read value = true
2026-02-02 14:29:31,615 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 14:29:31,615 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 14:29:31,615 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 14:29:31,615 INFO OK: read value = false
2026-02-02 14:29:31,615 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 14:29:31,615 INFO OK: read value = false
2026-02-02 14:29:31,616 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 14:29:31,616 INFO OK: read value = false
2026-02-02 14:29:31,616 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 14:29:31,616 INFO OK: read value = false
2026-02-02 14:29:31,617 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 14:29:31,617 INFO OK: read value = false
2026-02-02 14:29:31,617 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 14:29:31,617 INFO OK: read value = false
2026-02-02 14:29:31,617 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 14:29:31,617 INFO OK: read value = false
2026-02-02 14:29:31,617 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 14:29:31,618 INFO OK: read value = false
2026-02-02 14:29:31,618 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 14:29:31,618 INFO OK: read value = false
2026-02-02 14:29:31,618 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 14:29:31,618 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 14:29:31,619 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 14:29:31,619 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 14:29:31,619 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 14:29:31,619 INFO Known failures (HW setup): 2
2026-02-02 14:29:31,620 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 14:29:31,620 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 14:29:31,620 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 14:29:31,620 INFO OK: read value = false
2026-02-02 14:29:31,620 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 14:29:31,621 INFO OK: read value = false
2026-02-02 14:29:31,621 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 14:29:31,621 INFO OK: read value = false
2026-02-02 14:29:31,622 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 14:29:31,622 INFO OK: read value = false
2026-02-02 14:29:31,622 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 14:29:31,622 INFO OK: read value = false
2026-02-02 14:29:31,622 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 14:29:31,623 INFO OK: read value = false
2026-02-02 14:29:31,623 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 14:29:31,623 INFO OK: read value = false
2026-02-02 14:29:31,623 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 14:29:31,623 INFO OK: read value = false
2026-02-02 14:29:31,623 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 14:29:31,623 INFO OK: read value = false
2026-02-02 14:29:31,624 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 14:29:31,624 WARNING CHECK ERROR: read value = 0
2026-02-02 14:29:31,624 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 14:29:31,624 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 14:29:31,624 INFO OK: read value = false
2026-02-02 14:29:31,624 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 14:29:31,625 INFO OK: read value = false
2026-02-02 14:29:31,625 WARNING B8_Degradation: 1/12 failures
2026-02-02 14:29:31,625 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 14:29:31,625 INFO OK: read value = false
2026-02-02 14:29:31,625 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 14:29:31,625 INFO OK: read value = false
2026-02-02 14:29:31,626 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 14:29:31,626 INFO OK: read value = false
2026-02-02 14:29:31,626 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 14:29:31,626 INFO OK: read value = false
2026-02-02 14:29:31,627 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 14:29:31,627 INFO OK: read value = false
2026-02-02 14:29:31,627 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 14:29:31,627 INFO OK: read value = false
2026-02-02 14:29:31,627 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 14:29:31,627 INFO OK: read value = false
2026-02-02 14:29:31,627 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 14:29:31,628 INFO OK: read value = false
2026-02-02 14:29:31,628 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 14:29:31,628 INFO OK: read value = false
2026-02-02 14:29:31,628 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 14:29:31,628 INFO OK: read value = false
2026-02-02 14:29:31,628 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 14:29:31,629 INFO OK: read value = false
2026-02-02 14:29:31,629 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 14:29:31,629 INFO OK: read value = false
2026-02-02 14:29:31,629 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 14:29:31,630 INFO OK: read value = false
2026-02-02 14:29:31,630 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 14:29:31,630 INFO OK: read value = false
2026-02-02 14:29:31,630 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 14:29:31,630 INFO OK: read value = false
2026-02-02 14:29:31,630 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 14:29:31,631 INFO OK: read value = false
2026-02-02 14:29:31,631 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 14:29:31,631 INFO OK: read value = false
2026-02-02 14:29:31,631 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 14:29:31,631 INFO OK: read value = false
2026-02-02 14:29:31,631 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 14:29:31,631 INFO OK: read value = false
2026-02-02 14:29:31,631 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 14:29:31,632 INFO OK: read value = false
2026-02-02 14:29:31,632 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 14:29:31,632 INFO OK: read value = false
2026-02-02 14:29:31,632 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 14:29:31,632 INFO OK: read value = false
2026-02-02 14:29:31,632 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 14:29:31,632 INFO OK: read value = false
2026-02-02 14:29:31,632 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 14:29:31,632 INFO OK: read value = false
2026-02-02 14:29:31,632 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 14:29:31,633 INFO OK: read value = false
2026-02-02 14:29:31,633 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 14:29:31,633 INFO OK: read value = false
2026-02-02 14:29:31,633 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 14:29:31,633 INFO OK: read value = false
2026-02-02 14:29:31,633 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 14:29:31,633 INFO OK: read value = false
2026-02-02 14:29:31,633 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 14:29:31,634 INFO OK: read value = false
2026-02-02 14:29:31,634 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 14:29:31,634 INFO OK: read value = false
2026-02-02 14:29:31,634 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 14:29:31,634 INFO OK: read value = false
2026-02-02 14:29:31,634 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 14:29:31,634 INFO OK: read value = false
2026-02-02 14:29:31,635 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 14:29:31,635 INFO OK: read value = false
2026-02-02 14:29:31,635 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 14:29:31,635 INFO OK: read value = false
2026-02-02 14:29:31,636 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 14:29:31,636 INFO OK: read value = false
2026-02-02 14:29:31,636 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 14:29:31,636 INFO OK: read value = false
2026-02-02 14:29:31,636 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 14:29:31,636 INFO OK: read value = false
2026-02-02 14:29:31,637 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 14:29:31,637 INFO OK: read value = false
2026-02-02 14:29:31,637 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 14:29:31,638 INFO OK: read value = false
2026-02-02 14:29:31,638 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 14:29:31,638 INFO OK: read value = false
2026-02-02 14:29:31,643 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 14:29:31,643 INFO OK: read value = false
2026-02-02 14:29:31,643 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 14:29:31,643 INFO OK: read value = false
2026-02-02 14:29:31,643 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 14:29:31,643 INFO OK: read value = false
2026-02-02 14:29:31,644 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 14:29:31,644 INFO OK: read value = false
2026-02-02 14:29:31,644 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 14:29:31,644 INFO OK: read value = false
2026-02-02 14:29:31,645 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 14:29:31,645 INFO OK: read value = false
2026-02-02 14:29:31,645 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 14:29:31,645 INFO OK: read value = false
2026-02-02 14:29:31,645 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 14:29:31,646 INFO OK: read value = false
2026-02-02 14:29:31,646 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 14:29:31,646 WARNING CHECK ERROR: read value = true
2026-02-02 14:29:31,646 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 14:29:31,646 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 14:29:31,647 WARNING CHECK ERROR: read value = true
2026-02-02 14:29:31,647 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 14:29:31,647 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 14:29:31,647 WARNING CHECK ERROR: read value = true
2026-02-02 14:29:31,647 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 14:29:31,647 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 14:29:31,647 INFO OK: read value = false
2026-02-02 14:29:31,648 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 14:29:31,648 INFO OK: read value = false
2026-02-02 14:29:31,648 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 14:29:31,648 INFO OK: read value = false
2026-02-02 14:29:31,648 WARNING B8_Test_AGC: 3/11 failures
2026-02-02 14:29:31,648 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 14:29:31,648 INFO OK: read value = false
2026-02-02 14:29:31,648 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 14:29:31,648 INFO OK: read value = false
2026-02-02 14:29:31,648 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 14:29:31,648 INFO OK: read value = false
2026-02-02 14:29:31,650 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 14:29:31,650 INFO OK: read value = false
2026-02-02 14:29:31,650 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 14:29:31,650 INFO OK: read value = false
2026-02-02 14:29:31,650 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 14:29:31,650 INFO OK: read value = false
2026-02-02 14:29:31,650 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 14:29:31,650 INFO OK: read value = false
2026-02-02 14:29:31,650 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 14:29:31,650 INFO OK: read value = false
2026-02-02 14:29:31,650 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 14:29:31,650 INFO OK: read value = false
2026-02-02 14:29:31,650 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 14:29:31,652 INFO OK: read value = false
2026-02-02 14:29:31,652 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 14:29:31,652 INFO OK: read value = false
2026-02-02 14:29:31,652 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 14:29:31,652 INFO OK: read value = false
2026-02-02 14:29:31,652 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 14:29:31,652 INFO OK: read value = false
2026-02-02 14:29:31,652 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 14:29:31,652 INFO OK: read value = false
2026-02-02 14:29:31,652 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 14:29:31,652 INFO OK: read value = false
2026-02-02 14:29:31,652 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 14:29:31,652 INFO OK: read value = false
2026-02-02 14:29:31,654 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 14:29:31,654 INFO OK: read value = false
2026-02-02 14:29:31,654 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 14:29:31,654 INFO OK: read value = false
2026-02-02 14:29:31,654 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 14:29:31,654 INFO OK: read value = false
2026-02-02 14:29:31,654 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 14:29:31,654 INFO OK: read value = false
2026-02-02 14:29:31,654 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 14:29:31,654 INFO OK: read value = false
2026-02-02 14:29:31,655 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 14:29:31,655 INFO OK: read value = false
2026-02-02 14:29:31,655 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 14:29:31,655 INFO OK: read value = false
2026-02-02 14:29:31,655 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 14:29:31,655 INFO OK: read value = false
2026-02-02 14:29:31,655 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 14:29:31,655 INFO OK: read value = false
2026-02-02 14:29:31,656 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 14:29:31,656 INFO OK: read value = false
2026-02-02 14:29:31,656 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 14:29:31,656 INFO OK: read value = false
2026-02-02 14:29:31,656 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 14:29:31,656 INFO OK: read value = false
2026-02-02 14:29:31,656 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 14:29:31,656 INFO OK: read value = false
2026-02-02 14:29:31,657 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 14:29:31,657 INFO OK: read value = false
2026-02-02 14:29:31,657 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 14:29:31,657 INFO OK: read value = false
2026-02-02 14:29:31,657 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 14:29:31,657 INFO OK: read value = false
2026-02-02 14:29:31,657 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 14:29:31,658 INFO OK: read value = false
2026-02-02 14:29:31,658 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 14:29:31,658 INFO OK: read value = false
2026-02-02 14:29:31,658 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 14:29:31,658 INFO OK: read value = false
2026-02-02 14:29:31,658 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 14:29:31,658 INFO OK: read value = false
2026-02-02 14:29:31,658 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 14:29:31,658 INFO OK: read value = false
2026-02-02 14:29:31,659 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 14:29:31,659 INFO OK: read value = false
2026-02-02 14:29:31,659 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 14:29:31,659 INFO OK: read value = false
2026-02-02 14:29:31,659 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 14:29:31,659 INFO OK: read value = false
2026-02-02 14:29:31,659 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 14:29:31,659 INFO OK: read value = false
2026-02-02 14:29:31,660 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 14:29:31,660 INFO OK: read value = false
2026-02-02 14:29:31,660 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 14:29:31,660 INFO OK: read value = false
2026-02-02 14:29:31,660 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 14:29:31,660 INFO OK: read value = false
2026-02-02 14:29:31,660 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 14:29:31,661 INFO OK: read value = false
2026-02-02 14:29:31,661 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 14:29:31,661 INFO OK: read value = false
2026-02-02 14:29:31,661 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 14:29:31,661 INFO OK: read value = false
2026-02-02 14:29:31,662 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 14:29:31,662 INFO OK: read value = false
2026-02-02 14:29:31,662 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 14:29:31,662 INFO OK: read value = false
2026-02-02 14:29:31,662 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 14:29:31,662 INFO OK: read value = false
2026-02-02 14:29:31,662 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 14:29:31,662 INFO OK: read value = false
2026-02-02 14:29:31,662 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 14:29:31,662 INFO OK: read value = false
2026-02-02 14:29:31,663 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 14:29:31,663 INFO OK: read value = false
2026-02-02 14:29:31,663 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 14:29:31,663 INFO OK: read value = false
2026-02-02 14:29:31,663 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 14:29:31,664 INFO OK: read value = false
2026-02-02 14:29:31,664 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 14:29:31,664 INFO OK: read value = false
2026-02-02 14:29:31,664 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 14:29:31,664 INFO OK: read value = false
2026-02-02 14:29:31,664 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 14:29:31,665 INFO OK: read value = false
2026-02-02 14:29:31,665 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 14:29:31,665 INFO OK: read value = false
2026-02-02 14:29:31,665 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 14:29:31,665 INFO OK: read value = false
2026-02-02 14:29:31,665 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 14:29:31,665 INFO OK: read value = false
2026-02-02 14:29:31,665 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 14:29:31,666 INFO OK: read value = false
2026-02-02 14:29:31,666 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 14:29:31,666 INFO OK: read value = false
2026-02-02 14:29:31,666 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 14:29:31,666 INFO OK: read value = false
2026-02-02 14:29:31,666 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 14:29:31,666 INFO OK: read value = false
2026-02-02 14:29:31,667 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 14:29:31,667 INFO OK: read value = false
2026-02-02 14:29:31,667 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 14:29:31,667 INFO OK: read value = false
2026-02-02 14:29:31,667 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 14:29:31,667 INFO OK: read value = false
2026-02-02 14:29:31,667 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 14:29:31,667 INFO OK: read value = false
2026-02-02 14:29:31,668 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 14:29:31,668 INFO OK: read value = false
2026-02-02 14:29:31,668 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 14:29:31,668 INFO OK: read value = false
2026-02-02 14:29:31,668 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 14:29:31,668 INFO OK: read value = false
2026-02-02 14:29:31,668 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 14:29:31,669 INFO OK: read value = false
2026-02-02 14:29:31,669 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 14:29:31,669 INFO OK: read value = false
2026-02-02 14:29:31,669 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 14:29:31,669 INFO OK: read value = false
2026-02-02 14:29:31,669 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 14:29:31,669 INFO OK: read value = false
2026-02-02 14:29:31,669 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 14:29:31,670 INFO OK: read value = false
2026-02-02 14:29:31,670 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 14:29:31,670 INFO OK: read value = false
2026-02-02 14:29:31,670 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 14:29:31,670 INFO OK: read value = false
2026-02-02 14:29:31,670 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 14:29:31,670 INFO OK: read value = false
2026-02-02 14:29:31,670 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 14:29:31,671 INFO OK: read value = false
2026-02-02 14:29:31,671 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 14:29:31,671 INFO OK: read value = false
2026-02-02 14:29:31,671 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 14:29:31,671 INFO OK: read value = false
2026-02-02 14:29:31,671 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 14:29:31,671 INFO OK: read value = false
2026-02-02 14:29:31,672 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 14:29:31,672 INFO OK: read value = false
2026-02-02 14:29:31,672 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 14:29:31,672 INFO OK: read value = false
2026-02-02 14:29:31,672 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 14:29:31,672 INFO OK: read value = false
2026-02-02 14:29:31,672 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 14:29:31,672 INFO OK: read value = false
2026-02-02 14:29:31,672 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 14:29:31,672 INFO OK: read value = false
2026-02-02 14:29:31,673 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 14:29:31,673 INFO OK: read value = false
2026-02-02 14:29:31,673 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 14:29:31,673 INFO OK: read value = false
2026-02-02 14:29:31,673 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 14:29:31,673 INFO OK: read value = false
2026-02-02 14:29:31,673 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 14:29:31,673 INFO OK: read value = false
2026-02-02 14:29:31,673 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 14:29:31,674 INFO OK: read value = false
2026-02-02 14:29:31,674 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 14:29:31,674 INFO OK: read value = false
2026-02-02 14:29:31,674 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 14:29:31,674 INFO OK: read value = false
2026-02-02 14:29:31,674 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 14:29:31,674 INFO OK: read value = false
2026-02-02 14:29:31,675 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 14:29:31,675 INFO OK: read value = false
2026-02-02 14:29:31,675 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 14:29:31,675 INFO OK: read value = false
2026-02-02 14:29:31,675 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 14:29:31,676 INFO OK: read value = false
2026-02-02 14:29:31,676 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 14:29:31,676 INFO OK: read value = false
2026-02-02 14:29:31,676 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 14:29:31,676 INFO OK: read value = false
2026-02-02 14:29:31,676 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 14:29:31,676 INFO OK: read value = false
2026-02-02 14:29:31,677 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 14:29:31,677 INFO OK: read value = false
2026-02-02 14:29:31,677 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 14:29:31,677 INFO OK: read value = false
2026-02-02 14:29:31,677 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 14:29:31,677 INFO OK: read value = false
2026-02-02 14:29:31,677 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 14:29:31,677 INFO OK: read value = false
2026-02-02 14:29:31,677 INFO [Run 1] B8 Diagnostics: 173 checked, 169 pass, 4 fail
2026-02-02 14:29:31,677 WARNING B8_Degradation: 1 failures - fail
2026-02-02 14:29:31,677 WARNING B8_Test_AGC: 3 failures - ram, ram, ram
2026-02-02 14:29:31,679 INFO 0.0s remaining ...
2026-02-02 14:29:31,679 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 14:29:31,679 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3
Total Step 190: Success 184 (96.84%), Failed 6 (3.16%),
2026-02-02 14:29:31,680 INFO Repetition 2 of 3
2026-02-02 14:29:31,680 DEBUG [MOCK] Serial statistics reset
2026-02-02 14:29:31,680 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 14:29:32,692 INFO Set MAIN_POWER to False
2026-02-02 14:29:32,692 INFO [MOCK] Power OFF
2026-02-02 14:29:32,692 INFO [MOCK] 1553 Interface stopped
2026-02-02 14:29:37,700 INFO Check that MAIN_POWER is equal to 0
2026-02-02 14:29:37,700 INFO OK: read value = False
2026-02-02 14:29:41,702 INFO The test operator is required to switch on the target.
2026-02-02 14:29:41,703 INFO Set MAIN_POWER to True
2026-02-02 14:29:41,703 INFO [MOCK] Power ON
2026-02-02 14:29:41,704 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 14:29:41,704 INFO run_count = 2
2026-02-02 14:29:41,705 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 14:29:41,705 INFO current_scenario = 'mixed'
2026-02-02 14:29:41,705 INFO _scenario_list = ['agc_tests_fail', 'normal', 'mixed_b8_failures']
2026-02-02 14:29:41,706 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 14:29:41,707 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='normal'
2026-02-02 14:29:41,707 INFO [DEBUG] About to call _log_scenario_info('normal', 2, 3)
2026-02-02 14:29:41,707 INFO
2026-02-02 14:29:41,707 INFO ####################################################################################################
2026-02-02 14:29:41,708 INFO ####################################################################################################
2026-02-02 14:29:41,708 INFO ### RUN 2/3: NORMAL OPERATION
2026-02-02 14:29:41,708 INFO ####################################################################################################
2026-02-02 14:29:41,710 INFO
2026-02-02 14:29:41,710 INFO SCENARIO: normal
2026-02-02 14:29:41,710 INFO DESCRIPTION: All systems operational - no failures
2026-02-02 14:29:41,710 INFO
2026-02-02 14:29:41,710 INFO EXPECTED FAILURES:
2026-02-02 14:29:41,710 INFO (none)
2026-02-02 14:29:41,711 INFO
2026-02-02 14:29:41,711 INFO EXPECTED PASSES:
2026-02-02 14:29:41,711 INFO ✓ All B6 status fields (except pedestal)
2026-02-02 14:29:41,712 INFO ✓ All B8 diagnostic fields
2026-02-02 14:29:41,712 INFO ✓ Target generation
2026-02-02 14:29:41,712 INFO
2026-02-02 14:29:41,712 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present)
2026-02-02 14:29:41,712 INFO
2026-02-02 14:29:41,713 INFO ####################################################################################################
2026-02-02 14:29:41,713 INFO ####################################################################################################
2026-02-02 14:29:41,713 INFO
2026-02-02 14:29:41,713 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 14:29:41,713 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected)
2026-02-02 14:29:41,715 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-02-02 14:29:46,728 INFO Check that MAIN_POWER is equal to 1
2026-02-02 14:29:46,729 INFO OK: read value = True
2026-02-02 14:29:46,837 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 14:29:47,045 INFO [MOCK] BIT report available after 5.3s
2026-02-02 14:29:47,076 INFO BIT report available after 0.2s
2026-02-02 14:29:47,076 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 14:29:47,077 INFO OK: read value = false
2026-02-02 14:29:47,077 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 14:29:47,077 WARNING CHECK ERROR: read value = true
2026-02-02 14:29:47,077 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 14:29:47,078 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 14:29:47,078 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 14:29:47,078 INFO OK: read value = false
2026-02-02 14:29:47,079 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 14:29:47,079 INFO OK: read value = false
2026-02-02 14:29:47,079 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 14:29:47,079 INFO OK: read value = false
2026-02-02 14:29:47,080 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 14:29:47,080 INFO OK: read value = false
2026-02-02 14:29:47,080 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 14:29:47,080 INFO OK: read value = false
2026-02-02 14:29:47,080 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 14:29:47,081 INFO OK: read value = false
2026-02-02 14:29:47,081 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 14:29:47,081 INFO OK: read value = false
2026-02-02 14:29:47,081 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 14:29:47,081 INFO OK: read value = false
2026-02-02 14:29:47,081 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 14:29:47,081 INFO OK: read value = false
2026-02-02 14:29:47,081 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 14:29:47,082 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 14:29:47,082 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 14:29:47,082 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 14:29:47,082 INFO [Run 2] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 14:29:47,082 INFO Known failures (HW setup): 2
2026-02-02 14:29:47,082 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 14:29:47,083 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 14:29:47,083 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 14:29:47,083 INFO OK: read value = false
2026-02-02 14:29:47,083 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 14:29:47,083 INFO OK: read value = false
2026-02-02 14:29:47,083 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 14:29:47,084 INFO OK: read value = false
2026-02-02 14:29:47,084 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 14:29:47,084 INFO OK: read value = false
2026-02-02 14:29:47,084 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 14:29:47,084 INFO OK: read value = false
2026-02-02 14:29:47,084 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 14:29:47,084 INFO OK: read value = false
2026-02-02 14:29:47,085 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 14:29:47,085 INFO OK: read value = false
2026-02-02 14:29:47,085 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 14:29:47,085 INFO OK: read value = false
2026-02-02 14:29:47,086 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 14:29:47,086 INFO OK: read value = false
2026-02-02 14:29:47,086 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 14:29:47,086 WARNING CHECK ERROR: read value = 0
2026-02-02 14:29:47,086 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 14:29:47,086 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 14:29:47,086 INFO OK: read value = false
2026-02-02 14:29:47,086 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 14:29:47,087 INFO OK: read value = false
2026-02-02 14:29:47,087 WARNING B8_Degradation: 1/12 failures
2026-02-02 14:29:47,087 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 14:29:47,087 INFO OK: read value = false
2026-02-02 14:29:47,088 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 14:29:47,088 INFO OK: read value = false
2026-02-02 14:29:47,088 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 14:29:47,088 INFO OK: read value = false
2026-02-02 14:29:47,088 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 14:29:47,088 INFO OK: read value = false
2026-02-02 14:29:47,088 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 14:29:47,089 INFO OK: read value = false
2026-02-02 14:29:47,089 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 14:29:47,089 INFO OK: read value = false
2026-02-02 14:29:47,089 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 14:29:47,089 INFO OK: read value = false
2026-02-02 14:29:47,089 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 14:29:47,090 INFO OK: read value = false
2026-02-02 14:29:47,090 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 14:29:47,090 INFO OK: read value = false
2026-02-02 14:29:47,090 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 14:29:47,093 INFO OK: read value = false
2026-02-02 14:29:47,093 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 14:29:47,093 INFO OK: read value = false
2026-02-02 14:29:47,093 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 14:29:47,094 INFO OK: read value = false
2026-02-02 14:29:47,094 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 14:29:47,094 INFO OK: read value = false
2026-02-02 14:29:47,094 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 14:29:47,094 INFO OK: read value = false
2026-02-02 14:29:47,094 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 14:29:47,094 INFO OK: read value = false
2026-02-02 14:29:47,095 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 14:29:47,095 INFO OK: read value = false
2026-02-02 14:29:47,095 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 14:29:47,095 INFO OK: read value = false
2026-02-02 14:29:47,095 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 14:29:47,095 INFO OK: read value = false
2026-02-02 14:29:47,096 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 14:29:47,096 INFO OK: read value = false
2026-02-02 14:29:47,096 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 14:29:47,096 INFO OK: read value = false
2026-02-02 14:29:47,097 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 14:29:47,097 INFO OK: read value = false
2026-02-02 14:29:47,097 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 14:29:47,097 INFO OK: read value = false
2026-02-02 14:29:47,098 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 14:29:47,098 INFO OK: read value = false
2026-02-02 14:29:47,098 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 14:29:47,098 INFO OK: read value = false
2026-02-02 14:29:47,099 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 14:29:47,099 INFO OK: read value = false
2026-02-02 14:29:47,099 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 14:29:47,099 INFO OK: read value = false
2026-02-02 14:29:47,099 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 14:29:47,099 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,100 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 14:29:47,100 INFO OK: read value = false
2026-02-02 14:29:47,103 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 14:29:47,103 INFO OK: read value = false
2026-02-02 14:29:47,104 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 14:29:47,104 INFO OK: read value = false
2026-02-02 14:29:47,104 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 14:29:47,104 INFO OK: read value = false
2026-02-02 14:29:47,105 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 14:29:47,105 INFO OK: read value = false
2026-02-02 14:29:47,105 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 14:29:47,106 INFO OK: read value = false
2026-02-02 14:29:47,106 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 14:29:47,106 INFO OK: read value = false
2026-02-02 14:29:47,107 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 14:29:47,107 INFO OK: read value = false
2026-02-02 14:29:47,107 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 14:29:47,108 INFO OK: read value = false
2026-02-02 14:29:47,108 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 14:29:47,109 INFO OK: read value = false
2026-02-02 14:29:47,109 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 14:29:47,109 INFO OK: read value = false
2026-02-02 14:29:47,109 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 14:29:47,110 INFO OK: read value = false
2026-02-02 14:29:47,110 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 14:29:47,111 INFO OK: read value = false
2026-02-02 14:29:47,111 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 14:29:47,111 INFO OK: read value = false
2026-02-02 14:29:47,112 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 14:29:47,112 INFO OK: read value = false
2026-02-02 14:29:47,112 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 14:29:47,112 INFO OK: read value = false
2026-02-02 14:29:47,113 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 14:29:47,113 INFO OK: read value = false
2026-02-02 14:29:47,113 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 14:29:47,113 INFO OK: read value = false
2026-02-02 14:29:47,113 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 14:29:47,114 INFO OK: read value = false
2026-02-02 14:29:47,114 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 14:29:47,114 INFO OK: read value = false
2026-02-02 14:29:47,114 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 14:29:47,114 INFO OK: read value = false
2026-02-02 14:29:47,114 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 14:29:47,115 INFO OK: read value = false
2026-02-02 14:29:47,115 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 14:29:47,115 INFO OK: read value = false
2026-02-02 14:29:47,115 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 14:29:47,115 INFO OK: read value = false
2026-02-02 14:29:47,116 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 14:29:47,116 INFO OK: read value = false
2026-02-02 14:29:47,116 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 14:29:47,116 INFO OK: read value = false
2026-02-02 14:29:47,116 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 14:29:47,116 INFO OK: read value = false
2026-02-02 14:29:47,117 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 14:29:47,117 INFO OK: read value = false
2026-02-02 14:29:47,117 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 14:29:47,117 INFO OK: read value = false
2026-02-02 14:29:47,118 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 14:29:47,118 INFO OK: read value = false
2026-02-02 14:29:47,118 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 14:29:47,118 INFO OK: read value = false
2026-02-02 14:29:47,118 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 14:29:47,119 INFO OK: read value = false
2026-02-02 14:29:47,119 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 14:29:47,119 INFO OK: read value = false
2026-02-02 14:29:47,120 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 14:29:47,120 INFO OK: read value = false
2026-02-02 14:29:47,121 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 14:29:47,121 INFO OK: read value = false
2026-02-02 14:29:47,121 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 14:29:47,122 INFO OK: read value = false
2026-02-02 14:29:47,122 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 14:29:47,122 INFO OK: read value = false
2026-02-02 14:29:47,122 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 14:29:47,123 INFO OK: read value = false
2026-02-02 14:29:47,123 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 14:29:47,123 INFO OK: read value = false
2026-02-02 14:29:47,123 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 14:29:47,124 INFO OK: read value = false
2026-02-02 14:29:47,124 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 14:29:47,124 INFO OK: read value = false
2026-02-02 14:29:47,124 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 14:29:47,124 INFO OK: read value = false
2026-02-02 14:29:47,124 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 14:29:47,125 INFO OK: read value = false
2026-02-02 14:29:47,125 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 14:29:47,125 INFO OK: read value = false
2026-02-02 14:29:47,125 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 14:29:47,126 INFO OK: read value = false
2026-02-02 14:29:47,126 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 14:29:47,126 INFO OK: read value = false
2026-02-02 14:29:47,126 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 14:29:47,126 INFO OK: read value = false
2026-02-02 14:29:47,127 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 14:29:47,127 INFO OK: read value = false
2026-02-02 14:29:47,127 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 14:29:47,127 INFO OK: read value = false
2026-02-02 14:29:47,127 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 14:29:47,128 INFO OK: read value = false
2026-02-02 14:29:47,128 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 14:29:47,128 INFO OK: read value = false
2026-02-02 14:29:47,129 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 14:29:47,129 INFO OK: read value = false
2026-02-02 14:29:47,129 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 14:29:47,129 INFO OK: read value = false
2026-02-02 14:29:47,130 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 14:29:47,130 INFO OK: read value = false
2026-02-02 14:29:47,130 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 14:29:47,130 INFO OK: read value = false
2026-02-02 14:29:47,131 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 14:29:47,131 INFO OK: read value = false
2026-02-02 14:29:47,131 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 14:29:47,131 INFO OK: read value = false
2026-02-02 14:29:47,132 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 14:29:47,132 INFO OK: read value = false
2026-02-02 14:29:47,132 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 14:29:47,133 INFO OK: read value = false
2026-02-02 14:29:47,133 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 14:29:47,133 INFO OK: read value = false
2026-02-02 14:29:47,134 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 14:29:47,134 INFO OK: read value = false
2026-02-02 14:29:47,135 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 14:29:47,135 INFO OK: read value = false
2026-02-02 14:29:47,135 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 14:29:47,135 INFO OK: read value = false
2026-02-02 14:29:47,135 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 14:29:47,135 INFO OK: read value = false
2026-02-02 14:29:47,135 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 14:29:47,136 INFO OK: read value = false
2026-02-02 14:29:47,136 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 14:29:47,136 INFO OK: read value = false
2026-02-02 14:29:47,136 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 14:29:47,137 INFO OK: read value = false
2026-02-02 14:29:47,137 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 14:29:47,137 INFO OK: read value = false
2026-02-02 14:29:47,138 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 14:29:47,138 INFO OK: read value = false
2026-02-02 14:29:47,138 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 14:29:47,138 INFO OK: read value = false
2026-02-02 14:29:47,138 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 14:29:47,138 INFO OK: read value = false
2026-02-02 14:29:47,139 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 14:29:47,139 INFO OK: read value = false
2026-02-02 14:29:47,139 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 14:29:47,139 INFO OK: read value = false
2026-02-02 14:29:47,139 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 14:29:47,140 INFO OK: read value = false
2026-02-02 14:29:47,140 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 14:29:47,140 INFO OK: read value = false
2026-02-02 14:29:47,140 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 14:29:47,140 INFO OK: read value = false
2026-02-02 14:29:47,140 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 14:29:47,141 INFO OK: read value = false
2026-02-02 14:29:47,141 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 14:29:47,141 INFO OK: read value = false
2026-02-02 14:29:47,141 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 14:29:47,141 INFO OK: read value = false
2026-02-02 14:29:47,141 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 14:29:47,142 INFO OK: read value = false
2026-02-02 14:29:47,142 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 14:29:47,142 INFO OK: read value = false
2026-02-02 14:29:47,142 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 14:29:47,142 INFO OK: read value = false
2026-02-02 14:29:47,142 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 14:29:47,142 INFO OK: read value = false
2026-02-02 14:29:47,142 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 14:29:47,143 INFO OK: read value = false
2026-02-02 14:29:47,143 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 14:29:47,144 INFO OK: read value = false
2026-02-02 14:29:47,144 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 14:29:47,144 INFO OK: read value = false
2026-02-02 14:29:47,144 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 14:29:47,144 INFO OK: read value = false
2026-02-02 14:29:47,144 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 14:29:47,145 INFO OK: read value = false
2026-02-02 14:29:47,145 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 14:29:47,145 INFO OK: read value = false
2026-02-02 14:29:47,145 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 14:29:47,146 INFO OK: read value = false
2026-02-02 14:29:47,146 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 14:29:47,146 INFO OK: read value = false
2026-02-02 14:29:47,146 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 14:29:47,146 INFO OK: read value = false
2026-02-02 14:29:47,146 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 14:29:47,147 INFO OK: read value = false
2026-02-02 14:29:47,147 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 14:29:47,147 INFO OK: read value = false
2026-02-02 14:29:47,148 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 14:29:47,148 INFO OK: read value = false
2026-02-02 14:29:47,148 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 14:29:47,148 INFO OK: read value = false
2026-02-02 14:29:47,148 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 14:29:47,148 INFO OK: read value = false
2026-02-02 14:29:47,148 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 14:29:47,148 INFO OK: read value = false
2026-02-02 14:29:47,148 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 14:29:47,149 INFO OK: read value = false
2026-02-02 14:29:47,149 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 14:29:47,149 INFO OK: read value = false
2026-02-02 14:29:47,149 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 14:29:47,149 INFO OK: read value = false
2026-02-02 14:29:47,150 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 14:29:47,150 INFO OK: read value = false
2026-02-02 14:29:47,150 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 14:29:47,150 INFO OK: read value = false
2026-02-02 14:29:47,150 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 14:29:47,150 INFO OK: read value = false
2026-02-02 14:29:47,153 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 14:29:47,153 INFO OK: read value = false
2026-02-02 14:29:47,153 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 14:29:47,153 INFO OK: read value = false
2026-02-02 14:29:47,153 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 14:29:47,153 INFO OK: read value = false
2026-02-02 14:29:47,153 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 14:29:47,153 INFO OK: read value = false
2026-02-02 14:29:47,154 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 14:29:47,154 INFO OK: read value = false
2026-02-02 14:29:47,154 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 14:29:47,155 INFO OK: read value = false
2026-02-02 14:29:47,155 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 14:29:47,155 INFO OK: read value = false
2026-02-02 14:29:47,155 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 14:29:47,156 INFO OK: read value = false
2026-02-02 14:29:47,156 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 14:29:47,157 INFO OK: read value = false
2026-02-02 14:29:47,157 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 14:29:47,157 INFO OK: read value = false
2026-02-02 14:29:47,158 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 14:29:47,158 INFO OK: read value = false
2026-02-02 14:29:47,158 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 14:29:47,158 INFO OK: read value = false
2026-02-02 14:29:47,158 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 14:29:47,159 INFO OK: read value = false
2026-02-02 14:29:47,159 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 14:29:47,159 INFO OK: read value = false
2026-02-02 14:29:47,159 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 14:29:47,160 INFO OK: read value = false
2026-02-02 14:29:47,160 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 14:29:47,160 INFO OK: read value = false
2026-02-02 14:29:47,160 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 14:29:47,160 INFO OK: read value = false
2026-02-02 14:29:47,161 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 14:29:47,161 INFO OK: read value = false
2026-02-02 14:29:47,161 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 14:29:47,162 INFO OK: read value = false
2026-02-02 14:29:47,162 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 14:29:47,162 INFO OK: read value = false
2026-02-02 14:29:47,163 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 14:29:47,163 INFO OK: read value = false
2026-02-02 14:29:47,163 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 14:29:47,163 INFO OK: read value = false
2026-02-02 14:29:47,163 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 14:29:47,164 INFO OK: read value = false
2026-02-02 14:29:47,164 INFO [Run 2] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 14:29:47,165 WARNING B8_Degradation: 1 failures - fail
2026-02-02 14:29:47,165 INFO 0.0s remaining ...
2026-02-02 14:29:47,165 INFO [Run 2] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 14:29:47,166 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3
Total Step 190: Success 187 (98.42%), Failed 3 (1.58%),
2026-02-02 14:29:47,167 INFO Repetition 3 of 3
2026-02-02 14:29:47,167 DEBUG [MOCK] Serial statistics reset
2026-02-02 14:29:47,167 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 14:29:48,180 INFO Set MAIN_POWER to False
2026-02-02 14:29:48,180 INFO [MOCK] Power OFF
2026-02-02 14:29:48,180 INFO [MOCK] 1553 Interface stopped
2026-02-02 14:29:53,188 INFO Check that MAIN_POWER is equal to 0
2026-02-02 14:29:53,188 INFO OK: read value = False
2026-02-02 14:29:57,189 INFO The test operator is required to switch on the target.
2026-02-02 14:29:57,189 INFO Set MAIN_POWER to True
2026-02-02 14:29:57,189 INFO [MOCK] Power ON
2026-02-02 14:29:57,189 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 14:29:57,189 INFO run_count = 3
2026-02-02 14:29:57,189 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 14:29:57,189 INFO current_scenario = 'mixed'
2026-02-02 14:29:57,189 INFO _scenario_list = ['agc_tests_fail', 'normal', 'mixed_b8_failures']
2026-02-02 14:29:57,189 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 14:29:57,189 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='mixed_b8_failures'
2026-02-02 14:29:57,189 INFO [DEBUG] About to call _log_scenario_info('mixed_b8_failures', 3, 3)
2026-02-02 14:29:57,189 INFO
2026-02-02 14:29:57,189 INFO ####################################################################################################
2026-02-02 14:29:57,189 INFO ####################################################################################################
2026-02-02 14:29:57,189 INFO ### RUN 3/3: MIXED B8 TEST FAILURES
2026-02-02 14:29:57,189 INFO ####################################################################################################
2026-02-02 14:29:57,189 INFO
2026-02-02 14:29:57,189 INFO SCENARIO: mixed_b8_failures
2026-02-02 14:29:57,189 INFO DESCRIPTION: Random selection of individual B8 test failures across subsystems
2026-02-02 14:29:57,189 INFO
2026-02-02 14:29:57,189 INFO EXPECTED FAILURES:
2026-02-02 14:29:57,189 INFO ✗ Variable - random B8 tests from SP, TX, AGC, DP, IS categories
2026-02-02 14:29:57,189 INFO
2026-02-02 14:29:57,189 INFO EXPECTED PASSES:
2026-02-02 14:29:57,189 INFO ✓ B6 status fields (may show degradation)
2026-02-02 14:29:57,189 INFO ✓ Non-failed B8 tests
2026-02-02 14:29:57,189 INFO
2026-02-02 14:29:57,189 INFO NOTES: Best scenario to demonstrate test failure analysis with diverse test IDs
2026-02-02 14:29:57,189 INFO
2026-02-02 14:29:57,195 INFO ####################################################################################################
2026-02-02 14:29:57,195 INFO ####################################################################################################
2026-02-02 14:29:57,195 INFO
2026-02-02 14:29:57,195 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 14:29:57,195 INFO [MOCK APPLY] ✓ No random B8 failures triggered (all passed)
2026-02-02 14:29:57,195 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3)
2026-02-02 14:30:02,201 INFO Check that MAIN_POWER is equal to 1
2026-02-02 14:30:02,201 INFO OK: read value = True
2026-02-02 14:30:02,310 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 14:30:02,511 INFO [MOCK] BIT report available after 5.3s
2026-02-02 14:30:02,543 INFO BIT report available after 0.2s
2026-02-02 14:30:02,543 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 14:30:02,543 INFO OK: read value = false
2026-02-02 14:30:02,544 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 14:30:02,544 WARNING CHECK ERROR: read value = true
2026-02-02 14:30:02,544 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 14:30:02,544 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 14:30:02,544 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 14:30:02,545 INFO OK: read value = false
2026-02-02 14:30:02,545 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 14:30:02,545 INFO OK: read value = false
2026-02-02 14:30:02,545 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 14:30:02,546 INFO OK: read value = false
2026-02-02 14:30:02,546 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 14:30:02,546 INFO OK: read value = false
2026-02-02 14:30:02,546 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 14:30:02,546 INFO OK: read value = false
2026-02-02 14:30:02,546 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 14:30:02,547 INFO OK: read value = false
2026-02-02 14:30:02,547 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 14:30:02,547 INFO OK: read value = false
2026-02-02 14:30:02,547 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 14:30:02,547 INFO OK: read value = false
2026-02-02 14:30:02,547 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 14:30:02,548 INFO OK: read value = false
2026-02-02 14:30:02,548 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 14:30:02,548 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 14:30:02,548 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 14:30:02,548 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 14:30:02,548 INFO [Run 3] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 14:30:02,548 INFO Known failures (HW setup): 2
2026-02-02 14:30:02,549 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 14:30:02,549 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 14:30:02,549 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 14:30:02,549 INFO OK: read value = false
2026-02-02 14:30:02,549 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 14:30:02,549 INFO OK: read value = false
2026-02-02 14:30:02,550 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 14:30:02,550 INFO OK: read value = false
2026-02-02 14:30:02,550 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 14:30:02,550 INFO OK: read value = false
2026-02-02 14:30:02,550 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 14:30:02,550 INFO OK: read value = false
2026-02-02 14:30:02,550 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 14:30:02,550 INFO OK: read value = false
2026-02-02 14:30:02,551 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 14:30:02,551 INFO OK: read value = false
2026-02-02 14:30:02,551 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 14:30:02,551 INFO OK: read value = false
2026-02-02 14:30:02,551 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 14:30:02,551 INFO OK: read value = false
2026-02-02 14:30:02,551 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 14:30:02,552 WARNING CHECK ERROR: read value = 0
2026-02-02 14:30:02,552 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 14:30:02,552 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 14:30:02,552 INFO OK: read value = false
2026-02-02 14:30:02,552 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 14:30:02,552 INFO OK: read value = false
2026-02-02 14:30:02,553 WARNING B8_Degradation: 1/12 failures
2026-02-02 14:30:02,553 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 14:30:02,553 INFO OK: read value = false
2026-02-02 14:30:02,553 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 14:30:02,553 INFO OK: read value = false
2026-02-02 14:30:02,553 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 14:30:02,553 INFO OK: read value = false
2026-02-02 14:30:02,553 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 14:30:02,553 INFO OK: read value = false
2026-02-02 14:30:02,553 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 14:30:02,553 INFO OK: read value = false
2026-02-02 14:30:02,553 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 14:30:02,554 INFO OK: read value = false
2026-02-02 14:30:02,554 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 14:30:02,554 INFO OK: read value = false
2026-02-02 14:30:02,554 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 14:30:02,554 INFO OK: read value = false
2026-02-02 14:30:02,554 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 14:30:02,555 INFO OK: read value = false
2026-02-02 14:30:02,555 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 14:30:02,555 INFO OK: read value = false
2026-02-02 14:30:02,555 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 14:30:02,555 INFO OK: read value = false
2026-02-02 14:30:02,555 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 14:30:02,556 INFO OK: read value = false
2026-02-02 14:30:02,556 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 14:30:02,556 INFO OK: read value = false
2026-02-02 14:30:02,556 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 14:30:02,557 INFO OK: read value = false
2026-02-02 14:30:02,557 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 14:30:02,557 INFO OK: read value = false
2026-02-02 14:30:02,557 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 14:30:02,557 INFO OK: read value = false
2026-02-02 14:30:02,557 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 14:30:02,558 INFO OK: read value = false
2026-02-02 14:30:02,558 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 14:30:02,558 INFO OK: read value = false
2026-02-02 14:30:02,558 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 14:30:02,558 INFO OK: read value = false
2026-02-02 14:30:02,558 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 14:30:02,558 INFO OK: read value = false
2026-02-02 14:30:02,559 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 14:30:02,559 INFO OK: read value = false
2026-02-02 14:30:02,559 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 14:30:02,560 INFO OK: read value = false
2026-02-02 14:30:02,560 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 14:30:02,560 INFO OK: read value = false
2026-02-02 14:30:02,560 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 14:30:02,560 INFO OK: read value = false
2026-02-02 14:30:02,560 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 14:30:02,560 INFO OK: read value = false
2026-02-02 14:30:02,561 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 14:30:02,561 INFO OK: read value = false
2026-02-02 14:30:02,561 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 14:30:02,561 INFO OK: read value = false
2026-02-02 14:30:02,561 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 14:30:02,561 INFO OK: read value = false
2026-02-02 14:30:02,561 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 14:30:02,562 INFO OK: read value = false
2026-02-02 14:30:02,562 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 14:30:02,562 INFO OK: read value = false
2026-02-02 14:30:02,562 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 14:30:02,562 INFO OK: read value = false
2026-02-02 14:30:02,562 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 14:30:02,562 INFO OK: read value = false
2026-02-02 14:30:02,563 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 14:30:02,563 INFO OK: read value = false
2026-02-02 14:30:02,563 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 14:30:02,563 INFO OK: read value = false
2026-02-02 14:30:02,563 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 14:30:02,563 INFO OK: read value = false
2026-02-02 14:30:02,563 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 14:30:02,564 INFO OK: read value = false
2026-02-02 14:30:02,564 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 14:30:02,564 INFO OK: read value = false
2026-02-02 14:30:02,565 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 14:30:02,565 INFO OK: read value = false
2026-02-02 14:30:02,565 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 14:30:02,565 INFO OK: read value = false
2026-02-02 14:30:02,566 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 14:30:02,566 INFO OK: read value = false
2026-02-02 14:30:02,566 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 14:30:02,566 INFO OK: read value = false
2026-02-02 14:30:02,566 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 14:30:02,566 INFO OK: read value = false
2026-02-02 14:30:02,566 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 14:30:02,566 INFO OK: read value = false
2026-02-02 14:30:02,566 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 14:30:02,566 INFO OK: read value = false
2026-02-02 14:30:02,566 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 14:30:02,567 INFO OK: read value = false
2026-02-02 14:30:02,567 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 14:30:02,567 INFO OK: read value = false
2026-02-02 14:30:02,567 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 14:30:02,567 INFO OK: read value = false
2026-02-02 14:30:02,567 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 14:30:02,567 INFO OK: read value = false
2026-02-02 14:30:02,568 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 14:30:02,568 INFO OK: read value = false
2026-02-02 14:30:02,568 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 14:30:02,568 INFO OK: read value = false
2026-02-02 14:30:02,568 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 14:30:02,568 INFO OK: read value = false
2026-02-02 14:30:02,568 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 14:30:02,568 INFO OK: read value = false
2026-02-02 14:30:02,568 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 14:30:02,568 INFO OK: read value = false
2026-02-02 14:30:02,569 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 14:30:02,569 INFO OK: read value = false
2026-02-02 14:30:02,569 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 14:30:02,569 INFO OK: read value = false
2026-02-02 14:30:02,569 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 14:30:02,569 INFO OK: read value = false
2026-02-02 14:30:02,569 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 14:30:02,569 INFO OK: read value = false
2026-02-02 14:30:02,569 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 14:30:02,569 INFO OK: read value = false
2026-02-02 14:30:02,569 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 14:30:02,569 INFO OK: read value = false
2026-02-02 14:30:02,571 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 14:30:02,571 INFO OK: read value = false
2026-02-02 14:30:02,571 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 14:30:02,571 INFO OK: read value = false
2026-02-02 14:30:02,571 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 14:30:02,571 INFO OK: read value = false
2026-02-02 14:30:02,571 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 14:30:02,571 INFO OK: read value = false
2026-02-02 14:30:02,571 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 14:30:02,572 INFO OK: read value = false
2026-02-02 14:30:02,572 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 14:30:02,572 INFO OK: read value = false
2026-02-02 14:30:02,572 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 14:30:02,572 INFO OK: read value = false
2026-02-02 14:30:02,572 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 14:30:02,573 INFO OK: read value = false
2026-02-02 14:30:02,573 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 14:30:02,573 INFO OK: read value = false
2026-02-02 14:30:02,573 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 14:30:02,573 INFO OK: read value = false
2026-02-02 14:30:02,574 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 14:30:02,574 INFO OK: read value = false
2026-02-02 14:30:02,574 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 14:30:02,574 INFO OK: read value = false
2026-02-02 14:30:02,574 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 14:30:02,574 INFO OK: read value = false
2026-02-02 14:30:02,574 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 14:30:02,574 INFO OK: read value = false
2026-02-02 14:30:02,575 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 14:30:02,575 INFO OK: read value = false
2026-02-02 14:30:02,575 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 14:30:02,575 INFO OK: read value = false
2026-02-02 14:30:02,575 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 14:30:02,575 INFO OK: read value = false
2026-02-02 14:30:02,575 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 14:30:02,575 INFO OK: read value = false
2026-02-02 14:30:02,575 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 14:30:02,575 INFO OK: read value = false
2026-02-02 14:30:02,576 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 14:30:02,576 INFO OK: read value = false
2026-02-02 14:30:02,576 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 14:30:02,576 INFO OK: read value = false
2026-02-02 14:30:02,576 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 14:30:02,576 INFO OK: read value = false
2026-02-02 14:30:02,576 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 14:30:02,576 INFO OK: read value = false
2026-02-02 14:30:02,576 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 14:30:02,576 INFO OK: read value = false
2026-02-02 14:30:02,576 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 14:30:02,576 INFO OK: read value = false
2026-02-02 14:30:02,576 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 14:30:02,577 INFO OK: read value = false
2026-02-02 14:30:02,577 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 14:30:02,577 INFO OK: read value = false
2026-02-02 14:30:02,577 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 14:30:02,577 INFO OK: read value = false
2026-02-02 14:30:02,577 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 14:30:02,577 INFO OK: read value = false
2026-02-02 14:30:02,577 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 14:30:02,577 INFO OK: read value = false
2026-02-02 14:30:02,577 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 14:30:02,577 INFO OK: read value = false
2026-02-02 14:30:02,577 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 14:30:02,577 INFO OK: read value = false
2026-02-02 14:30:02,578 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 14:30:02,578 INFO OK: read value = false
2026-02-02 14:30:02,578 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 14:30:02,578 INFO OK: read value = false
2026-02-02 14:30:02,579 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 14:30:02,579 INFO OK: read value = false
2026-02-02 14:30:02,579 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 14:30:02,579 INFO OK: read value = false
2026-02-02 14:30:02,579 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 14:30:02,579 INFO OK: read value = false
2026-02-02 14:30:02,580 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 14:30:02,580 INFO OK: read value = false
2026-02-02 14:30:02,580 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 14:30:02,580 INFO OK: read value = false
2026-02-02 14:30:02,580 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 14:30:02,581 INFO OK: read value = false
2026-02-02 14:30:02,581 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 14:30:02,581 INFO OK: read value = false
2026-02-02 14:30:02,581 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 14:30:02,581 INFO OK: read value = false
2026-02-02 14:30:02,581 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 14:30:02,583 INFO OK: read value = false
2026-02-02 14:30:02,583 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 14:30:02,583 INFO OK: read value = false
2026-02-02 14:30:02,584 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 14:30:02,584 INFO OK: read value = false
2026-02-02 14:30:02,584 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 14:30:02,584 INFO OK: read value = false
2026-02-02 14:30:02,584 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 14:30:02,584 INFO OK: read value = false
2026-02-02 14:30:02,585 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 14:30:02,585 INFO OK: read value = false
2026-02-02 14:30:02,585 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 14:30:02,585 INFO OK: read value = false
2026-02-02 14:30:02,585 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 14:30:02,585 INFO OK: read value = false
2026-02-02 14:30:02,586 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 14:30:02,586 INFO OK: read value = false
2026-02-02 14:30:02,586 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 14:30:02,586 INFO OK: read value = false
2026-02-02 14:30:02,586 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 14:30:02,586 INFO OK: read value = false
2026-02-02 14:30:02,586 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 14:30:02,586 INFO OK: read value = false
2026-02-02 14:30:02,586 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 14:30:02,587 INFO OK: read value = false
2026-02-02 14:30:02,587 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 14:30:02,587 INFO OK: read value = false
2026-02-02 14:30:02,587 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 14:30:02,587 INFO OK: read value = false
2026-02-02 14:30:02,588 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 14:30:02,588 INFO OK: read value = false
2026-02-02 14:30:02,588 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 14:30:02,588 INFO OK: read value = false
2026-02-02 14:30:02,588 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 14:30:02,588 INFO OK: read value = false
2026-02-02 14:30:02,589 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 14:30:02,589 INFO OK: read value = false
2026-02-02 14:30:02,589 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 14:30:02,589 INFO OK: read value = false
2026-02-02 14:30:02,589 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 14:30:02,590 INFO OK: read value = false
2026-02-02 14:30:02,590 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 14:30:02,590 INFO OK: read value = false
2026-02-02 14:30:02,592 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 14:30:02,592 INFO OK: read value = false
2026-02-02 14:30:02,592 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 14:30:02,592 INFO OK: read value = false
2026-02-02 14:30:02,592 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 14:30:02,592 INFO OK: read value = false
2026-02-02 14:30:02,592 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 14:30:02,592 INFO OK: read value = false
2026-02-02 14:30:02,592 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 14:30:02,592 INFO OK: read value = false
2026-02-02 14:30:02,592 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 14:30:02,592 INFO OK: read value = false
2026-02-02 14:30:02,593 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 14:30:02,593 INFO OK: read value = false
2026-02-02 14:30:02,593 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 14:30:02,595 INFO OK: read value = false
2026-02-02 14:30:02,595 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 14:30:02,595 INFO OK: read value = false
2026-02-02 14:30:02,595 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 14:30:02,595 INFO OK: read value = false
2026-02-02 14:30:02,595 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 14:30:02,595 INFO OK: read value = false
2026-02-02 14:30:02,595 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 14:30:02,595 INFO OK: read value = false
2026-02-02 14:30:02,595 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 14:30:02,595 INFO OK: read value = false
2026-02-02 14:30:02,595 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 14:30:02,595 INFO OK: read value = false
2026-02-02 14:30:02,596 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 14:30:02,596 INFO OK: read value = false
2026-02-02 14:30:02,596 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 14:30:02,596 INFO OK: read value = false
2026-02-02 14:30:02,596 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 14:30:02,596 INFO OK: read value = false
2026-02-02 14:30:02,596 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 14:30:02,596 INFO OK: read value = false
2026-02-02 14:30:02,597 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 14:30:02,597 INFO OK: read value = false
2026-02-02 14:30:02,597 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 14:30:02,597 INFO OK: read value = false
2026-02-02 14:30:02,597 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 14:30:02,597 INFO OK: read value = false
2026-02-02 14:30:02,597 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 14:30:02,597 INFO OK: read value = false
2026-02-02 14:30:02,597 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 14:30:02,597 INFO OK: read value = false
2026-02-02 14:30:02,598 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 14:30:02,598 INFO OK: read value = false
2026-02-02 14:30:02,598 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 14:30:02,598 INFO OK: read value = false
2026-02-02 14:30:02,598 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 14:30:02,598 INFO OK: read value = false
2026-02-02 14:30:02,598 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 14:30:02,598 INFO OK: read value = false
2026-02-02 14:30:02,598 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 14:30:02,598 INFO OK: read value = false
2026-02-02 14:30:02,598 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 14:30:02,598 INFO OK: read value = false
2026-02-02 14:30:02,599 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 14:30:02,599 INFO OK: read value = false
2026-02-02 14:30:02,599 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 14:30:02,599 INFO OK: read value = false
2026-02-02 14:30:02,599 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 14:30:02,599 INFO OK: read value = false
2026-02-02 14:30:02,599 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 14:30:02,600 INFO OK: read value = false
2026-02-02 14:30:02,600 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 14:30:02,600 INFO OK: read value = false
2026-02-02 14:30:02,602 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 14:30:02,602 INFO OK: read value = false
2026-02-02 14:30:02,602 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 14:30:02,603 INFO OK: read value = false
2026-02-02 14:30:02,603 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 14:30:02,603 INFO OK: read value = false
2026-02-02 14:30:02,603 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 14:30:02,604 INFO OK: read value = false
2026-02-02 14:30:02,604 INFO [Run 3] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 14:30:02,604 WARNING B8_Degradation: 1 failures - fail
2026-02-02 14:30:02,604 INFO 0.0s remaining ...
2026-02-02 14:30:02,604 INFO [Run 3] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 14:30:02,605 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3
Total Step 190: Success 187 (98.42%), Failed 3 (1.58%),
2026-02-02 14:30:02,605 INFO tgt_gen()
2026-02-02 14:30:02,620 DEBUG [MOCK] Field num: 1
2026-02-02 14:30:02,620 INFO TgtMsg: 1 1
2026-02-02 14:30:02,620 INFO Tgt: 1 @ 1180
2026-02-02 14:30:02,620 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 14:30:02,620 INFO OK: read value = 1
2026-02-02 14:30:02,620 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 14:30:02,620 INFO OK: read value = 1180
2026-02-02 14:30:02,621 INFO Repetitions terminated.
2026-02-02 14:30:02,621 INFO [Report] Custom statistics data registered for PDF generation
2026-02-02 14:30:02,622 INFO ==========================================================================================
2026-02-02 14:30:02,622 INFO FINAL TEST STATISTICS SUMMARY
2026-02-02 14:30:02,623 INFO ==========================================================================================
2026-02-02 14:30:02,623 INFO Total Runs: 3
2026-02-02 14:30:02,624 INFO Successful: 3 (100.0%)
2026-02-02 14:30:02,624 INFO Failed: 0 (0.0%)
2026-02-02 14:30:02,624 INFO B6 Checks: 36 (Pass: 30, Fail: 0, Known: 6)
2026-02-02 14:30:02,624 INFO B8 Checks: 519 (Pass: 513, Fail: 6)
2026-02-02 14:30:02,625 INFO Serial: 0 messages (0 errors, 0 fatal, 0 recycles)
2026-02-02 14:30:02,625 INFO PBIT Timing: avg=0.24s, min=0.23s, max=0.24s, σ=0.00s
2026-02-02 14:30:02,625 INFO ==========================================================================================
2026-02-02 14:30:02,625 INFO Detailed statistics will be available in the PDF report
2026-02-02 14:30:02,626 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_143002_statistics.csv
2026-02-02 14:30:02,632 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_143002_statistics.csv
2026-02-02 14:30:02,634 INFO Statistics exported successfully to JSON: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_143002_statistics.json
2026-02-02 14:30:02,634 INFO Set MAIN_POWER to False
2026-02-02 14:30:02,635 INFO [MOCK] Power OFF
2026-02-02 14:30:02,635 INFO [MOCK] 1553 Interface stopped
2026-02-02 14:30:07,642 INFO Check that MAIN_POWER is equal to 0
2026-02-02 14:30:07,644 INFO OK: read value = False
2026-02-02 14:30:07,644 INFO [MOCK] Serial terminal disconnected
2026-02-02 14:30:07,649 INFO Stop Time: 2026-02-02 14:29:16.101333
2026-02-02 14:30:07,649 INFO Test execution time: 0:00:51.548326