2026-02-02 15:58:16,770 INFO Start Time: 2026-02-02 15:58:16.770414
2026-02-02 15:58:16,771 INFO [MOCK] Serial terminal initialized
2026-02-02 15:58:16,771 INFO [MOCK] Serial terminal connected
2026-02-02 15:58:16,771 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:58:16,774 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-02-02 15:58:16,774 INFO [MOCK] Simulating target acquisition: will appear after 4 scan cycles
2026-02-02 15:58:16,783 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:58:16,845 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:58:16,909 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:58:16,973 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:58:17,028 INFO [MOCK] Target simulated at distance 1180
2026-02-02 15:58:17,028 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts
2026-02-02 15:58:17,028 INFO tgt_gen_alone(): 0
2026-02-02 15:58:17,029 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:58:17,043 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:58:17,043 INFO TgtMsg: 0 0
2026-02-02 15:58:17,044 INFO Tgt: 1 @ 1180
2026-02-02 15:58:17,044 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:58:17,044 INFO OK: read value = 1
2026-02-02 15:58:17,044 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:58:17,044 INFO OK: read value = 1180
2026-02-02 15:58:17,044 INFO [MOCK] Log stopped
2026-02-02 15:58:17,044 INFO Repetition 1 of 3
2026-02-02 15:58:17,045 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:58:17,045 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:58:18,050 INFO Set MAIN_POWER to False
2026-02-02 15:58:18,050 INFO [MOCK] Power OFF
2026-02-02 15:58:18,050 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:58:23,050 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:58:23,050 INFO OK: read value = False
2026-02-02 15:58:27,063 INFO The test operator is required to switch on the target.
2026-02-02 15:58:27,064 INFO Set MAIN_POWER to True
2026-02-02 15:58:27,064 INFO [MOCK] Power ON
2026-02-02 15:58:27,064 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:58:27,064 INFO run_count = 1
2026-02-02 15:58:27,064 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:58:27,064 INFO current_scenario = 'mixed'
2026-02-02 15:58:27,065 INFO _scenario_list = ['random_failures', 'transmitter_fail', 'normal']
2026-02-02 15:58:27,065 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:58:27,065 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='random_failures'
2026-02-02 15:58:27,065 INFO [DEBUG] About to call _log_scenario_info('random_failures', 1, 3)
2026-02-02 15:58:27,065 INFO
2026-02-02 15:58:27,065 INFO ####################################################################################################
2026-02-02 15:58:27,065 INFO ####################################################################################################
2026-02-02 15:58:27,065 INFO ### RUN 1/3: RANDOM COMPONENT FAILURES
2026-02-02 15:58:27,065 INFO ####################################################################################################
2026-02-02 15:58:27,066 INFO
2026-02-02 15:58:27,066 INFO SCENARIO: random_failures
2026-02-02 15:58:27,066 INFO DESCRIPTION: Random selection of component failures (30% proc, 20% tx, 15% rx)
2026-02-02 15:58:27,066 INFO
2026-02-02 15:58:27,066 INFO EXPECTED FAILURES:
2026-02-02 15:58:27,066 INFO ✗ Variable - one or more of: processor_status, trasmitter_status, receiver_status
2026-02-02 15:58:27,066 INFO
2026-02-02 15:58:27,066 INFO EXPECTED PASSES:
2026-02-02 15:58:27,067 INFO ✓ Non-failed components
2026-02-02 15:58:27,067 INFO ✓ B8 diagnostic fields
2026-02-02 15:58:27,067 INFO ✓ Target generation
2026-02-02 15:58:27,067 INFO
2026-02-02 15:58:27,067 INFO NOTES: Validates test handling of multiple simultaneous failures
2026-02-02 15:58:27,067 INFO
2026-02-02 15:58:27,068 INFO ####################################################################################################
2026-02-02 15:58:27,068 INFO ####################################################################################################
2026-02-02 15:58:27,068 INFO
2026-02-02 15:58:27,068 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:58:27,068 INFO [MOCK APPLY] ✓ No random failures triggered (all passed)
2026-02-02 15:58:27,068 INFO [MOCK] Run 1: Target will be VISIBLE (pattern index 0)
2026-02-02 15:58:27,068 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1)
2026-02-02 15:58:32,075 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:58:32,075 INFO OK: read value = True
2026-02-02 15:58:32,185 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:58:32,385 INFO [MOCK] BIT report available after 5.3s
2026-02-02 15:58:32,417 INFO BIT report available after 0.2s
2026-02-02 15:58:32,417 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:58:32,418 INFO OK: read value = false
2026-02-02 15:58:32,418 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:58:32,418 WARNING CHECK ERROR: read value = true
2026-02-02 15:58:32,418 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:58:32,418 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:58:32,419 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:58:32,419 INFO OK: read value = false
2026-02-02 15:58:32,419 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:58:32,419 INFO OK: read value = false
2026-02-02 15:58:32,419 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:58:32,419 INFO OK: read value = false
2026-02-02 15:58:32,420 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:58:32,420 INFO OK: read value = false
2026-02-02 15:58:32,420 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:58:32,420 INFO OK: read value = false
2026-02-02 15:58:32,420 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:58:32,420 INFO OK: read value = false
2026-02-02 15:58:32,420 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:58:32,420 INFO OK: read value = false
2026-02-02 15:58:32,420 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:58:32,421 INFO OK: read value = false
2026-02-02 15:58:32,421 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:58:32,421 INFO OK: read value = false
2026-02-02 15:58:32,421 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:58:32,421 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 15:58:32,422 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 15:58:32,422 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 15:58:32,422 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 15:58:32,422 INFO Known failures (HW setup): 2
2026-02-02 15:58:32,422 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 15:58:32,423 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 15:58:32,423 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:58:32,423 INFO OK: read value = false
2026-02-02 15:58:32,424 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:58:32,424 INFO OK: read value = false
2026-02-02 15:58:32,425 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:58:32,425 INFO OK: read value = false
2026-02-02 15:58:32,425 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:58:32,425 INFO OK: read value = false
2026-02-02 15:58:32,425 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:58:32,425 INFO OK: read value = false
2026-02-02 15:58:32,426 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:58:32,426 INFO OK: read value = false
2026-02-02 15:58:32,426 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:58:32,426 INFO OK: read value = false
2026-02-02 15:58:32,426 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:58:32,426 INFO OK: read value = false
2026-02-02 15:58:32,427 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:58:32,427 INFO OK: read value = false
2026-02-02 15:58:32,427 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:58:32,427 WARNING CHECK ERROR: read value = 0
2026-02-02 15:58:32,427 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:58:32,427 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:58:32,427 INFO OK: read value = false
2026-02-02 15:58:32,427 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:58:32,427 INFO OK: read value = false
2026-02-02 15:58:32,427 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:58:32,428 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:58:32,428 INFO OK: read value = false
2026-02-02 15:58:32,428 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:58:32,428 INFO OK: read value = false
2026-02-02 15:58:32,428 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:58:32,428 INFO OK: read value = false
2026-02-02 15:58:32,428 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:58:32,428 INFO OK: read value = false
2026-02-02 15:58:32,428 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:58:32,428 INFO OK: read value = false
2026-02-02 15:58:32,429 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:58:32,429 INFO OK: read value = false
2026-02-02 15:58:32,429 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:58:32,429 INFO OK: read value = false
2026-02-02 15:58:32,429 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:58:32,429 INFO OK: read value = false
2026-02-02 15:58:32,429 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:58:32,430 INFO OK: read value = false
2026-02-02 15:58:32,430 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:58:32,430 INFO OK: read value = false
2026-02-02 15:58:32,430 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:58:32,430 INFO OK: read value = false
2026-02-02 15:58:32,430 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:58:32,430 INFO OK: read value = false
2026-02-02 15:58:32,430 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:58:32,430 INFO OK: read value = false
2026-02-02 15:58:32,430 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:58:32,431 INFO OK: read value = false
2026-02-02 15:58:32,431 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:58:32,431 INFO OK: read value = false
2026-02-02 15:58:32,431 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:58:32,431 INFO OK: read value = false
2026-02-02 15:58:32,431 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:58:32,431 INFO OK: read value = false
2026-02-02 15:58:32,431 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:58:32,432 INFO OK: read value = false
2026-02-02 15:58:32,432 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:58:32,432 INFO OK: read value = false
2026-02-02 15:58:32,432 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:58:32,436 INFO OK: read value = false
2026-02-02 15:58:32,436 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:58:32,436 INFO OK: read value = false
2026-02-02 15:58:32,437 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:58:32,437 INFO OK: read value = false
2026-02-02 15:58:32,437 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:58:32,437 INFO OK: read value = false
2026-02-02 15:58:32,437 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:58:32,437 INFO OK: read value = false
2026-02-02 15:58:32,437 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:58:32,437 INFO OK: read value = false
2026-02-02 15:58:32,437 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:58:32,437 INFO OK: read value = false
2026-02-02 15:58:32,437 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:58:32,438 INFO OK: read value = false
2026-02-02 15:58:32,438 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:58:32,438 INFO OK: read value = false
2026-02-02 15:58:32,438 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:58:32,438 INFO OK: read value = false
2026-02-02 15:58:32,438 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:58:32,438 INFO OK: read value = false
2026-02-02 15:58:32,439 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:58:32,439 INFO OK: read value = false
2026-02-02 15:58:32,439 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:58:32,439 INFO OK: read value = false
2026-02-02 15:58:32,439 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:58:32,439 INFO OK: read value = false
2026-02-02 15:58:32,439 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:58:32,439 INFO OK: read value = false
2026-02-02 15:58:32,439 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:58:32,440 INFO OK: read value = false
2026-02-02 15:58:32,440 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:58:32,440 INFO OK: read value = false
2026-02-02 15:58:32,440 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:58:32,441 INFO OK: read value = false
2026-02-02 15:58:32,441 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:58:32,441 INFO OK: read value = false
2026-02-02 15:58:32,442 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:58:32,442 INFO OK: read value = false
2026-02-02 15:58:32,442 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:58:32,443 INFO OK: read value = false
2026-02-02 15:58:32,443 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:58:32,443 INFO OK: read value = false
2026-02-02 15:58:32,443 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:58:32,443 INFO OK: read value = false
2026-02-02 15:58:32,443 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:58:32,443 INFO OK: read value = false
2026-02-02 15:58:32,444 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:58:32,444 INFO OK: read value = false
2026-02-02 15:58:32,444 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:58:32,444 INFO OK: read value = false
2026-02-02 15:58:32,445 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:58:32,445 INFO OK: read value = false
2026-02-02 15:58:32,445 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:58:32,445 INFO OK: read value = false
2026-02-02 15:58:32,445 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:58:32,445 INFO OK: read value = false
2026-02-02 15:58:32,446 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:58:32,446 INFO OK: read value = false
2026-02-02 15:58:32,447 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:58:32,447 INFO OK: read value = false
2026-02-02 15:58:32,448 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:58:32,448 INFO OK: read value = false
2026-02-02 15:58:32,448 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:58:32,449 INFO OK: read value = false
2026-02-02 15:58:32,449 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:58:32,450 INFO OK: read value = false
2026-02-02 15:58:32,450 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:58:32,450 INFO OK: read value = false
2026-02-02 15:58:32,451 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:58:32,451 INFO OK: read value = false
2026-02-02 15:58:32,452 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:58:32,452 INFO OK: read value = false
2026-02-02 15:58:32,452 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:58:32,452 INFO OK: read value = false
2026-02-02 15:58:32,452 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:58:32,453 INFO OK: read value = false
2026-02-02 15:58:32,453 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:58:32,453 INFO OK: read value = false
2026-02-02 15:58:32,453 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:58:32,454 INFO OK: read value = false
2026-02-02 15:58:32,454 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:58:32,454 INFO OK: read value = false
2026-02-02 15:58:32,454 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:58:32,454 INFO OK: read value = false
2026-02-02 15:58:32,454 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:58:32,454 INFO OK: read value = false
2026-02-02 15:58:32,454 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:58:32,454 INFO OK: read value = false
2026-02-02 15:58:32,454 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:58:32,455 INFO OK: read value = false
2026-02-02 15:58:32,455 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:58:32,455 INFO OK: read value = false
2026-02-02 15:58:32,455 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:58:32,455 INFO OK: read value = false
2026-02-02 15:58:32,455 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:58:32,455 INFO OK: read value = false
2026-02-02 15:58:32,455 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:58:32,455 INFO OK: read value = false
2026-02-02 15:58:32,456 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:58:32,456 INFO OK: read value = false
2026-02-02 15:58:32,456 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:58:32,456 INFO OK: read value = false
2026-02-02 15:58:32,456 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:58:32,456 INFO OK: read value = false
2026-02-02 15:58:32,457 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:58:32,457 INFO OK: read value = false
2026-02-02 15:58:32,457 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:58:32,457 INFO OK: read value = false
2026-02-02 15:58:32,458 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:58:32,458 INFO OK: read value = false
2026-02-02 15:58:32,458 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:58:32,459 INFO OK: read value = false
2026-02-02 15:58:32,459 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:58:32,459 INFO OK: read value = false
2026-02-02 15:58:32,459 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:58:32,459 INFO OK: read value = false
2026-02-02 15:58:32,460 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:58:32,460 INFO OK: read value = false
2026-02-02 15:58:32,460 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:58:32,460 INFO OK: read value = false
2026-02-02 15:58:32,461 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:58:32,461 INFO OK: read value = false
2026-02-02 15:58:32,461 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:58:32,462 INFO OK: read value = false
2026-02-02 15:58:32,462 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:58:32,462 INFO OK: read value = false
2026-02-02 15:58:32,463 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:58:32,463 INFO OK: read value = false
2026-02-02 15:58:32,463 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:58:32,463 INFO OK: read value = false
2026-02-02 15:58:32,464 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:58:32,464 INFO OK: read value = false
2026-02-02 15:58:32,464 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:58:32,465 INFO OK: read value = false
2026-02-02 15:58:32,465 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:58:32,465 INFO OK: read value = false
2026-02-02 15:58:32,466 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:58:32,466 INFO OK: read value = false
2026-02-02 15:58:32,466 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:58:32,467 INFO OK: read value = false
2026-02-02 15:58:32,468 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:58:32,468 INFO OK: read value = false
2026-02-02 15:58:32,468 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:58:32,468 INFO OK: read value = false
2026-02-02 15:58:32,468 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:58:32,468 INFO OK: read value = false
2026-02-02 15:58:32,468 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:58:32,468 INFO OK: read value = false
2026-02-02 15:58:32,468 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:58:32,469 INFO OK: read value = false
2026-02-02 15:58:32,469 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:58:32,469 INFO OK: read value = false
2026-02-02 15:58:32,469 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:58:32,469 INFO OK: read value = false
2026-02-02 15:58:32,469 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:58:32,470 INFO OK: read value = false
2026-02-02 15:58:32,470 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:58:32,470 INFO OK: read value = false
2026-02-02 15:58:32,470 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:58:32,470 INFO OK: read value = false
2026-02-02 15:58:32,470 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:58:32,470 INFO OK: read value = false
2026-02-02 15:58:32,470 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:58:32,471 INFO OK: read value = false
2026-02-02 15:58:32,471 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:58:32,471 INFO OK: read value = false
2026-02-02 15:58:32,472 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:58:32,472 INFO OK: read value = false
2026-02-02 15:58:32,472 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:58:32,472 INFO OK: read value = false
2026-02-02 15:58:32,472 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:58:32,473 INFO OK: read value = false
2026-02-02 15:58:32,473 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:58:32,473 INFO OK: read value = false
2026-02-02 15:58:32,473 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:58:32,474 INFO OK: read value = false
2026-02-02 15:58:32,474 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:58:32,474 INFO OK: read value = false
2026-02-02 15:58:32,474 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:58:32,475 INFO OK: read value = false
2026-02-02 15:58:32,475 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:58:32,475 INFO OK: read value = false
2026-02-02 15:58:32,475 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:58:32,476 INFO OK: read value = false
2026-02-02 15:58:32,476 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:58:32,476 INFO OK: read value = false
2026-02-02 15:58:32,477 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:58:32,477 INFO OK: read value = false
2026-02-02 15:58:32,477 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:58:32,477 INFO OK: read value = false
2026-02-02 15:58:32,477 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:58:32,478 INFO OK: read value = false
2026-02-02 15:58:32,478 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:58:32,478 INFO OK: read value = false
2026-02-02 15:58:32,478 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:58:32,479 INFO OK: read value = false
2026-02-02 15:58:32,479 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:58:32,479 INFO OK: read value = false
2026-02-02 15:58:32,479 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:58:32,479 INFO OK: read value = false
2026-02-02 15:58:32,479 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:58:32,480 INFO OK: read value = false
2026-02-02 15:58:32,480 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:58:32,480 INFO OK: read value = false
2026-02-02 15:58:32,480 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:58:32,480 INFO OK: read value = false
2026-02-02 15:58:32,481 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:58:32,481 INFO OK: read value = false
2026-02-02 15:58:32,481 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:58:32,481 INFO OK: read value = false
2026-02-02 15:58:32,481 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:58:32,481 INFO OK: read value = false
2026-02-02 15:58:32,482 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:58:32,482 INFO OK: read value = false
2026-02-02 15:58:32,482 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:58:32,482 INFO OK: read value = false
2026-02-02 15:58:32,482 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:58:32,482 INFO OK: read value = false
2026-02-02 15:58:32,482 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:58:32,482 INFO OK: read value = false
2026-02-02 15:58:32,483 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:58:32,483 INFO OK: read value = false
2026-02-02 15:58:32,483 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:58:32,483 INFO OK: read value = false
2026-02-02 15:58:32,484 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:58:32,484 INFO OK: read value = false
2026-02-02 15:58:32,484 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:58:32,484 INFO OK: read value = false
2026-02-02 15:58:32,484 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:58:32,485 INFO OK: read value = false
2026-02-02 15:58:32,485 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:58:32,485 INFO OK: read value = false
2026-02-02 15:58:32,485 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:58:32,486 INFO OK: read value = false
2026-02-02 15:58:32,486 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:58:32,487 INFO OK: read value = false
2026-02-02 15:58:32,487 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:58:32,487 INFO OK: read value = false
2026-02-02 15:58:32,488 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:58:32,488 INFO OK: read value = false
2026-02-02 15:58:32,489 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:58:32,489 INFO OK: read value = false
2026-02-02 15:58:32,489 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:58:32,490 INFO OK: read value = false
2026-02-02 15:58:32,490 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:58:32,490 INFO OK: read value = false
2026-02-02 15:58:32,490 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:58:32,490 INFO OK: read value = false
2026-02-02 15:58:32,491 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:58:32,491 INFO OK: read value = false
2026-02-02 15:58:32,491 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:58:32,491 INFO OK: read value = false
2026-02-02 15:58:32,491 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:58:32,491 INFO OK: read value = false
2026-02-02 15:58:32,491 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:58:32,491 INFO OK: read value = false
2026-02-02 15:58:32,491 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:58:32,491 INFO OK: read value = false
2026-02-02 15:58:32,492 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:58:32,492 INFO OK: read value = false
2026-02-02 15:58:32,492 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:58:32,492 INFO OK: read value = false
2026-02-02 15:58:32,492 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:58:32,492 INFO OK: read value = false
2026-02-02 15:58:32,492 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:58:32,492 INFO OK: read value = false
2026-02-02 15:58:32,493 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:58:32,493 INFO OK: read value = false
2026-02-02 15:58:32,493 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:58:32,493 INFO OK: read value = false
2026-02-02 15:58:32,493 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:58:32,493 INFO OK: read value = false
2026-02-02 15:58:32,493 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:58:32,493 INFO OK: read value = false
2026-02-02 15:58:32,493 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:58:32,494 INFO OK: read value = false
2026-02-02 15:58:32,494 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:58:32,494 INFO OK: read value = false
2026-02-02 15:58:32,494 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:58:32,494 INFO OK: read value = false
2026-02-02 15:58:32,494 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:58:32,494 INFO OK: read value = false
2026-02-02 15:58:32,494 INFO [Run 1] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:58:32,495 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:58:32,495 INFO 0.0s remaining ...
2026-02-02 15:58:32,495 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 15:58:32,495 INFO Target Detection Test
2026-02-02 15:58:32,495 INFO [Run 1] Starting target detection test (timeout: 5.0s)
2026-02-02 15:58:32,495 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:58:32,514 INFO TgtMsg: 1 1
2026-02-02 15:58:32,514 INFO Tgt: 1 @ 1180
2026-02-02 15:58:32,514 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:58:32,514 INFO OK: read value = 1
2026-02-02 15:58:32,514 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:58:32,514 INFO OK: read value = 1180
2026-02-02 15:58:32,514 INFO Target detected successfully in 0.02s
2026-02-02 15:58:32,514 INFO [Run 1] Target DETECTED in 0.02s
2026-02-02 15:58:32,516 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3
Total Step 194: Success 191 (98.45%), Failed 3 (1.55%),
2026-02-02 15:58:32,516 INFO Repetition 2 of 3
2026-02-02 15:58:32,516 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:58:32,516 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:58:33,524 INFO Set MAIN_POWER to False
2026-02-02 15:58:33,524 INFO [MOCK] Power OFF
2026-02-02 15:58:33,524 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:58:38,532 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:58:38,533 INFO OK: read value = False
2026-02-02 15:58:42,534 INFO The test operator is required to switch on the target.
2026-02-02 15:58:42,535 INFO Set MAIN_POWER to True
2026-02-02 15:58:42,535 INFO [MOCK] Power ON
2026-02-02 15:58:42,535 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:58:42,536 INFO run_count = 2
2026-02-02 15:58:42,536 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:58:42,536 INFO current_scenario = 'mixed'
2026-02-02 15:58:42,536 INFO _scenario_list = ['random_failures', 'transmitter_fail', 'normal']
2026-02-02 15:58:42,536 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:58:42,537 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='transmitter_fail'
2026-02-02 15:58:42,537 INFO [DEBUG] About to call _log_scenario_info('transmitter_fail', 2, 3)
2026-02-02 15:58:42,537 INFO
2026-02-02 15:58:42,537 INFO ####################################################################################################
2026-02-02 15:58:42,537 INFO ####################################################################################################
2026-02-02 15:58:42,537 INFO ### RUN 2/3: TRANSMITTER FAILURE
2026-02-02 15:58:42,537 INFO ####################################################################################################
2026-02-02 15:58:42,537 INFO
2026-02-02 15:58:42,537 INFO SCENARIO: transmitter_fail
2026-02-02 15:58:42,538 INFO DESCRIPTION: Transmitter subsystem failure detected
2026-02-02 15:58:42,538 INFO
2026-02-02 15:58:42,538 INFO EXPECTED FAILURES:
2026-02-02 15:58:42,538 INFO ✗ B6: trasmitter_status = FAIL
2026-02-02 15:58:42,538 INFO ✗ B6: radar_fail_status = RDR_FAIL
2026-02-02 15:58:42,538 INFO
2026-02-02 15:58:42,538 INFO EXPECTED PASSES:
2026-02-02 15:58:42,538 INFO ✓ Other B6 fields
2026-02-02 15:58:42,538 INFO ✓ B8 diagnostic fields
2026-02-02 15:58:42,538 INFO ✓ Target generation
2026-02-02 15:58:42,538 INFO
2026-02-02 15:58:42,538 INFO NOTES: Test should detect transmitter failure and trigger B8 drill-down
2026-02-02 15:58:42,539 INFO
2026-02-02 15:58:42,539 INFO ####################################################################################################
2026-02-02 15:58:42,539 INFO ####################################################################################################
2026-02-02 15:58:42,539 INFO
2026-02-02 15:58:42,539 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:58:42,539 INFO [MOCK APPLY] ✗ Setting trasmitter_status = FAIL
2026-02-02 15:58:42,539 INFO [MOCK APPLY] ✗ Setting radar_fail_status = RDR_FAIL
2026-02-02 15:58:42,539 INFO [MOCK] Run 2: Target will be NOT VISIBLE (pattern index 1)
2026-02-02 15:58:42,539 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-02-02 15:58:47,550 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:58:47,550 INFO OK: read value = True
2026-02-02 15:58:47,659 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:58:47,867 INFO [MOCK] BIT report available after 5.3s
2026-02-02 15:58:47,898 INFO BIT report available after 0.2s
2026-02-02 15:58:47,899 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:58:47,899 INFO OK: read value = false
2026-02-02 15:58:47,899 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:58:47,900 WARNING CHECK ERROR: read value = true
2026-02-02 15:58:47,900 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:58:47,900 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:58:47,900 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:58:47,900 INFO OK: read value = false
2026-02-02 15:58:47,901 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:58:47,901 INFO OK: read value = false
2026-02-02 15:58:47,901 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:58:47,902 INFO OK: read value = false
2026-02-02 15:58:47,902 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:58:47,902 INFO OK: read value = false
2026-02-02 15:58:47,902 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:58:47,902 INFO OK: read value = false
2026-02-02 15:58:47,902 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:58:47,902 INFO OK: read value = false
2026-02-02 15:58:47,903 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:58:47,903 INFO OK: read value = false
2026-02-02 15:58:47,903 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:58:47,904 INFO OK: read value = false
2026-02-02 15:58:47,904 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:58:47,904 WARNING CHECK ERROR: read value = true
2026-02-02 15:58:47,904 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:58:47,905 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:58:47,905 WARNING CHECK ERROR: read value = RDR_FAIL
2026-02-02 15:58:47,905 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL
2026-02-02 15:58:47,905 WARNING Radar fail status: REAL failure (caused by: status, status)
2026-02-02 15:58:47,906 INFO [Run 2] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known
2026-02-02 15:58:47,906 INFO Known failures (HW setup): 1
2026-02-02 15:58:47,906 WARNING Real failures: status, status
2026-02-02 15:58:47,906 INFO
Drill-down: Verifying all 173 B8 diagnostic fields...
2026-02-02 15:58:47,906 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:58:47,908 INFO OK: read value = false
2026-02-02 15:58:47,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:58:47,908 INFO OK: read value = false
2026-02-02 15:58:47,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:58:47,908 INFO OK: read value = false
2026-02-02 15:58:47,909 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:58:47,909 INFO OK: read value = false
2026-02-02 15:58:47,909 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:58:47,910 INFO OK: read value = false
2026-02-02 15:58:47,911 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:58:47,911 INFO OK: read value = false
2026-02-02 15:58:47,911 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:58:47,911 INFO OK: read value = false
2026-02-02 15:58:47,911 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:58:47,911 INFO OK: read value = false
2026-02-02 15:58:47,911 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:58:47,911 INFO OK: read value = false
2026-02-02 15:58:47,912 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:58:47,912 WARNING CHECK ERROR: read value = 0
2026-02-02 15:58:47,912 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:58:47,912 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:58:47,912 INFO OK: read value = false
2026-02-02 15:58:47,912 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:58:47,912 INFO OK: read value = false
2026-02-02 15:58:47,912 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:58:47,913 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:58:47,913 INFO OK: read value = false
2026-02-02 15:58:47,913 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:58:47,913 INFO OK: read value = false
2026-02-02 15:58:47,913 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:58:47,913 INFO OK: read value = false
2026-02-02 15:58:47,913 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:58:47,914 INFO OK: read value = false
2026-02-02 15:58:47,914 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:58:47,914 INFO OK: read value = false
2026-02-02 15:58:47,915 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:58:47,916 INFO OK: read value = false
2026-02-02 15:58:47,916 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:58:47,916 INFO OK: read value = false
2026-02-02 15:58:47,916 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:58:47,918 INFO OK: read value = false
2026-02-02 15:58:47,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:58:47,918 INFO OK: read value = false
2026-02-02 15:58:47,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:58:47,918 INFO OK: read value = false
2026-02-02 15:58:47,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:58:47,918 INFO OK: read value = false
2026-02-02 15:58:47,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:58:47,918 INFO OK: read value = false
2026-02-02 15:58:47,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:58:47,919 INFO OK: read value = false
2026-02-02 15:58:47,919 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:58:47,919 INFO OK: read value = false
2026-02-02 15:58:47,919 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:58:47,919 INFO OK: read value = false
2026-02-02 15:58:47,919 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:58:47,919 INFO OK: read value = false
2026-02-02 15:58:47,920 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:58:47,920 INFO OK: read value = false
2026-02-02 15:58:47,920 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:58:47,920 INFO OK: read value = false
2026-02-02 15:58:47,920 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:58:47,920 INFO OK: read value = false
2026-02-02 15:58:47,921 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:58:47,921 INFO OK: read value = false
2026-02-02 15:58:47,921 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:58:47,921 INFO OK: read value = false
2026-02-02 15:58:47,921 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:58:47,921 INFO OK: read value = false
2026-02-02 15:58:47,921 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:58:47,921 INFO OK: read value = false
2026-02-02 15:58:47,922 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:58:47,922 INFO OK: read value = false
2026-02-02 15:58:47,922 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:58:47,922 INFO OK: read value = false
2026-02-02 15:58:47,922 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:58:47,923 INFO OK: read value = false
2026-02-02 15:58:47,923 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:58:47,923 INFO OK: read value = false
2026-02-02 15:58:47,923 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:58:47,923 INFO OK: read value = false
2026-02-02 15:58:47,923 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:58:47,924 INFO OK: read value = false
2026-02-02 15:58:47,924 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:58:47,924 INFO OK: read value = false
2026-02-02 15:58:47,924 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:58:47,924 INFO OK: read value = false
2026-02-02 15:58:47,924 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:58:47,926 INFO OK: read value = false
2026-02-02 15:58:47,926 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:58:47,926 INFO OK: read value = false
2026-02-02 15:58:47,926 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:58:47,926 INFO OK: read value = false
2026-02-02 15:58:47,926 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:58:47,926 INFO OK: read value = false
2026-02-02 15:58:47,926 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:58:47,926 INFO OK: read value = false
2026-02-02 15:58:47,926 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:58:47,926 INFO OK: read value = false
2026-02-02 15:58:47,926 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:58:47,927 INFO OK: read value = false
2026-02-02 15:58:47,927 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:58:47,927 INFO OK: read value = false
2026-02-02 15:58:47,927 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:58:47,928 INFO OK: read value = false
2026-02-02 15:58:47,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:58:47,928 INFO OK: read value = false
2026-02-02 15:58:47,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:58:47,928 INFO OK: read value = false
2026-02-02 15:58:47,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:58:47,928 INFO OK: read value = false
2026-02-02 15:58:47,928 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:58:47,929 INFO OK: read value = false
2026-02-02 15:58:47,929 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:58:47,929 INFO OK: read value = false
2026-02-02 15:58:47,929 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:58:47,929 INFO OK: read value = false
2026-02-02 15:58:47,930 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:58:47,930 INFO OK: read value = false
2026-02-02 15:58:47,930 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:58:47,930 INFO OK: read value = false
2026-02-02 15:58:47,930 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:58:47,930 INFO OK: read value = false
2026-02-02 15:58:47,931 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:58:47,931 INFO OK: read value = false
2026-02-02 15:58:47,931 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:58:47,931 INFO OK: read value = false
2026-02-02 15:58:47,931 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:58:47,932 INFO OK: read value = false
2026-02-02 15:58:47,932 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:58:47,932 INFO OK: read value = false
2026-02-02 15:58:47,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:58:47,933 INFO OK: read value = false
2026-02-02 15:58:47,933 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:58:47,933 INFO OK: read value = false
2026-02-02 15:58:47,933 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:58:47,937 INFO OK: read value = false
2026-02-02 15:58:47,937 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:58:47,937 INFO OK: read value = false
2026-02-02 15:58:47,937 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:58:47,937 INFO OK: read value = false
2026-02-02 15:58:47,937 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:58:47,938 INFO OK: read value = false
2026-02-02 15:58:47,938 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:58:47,938 INFO OK: read value = false
2026-02-02 15:58:47,941 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:58:47,941 INFO OK: read value = false
2026-02-02 15:58:47,941 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:58:47,941 INFO OK: read value = false
2026-02-02 15:58:47,941 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:58:47,941 INFO OK: read value = false
2026-02-02 15:58:47,941 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:58:47,941 INFO OK: read value = false
2026-02-02 15:58:47,942 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:58:47,942 INFO OK: read value = false
2026-02-02 15:58:47,942 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:58:47,943 INFO OK: read value = false
2026-02-02 15:58:47,943 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:58:47,943 INFO OK: read value = false
2026-02-02 15:58:47,944 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:58:47,944 INFO OK: read value = false
2026-02-02 15:58:47,944 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:58:47,946 INFO OK: read value = false
2026-02-02 15:58:47,946 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:58:47,946 INFO OK: read value = false
2026-02-02 15:58:47,946 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:58:47,946 INFO OK: read value = false
2026-02-02 15:58:47,946 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:58:47,946 INFO OK: read value = false
2026-02-02 15:58:47,946 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:58:47,948 INFO OK: read value = false
2026-02-02 15:58:47,948 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:58:47,948 INFO OK: read value = false
2026-02-02 15:58:47,948 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:58:47,948 INFO OK: read value = false
2026-02-02 15:58:47,948 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:58:47,948 INFO OK: read value = false
2026-02-02 15:58:47,948 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:58:47,948 INFO OK: read value = false
2026-02-02 15:58:47,948 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:58:47,948 INFO OK: read value = false
2026-02-02 15:58:47,948 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:58:47,948 INFO OK: read value = false
2026-02-02 15:58:47,948 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:58:47,949 INFO OK: read value = false
2026-02-02 15:58:47,949 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:58:47,949 INFO OK: read value = false
2026-02-02 15:58:47,949 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:58:47,949 INFO OK: read value = false
2026-02-02 15:58:47,949 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:58:47,950 INFO OK: read value = false
2026-02-02 15:58:47,950 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:58:47,950 INFO OK: read value = false
2026-02-02 15:58:47,951 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:58:47,951 INFO OK: read value = false
2026-02-02 15:58:47,951 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:58:47,951 INFO OK: read value = false
2026-02-02 15:58:47,953 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:58:47,953 INFO OK: read value = false
2026-02-02 15:58:47,954 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:58:47,954 INFO OK: read value = false
2026-02-02 15:58:47,954 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:58:47,955 INFO OK: read value = false
2026-02-02 15:58:47,955 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:58:47,955 INFO OK: read value = false
2026-02-02 15:58:47,955 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:58:47,955 INFO OK: read value = false
2026-02-02 15:58:47,955 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:58:47,956 INFO OK: read value = false
2026-02-02 15:58:47,956 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:58:47,956 INFO OK: read value = false
2026-02-02 15:58:47,956 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:58:47,956 INFO OK: read value = false
2026-02-02 15:58:47,956 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:58:47,957 INFO OK: read value = false
2026-02-02 15:58:47,957 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:58:47,957 INFO OK: read value = false
2026-02-02 15:58:47,957 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:58:47,957 INFO OK: read value = false
2026-02-02 15:58:47,957 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:58:47,958 INFO OK: read value = false
2026-02-02 15:58:47,958 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:58:47,958 INFO OK: read value = false
2026-02-02 15:58:47,959 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:58:47,959 INFO OK: read value = false
2026-02-02 15:58:47,959 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:58:47,959 INFO OK: read value = false
2026-02-02 15:58:47,959 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:58:47,960 INFO OK: read value = false
2026-02-02 15:58:47,960 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:58:47,960 INFO OK: read value = false
2026-02-02 15:58:47,960 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:58:47,960 INFO OK: read value = false
2026-02-02 15:58:47,961 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:58:47,961 INFO OK: read value = false
2026-02-02 15:58:47,961 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:58:47,961 INFO OK: read value = false
2026-02-02 15:58:47,962 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:58:47,962 INFO OK: read value = false
2026-02-02 15:58:47,962 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:58:47,962 INFO OK: read value = false
2026-02-02 15:58:47,963 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:58:47,963 INFO OK: read value = false
2026-02-02 15:58:47,963 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:58:47,963 INFO OK: read value = false
2026-02-02 15:58:47,963 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:58:47,963 INFO OK: read value = false
2026-02-02 15:58:47,963 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:58:47,963 INFO OK: read value = false
2026-02-02 15:58:47,964 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:58:47,964 INFO OK: read value = false
2026-02-02 15:58:47,964 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:58:47,964 INFO OK: read value = false
2026-02-02 15:58:47,964 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:58:47,964 INFO OK: read value = false
2026-02-02 15:58:47,964 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:58:47,964 INFO OK: read value = false
2026-02-02 15:58:47,965 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:58:47,965 INFO OK: read value = false
2026-02-02 15:58:47,965 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:58:47,965 INFO OK: read value = false
2026-02-02 15:58:47,965 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:58:47,966 INFO OK: read value = false
2026-02-02 15:58:47,966 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:58:47,966 INFO OK: read value = false
2026-02-02 15:58:47,966 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:58:47,967 INFO OK: read value = false
2026-02-02 15:58:47,967 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:58:47,967 INFO OK: read value = false
2026-02-02 15:58:47,968 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:58:47,968 INFO OK: read value = false
2026-02-02 15:58:47,968 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:58:47,969 INFO OK: read value = false
2026-02-02 15:58:47,969 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:58:47,969 INFO OK: read value = false
2026-02-02 15:58:47,969 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:58:47,970 INFO OK: read value = false
2026-02-02 15:58:47,971 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:58:47,971 INFO OK: read value = false
2026-02-02 15:58:47,971 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:58:47,971 INFO OK: read value = false
2026-02-02 15:58:47,971 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:58:47,972 INFO OK: read value = false
2026-02-02 15:58:47,972 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:58:47,972 INFO OK: read value = false
2026-02-02 15:58:47,972 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:58:47,972 INFO OK: read value = false
2026-02-02 15:58:47,972 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:58:47,972 INFO OK: read value = false
2026-02-02 15:58:47,972 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:58:47,972 INFO OK: read value = false
2026-02-02 15:58:47,972 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:58:47,972 INFO OK: read value = false
2026-02-02 15:58:47,973 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:58:47,973 INFO OK: read value = false
2026-02-02 15:58:47,973 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:58:47,973 INFO OK: read value = false
2026-02-02 15:58:47,973 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:58:47,973 INFO OK: read value = false
2026-02-02 15:58:47,974 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:58:47,974 INFO OK: read value = false
2026-02-02 15:58:47,974 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:58:47,974 INFO OK: read value = false
2026-02-02 15:58:47,974 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:58:47,974 INFO OK: read value = false
2026-02-02 15:58:47,975 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:58:47,975 INFO OK: read value = false
2026-02-02 15:58:47,975 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:58:47,975 INFO OK: read value = false
2026-02-02 15:58:47,975 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:58:47,976 INFO OK: read value = false
2026-02-02 15:58:47,976 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:58:47,976 INFO OK: read value = false
2026-02-02 15:58:47,976 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:58:47,976 INFO OK: read value = false
2026-02-02 15:58:47,976 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:58:47,977 INFO OK: read value = false
2026-02-02 15:58:47,977 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:58:47,977 INFO OK: read value = false
2026-02-02 15:58:47,977 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:58:47,977 INFO OK: read value = false
2026-02-02 15:58:47,977 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:58:47,978 INFO OK: read value = false
2026-02-02 15:58:47,978 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:58:47,978 INFO OK: read value = false
2026-02-02 15:58:47,978 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:58:47,978 INFO OK: read value = false
2026-02-02 15:58:47,979 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:58:47,979 INFO OK: read value = false
2026-02-02 15:58:47,979 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:58:47,979 INFO OK: read value = false
2026-02-02 15:58:47,979 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:58:47,980 INFO OK: read value = false
2026-02-02 15:58:47,980 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:58:47,980 INFO OK: read value = false
2026-02-02 15:58:47,980 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:58:47,980 INFO OK: read value = false
2026-02-02 15:58:47,980 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:58:47,980 INFO OK: read value = false
2026-02-02 15:58:47,981 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:58:47,981 INFO OK: read value = false
2026-02-02 15:58:47,981 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:58:47,981 INFO OK: read value = false
2026-02-02 15:58:47,981 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:58:47,981 INFO OK: read value = false
2026-02-02 15:58:47,981 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:58:47,981 INFO OK: read value = false
2026-02-02 15:58:47,981 INFO [Run 2] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:58:47,981 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:58:47,982 INFO 0.0s remaining ...
2026-02-02 15:58:47,982 INFO [Run 2] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 15:58:47,982 INFO Target Detection Test
2026-02-02 15:58:47,982 INFO [Run 2] Starting target detection test (timeout: 5.0s)
2026-02-02 15:58:47,982 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:58:47,994 INFO TgtMsg: 2 2
2026-02-02 15:58:48,146 INFO TgtMsg: 12 10
2026-02-02 15:58:48,314 INFO TgtMsg: 22 10
2026-02-02 15:58:48,487 INFO TgtMsg: 32 10
2026-02-02 15:58:48,648 INFO TgtMsg: 42 10
2026-02-02 15:58:48,814 INFO TgtMsg: 52 10
2026-02-02 15:58:48,972 INFO TgtMsg: 62 10
2026-02-02 15:58:49,128 INFO TgtMsg: 72 10
2026-02-02 15:58:49,280 INFO TgtMsg: 82 10
2026-02-02 15:58:49,437 INFO TgtMsg: 92 10
2026-02-02 15:58:49,557 DEBUG [MOCK] Message B9: counter at 100
2026-02-02 15:58:49,591 INFO TgtMsg: 102 10
2026-02-02 15:58:49,747 INFO TgtMsg: 112 10
2026-02-02 15:58:49,907 INFO TgtMsg: 122 10
2026-02-02 15:58:50,069 INFO TgtMsg: 132 10
2026-02-02 15:58:50,226 INFO TgtMsg: 142 10
2026-02-02 15:58:50,381 INFO TgtMsg: 152 10
2026-02-02 15:58:50,540 INFO TgtMsg: 162 10
2026-02-02 15:58:50,710 INFO TgtMsg: 172 10
2026-02-02 15:58:50,877 INFO TgtMsg: 182 10
2026-02-02 15:58:51,029 INFO TgtMsg: 192 10
2026-02-02 15:58:51,162 DEBUG [MOCK] Message B9: counter at 200
2026-02-02 15:58:51,194 INFO TgtMsg: 202 10
2026-02-02 15:58:51,358 INFO TgtMsg: 212 10
2026-02-02 15:58:51,519 INFO TgtMsg: 222 10
2026-02-02 15:58:51,688 INFO TgtMsg: 232 10
2026-02-02 15:58:51,844 INFO TgtMsg: 242 10
2026-02-02 15:58:52,008 INFO TgtMsg: 252 10
2026-02-02 15:58:52,171 INFO TgtMsg: 262 10
2026-02-02 15:58:52,325 INFO TgtMsg: 272 10
2026-02-02 15:58:52,490 INFO TgtMsg: 282 10
2026-02-02 15:58:52,647 INFO TgtMsg: 292 10
2026-02-02 15:58:52,769 DEBUG [MOCK] Message B9: counter at 300
2026-02-02 15:58:52,809 INFO TgtMsg: 302 10
2026-02-02 15:58:52,968 INFO TgtMsg: 312 10
2026-02-02 15:58:53,123 INFO TgtMsg: 322 10
2026-02-02 15:58:53,288 INFO TgtMsg: 332 10
2026-02-02 15:58:53,444 INFO TgtMsg: 342 10
2026-02-02 15:58:53,601 INFO TgtMsg: 352 10
2026-02-02 15:58:53,759 INFO TgtMsg: 362 10
2026-02-02 15:58:53,917 INFO TgtMsg: 372 10
2026-02-02 15:58:54,083 INFO TgtMsg: 382 10
2026-02-02 15:58:54,244 INFO TgtMsg: 392 10
2026-02-02 15:58:54,378 DEBUG [MOCK] Message B9: counter at 400
2026-02-02 15:58:54,408 INFO TgtMsg: 402 10
2026-02-02 15:58:54,565 INFO TgtMsg: 412 10
2026-02-02 15:58:54,724 INFO TgtMsg: 422 10
2026-02-02 15:58:54,894 INFO TgtMsg: 432 10
2026-02-02 15:58:55,046 INFO TgtMsg: 442 10
2026-02-02 15:58:55,202 INFO TgtMsg: 452 10
2026-02-02 15:58:55,358 INFO TgtMsg: 462 10
2026-02-02 15:58:55,516 INFO TgtMsg: 472 10
2026-02-02 15:58:55,672 INFO TgtMsg: 482 10
2026-02-02 15:58:55,836 INFO TgtMsg: 492 10
2026-02-02 15:58:55,957 DEBUG [MOCK] Message B9: counter at 500
2026-02-02 15:58:55,973 INFO Target NOT detected (timeout after 7.99s)
2026-02-02 15:58:55,973 WARNING [Run 2] Target NOT DETECTED (timeout: 7.99s)
2026-02-02 15:58:55,974 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3
Total Step 190: Success 186 (97.89%), Failed 4 (2.11%),
2026-02-02 15:58:55,974 INFO Repetition 3 of 3
2026-02-02 15:58:55,974 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:58:55,974 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:58:56,986 INFO Set MAIN_POWER to False
2026-02-02 15:58:56,986 INFO [MOCK] Power OFF
2026-02-02 15:58:56,986 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:59:02,001 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:59:02,002 INFO OK: read value = False
2026-02-02 15:59:06,002 INFO The test operator is required to switch on the target.
2026-02-02 15:59:06,004 INFO Set MAIN_POWER to True
2026-02-02 15:59:06,005 INFO [MOCK] Power ON
2026-02-02 15:59:06,007 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:59:06,007 INFO run_count = 3
2026-02-02 15:59:06,007 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:59:06,007 INFO current_scenario = 'mixed'
2026-02-02 15:59:06,007 INFO _scenario_list = ['random_failures', 'transmitter_fail', 'normal']
2026-02-02 15:59:06,008 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:59:06,008 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='normal'
2026-02-02 15:59:06,008 INFO [DEBUG] About to call _log_scenario_info('normal', 3, 3)
2026-02-02 15:59:06,008 INFO
2026-02-02 15:59:06,008 INFO ####################################################################################################
2026-02-02 15:59:06,008 INFO ####################################################################################################
2026-02-02 15:59:06,008 INFO ### RUN 3/3: NORMAL OPERATION
2026-02-02 15:59:06,009 INFO ####################################################################################################
2026-02-02 15:59:06,009 INFO
2026-02-02 15:59:06,009 INFO SCENARIO: normal
2026-02-02 15:59:06,009 INFO DESCRIPTION: All systems operational - no failures
2026-02-02 15:59:06,009 INFO
2026-02-02 15:59:06,009 INFO EXPECTED FAILURES:
2026-02-02 15:59:06,009 INFO (none)
2026-02-02 15:59:06,010 INFO
2026-02-02 15:59:06,010 INFO EXPECTED PASSES:
2026-02-02 15:59:06,010 INFO ✓ All B6 status fields (except pedestal)
2026-02-02 15:59:06,010 INFO ✓ All B8 diagnostic fields
2026-02-02 15:59:06,010 INFO ✓ Target generation
2026-02-02 15:59:06,010 INFO
2026-02-02 15:59:06,012 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present)
2026-02-02 15:59:06,012 INFO
2026-02-02 15:59:06,012 INFO ####################################################################################################
2026-02-02 15:59:06,012 INFO ####################################################################################################
2026-02-02 15:59:06,012 INFO
2026-02-02 15:59:06,012 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:59:06,012 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected)
2026-02-02 15:59:06,012 INFO [MOCK] Run 3: Target will be VISIBLE (pattern index 2)
2026-02-02 15:59:06,012 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3)
2026-02-02 15:59:11,020 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:59:11,021 INFO OK: read value = True
2026-02-02 15:59:11,129 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:59:11,332 INFO [MOCK] BIT report available after 5.3s
2026-02-02 15:59:11,364 INFO BIT report available after 0.2s
2026-02-02 15:59:11,364 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:59:11,364 INFO OK: read value = false
2026-02-02 15:59:11,365 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:59:11,365 WARNING CHECK ERROR: read value = true
2026-02-02 15:59:11,365 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:59:11,365 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:59:11,365 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:59:11,365 INFO OK: read value = false
2026-02-02 15:59:11,366 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:59:11,366 INFO OK: read value = false
2026-02-02 15:59:11,366 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:59:11,366 INFO OK: read value = false
2026-02-02 15:59:11,366 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:59:11,366 INFO OK: read value = false
2026-02-02 15:59:11,366 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:59:11,367 INFO OK: read value = false
2026-02-02 15:59:11,367 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:59:11,367 INFO OK: read value = false
2026-02-02 15:59:11,367 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:59:11,367 INFO OK: read value = false
2026-02-02 15:59:11,367 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:59:11,367 INFO OK: read value = false
2026-02-02 15:59:11,367 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:59:11,368 INFO OK: read value = false
2026-02-02 15:59:11,368 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:59:11,368 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 15:59:11,368 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 15:59:11,368 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 15:59:11,368 INFO [Run 3] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 15:59:11,368 INFO Known failures (HW setup): 2
2026-02-02 15:59:11,368 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 15:59:11,368 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 15:59:11,369 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:59:11,369 INFO OK: read value = false
2026-02-02 15:59:11,369 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:59:11,369 INFO OK: read value = false
2026-02-02 15:59:11,369 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:59:11,369 INFO OK: read value = false
2026-02-02 15:59:11,369 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:59:11,370 INFO OK: read value = false
2026-02-02 15:59:11,370 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:59:11,370 INFO OK: read value = false
2026-02-02 15:59:11,370 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:59:11,370 INFO OK: read value = false
2026-02-02 15:59:11,370 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:59:11,371 INFO OK: read value = false
2026-02-02 15:59:11,371 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:59:11,371 INFO OK: read value = false
2026-02-02 15:59:11,371 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:59:11,371 INFO OK: read value = false
2026-02-02 15:59:11,371 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:59:11,371 WARNING CHECK ERROR: read value = 0
2026-02-02 15:59:11,371 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:59:11,372 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:59:11,372 INFO OK: read value = false
2026-02-02 15:59:11,372 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:59:11,372 INFO OK: read value = false
2026-02-02 15:59:11,372 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:59:11,372 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:59:11,372 INFO OK: read value = false
2026-02-02 15:59:11,372 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:59:11,372 INFO OK: read value = false
2026-02-02 15:59:11,373 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:59:11,373 INFO OK: read value = false
2026-02-02 15:59:11,373 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:59:11,373 INFO OK: read value = false
2026-02-02 15:59:11,373 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:59:11,373 INFO OK: read value = false
2026-02-02 15:59:11,373 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:59:11,374 INFO OK: read value = false
2026-02-02 15:59:11,374 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:59:11,374 INFO OK: read value = false
2026-02-02 15:59:11,374 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:59:11,374 INFO OK: read value = false
2026-02-02 15:59:11,374 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:59:11,374 INFO OK: read value = false
2026-02-02 15:59:11,374 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:59:11,374 INFO OK: read value = false
2026-02-02 15:59:11,374 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:59:11,375 INFO OK: read value = false
2026-02-02 15:59:11,375 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:59:11,375 INFO OK: read value = false
2026-02-02 15:59:11,375 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:59:11,375 INFO OK: read value = false
2026-02-02 15:59:11,375 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:59:11,375 INFO OK: read value = false
2026-02-02 15:59:11,375 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:59:11,376 INFO OK: read value = false
2026-02-02 15:59:11,376 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:59:11,376 INFO OK: read value = false
2026-02-02 15:59:11,376 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:59:11,377 INFO OK: read value = false
2026-02-02 15:59:11,377 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:59:11,377 INFO OK: read value = false
2026-02-02 15:59:11,377 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:59:11,377 INFO OK: read value = false
2026-02-02 15:59:11,377 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:59:11,377 INFO OK: read value = false
2026-02-02 15:59:11,377 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:59:11,377 INFO OK: read value = false
2026-02-02 15:59:11,377 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:59:11,377 INFO OK: read value = false
2026-02-02 15:59:11,377 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:59:11,378 INFO OK: read value = false
2026-02-02 15:59:11,378 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:59:11,378 INFO OK: read value = false
2026-02-02 15:59:11,378 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:59:11,378 INFO OK: read value = false
2026-02-02 15:59:11,379 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:59:11,379 INFO OK: read value = false
2026-02-02 15:59:11,379 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:59:11,379 INFO OK: read value = false
2026-02-02 15:59:11,380 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:59:11,380 INFO OK: read value = false
2026-02-02 15:59:11,380 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:59:11,380 INFO OK: read value = false
2026-02-02 15:59:11,380 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:59:11,381 INFO OK: read value = false
2026-02-02 15:59:11,381 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:59:11,381 INFO OK: read value = false
2026-02-02 15:59:11,381 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:59:11,381 INFO OK: read value = false
2026-02-02 15:59:11,382 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:59:11,382 INFO OK: read value = false
2026-02-02 15:59:11,382 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:59:11,382 INFO OK: read value = false
2026-02-02 15:59:11,382 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:59:11,382 INFO OK: read value = false
2026-02-02 15:59:11,383 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:59:11,384 INFO OK: read value = false
2026-02-02 15:59:11,384 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:59:11,384 INFO OK: read value = false
2026-02-02 15:59:11,384 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:59:11,384 INFO OK: read value = false
2026-02-02 15:59:11,385 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:59:11,385 INFO OK: read value = false
2026-02-02 15:59:11,385 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:59:11,386 INFO OK: read value = false
2026-02-02 15:59:11,386 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:59:11,387 INFO OK: read value = false
2026-02-02 15:59:11,387 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:59:11,387 INFO OK: read value = false
2026-02-02 15:59:11,387 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:59:11,388 INFO OK: read value = false
2026-02-02 15:59:11,388 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:59:11,388 INFO OK: read value = false
2026-02-02 15:59:11,388 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:59:11,389 INFO OK: read value = false
2026-02-02 15:59:11,389 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:59:11,389 INFO OK: read value = false
2026-02-02 15:59:11,389 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:59:11,389 INFO OK: read value = false
2026-02-02 15:59:11,390 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:59:11,390 INFO OK: read value = false
2026-02-02 15:59:11,390 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:59:11,390 INFO OK: read value = false
2026-02-02 15:59:11,390 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:59:11,390 INFO OK: read value = false
2026-02-02 15:59:11,390 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:59:11,391 INFO OK: read value = false
2026-02-02 15:59:11,391 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:59:11,391 INFO OK: read value = false
2026-02-02 15:59:11,391 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:59:11,391 INFO OK: read value = false
2026-02-02 15:59:11,391 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:59:11,391 INFO OK: read value = false
2026-02-02 15:59:11,392 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:59:11,392 INFO OK: read value = false
2026-02-02 15:59:11,392 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:59:11,393 INFO OK: read value = false
2026-02-02 15:59:11,393 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:59:11,393 INFO OK: read value = false
2026-02-02 15:59:11,394 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:59:11,396 INFO OK: read value = false
2026-02-02 15:59:11,396 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:59:11,396 INFO OK: read value = false
2026-02-02 15:59:11,396 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:59:11,396 INFO OK: read value = false
2026-02-02 15:59:11,398 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:59:11,398 INFO OK: read value = false
2026-02-02 15:59:11,398 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:59:11,398 INFO OK: read value = false
2026-02-02 15:59:11,398 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:59:11,398 INFO OK: read value = false
2026-02-02 15:59:11,399 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:59:11,399 INFO OK: read value = false
2026-02-02 15:59:11,399 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:59:11,399 INFO OK: read value = false
2026-02-02 15:59:11,399 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:59:11,400 INFO OK: read value = false
2026-02-02 15:59:11,400 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:59:11,400 INFO OK: read value = false
2026-02-02 15:59:11,400 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:59:11,400 INFO OK: read value = false
2026-02-02 15:59:11,400 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:59:11,400 INFO OK: read value = false
2026-02-02 15:59:11,400 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:59:11,401 INFO OK: read value = false
2026-02-02 15:59:11,401 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:59:11,401 INFO OK: read value = false
2026-02-02 15:59:11,401 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:59:11,401 INFO OK: read value = false
2026-02-02 15:59:11,401 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:59:11,401 INFO OK: read value = false
2026-02-02 15:59:11,401 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:59:11,401 INFO OK: read value = false
2026-02-02 15:59:11,401 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:59:11,402 INFO OK: read value = false
2026-02-02 15:59:11,402 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:59:11,402 INFO OK: read value = false
2026-02-02 15:59:11,402 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:59:11,402 INFO OK: read value = false
2026-02-02 15:59:11,402 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:59:11,402 INFO OK: read value = false
2026-02-02 15:59:11,402 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:59:11,402 INFO OK: read value = false
2026-02-02 15:59:11,403 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:59:11,403 INFO OK: read value = false
2026-02-02 15:59:11,403 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:59:11,403 INFO OK: read value = false
2026-02-02 15:59:11,403 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:59:11,404 INFO OK: read value = false
2026-02-02 15:59:11,404 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:59:11,404 INFO OK: read value = false
2026-02-02 15:59:11,404 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:59:11,404 INFO OK: read value = false
2026-02-02 15:59:11,404 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:59:11,405 INFO OK: read value = false
2026-02-02 15:59:11,405 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:59:11,406 INFO OK: read value = false
2026-02-02 15:59:11,406 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:59:11,406 INFO OK: read value = false
2026-02-02 15:59:11,406 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:59:11,406 INFO OK: read value = false
2026-02-02 15:59:11,406 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:59:11,406 INFO OK: read value = false
2026-02-02 15:59:11,406 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:59:11,407 INFO OK: read value = false
2026-02-02 15:59:11,409 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:59:11,410 INFO OK: read value = false
2026-02-02 15:59:11,410 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:59:11,410 INFO OK: read value = false
2026-02-02 15:59:11,410 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:59:11,411 INFO OK: read value = false
2026-02-02 15:59:11,411 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:59:11,411 INFO OK: read value = false
2026-02-02 15:59:11,411 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:59:11,411 INFO OK: read value = false
2026-02-02 15:59:11,411 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:59:11,412 INFO OK: read value = false
2026-02-02 15:59:11,412 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:59:11,412 INFO OK: read value = false
2026-02-02 15:59:11,412 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:59:11,412 INFO OK: read value = false
2026-02-02 15:59:11,413 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:59:11,413 INFO OK: read value = false
2026-02-02 15:59:11,413 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:59:11,413 INFO OK: read value = false
2026-02-02 15:59:11,413 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:59:11,414 INFO OK: read value = false
2026-02-02 15:59:11,414 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:59:11,414 INFO OK: read value = false
2026-02-02 15:59:11,414 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:59:11,414 INFO OK: read value = false
2026-02-02 15:59:11,414 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:59:11,415 INFO OK: read value = false
2026-02-02 15:59:11,415 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:59:11,415 INFO OK: read value = false
2026-02-02 15:59:11,415 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:59:11,415 INFO OK: read value = false
2026-02-02 15:59:11,416 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:59:11,416 INFO OK: read value = false
2026-02-02 15:59:11,416 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:59:11,416 INFO OK: read value = false
2026-02-02 15:59:11,417 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:59:11,417 INFO OK: read value = false
2026-02-02 15:59:11,418 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:59:11,418 INFO OK: read value = false
2026-02-02 15:59:11,419 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:59:11,419 INFO OK: read value = false
2026-02-02 15:59:11,419 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:59:11,420 INFO OK: read value = false
2026-02-02 15:59:11,420 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:59:11,420 INFO OK: read value = false
2026-02-02 15:59:11,421 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:59:11,421 INFO OK: read value = false
2026-02-02 15:59:11,422 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:59:11,422 INFO OK: read value = false
2026-02-02 15:59:11,422 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:59:11,423 INFO OK: read value = false
2026-02-02 15:59:11,423 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:59:11,423 INFO OK: read value = false
2026-02-02 15:59:11,423 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:59:11,424 INFO OK: read value = false
2026-02-02 15:59:11,424 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:59:11,424 INFO OK: read value = false
2026-02-02 15:59:11,424 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:59:11,424 INFO OK: read value = false
2026-02-02 15:59:11,425 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:59:11,425 INFO OK: read value = false
2026-02-02 15:59:11,425 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:59:11,425 INFO OK: read value = false
2026-02-02 15:59:11,425 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:59:11,426 INFO OK: read value = false
2026-02-02 15:59:11,426 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:59:11,426 INFO OK: read value = false
2026-02-02 15:59:11,426 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:59:11,426 INFO OK: read value = false
2026-02-02 15:59:11,426 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:59:11,427 INFO OK: read value = false
2026-02-02 15:59:11,427 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:59:11,427 INFO OK: read value = false
2026-02-02 15:59:11,427 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:59:11,427 INFO OK: read value = false
2026-02-02 15:59:11,427 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:59:11,427 INFO OK: read value = false
2026-02-02 15:59:11,428 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:59:11,428 INFO OK: read value = false
2026-02-02 15:59:11,428 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:59:11,429 INFO OK: read value = false
2026-02-02 15:59:11,429 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:59:11,429 INFO OK: read value = false
2026-02-02 15:59:11,429 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:59:11,429 INFO OK: read value = false
2026-02-02 15:59:11,429 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:59:11,429 INFO OK: read value = false
2026-02-02 15:59:11,430 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:59:11,430 INFO OK: read value = false
2026-02-02 15:59:11,430 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:59:11,430 INFO OK: read value = false
2026-02-02 15:59:11,431 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:59:11,431 INFO OK: read value = false
2026-02-02 15:59:11,431 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:59:11,431 INFO OK: read value = false
2026-02-02 15:59:11,431 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:59:11,431 INFO OK: read value = false
2026-02-02 15:59:11,431 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:59:11,431 INFO OK: read value = false
2026-02-02 15:59:11,432 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:59:11,432 INFO OK: read value = false
2026-02-02 15:59:11,432 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:59:11,432 INFO OK: read value = false
2026-02-02 15:59:11,433 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:59:11,433 INFO OK: read value = false
2026-02-02 15:59:11,434 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:59:11,434 INFO OK: read value = false
2026-02-02 15:59:11,434 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:59:11,435 INFO OK: read value = false
2026-02-02 15:59:11,435 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:59:11,435 INFO OK: read value = false
2026-02-02 15:59:11,435 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:59:11,435 INFO OK: read value = false
2026-02-02 15:59:11,435 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:59:11,436 INFO OK: read value = false
2026-02-02 15:59:11,436 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:59:11,436 INFO OK: read value = false
2026-02-02 15:59:11,437 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:59:11,437 INFO OK: read value = false
2026-02-02 15:59:11,437 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:59:11,438 INFO OK: read value = false
2026-02-02 15:59:11,438 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:59:11,438 INFO OK: read value = false
2026-02-02 15:59:11,438 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:59:11,439 INFO OK: read value = false
2026-02-02 15:59:11,439 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:59:11,439 INFO OK: read value = false
2026-02-02 15:59:11,440 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:59:11,440 INFO OK: read value = false
2026-02-02 15:59:11,440 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:59:11,440 INFO OK: read value = false
2026-02-02 15:59:11,440 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:59:11,440 INFO OK: read value = false
2026-02-02 15:59:11,441 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:59:11,441 INFO OK: read value = false
2026-02-02 15:59:11,441 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:59:11,441 INFO OK: read value = false
2026-02-02 15:59:11,441 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:59:11,441 INFO OK: read value = false
2026-02-02 15:59:11,441 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:59:11,442 INFO OK: read value = false
2026-02-02 15:59:11,442 INFO [Run 3] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:59:11,442 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:59:11,442 INFO 0.0s remaining ...
2026-02-02 15:59:11,442 INFO [Run 3] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 15:59:11,443 INFO Target Detection Test
2026-02-02 15:59:11,443 INFO [Run 3] Starting target detection test (timeout: 5.0s)
2026-02-02 15:59:11,443 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:59:11,458 INFO TgtMsg: 502 502
2026-02-02 15:59:11,458 INFO Tgt: 1 @ 1180
2026-02-02 15:59:11,458 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:59:11,458 INFO OK: read value = 1
2026-02-02 15:59:11,458 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:59:11,459 INFO OK: read value = 1180
2026-02-02 15:59:11,459 INFO Target detected successfully in 0.02s
2026-02-02 15:59:11,459 INFO [Run 3] Target DETECTED in 0.02s
2026-02-02 15:59:11,459 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3
Total Step 192: Success 189 (98.44%), Failed 3 (1.56%),
2026-02-02 15:59:11,459 INFO Repetitions terminated.
2026-02-02 15:59:11,460 INFO [Report] Custom statistics data registered for PDF generation
2026-02-02 15:59:11,460 INFO ==========================================================================================
2026-02-02 15:59:11,460 INFO FINAL TEST STATISTICS SUMMARY
2026-02-02 15:59:11,460 INFO ==========================================================================================
2026-02-02 15:59:11,461 INFO Total Runs: 3
2026-02-02 15:59:11,461 INFO Successful: 2 (66.7%)
2026-02-02 15:59:11,461 INFO Failed: 1 (33.3%)
2026-02-02 15:59:11,461 INFO B6 Checks: 36 (Pass: 29, Fail: 2, Known: 5)
2026-02-02 15:59:11,462 INFO B8 Checks: 519 (Pass: 516, Fail: 3)
2026-02-02 15:59:11,462 INFO Serial: 0 messages (0 errors, 0 fatal, 0 recycles)
2026-02-02 15:59:11,463 INFO Target: 2 detected, 1 not detected (66.7% pass rate)
2026-02-02 15:59:11,463 INFO PBIT Timing: avg=0.24s, min=0.23s, max=0.24s, σ=0.00s
2026-02-02 15:59:11,463 INFO ==========================================================================================
2026-02-02 15:59:11,463 INFO Detailed statistics will be available in the PDF report
2026-02-02 15:59:11,463 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_155911_statistics.csv
2026-02-02 15:59:11,471 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_155911_statistics.csv
2026-02-02 15:59:11,472 INFO Statistics exported successfully to JSON: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_155911_statistics.json
2026-02-02 15:59:11,474 INFO Set MAIN_POWER to False
2026-02-02 15:59:11,474 INFO [MOCK] Power OFF
2026-02-02 15:59:11,474 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:59:16,486 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:59:16,486 INFO OK: read value = False
2026-02-02 15:59:16,487 INFO [MOCK] Serial terminal disconnected
2026-02-02 15:59:16,487 INFO Stop Time: 2026-02-02 15:58:16.770414
2026-02-02 15:59:16,487 INFO Test execution time: 0:00:59.717377