2026-02-02 15:33:39,717 INFO Start Time: 2026-02-02 15:33:39.717098
2026-02-02 15:33:39,717 INFO [MOCK] Serial terminal initialized
2026-02-02 15:33:39,717 INFO [MOCK] Serial terminal connected
2026-02-02 15:33:39,717 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:33:39,820 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:33:39,820 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-02-02 15:33:39,821 INFO [MOCK] Simulating target acquisition: will appear after 7 scan cycles
2026-02-02 15:33:39,821 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:39,884 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:39,946 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:40,009 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:40,072 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:40,135 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:40,194 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:40,258 INFO [MOCK] Target simulated at distance 1180
2026-02-02 15:33:40,258 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts
2026-02-02 15:33:40,258 INFO tgt_gen_alone(): 0
2026-02-02 15:33:40,258 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:33:40,273 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:33:40,273 INFO TgtMsg: 0 0
2026-02-02 15:33:40,273 INFO Tgt: 1 @ 1180
2026-02-02 15:33:40,273 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:33:40,273 INFO OK: read value = 1
2026-02-02 15:33:40,273 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:33:40,274 INFO OK: read value = 1180
2026-02-02 15:33:40,274 INFO [MOCK] Log stopped
2026-02-02 15:33:40,274 INFO Repetition 1 of 3
2026-02-02 15:33:40,274 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:33:40,274 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:33:41,283 INFO Set MAIN_POWER to False
2026-02-02 15:33:41,283 INFO [MOCK] Power OFF
2026-02-02 15:33:41,283 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:33:46,298 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:33:46,298 INFO OK: read value = False
2026-02-02 15:33:50,299 INFO The test operator is required to switch on the target.
2026-02-02 15:33:50,299 INFO Set MAIN_POWER to True
2026-02-02 15:33:50,299 INFO [MOCK] Power ON
2026-02-02 15:33:50,299 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:33:50,299 INFO run_count = 1
2026-02-02 15:33:50,299 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:33:50,299 INFO current_scenario = 'mixed'
2026-02-02 15:33:50,299 INFO _scenario_list = ['normal', 'recycle_fail_3', 'sp_tests_fail']
2026-02-02 15:33:50,299 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:33:50,299 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='normal'
2026-02-02 15:33:50,299 INFO [DEBUG] About to call _log_scenario_info('normal', 1, 3)
2026-02-02 15:33:50,299 INFO
2026-02-02 15:33:50,299 INFO ####################################################################################################
2026-02-02 15:33:50,299 INFO ####################################################################################################
2026-02-02 15:33:50,299 INFO ### RUN 1/3: NORMAL OPERATION
2026-02-02 15:33:50,299 INFO ####################################################################################################
2026-02-02 15:33:50,299 INFO
2026-02-02 15:33:50,299 INFO SCENARIO: normal
2026-02-02 15:33:50,299 INFO DESCRIPTION: All systems operational - no failures
2026-02-02 15:33:50,306 INFO
2026-02-02 15:33:50,306 INFO EXPECTED FAILURES:
2026-02-02 15:33:50,306 INFO (none)
2026-02-02 15:33:50,306 INFO
2026-02-02 15:33:50,307 INFO EXPECTED PASSES:
2026-02-02 15:33:50,307 INFO ✓ All B6 status fields (except pedestal)
2026-02-02 15:33:50,307 INFO ✓ All B8 diagnostic fields
2026-02-02 15:33:50,307 INFO ✓ Target generation
2026-02-02 15:33:50,308 INFO
2026-02-02 15:33:50,308 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present)
2026-02-02 15:33:50,308 INFO
2026-02-02 15:33:50,308 INFO ####################################################################################################
2026-02-02 15:33:50,308 INFO ####################################################################################################
2026-02-02 15:33:50,308 INFO
2026-02-02 15:33:50,309 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:33:50,311 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected)
2026-02-02 15:33:50,311 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1)
2026-02-02 15:33:55,325 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:33:55,325 INFO OK: read value = True
2026-02-02 15:33:55,439 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:33:55,641 INFO [MOCK] BIT report available after 5.3s
2026-02-02 15:33:55,672 INFO BIT report available after 0.2s
2026-02-02 15:33:55,673 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:33:55,673 INFO OK: read value = false
2026-02-02 15:33:55,673 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:33:55,673 WARNING CHECK ERROR: read value = true
2026-02-02 15:33:55,674 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:33:55,674 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:33:55,674 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:33:55,674 INFO OK: read value = false
2026-02-02 15:33:55,675 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:33:55,675 INFO OK: read value = false
2026-02-02 15:33:55,676 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:33:55,676 INFO OK: read value = false
2026-02-02 15:33:55,676 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:33:55,676 INFO OK: read value = false
2026-02-02 15:33:55,677 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:33:55,677 INFO OK: read value = false
2026-02-02 15:33:55,677 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:33:55,677 INFO OK: read value = false
2026-02-02 15:33:55,677 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:33:55,678 INFO OK: read value = false
2026-02-02 15:33:55,678 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:33:55,678 INFO OK: read value = false
2026-02-02 15:33:55,678 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:33:55,678 INFO OK: read value = false
2026-02-02 15:33:55,678 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:33:55,679 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 15:33:55,679 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 15:33:55,680 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 15:33:55,680 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 15:33:55,680 INFO Known failures (HW setup): 2
2026-02-02 15:33:55,680 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 15:33:55,681 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 15:33:55,681 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:33:55,681 INFO OK: read value = false
2026-02-02 15:33:55,681 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:33:55,681 INFO OK: read value = false
2026-02-02 15:33:55,681 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:33:55,682 INFO OK: read value = false
2026-02-02 15:33:55,682 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:33:55,682 INFO OK: read value = false
2026-02-02 15:33:55,682 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:33:55,683 INFO OK: read value = false
2026-02-02 15:33:55,683 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:33:55,683 INFO OK: read value = false
2026-02-02 15:33:55,683 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:33:55,684 INFO OK: read value = false
2026-02-02 15:33:55,684 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:33:55,684 INFO OK: read value = false
2026-02-02 15:33:55,684 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:33:55,685 INFO OK: read value = false
2026-02-02 15:33:55,685 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:33:55,685 WARNING CHECK ERROR: read value = 0
2026-02-02 15:33:55,686 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:33:55,686 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:33:55,686 INFO OK: read value = false
2026-02-02 15:33:55,686 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:33:55,686 INFO OK: read value = false
2026-02-02 15:33:55,687 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:33:55,687 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:33:55,687 INFO OK: read value = false
2026-02-02 15:33:55,687 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:33:55,687 INFO OK: read value = false
2026-02-02 15:33:55,688 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:33:55,688 INFO OK: read value = false
2026-02-02 15:33:55,688 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:33:55,689 INFO OK: read value = false
2026-02-02 15:33:55,689 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:33:55,689 INFO OK: read value = false
2026-02-02 15:33:55,689 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:33:55,689 INFO OK: read value = false
2026-02-02 15:33:55,690 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:33:55,690 INFO OK: read value = false
2026-02-02 15:33:55,690 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:33:55,690 INFO OK: read value = false
2026-02-02 15:33:55,690 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:33:55,690 INFO OK: read value = false
2026-02-02 15:33:55,690 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:33:55,690 INFO OK: read value = false
2026-02-02 15:33:55,690 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:33:55,690 INFO OK: read value = false
2026-02-02 15:33:55,691 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:33:55,691 INFO OK: read value = false
2026-02-02 15:33:55,691 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:33:55,691 INFO OK: read value = false
2026-02-02 15:33:55,691 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:33:55,691 INFO OK: read value = false
2026-02-02 15:33:55,691 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:33:55,691 INFO OK: read value = false
2026-02-02 15:33:55,691 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:33:55,691 INFO OK: read value = false
2026-02-02 15:33:55,691 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:33:55,692 INFO OK: read value = false
2026-02-02 15:33:55,692 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:33:55,692 INFO OK: read value = false
2026-02-02 15:33:55,692 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:33:55,692 INFO OK: read value = false
2026-02-02 15:33:55,692 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:33:55,692 INFO OK: read value = false
2026-02-02 15:33:55,693 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:33:55,693 INFO OK: read value = false
2026-02-02 15:33:55,694 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:33:55,694 INFO OK: read value = false
2026-02-02 15:33:55,694 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:33:55,694 INFO OK: read value = false
2026-02-02 15:33:55,694 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:33:55,695 INFO OK: read value = false
2026-02-02 15:33:55,695 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:33:55,695 INFO OK: read value = false
2026-02-02 15:33:55,695 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:33:55,695 INFO OK: read value = false
2026-02-02 15:33:55,695 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:33:55,695 INFO OK: read value = false
2026-02-02 15:33:55,696 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:33:55,696 INFO OK: read value = false
2026-02-02 15:33:55,696 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:33:55,696 INFO OK: read value = false
2026-02-02 15:33:55,696 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:33:55,696 INFO OK: read value = false
2026-02-02 15:33:55,697 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:33:55,697 INFO OK: read value = false
2026-02-02 15:33:55,697 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:33:55,697 INFO OK: read value = false
2026-02-02 15:33:55,697 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:33:55,697 INFO OK: read value = false
2026-02-02 15:33:55,697 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:33:55,698 INFO OK: read value = false
2026-02-02 15:33:55,698 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:33:55,698 INFO OK: read value = false
2026-02-02 15:33:55,698 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:33:55,698 INFO OK: read value = false
2026-02-02 15:33:55,698 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:33:55,698 INFO OK: read value = false
2026-02-02 15:33:55,699 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:33:55,699 INFO OK: read value = false
2026-02-02 15:33:55,699 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:33:55,699 INFO OK: read value = false
2026-02-02 15:33:55,699 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:33:55,700 INFO OK: read value = false
2026-02-02 15:33:55,700 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:33:55,700 INFO OK: read value = false
2026-02-02 15:33:55,700 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:33:55,700 INFO OK: read value = false
2026-02-02 15:33:55,700 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:33:55,700 INFO OK: read value = false
2026-02-02 15:33:55,700 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:33:55,700 INFO OK: read value = false
2026-02-02 15:33:55,701 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:33:55,701 INFO OK: read value = false
2026-02-02 15:33:55,701 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:33:55,701 INFO OK: read value = false
2026-02-02 15:33:55,701 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:33:55,701 INFO OK: read value = false
2026-02-02 15:33:55,701 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:33:55,701 INFO OK: read value = false
2026-02-02 15:33:55,701 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:33:55,701 INFO OK: read value = false
2026-02-02 15:33:55,701 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:33:55,702 INFO OK: read value = false
2026-02-02 15:33:55,702 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:33:55,702 INFO OK: read value = false
2026-02-02 15:33:55,702 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:33:55,702 INFO OK: read value = false
2026-02-02 15:33:55,702 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:33:55,702 INFO OK: read value = false
2026-02-02 15:33:55,702 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:33:55,703 INFO OK: read value = false
2026-02-02 15:33:55,703 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:33:55,703 INFO OK: read value = false
2026-02-02 15:33:55,703 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:33:55,703 INFO OK: read value = false
2026-02-02 15:33:55,703 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:33:55,703 INFO OK: read value = false
2026-02-02 15:33:55,703 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:33:55,703 INFO OK: read value = false
2026-02-02 15:33:55,703 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:33:55,703 INFO OK: read value = false
2026-02-02 15:33:55,704 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:33:55,704 INFO OK: read value = false
2026-02-02 15:33:55,704 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:33:55,704 INFO OK: read value = false
2026-02-02 15:33:55,704 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:33:55,704 INFO OK: read value = false
2026-02-02 15:33:55,704 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:33:55,704 INFO OK: read value = false
2026-02-02 15:33:55,704 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:33:55,704 INFO OK: read value = false
2026-02-02 15:33:55,704 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:33:55,705 INFO OK: read value = false
2026-02-02 15:33:55,705 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:33:55,705 INFO OK: read value = false
2026-02-02 15:33:55,705 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:33:55,705 INFO OK: read value = false
2026-02-02 15:33:55,705 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:33:55,705 INFO OK: read value = false
2026-02-02 15:33:55,705 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:33:55,705 INFO OK: read value = false
2026-02-02 15:33:55,706 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:33:55,706 INFO OK: read value = false
2026-02-02 15:33:55,706 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:33:55,707 INFO OK: read value = false
2026-02-02 15:33:55,707 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:33:55,707 INFO OK: read value = false
2026-02-02 15:33:55,707 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:33:55,708 INFO OK: read value = false
2026-02-02 15:33:55,708 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:33:55,708 INFO OK: read value = false
2026-02-02 15:33:55,709 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:33:55,709 INFO OK: read value = false
2026-02-02 15:33:55,709 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:33:55,710 INFO OK: read value = false
2026-02-02 15:33:55,710 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:33:55,710 INFO OK: read value = false
2026-02-02 15:33:55,710 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:33:55,711 INFO OK: read value = false
2026-02-02 15:33:55,711 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:33:55,711 INFO OK: read value = false
2026-02-02 15:33:55,712 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:33:55,712 INFO OK: read value = false
2026-02-02 15:33:55,712 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:33:55,713 INFO OK: read value = false
2026-02-02 15:33:55,713 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:33:55,713 INFO OK: read value = false
2026-02-02 15:33:55,713 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:33:55,713 INFO OK: read value = false
2026-02-02 15:33:55,714 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:33:55,714 INFO OK: read value = false
2026-02-02 15:33:55,714 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:33:55,715 INFO OK: read value = false
2026-02-02 15:33:55,715 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:33:55,715 INFO OK: read value = false
2026-02-02 15:33:55,715 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:33:55,716 INFO OK: read value = false
2026-02-02 15:33:55,716 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:33:55,716 INFO OK: read value = false
2026-02-02 15:33:55,716 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:33:55,716 INFO OK: read value = false
2026-02-02 15:33:55,717 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:33:55,717 INFO OK: read value = false
2026-02-02 15:33:55,718 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:33:55,718 INFO OK: read value = false
2026-02-02 15:33:55,718 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:33:55,718 INFO OK: read value = false
2026-02-02 15:33:55,718 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:33:55,719 INFO OK: read value = false
2026-02-02 15:33:55,728 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:33:55,728 INFO OK: read value = false
2026-02-02 15:33:55,728 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:33:55,728 INFO OK: read value = false
2026-02-02 15:33:55,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:33:55,729 INFO OK: read value = false
2026-02-02 15:33:55,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:33:55,729 INFO OK: read value = false
2026-02-02 15:33:55,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:33:55,729 INFO OK: read value = false
2026-02-02 15:33:55,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:33:55,729 INFO OK: read value = false
2026-02-02 15:33:55,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:33:55,730 INFO OK: read value = false
2026-02-02 15:33:55,730 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:33:55,730 INFO OK: read value = false
2026-02-02 15:33:55,730 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:33:55,730 INFO OK: read value = false
2026-02-02 15:33:55,730 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:33:55,730 INFO OK: read value = false
2026-02-02 15:33:55,730 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:33:55,730 INFO OK: read value = false
2026-02-02 15:33:55,730 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:33:55,730 INFO OK: read value = false
2026-02-02 15:33:55,731 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:33:55,731 INFO OK: read value = false
2026-02-02 15:33:55,731 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:33:55,731 INFO OK: read value = false
2026-02-02 15:33:55,731 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:33:55,731 INFO OK: read value = false
2026-02-02 15:33:55,731 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:33:55,731 INFO OK: read value = false
2026-02-02 15:33:55,731 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:33:55,731 INFO OK: read value = false
2026-02-02 15:33:55,732 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:33:55,732 INFO OK: read value = false
2026-02-02 15:33:55,732 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:33:55,732 INFO OK: read value = false
2026-02-02 15:33:55,732 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:33:55,732 INFO OK: read value = false
2026-02-02 15:33:55,732 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:33:55,732 INFO OK: read value = false
2026-02-02 15:33:55,732 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:33:55,732 INFO OK: read value = false
2026-02-02 15:33:55,732 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:33:55,732 INFO OK: read value = false
2026-02-02 15:33:55,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:33:55,733 INFO OK: read value = false
2026-02-02 15:33:55,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:33:55,733 INFO OK: read value = false
2026-02-02 15:33:55,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:33:55,733 INFO OK: read value = false
2026-02-02 15:33:55,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:33:55,733 INFO OK: read value = false
2026-02-02 15:33:55,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:33:55,734 INFO OK: read value = false
2026-02-02 15:33:55,734 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:33:55,734 INFO OK: read value = false
2026-02-02 15:33:55,734 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:33:55,734 INFO OK: read value = false
2026-02-02 15:33:55,734 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:33:55,734 INFO OK: read value = false
2026-02-02 15:33:55,734 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:33:55,734 INFO OK: read value = false
2026-02-02 15:33:55,734 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:33:55,734 INFO OK: read value = false
2026-02-02 15:33:55,734 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:33:55,735 INFO OK: read value = false
2026-02-02 15:33:55,735 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:33:55,735 INFO OK: read value = false
2026-02-02 15:33:55,735 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:33:55,735 INFO OK: read value = false
2026-02-02 15:33:55,735 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:33:55,735 INFO OK: read value = false
2026-02-02 15:33:55,735 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:33:55,736 INFO OK: read value = false
2026-02-02 15:33:55,736 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:33:55,736 INFO OK: read value = false
2026-02-02 15:33:55,736 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:33:55,736 INFO OK: read value = false
2026-02-02 15:33:55,736 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:33:55,738 INFO OK: read value = false
2026-02-02 15:33:55,739 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:33:55,739 INFO OK: read value = false
2026-02-02 15:33:55,739 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:33:55,739 INFO OK: read value = false
2026-02-02 15:33:55,739 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:33:55,739 INFO OK: read value = false
2026-02-02 15:33:55,739 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:33:55,739 INFO OK: read value = false
2026-02-02 15:33:55,739 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:33:55,740 INFO OK: read value = false
2026-02-02 15:33:55,740 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:33:55,741 INFO OK: read value = false
2026-02-02 15:33:55,741 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:33:55,741 INFO OK: read value = false
2026-02-02 15:33:55,741 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:33:55,741 INFO OK: read value = false
2026-02-02 15:33:55,741 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:33:55,741 INFO OK: read value = false
2026-02-02 15:33:55,742 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:33:55,742 INFO OK: read value = false
2026-02-02 15:33:55,742 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:33:55,742 INFO OK: read value = false
2026-02-02 15:33:55,743 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:33:55,743 INFO OK: read value = false
2026-02-02 15:33:55,743 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:33:55,744 INFO OK: read value = false
2026-02-02 15:33:55,744 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:33:55,744 INFO OK: read value = false
2026-02-02 15:33:55,744 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:33:55,744 INFO OK: read value = false
2026-02-02 15:33:55,745 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:33:55,745 INFO OK: read value = false
2026-02-02 15:33:55,745 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:33:55,745 INFO OK: read value = false
2026-02-02 15:33:55,745 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:33:55,745 INFO OK: read value = false
2026-02-02 15:33:55,745 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:33:55,745 INFO OK: read value = false
2026-02-02 15:33:55,745 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:33:55,745 INFO OK: read value = false
2026-02-02 15:33:55,746 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:33:55,746 INFO OK: read value = false
2026-02-02 15:33:55,746 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:33:55,746 INFO OK: read value = false
2026-02-02 15:33:55,746 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:33:55,746 INFO OK: read value = false
2026-02-02 15:33:55,747 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:33:55,747 INFO OK: read value = false
2026-02-02 15:33:55,747 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:33:55,748 INFO OK: read value = false
2026-02-02 15:33:55,748 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:33:55,748 INFO OK: read value = false
2026-02-02 15:33:55,748 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:33:55,748 INFO OK: read value = false
2026-02-02 15:33:55,748 INFO [Run 1] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:33:55,749 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:33:55,749 INFO 0.0s remaining ...
2026-02-02 15:33:55,749 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 15:33:55,749 INFO Target Detection Test
2026-02-02 15:33:55,750 INFO [Run 1] Starting target detection test (timeout: 5.0s)
2026-02-02 15:33:55,750 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:33:55,774 INFO TgtMsg: 1 1
2026-02-02 15:33:55,774 INFO Tgt: 1 @ 1180
2026-02-02 15:33:55,774 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:33:55,774 INFO OK: read value = 1
2026-02-02 15:33:55,774 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:33:55,775 INFO OK: read value = 1180
2026-02-02 15:33:55,779 INFO Target detected successfully in 0.03s
2026-02-02 15:33:55,779 INFO [Run 1] Target DETECTED in 0.03s
2026-02-02 15:33:55,779 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3
Total Step 194: Success 191 (98.45%), Failed 3 (1.55%),
2026-02-02 15:33:55,779 INFO Repetition 2 of 3
2026-02-02 15:33:55,780 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:33:55,780 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:33:56,785 INFO Set MAIN_POWER to False
2026-02-02 15:33:56,785 INFO [MOCK] Power OFF
2026-02-02 15:33:56,785 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:34:01,793 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:34:01,793 INFO OK: read value = False
2026-02-02 15:34:05,796 INFO The test operator is required to switch on the target.
2026-02-02 15:34:05,796 INFO Set MAIN_POWER to True
2026-02-02 15:34:05,796 INFO [MOCK] Power ON
2026-02-02 15:34:05,796 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:34:05,796 INFO run_count = 2
2026-02-02 15:34:05,796 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:34:05,796 INFO current_scenario = 'mixed'
2026-02-02 15:34:05,796 INFO _scenario_list = ['normal', 'recycle_fail_3', 'sp_tests_fail']
2026-02-02 15:34:05,796 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:34:05,796 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='recycle_fail_3'
2026-02-02 15:34:05,796 INFO [DEBUG] About to call _log_scenario_info('recycle_fail_3', 2, 3)
2026-02-02 15:34:05,796 INFO
2026-02-02 15:34:05,796 INFO ####################################################################################################
2026-02-02 15:34:05,796 INFO ####################################################################################################
2026-02-02 15:34:05,796 INFO ### RUN 2/3: RECYCLE NO RECOVERY (3+ CYCLES)
2026-02-02 15:34:05,796 INFO ####################################################################################################
2026-02-02 15:34:05,796 INFO
2026-02-02 15:34:05,796 INFO SCENARIO: recycle_fail_3
2026-02-02 15:34:05,796 INFO DESCRIPTION: Processor fails and NEVER recovers despite 3 RECYCLE events
2026-02-02 15:34:05,796 INFO
2026-02-02 15:34:05,796 INFO EXPECTED FAILURES:
2026-02-02 15:34:05,796 INFO ✗ Persistent: processor_status = FAIL
2026-02-02 15:34:05,796 INFO ✗ Serial: 3x RECYCLE events detected
2026-02-02 15:34:05,796 INFO ✗ No recovery achieved
2026-02-02 15:34:05,796 INFO
2026-02-02 15:34:05,796 INFO EXPECTED PASSES:
2026-02-02 15:34:05,796 INFO ✓ None - system remains in failed state
2026-02-02 15:34:05,804 INFO
2026-02-02 15:34:05,804 INFO NOTES: Simulates hard failure requiring power cycle. Test should fail and report persistent failure
2026-02-02 15:34:05,804 INFO
2026-02-02 15:34:05,804 INFO ####################################################################################################
2026-02-02 15:34:05,805 INFO ####################################################################################################
2026-02-02 15:34:05,805 INFO
2026-02-02 15:34:05,805 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:34:05,805 INFO [MOCK APPLY] ⚠ RECYCLE scenario enabled: NO recovery (persistent failure)
2026-02-02 15:34:05,805 INFO [MOCK RECYCLE] Initial processor failure detected
2026-02-02 15:34:06,315 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:34:06,315 INFO [MOCK RECYCLE] RECYCLE 1/3 - NO RECOVERY
2026-02-02 15:34:06,816 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:34:06,816 INFO [MOCK RECYCLE] RECYCLE 2/3 - NO RECOVERY
2026-02-02 15:34:07,331 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:34:07,331 INFO [MOCK RECYCLE] RECYCLE 3/3 - NO RECOVERY
2026-02-02 15:34:07,331 WARNING [MOCK RECYCLE] System did NOT recover after 3 RECYCLEs - requires power cycle
2026-02-02 15:34:07,331 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-02-02 15:34:12,343 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:34:12,343 INFO OK: read value = True
2026-02-02 15:34:12,453 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:34:12,658 INFO [MOCK] BIT report available after 6.9s
2026-02-02 15:34:12,688 INFO BIT report available after 0.2s
2026-02-02 15:34:12,689 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:34:12,689 INFO OK: read value = false
2026-02-02 15:34:12,690 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:34:12,690 WARNING CHECK ERROR: read value = true
2026-02-02 15:34:12,690 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:34:12,691 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:34:12,691 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:34:12,691 INFO OK: read value = false
2026-02-02 15:34:12,691 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:34:12,692 INFO OK: read value = false
2026-02-02 15:34:12,692 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:34:12,692 WARNING CHECK ERROR: read value = true
2026-02-02 15:34:12,693 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:34:12,693 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:34:12,693 INFO OK: read value = false
2026-02-02 15:34:12,694 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:34:12,694 INFO OK: read value = false
2026-02-02 15:34:12,694 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:34:12,694 INFO OK: read value = false
2026-02-02 15:34:12,695 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:34:12,695 INFO OK: read value = false
2026-02-02 15:34:12,695 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:34:12,695 INFO OK: read value = false
2026-02-02 15:34:12,696 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:34:12,696 INFO OK: read value = false
2026-02-02 15:34:12,696 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:34:12,696 WARNING CHECK ERROR: read value = RDR_FAIL
2026-02-02 15:34:12,696 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL
2026-02-02 15:34:12,697 WARNING Radar fail status: REAL failure (caused by: status, status)
2026-02-02 15:34:12,697 INFO [Run 2] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known
2026-02-02 15:34:12,697 INFO Known failures (HW setup): 1
2026-02-02 15:34:12,697 WARNING Real failures: status, status
2026-02-02 15:34:12,697 INFO
Drill-down: Verifying all 173 B8 diagnostic fields...
2026-02-02 15:34:12,697 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:34:12,698 INFO OK: read value = false
2026-02-02 15:34:12,698 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:34:12,698 INFO OK: read value = false
2026-02-02 15:34:12,698 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:34:12,698 INFO OK: read value = false
2026-02-02 15:34:12,698 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:34:12,698 INFO OK: read value = false
2026-02-02 15:34:12,699 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:34:12,699 INFO OK: read value = false
2026-02-02 15:34:12,699 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:34:12,699 INFO OK: read value = false
2026-02-02 15:34:12,699 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:34:12,699 INFO OK: read value = false
2026-02-02 15:34:12,699 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:34:12,699 INFO OK: read value = false
2026-02-02 15:34:12,699 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:34:12,700 INFO OK: read value = false
2026-02-02 15:34:12,700 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:34:12,700 WARNING CHECK ERROR: read value = 0
2026-02-02 15:34:12,700 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:34:12,700 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:34:12,700 INFO OK: read value = false
2026-02-02 15:34:12,701 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:34:12,701 INFO OK: read value = false
2026-02-02 15:34:12,701 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:34:12,701 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:34:12,701 INFO OK: read value = false
2026-02-02 15:34:12,701 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:34:12,702 INFO OK: read value = false
2026-02-02 15:34:12,702 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:34:12,702 INFO OK: read value = false
2026-02-02 15:34:12,702 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:34:12,702 INFO OK: read value = false
2026-02-02 15:34:12,702 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:34:12,702 INFO OK: read value = false
2026-02-02 15:34:12,702 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:34:12,702 INFO OK: read value = false
2026-02-02 15:34:12,702 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:34:12,702 INFO OK: read value = false
2026-02-02 15:34:12,702 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:34:12,702 INFO OK: read value = false
2026-02-02 15:34:12,702 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:34:12,703 INFO OK: read value = false
2026-02-02 15:34:12,704 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:34:12,704 INFO OK: read value = false
2026-02-02 15:34:12,704 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:34:12,704 INFO OK: read value = false
2026-02-02 15:34:12,704 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:34:12,705 INFO OK: read value = false
2026-02-02 15:34:12,705 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:34:12,705 INFO OK: read value = false
2026-02-02 15:34:12,706 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:34:12,706 INFO OK: read value = false
2026-02-02 15:34:12,706 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:34:12,706 INFO OK: read value = false
2026-02-02 15:34:12,708 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:34:12,708 INFO OK: read value = false
2026-02-02 15:34:12,708 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:34:12,709 INFO OK: read value = false
2026-02-02 15:34:12,709 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:34:12,709 INFO OK: read value = false
2026-02-02 15:34:12,709 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:34:12,709 INFO OK: read value = false
2026-02-02 15:34:12,709 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:34:12,709 INFO OK: read value = false
2026-02-02 15:34:12,709 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:34:12,710 INFO OK: read value = false
2026-02-02 15:34:12,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:34:12,710 INFO OK: read value = false
2026-02-02 15:34:12,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:34:12,710 INFO OK: read value = false
2026-02-02 15:34:12,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:34:12,710 INFO OK: read value = false
2026-02-02 15:34:12,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:34:12,710 INFO OK: read value = false
2026-02-02 15:34:12,711 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:34:12,711 INFO OK: read value = false
2026-02-02 15:34:12,711 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:34:12,711 INFO OK: read value = false
2026-02-02 15:34:12,711 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:34:12,711 INFO OK: read value = false
2026-02-02 15:34:12,711 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:34:12,711 INFO OK: read value = false
2026-02-02 15:34:12,711 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:34:12,711 INFO OK: read value = false
2026-02-02 15:34:12,711 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:34:12,712 INFO OK: read value = false
2026-02-02 15:34:12,712 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:34:12,712 INFO OK: read value = false
2026-02-02 15:34:12,713 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:34:12,713 INFO OK: read value = false
2026-02-02 15:34:12,713 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:34:12,713 INFO OK: read value = false
2026-02-02 15:34:12,715 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:34:12,715 INFO OK: read value = false
2026-02-02 15:34:12,715 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:34:12,715 INFO OK: read value = false
2026-02-02 15:34:12,715 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:34:12,715 INFO OK: read value = false
2026-02-02 15:34:12,715 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:34:12,715 INFO OK: read value = false
2026-02-02 15:34:12,715 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:34:12,715 INFO OK: read value = false
2026-02-02 15:34:12,717 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:34:12,717 INFO OK: read value = false
2026-02-02 15:34:12,717 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:34:12,717 INFO OK: read value = false
2026-02-02 15:34:12,717 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:34:12,717 INFO OK: read value = false
2026-02-02 15:34:12,717 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:34:12,717 INFO OK: read value = false
2026-02-02 15:34:12,717 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:34:12,717 INFO OK: read value = false
2026-02-02 15:34:12,718 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:34:12,718 INFO OK: read value = false
2026-02-02 15:34:12,718 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:34:12,718 INFO OK: read value = false
2026-02-02 15:34:12,718 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:34:12,718 INFO OK: read value = false
2026-02-02 15:34:12,718 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:34:12,718 INFO OK: read value = false
2026-02-02 15:34:12,718 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:34:12,719 INFO OK: read value = false
2026-02-02 15:34:12,719 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:34:12,719 INFO OK: read value = false
2026-02-02 15:34:12,719 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:34:12,719 INFO OK: read value = false
2026-02-02 15:34:12,719 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:34:12,720 INFO OK: read value = false
2026-02-02 15:34:12,720 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:34:12,720 INFO OK: read value = false
2026-02-02 15:34:12,720 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:34:12,720 INFO OK: read value = false
2026-02-02 15:34:12,720 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:34:12,721 INFO OK: read value = false
2026-02-02 15:34:12,721 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:34:12,721 INFO OK: read value = false
2026-02-02 15:34:12,721 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:34:12,721 INFO OK: read value = false
2026-02-02 15:34:12,721 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:34:12,721 INFO OK: read value = false
2026-02-02 15:34:12,721 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:34:12,721 INFO OK: read value = false
2026-02-02 15:34:12,721 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:34:12,721 INFO OK: read value = false
2026-02-02 15:34:12,722 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:34:12,722 INFO OK: read value = false
2026-02-02 15:34:12,722 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:34:12,722 INFO OK: read value = false
2026-02-02 15:34:12,722 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:34:12,722 INFO OK: read value = false
2026-02-02 15:34:12,722 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:34:12,722 INFO OK: read value = false
2026-02-02 15:34:12,722 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:34:12,722 INFO OK: read value = false
2026-02-02 15:34:12,722 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:34:12,722 INFO OK: read value = false
2026-02-02 15:34:12,723 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:34:12,723 INFO OK: read value = false
2026-02-02 15:34:12,723 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:34:12,723 INFO OK: read value = false
2026-02-02 15:34:12,723 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:34:12,723 INFO OK: read value = false
2026-02-02 15:34:12,723 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:34:12,723 INFO OK: read value = false
2026-02-02 15:34:12,723 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:34:12,723 INFO OK: read value = false
2026-02-02 15:34:12,723 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:34:12,723 INFO OK: read value = false
2026-02-02 15:34:12,724 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:34:12,724 INFO OK: read value = false
2026-02-02 15:34:12,724 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:34:12,724 INFO OK: read value = false
2026-02-02 15:34:12,724 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:34:12,724 INFO OK: read value = false
2026-02-02 15:34:12,724 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:34:12,724 INFO OK: read value = false
2026-02-02 15:34:12,724 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:34:12,724 INFO OK: read value = false
2026-02-02 15:34:12,724 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:34:12,724 INFO OK: read value = false
2026-02-02 15:34:12,724 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:34:12,724 INFO OK: read value = false
2026-02-02 15:34:12,725 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:34:12,725 INFO OK: read value = false
2026-02-02 15:34:12,725 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:34:12,725 INFO OK: read value = false
2026-02-02 15:34:12,725 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:34:12,725 INFO OK: read value = false
2026-02-02 15:34:12,725 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:34:12,725 INFO OK: read value = false
2026-02-02 15:34:12,727 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:34:12,727 INFO OK: read value = false
2026-02-02 15:34:12,727 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:34:12,727 INFO OK: read value = false
2026-02-02 15:34:12,727 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:34:12,727 INFO OK: read value = false
2026-02-02 15:34:12,727 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:34:12,727 INFO OK: read value = false
2026-02-02 15:34:12,727 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:34:12,727 INFO OK: read value = false
2026-02-02 15:34:12,728 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:34:12,728 INFO OK: read value = false
2026-02-02 15:34:12,728 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:34:12,728 INFO OK: read value = false
2026-02-02 15:34:12,728 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:34:12,728 INFO OK: read value = false
2026-02-02 15:34:12,728 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:34:12,729 INFO OK: read value = false
2026-02-02 15:34:12,729 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:34:12,729 INFO OK: read value = false
2026-02-02 15:34:12,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:34:12,729 INFO OK: read value = false
2026-02-02 15:34:12,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:34:12,729 INFO OK: read value = false
2026-02-02 15:34:12,729 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:34:12,730 INFO OK: read value = false
2026-02-02 15:34:12,730 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:34:12,730 INFO OK: read value = false
2026-02-02 15:34:12,730 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:34:12,730 INFO OK: read value = false
2026-02-02 15:34:12,730 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:34:12,731 INFO OK: read value = false
2026-02-02 15:34:12,731 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:34:12,731 INFO OK: read value = false
2026-02-02 15:34:12,731 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:34:12,731 INFO OK: read value = false
2026-02-02 15:34:12,731 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:34:12,732 INFO OK: read value = false
2026-02-02 15:34:12,732 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:34:12,732 INFO OK: read value = false
2026-02-02 15:34:12,732 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:34:12,732 INFO OK: read value = false
2026-02-02 15:34:12,732 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:34:12,732 INFO OK: read value = false
2026-02-02 15:34:12,733 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:34:12,733 INFO OK: read value = false
2026-02-02 15:34:12,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:34:12,733 INFO OK: read value = false
2026-02-02 15:34:12,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:34:12,733 INFO OK: read value = false
2026-02-02 15:34:12,733 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:34:12,733 INFO OK: read value = false
2026-02-02 15:34:12,735 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:34:12,735 INFO OK: read value = false
2026-02-02 15:34:12,735 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:34:12,735 INFO OK: read value = false
2026-02-02 15:34:12,735 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:34:12,735 INFO OK: read value = false
2026-02-02 15:34:12,735 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:34:12,736 INFO OK: read value = false
2026-02-02 15:34:12,736 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:34:12,736 INFO OK: read value = false
2026-02-02 15:34:12,736 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:34:12,736 INFO OK: read value = false
2026-02-02 15:34:12,736 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:34:12,737 INFO OK: read value = false
2026-02-02 15:34:12,737 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:34:12,737 INFO OK: read value = false
2026-02-02 15:34:12,737 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:34:12,737 INFO OK: read value = false
2026-02-02 15:34:12,738 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:34:12,738 INFO OK: read value = false
2026-02-02 15:34:12,738 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:34:12,738 INFO OK: read value = false
2026-02-02 15:34:12,738 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:34:12,738 INFO OK: read value = false
2026-02-02 15:34:12,738 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:34:12,738 INFO OK: read value = false
2026-02-02 15:34:12,739 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:34:12,739 INFO OK: read value = false
2026-02-02 15:34:12,739 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:34:12,739 INFO OK: read value = false
2026-02-02 15:34:12,740 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:34:12,740 INFO OK: read value = false
2026-02-02 15:34:12,740 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:34:12,740 INFO OK: read value = false
2026-02-02 15:34:12,740 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:34:12,740 INFO OK: read value = false
2026-02-02 15:34:12,741 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:34:12,741 INFO OK: read value = false
2026-02-02 15:34:12,741 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:34:12,741 INFO OK: read value = false
2026-02-02 15:34:12,741 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:34:12,741 INFO OK: read value = false
2026-02-02 15:34:12,741 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:34:12,742 INFO OK: read value = false
2026-02-02 15:34:12,742 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:34:12,742 INFO OK: read value = false
2026-02-02 15:34:12,742 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:34:12,743 INFO OK: read value = false
2026-02-02 15:34:12,743 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:34:12,744 INFO OK: read value = false
2026-02-02 15:34:12,744 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:34:12,744 INFO OK: read value = false
2026-02-02 15:34:12,744 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:34:12,745 INFO OK: read value = false
2026-02-02 15:34:12,745 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:34:12,745 INFO OK: read value = false
2026-02-02 15:34:12,745 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:34:12,745 INFO OK: read value = false
2026-02-02 15:34:12,746 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:34:12,746 INFO OK: read value = false
2026-02-02 15:34:12,747 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:34:12,747 INFO OK: read value = false
2026-02-02 15:34:12,747 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:34:12,748 INFO OK: read value = false
2026-02-02 15:34:12,748 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:34:12,748 INFO OK: read value = false
2026-02-02 15:34:12,749 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:34:12,749 INFO OK: read value = false
2026-02-02 15:34:12,749 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:34:12,750 INFO OK: read value = false
2026-02-02 15:34:12,750 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:34:12,751 INFO OK: read value = false
2026-02-02 15:34:12,751 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:34:12,752 INFO OK: read value = false
2026-02-02 15:34:12,752 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:34:12,752 INFO OK: read value = false
2026-02-02 15:34:12,753 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:34:12,753 INFO OK: read value = false
2026-02-02 15:34:12,753 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:34:12,754 INFO OK: read value = false
2026-02-02 15:34:12,754 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:34:12,754 INFO OK: read value = false
2026-02-02 15:34:12,754 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:34:12,755 INFO OK: read value = false
2026-02-02 15:34:12,755 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:34:12,755 INFO OK: read value = false
2026-02-02 15:34:12,755 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:34:12,756 INFO OK: read value = false
2026-02-02 15:34:12,756 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:34:12,756 INFO OK: read value = false
2026-02-02 15:34:12,756 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:34:12,757 INFO OK: read value = false
2026-02-02 15:34:12,757 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:34:12,757 INFO OK: read value = false
2026-02-02 15:34:12,757 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:34:12,758 INFO OK: read value = false
2026-02-02 15:34:12,758 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:34:12,758 INFO OK: read value = false
2026-02-02 15:34:12,759 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:34:12,759 INFO OK: read value = false
2026-02-02 15:34:12,759 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:34:12,760 INFO OK: read value = false
2026-02-02 15:34:12,760 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:34:12,760 INFO OK: read value = false
2026-02-02 15:34:12,760 INFO [Run 2] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:34:12,761 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:34:12,761 INFO 0.0s remaining ...
2026-02-02 15:34:12,761 INFO [Run 2] Serial: 3 total, 0 errors, 3 fatal, 3 recycles
2026-02-02 15:34:12,761 INFO Target Detection Test
2026-02-02 15:34:12,762 INFO [Run 2] Starting target detection test (timeout: 5.0s)
2026-02-02 15:34:12,762 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:34:12,781 DEBUG [MOCK] Field num: 1
2026-02-02 15:34:12,781 INFO TgtMsg: 2 2
2026-02-02 15:34:12,781 INFO Tgt: 1 @ 1180
2026-02-02 15:34:12,781 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:34:12,781 DEBUG [MOCK] Field num: 1
2026-02-02 15:34:12,781 INFO OK: read value = 1
2026-02-02 15:34:12,781 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:34:12,781 INFO OK: read value = 1180
2026-02-02 15:34:12,782 INFO Target detected successfully in 0.02s
2026-02-02 15:34:12,782 INFO [Run 2] Target DETECTED in 0.02s
2026-02-02 15:34:12,782 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3
Total Step 192: Success 188 (97.92%), Failed 4 (2.08%),
2026-02-02 15:34:12,782 INFO Repetition 3 of 3
2026-02-02 15:34:12,782 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:34:12,782 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:34:13,788 INFO Set MAIN_POWER to False
2026-02-02 15:34:13,788 INFO [MOCK] Power OFF
2026-02-02 15:34:13,788 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:34:18,796 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:34:18,796 INFO OK: read value = False
2026-02-02 15:34:22,808 INFO The test operator is required to switch on the target.
2026-02-02 15:34:22,808 INFO Set MAIN_POWER to True
2026-02-02 15:34:22,808 INFO [MOCK] Power ON
2026-02-02 15:34:22,808 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:34:22,808 INFO run_count = 3
2026-02-02 15:34:22,810 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:34:22,810 INFO current_scenario = 'mixed'
2026-02-02 15:34:22,810 INFO _scenario_list = ['normal', 'recycle_fail_3', 'sp_tests_fail']
2026-02-02 15:34:22,810 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:34:22,810 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='sp_tests_fail'
2026-02-02 15:34:22,810 INFO [DEBUG] About to call _log_scenario_info('sp_tests_fail', 3, 3)
2026-02-02 15:34:22,810 INFO
2026-02-02 15:34:22,810 INFO ####################################################################################################
2026-02-02 15:34:22,810 INFO ####################################################################################################
2026-02-02 15:34:22,810 INFO ### RUN 3/3: SIGNAL PROCESSOR TEST FAILURES
2026-02-02 15:34:22,810 INFO ####################################################################################################
2026-02-02 15:34:22,810 INFO
2026-02-02 15:34:22,810 INFO SCENARIO: sp_tests_fail
2026-02-02 15:34:22,810 INFO DESCRIPTION: Individual SP tests fail (SP1, SP2, SP3)
2026-02-02 15:34:22,810 INFO
2026-02-02 15:34:22,810 INFO EXPECTED FAILURES:
2026-02-02 15:34:22,810 INFO ✗ B8: test_sp1_timer1_up = FAIL
2026-02-02 15:34:22,810 INFO ✗ B8: test_sp2_timer_dma_pxc_if = FAIL
2026-02-02 15:34:22,810 INFO ✗ B8: test_sp3_timer_internal = FAIL
2026-02-02 15:34:22,810 INFO
2026-02-02 15:34:22,810 INFO EXPECTED PASSES:
2026-02-02 15:34:22,810 INFO ✓ B6 status fields (except processor)
2026-02-02 15:34:22,810 INFO ✓ Other B8 tests
2026-02-02 15:34:22,810 INFO
2026-02-02 15:34:22,814 INFO NOTES: Demonstrates granular test failure analysis - specific SP component failures
2026-02-02 15:34:22,814 INFO
2026-02-02 15:34:22,815 INFO ####################################################################################################
2026-02-02 15:34:22,816 INFO ####################################################################################################
2026-02-02 15:34:22,816 INFO
2026-02-02 15:34:22,816 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:34:22,816 INFO [MOCK APPLY] ✗ Setting processor_status = FAIL
2026-02-02 15:34:22,816 INFO [MOCK APPLY] ✗ B8 failures: SP1 (timer1_up), SP2 (timer_dma_pxc_if), SP3 (timer_internal)
2026-02-02 15:34:22,817 INFO [MOCK RECYCLE] Initial processor failure detected
2026-02-02 15:34:23,318 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:34:23,318 INFO [MOCK RECYCLE] RECYCLE 1/3 - NO RECOVERY
2026-02-02 15:34:23,819 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:34:23,819 INFO [MOCK RECYCLE] RECYCLE 2/3 - NO RECOVERY
2026-02-02 15:34:24,333 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:34:24,333 INFO [MOCK RECYCLE] RECYCLE 3/3 - NO RECOVERY
2026-02-02 15:34:24,333 WARNING [MOCK RECYCLE] System did NOT recover after 3 RECYCLEs - requires power cycle
2026-02-02 15:34:24,333 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3)
2026-02-02 15:34:29,334 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:34:29,334 INFO OK: read value = True
2026-02-02 15:34:29,444 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:34:29,654 INFO [MOCK] BIT report available after 6.8s
2026-02-02 15:34:29,685 INFO BIT report available after 0.2s
2026-02-02 15:34:29,685 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:34:29,685 INFO OK: read value = false
2026-02-02 15:34:29,685 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:34:29,685 WARNING CHECK ERROR: read value = true
2026-02-02 15:34:29,686 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:34:29,686 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:34:29,686 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:34:29,686 INFO OK: read value = false
2026-02-02 15:34:29,686 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:34:29,686 INFO OK: read value = false
2026-02-02 15:34:29,686 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:34:29,686 WARNING CHECK ERROR: read value = true
2026-02-02 15:34:29,686 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:34:29,686 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:34:29,687 INFO OK: read value = false
2026-02-02 15:34:29,687 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:34:29,687 INFO OK: read value = false
2026-02-02 15:34:29,687 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:34:29,687 INFO OK: read value = false
2026-02-02 15:34:29,687 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:34:29,687 INFO OK: read value = false
2026-02-02 15:34:29,687 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:34:29,688 INFO OK: read value = false
2026-02-02 15:34:29,688 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:34:29,688 INFO OK: read value = false
2026-02-02 15:34:29,688 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:34:29,688 WARNING CHECK ERROR: read value = RDR_FAIL
2026-02-02 15:34:29,688 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL
2026-02-02 15:34:29,689 WARNING Radar fail status: REAL failure (caused by: status, status)
2026-02-02 15:34:29,689 INFO [Run 3] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known
2026-02-02 15:34:29,689 INFO Known failures (HW setup): 1
2026-02-02 15:34:29,689 WARNING Real failures: status, status
2026-02-02 15:34:29,689 INFO
Drill-down: Verifying all 173 B8 diagnostic fields...
2026-02-02 15:34:29,689 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:34:29,689 INFO OK: read value = false
2026-02-02 15:34:29,690 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:34:29,690 INFO OK: read value = false
2026-02-02 15:34:29,690 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:34:29,690 INFO OK: read value = false
2026-02-02 15:34:29,690 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:34:29,690 INFO OK: read value = false
2026-02-02 15:34:29,691 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:34:29,691 INFO OK: read value = false
2026-02-02 15:34:29,691 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:34:29,691 INFO OK: read value = false
2026-02-02 15:34:29,692 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:34:29,692 INFO OK: read value = false
2026-02-02 15:34:29,692 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:34:29,693 INFO OK: read value = false
2026-02-02 15:34:29,693 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:34:29,693 INFO OK: read value = false
2026-02-02 15:34:29,693 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:34:29,693 WARNING CHECK ERROR: read value = 0
2026-02-02 15:34:29,694 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:34:29,694 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:34:29,694 INFO OK: read value = false
2026-02-02 15:34:29,695 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:34:29,695 INFO OK: read value = false
2026-02-02 15:34:29,695 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:34:29,696 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:34:29,696 INFO OK: read value = false
2026-02-02 15:34:29,696 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:34:29,696 INFO OK: read value = false
2026-02-02 15:34:29,697 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:34:29,698 INFO OK: read value = false
2026-02-02 15:34:29,698 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:34:29,699 INFO OK: read value = false
2026-02-02 15:34:29,699 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:34:29,699 INFO OK: read value = false
2026-02-02 15:34:29,700 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:34:29,700 INFO OK: read value = false
2026-02-02 15:34:29,700 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:34:29,701 INFO OK: read value = false
2026-02-02 15:34:29,701 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:34:29,701 INFO OK: read value = false
2026-02-02 15:34:29,701 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:34:29,702 INFO OK: read value = false
2026-02-02 15:34:29,702 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:34:29,702 INFO OK: read value = false
2026-02-02 15:34:29,702 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:34:29,704 INFO OK: read value = false
2026-02-02 15:34:29,704 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:34:29,704 INFO OK: read value = false
2026-02-02 15:34:29,704 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:34:29,704 INFO OK: read value = false
2026-02-02 15:34:29,705 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:34:29,705 INFO OK: read value = false
2026-02-02 15:34:29,705 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:34:29,705 INFO OK: read value = false
2026-02-02 15:34:29,705 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:34:29,706 INFO OK: read value = false
2026-02-02 15:34:29,706 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:34:29,706 INFO OK: read value = false
2026-02-02 15:34:29,707 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:34:29,707 INFO OK: read value = false
2026-02-02 15:34:29,708 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:34:29,708 INFO OK: read value = false
2026-02-02 15:34:29,708 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:34:29,709 INFO OK: read value = false
2026-02-02 15:34:29,709 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:34:29,710 INFO OK: read value = false
2026-02-02 15:34:29,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:34:29,710 INFO OK: read value = false
2026-02-02 15:34:29,711 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:34:29,711 INFO OK: read value = false
2026-02-02 15:34:29,712 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:34:29,712 INFO OK: read value = false
2026-02-02 15:34:29,712 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:34:29,713 INFO OK: read value = false
2026-02-02 15:34:29,713 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:34:29,713 INFO OK: read value = false
2026-02-02 15:34:29,713 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:34:29,714 INFO OK: read value = false
2026-02-02 15:34:29,714 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:34:29,715 INFO OK: read value = false
2026-02-02 15:34:29,715 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:34:29,715 INFO OK: read value = false
2026-02-02 15:34:29,716 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:34:29,716 INFO OK: read value = false
2026-02-02 15:34:29,716 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:34:29,716 INFO OK: read value = false
2026-02-02 15:34:29,717 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:34:29,717 INFO OK: read value = false
2026-02-02 15:34:29,717 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:34:29,718 INFO OK: read value = false
2026-02-02 15:34:29,718 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:34:29,718 INFO OK: read value = false
2026-02-02 15:34:29,719 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:34:29,719 INFO OK: read value = false
2026-02-02 15:34:29,719 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:34:29,721 INFO OK: read value = false
2026-02-02 15:34:29,721 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:34:29,721 INFO OK: read value = false
2026-02-02 15:34:29,721 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:34:29,721 INFO OK: read value = false
2026-02-02 15:34:29,721 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:34:29,721 INFO OK: read value = false
2026-02-02 15:34:29,722 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:34:29,722 INFO OK: read value = false
2026-02-02 15:34:29,722 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:34:29,723 INFO OK: read value = false
2026-02-02 15:34:29,723 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:34:29,723 INFO OK: read value = false
2026-02-02 15:34:29,723 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:34:29,724 INFO OK: read value = false
2026-02-02 15:34:29,724 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:34:29,724 INFO OK: read value = false
2026-02-02 15:34:29,724 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:34:29,725 INFO OK: read value = false
2026-02-02 15:34:29,725 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:34:29,725 INFO OK: read value = false
2026-02-02 15:34:29,725 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:34:29,725 INFO OK: read value = false
2026-02-02 15:34:29,726 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:34:29,726 INFO OK: read value = false
2026-02-02 15:34:29,726 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:34:29,726 INFO OK: read value = false
2026-02-02 15:34:29,726 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:34:29,726 INFO OK: read value = false
2026-02-02 15:34:29,727 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:34:29,727 INFO OK: read value = false
2026-02-02 15:34:29,727 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:34:29,727 INFO OK: read value = false
2026-02-02 15:34:29,727 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:34:29,727 INFO OK: read value = false
2026-02-02 15:34:29,727 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:34:29,728 INFO OK: read value = false
2026-02-02 15:34:29,728 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:34:29,728 INFO OK: read value = false
2026-02-02 15:34:29,728 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:34:29,728 INFO OK: read value = false
2026-02-02 15:34:29,729 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:34:29,729 INFO OK: read value = false
2026-02-02 15:34:29,729 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:34:29,729 INFO OK: read value = false
2026-02-02 15:34:29,729 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:34:29,730 INFO OK: read value = false
2026-02-02 15:34:29,730 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:34:29,730 INFO OK: read value = false
2026-02-02 15:34:29,730 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:34:29,731 INFO OK: read value = false
2026-02-02 15:34:29,731 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:34:29,731 INFO OK: read value = false
2026-02-02 15:34:29,731 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:34:29,731 INFO OK: read value = false
2026-02-02 15:34:29,732 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:34:29,732 INFO OK: read value = false
2026-02-02 15:34:29,732 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:34:29,732 INFO OK: read value = false
2026-02-02 15:34:29,733 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:34:29,733 INFO OK: read value = false
2026-02-02 15:34:29,733 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:34:29,733 INFO OK: read value = false
2026-02-02 15:34:29,734 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:34:29,734 INFO OK: read value = false
2026-02-02 15:34:29,734 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:34:29,735 INFO OK: read value = false
2026-02-02 15:34:29,735 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:34:29,735 INFO OK: read value = false
2026-02-02 15:34:29,737 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:34:29,737 INFO OK: read value = false
2026-02-02 15:34:29,737 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:34:29,737 INFO OK: read value = false
2026-02-02 15:34:29,738 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:34:29,738 INFO OK: read value = false
2026-02-02 15:34:29,738 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:34:29,738 INFO OK: read value = false
2026-02-02 15:34:29,738 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:34:29,738 INFO OK: read value = false
2026-02-02 15:34:29,738 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:34:29,738 INFO OK: read value = false
2026-02-02 15:34:29,738 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:34:29,739 INFO OK: read value = false
2026-02-02 15:34:29,739 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:34:29,739 INFO OK: read value = false
2026-02-02 15:34:29,739 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:34:29,739 INFO OK: read value = false
2026-02-02 15:34:29,739 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:34:29,739 INFO OK: read value = false
2026-02-02 15:34:29,742 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:34:29,742 INFO OK: read value = false
2026-02-02 15:34:29,742 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:34:29,742 INFO OK: read value = false
2026-02-02 15:34:29,742 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:34:29,742 INFO OK: read value = false
2026-02-02 15:34:29,742 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:34:29,742 INFO OK: read value = false
2026-02-02 15:34:29,743 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:34:29,743 INFO OK: read value = false
2026-02-02 15:34:29,743 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:34:29,743 INFO OK: read value = false
2026-02-02 15:34:29,744 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:34:29,744 INFO OK: read value = false
2026-02-02 15:34:29,744 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:34:29,744 INFO OK: read value = false
2026-02-02 15:34:29,745 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:34:29,745 INFO OK: read value = false
2026-02-02 15:34:29,745 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:34:29,745 INFO OK: read value = false
2026-02-02 15:34:29,745 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:34:29,747 INFO OK: read value = false
2026-02-02 15:34:29,747 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:34:29,747 INFO OK: read value = false
2026-02-02 15:34:29,747 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:34:29,748 INFO OK: read value = false
2026-02-02 15:34:29,748 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:34:29,748 INFO OK: read value = false
2026-02-02 15:34:29,748 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:34:29,748 INFO OK: read value = false
2026-02-02 15:34:29,748 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:34:29,748 INFO OK: read value = false
2026-02-02 15:34:29,748 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:34:29,748 INFO OK: read value = false
2026-02-02 15:34:29,748 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:34:29,748 INFO OK: read value = false
2026-02-02 15:34:29,749 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:34:29,749 INFO OK: read value = false
2026-02-02 15:34:29,749 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:34:29,749 INFO OK: read value = false
2026-02-02 15:34:29,749 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:34:29,751 INFO OK: read value = false
2026-02-02 15:34:29,751 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:34:29,751 INFO OK: read value = false
2026-02-02 15:34:29,751 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:34:29,751 INFO OK: read value = false
2026-02-02 15:34:29,751 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:34:29,751 INFO OK: read value = false
2026-02-02 15:34:29,751 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:34:29,757 INFO OK: read value = false
2026-02-02 15:34:29,757 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:34:29,758 INFO OK: read value = false
2026-02-02 15:34:29,758 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:34:29,758 INFO OK: read value = false
2026-02-02 15:34:29,758 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:34:29,758 INFO OK: read value = false
2026-02-02 15:34:29,759 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:34:29,759 INFO OK: read value = false
2026-02-02 15:34:29,759 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:34:29,759 INFO OK: read value = false
2026-02-02 15:34:29,759 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:34:29,760 INFO OK: read value = false
2026-02-02 15:34:29,760 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:34:29,760 INFO OK: read value = false
2026-02-02 15:34:29,760 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:34:29,761 INFO OK: read value = false
2026-02-02 15:34:29,761 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:34:29,761 INFO OK: read value = false
2026-02-02 15:34:29,762 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:34:29,762 INFO OK: read value = false
2026-02-02 15:34:29,762 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:34:29,762 INFO OK: read value = false
2026-02-02 15:34:29,762 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:34:29,763 INFO OK: read value = false
2026-02-02 15:34:29,763 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:34:29,763 INFO OK: read value = false
2026-02-02 15:34:29,763 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:34:29,763 INFO OK: read value = false
2026-02-02 15:34:29,764 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:34:29,764 INFO OK: read value = false
2026-02-02 15:34:29,764 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:34:29,764 INFO OK: read value = false
2026-02-02 15:34:29,765 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:34:29,765 INFO OK: read value = false
2026-02-02 15:34:29,765 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:34:29,765 INFO OK: read value = false
2026-02-02 15:34:29,765 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:34:29,765 INFO OK: read value = false
2026-02-02 15:34:29,766 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:34:29,766 INFO OK: read value = false
2026-02-02 15:34:29,766 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:34:29,766 WARNING CHECK ERROR: read value = true
2026-02-02 15:34:29,766 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:34:29,766 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:34:29,767 WARNING CHECK ERROR: read value = true
2026-02-02 15:34:29,767 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:34:29,767 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:34:29,767 WARNING CHECK ERROR: read value = true
2026-02-02 15:34:29,767 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:34:29,768 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:34:29,768 INFO OK: read value = false
2026-02-02 15:34:29,768 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:34:29,768 INFO OK: read value = false
2026-02-02 15:34:29,768 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:34:29,768 INFO OK: read value = false
2026-02-02 15:34:29,769 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:34:29,769 INFO OK: read value = false
2026-02-02 15:34:29,769 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:34:29,769 INFO OK: read value = false
2026-02-02 15:34:29,769 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:34:29,769 INFO OK: read value = false
2026-02-02 15:34:29,769 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:34:29,770 INFO OK: read value = false
2026-02-02 15:34:29,770 WARNING B8_Test_SignalProcessor: 3/14 failures
2026-02-02 15:34:29,770 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:34:29,770 INFO OK: read value = false
2026-02-02 15:34:29,770 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:34:29,770 INFO OK: read value = false
2026-02-02 15:34:29,770 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:34:29,770 INFO OK: read value = false
2026-02-02 15:34:29,771 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:34:29,771 INFO OK: read value = false
2026-02-02 15:34:29,771 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:34:29,771 INFO OK: read value = false
2026-02-02 15:34:29,771 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:34:29,771 INFO OK: read value = false
2026-02-02 15:34:29,771 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:34:29,771 INFO OK: read value = false
2026-02-02 15:34:29,772 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:34:29,772 INFO OK: read value = false
2026-02-02 15:34:29,772 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:34:29,772 INFO OK: read value = false
2026-02-02 15:34:29,772 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:34:29,773 INFO OK: read value = false
2026-02-02 15:34:29,773 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:34:29,773 INFO OK: read value = false
2026-02-02 15:34:29,773 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:34:29,774 INFO OK: read value = false
2026-02-02 15:34:29,774 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:34:29,774 INFO OK: read value = false
2026-02-02 15:34:29,774 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:34:29,775 INFO OK: read value = false
2026-02-02 15:34:29,775 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:34:29,775 INFO OK: read value = false
2026-02-02 15:34:29,775 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:34:29,776 INFO OK: read value = false
2026-02-02 15:34:29,776 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:34:29,776 INFO OK: read value = false
2026-02-02 15:34:29,776 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:34:29,776 INFO OK: read value = false
2026-02-02 15:34:29,777 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:34:29,777 INFO OK: read value = false
2026-02-02 15:34:29,777 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:34:29,777 INFO OK: read value = false
2026-02-02 15:34:29,778 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:34:29,778 INFO OK: read value = false
2026-02-02 15:34:29,778 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:34:29,779 INFO OK: read value = false
2026-02-02 15:34:29,779 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:34:29,779 INFO OK: read value = false
2026-02-02 15:34:29,779 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:34:29,779 INFO OK: read value = false
2026-02-02 15:34:29,779 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:34:29,779 INFO OK: read value = false
2026-02-02 15:34:29,780 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:34:29,780 INFO OK: read value = false
2026-02-02 15:34:29,780 INFO [Run 3] B8 Diagnostics: 173 checked, 169 pass, 4 fail
2026-02-02 15:34:29,780 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:34:29,780 WARNING B8_Test_SignalProcessor: 3 failures - up, if, internal
2026-02-02 15:34:29,780 INFO 0.0s remaining ...
2026-02-02 15:34:29,780 INFO [Run 3] Serial: 3 total, 0 errors, 3 fatal, 3 recycles
2026-02-02 15:34:29,780 INFO Target Detection Test
2026-02-02 15:34:29,780 INFO [Run 3] Starting target detection test (timeout: 5.0s)
2026-02-02 15:34:29,781 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:34:29,792 INFO TgtMsg: 3 3
2026-02-02 15:34:29,792 INFO Tgt: 1 @ 1180
2026-02-02 15:34:29,792 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:34:29,792 INFO OK: read value = 1
2026-02-02 15:34:29,792 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:34:29,792 INFO OK: read value = 1180
2026-02-02 15:34:29,792 INFO Target detected successfully in 0.01s
2026-02-02 15:34:29,792 INFO [Run 3] Target DETECTED in 0.01s
2026-02-02 15:34:29,792 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3
Total Step 192: Success 185 (96.35%), Failed 7 (3.65%),
2026-02-02 15:34:29,792 INFO Repetitions terminated.
2026-02-02 15:34:29,794 INFO [Report] Custom statistics data registered for PDF generation
2026-02-02 15:34:29,794 INFO ==========================================================================================
2026-02-02 15:34:29,794 INFO FINAL TEST STATISTICS SUMMARY
2026-02-02 15:34:29,794 INFO ==========================================================================================
2026-02-02 15:34:29,794 INFO Total Runs: 3
2026-02-02 15:34:29,795 INFO Successful: 1 (33.3%)
2026-02-02 15:34:29,795 INFO Failed: 2 (66.7%)
2026-02-02 15:34:29,795 INFO B6 Checks: 36 (Pass: 28, Fail: 4, Known: 4)
2026-02-02 15:34:29,795 INFO B8 Checks: 519 (Pass: 513, Fail: 6)
2026-02-02 15:34:29,795 INFO Serial: 6 messages (0 errors, 6 fatal, 6 recycles)
2026-02-02 15:34:29,795 INFO Target: 3 detected, 0 not detected (100.0% pass rate)
2026-02-02 15:34:29,795 INFO PBIT Timing: avg=0.24s, min=0.23s, max=0.24s, σ=0.00s
2026-02-02 15:34:29,795 INFO ==========================================================================================
2026-02-02 15:34:29,796 INFO Detailed statistics will be available in the PDF report
2026-02-02 15:34:29,796 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_153429_statistics.csv
2026-02-02 15:34:29,797 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_153429_statistics.csv
2026-02-02 15:34:29,799 INFO Statistics exported successfully to JSON: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_153429_statistics.json
2026-02-02 15:34:29,799 INFO Set MAIN_POWER to False
2026-02-02 15:34:29,799 INFO [MOCK] Power OFF
2026-02-02 15:34:29,799 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:34:34,814 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:34:34,814 INFO OK: read value = False
2026-02-02 15:34:34,814 INFO [MOCK] Serial terminal disconnected
2026-02-02 15:34:34,814 INFO Stop Time: 2026-02-02 15:33:39.717098
2026-02-02 15:34:34,814 INFO Test execution time: 0:00:55.097727