2026-02-02 15:28:08,464 INFO Start Time: 2026-02-02 15:28:08.463987
2026-02-02 15:28:08,464 INFO [MOCK] Serial terminal initialized
2026-02-02 15:28:08,464 INFO [MOCK] Serial terminal connected
2026-02-02 15:28:08,464 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:28:08,465 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-02-02 15:28:08,465 INFO [MOCK] Simulating target acquisition: will appear after 6 scan cycles
2026-02-02 15:28:08,475 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:28:08,525 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:28:08,576 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:28:08,627 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:28:08,677 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:28:08,728 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:28:08,779 INFO [MOCK] Target simulated at distance 1180
2026-02-02 15:28:08,779 INFO [MOCK] Log started at level 3 in directory: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts
2026-02-02 15:28:08,780 INFO tgt_gen_alone(): 0
2026-02-02 15:28:08,780 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:28:08,790 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:28:08,790 INFO TgtMsg: 0 0
2026-02-02 15:28:08,791 INFO Tgt: 1 @ 1180
2026-02-02 15:28:08,791 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:28:08,791 INFO OK: read value = 1
2026-02-02 15:28:08,792 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:28:08,792 INFO OK: read value = 1180
2026-02-02 15:28:08,792 INFO [MOCK] Log stopped
2026-02-02 15:28:08,792 INFO Repetition 1 of 3
2026-02-02 15:28:08,792 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:28:08,792 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:28:09,793 INFO Set MAIN_POWER to False
2026-02-02 15:28:09,793 INFO [MOCK] Power OFF
2026-02-02 15:28:09,794 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:28:14,795 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:28:14,796 INFO OK: read value = False
2026-02-02 15:28:18,797 INFO The test operator is required to switch on the target.
2026-02-02 15:28:18,797 INFO Set MAIN_POWER to True
2026-02-02 15:28:18,798 INFO [MOCK] Power ON
2026-02-02 15:28:18,798 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:28:18,799 INFO run_count = 1
2026-02-02 15:28:18,799 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:28:18,799 INFO current_scenario = 'mixed'
2026-02-02 15:28:18,799 INFO _scenario_list = ['recycle_recovery_2', 'normal', 'recycle_recovery_2']
2026-02-02 15:28:18,800 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:28:18,800 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='recycle_recovery_2'
2026-02-02 15:28:18,800 INFO [DEBUG] About to call _log_scenario_info('recycle_recovery_2', 1, 3)
2026-02-02 15:28:18,801 INFO
2026-02-02 15:28:18,801 INFO ####################################################################################################
2026-02-02 15:28:18,801 INFO ####################################################################################################
2026-02-02 15:28:18,801 INFO ### RUN 1/3: RECYCLE SELF-HEALING (2 CYCLES)
2026-02-02 15:28:18,802 INFO ####################################################################################################
2026-02-02 15:28:18,802 INFO
2026-02-02 15:28:18,802 INFO SCENARIO: recycle_recovery_2
2026-02-02 15:28:18,802 INFO DESCRIPTION: Processor fails, then auto-recovers after 2 RECYCLE events
2026-02-02 15:28:18,802 INFO
2026-02-02 15:28:18,802 INFO EXPECTED FAILURES:
2026-02-02 15:28:18,802 INFO ✗ Initial: processor_status = FAIL
2026-02-02 15:28:18,803 INFO ✗ Serial: 2x RECYCLE events detected
2026-02-02 15:28:18,803 INFO
2026-02-02 15:28:18,803 INFO EXPECTED PASSES:
2026-02-02 15:28:18,803 INFO ✓ After 2nd RECYCLE: processor_status = PASS
2026-02-02 15:28:18,803 INFO ✓ Final: All systems OK
2026-02-02 15:28:18,803 INFO
2026-02-02 15:28:18,803 INFO NOTES: Simulates persistent failure requiring multiple recovery attempts
2026-02-02 15:28:18,803 INFO
2026-02-02 15:28:18,804 INFO ####################################################################################################
2026-02-02 15:28:18,804 INFO ####################################################################################################
2026-02-02 15:28:18,804 INFO
2026-02-02 15:28:18,804 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:28:18,804 INFO [MOCK APPLY] ⚠ RECYCLE scenario enabled: 2 cycles to recovery
2026-02-02 15:28:18,804 INFO [MOCK RECYCLE] Initial processor failure detected
2026-02-02 15:28:19,305 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:28:19,306 INFO [MOCK RECYCLE] RECYCLE 1/2
2026-02-02 15:28:19,806 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:28:19,807 INFO [MOCK RECYCLE] RECYCLE 2/2
2026-02-02 15:28:20,108 INFO [MOCK RECYCLE] System recovered after 2 RECYCLEs (slower self-healing)
2026-02-02 15:28:20,108 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1)
2026-02-02 15:28:25,109 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:28:25,111 INFO OK: read value = True
2026-02-02 15:28:25,212 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:28:25,413 INFO [MOCK] BIT report available after 6.6s
2026-02-02 15:28:25,433 INFO BIT report available after 0.2s
2026-02-02 15:28:25,434 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:28:25,434 INFO OK: read value = false
2026-02-02 15:28:25,434 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:28:25,434 WARNING CHECK ERROR: read value = true
2026-02-02 15:28:25,434 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:28:25,434 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:28:25,435 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:28:25,435 INFO OK: read value = false
2026-02-02 15:28:25,435 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:28:25,435 INFO OK: read value = false
2026-02-02 15:28:25,435 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:28:25,435 INFO OK: read value = false
2026-02-02 15:28:25,435 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:28:25,435 INFO OK: read value = false
2026-02-02 15:28:25,435 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:28:25,435 INFO OK: read value = false
2026-02-02 15:28:25,436 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:28:25,436 INFO OK: read value = false
2026-02-02 15:28:25,436 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:28:25,436 INFO OK: read value = false
2026-02-02 15:28:25,436 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:28:25,436 INFO OK: read value = false
2026-02-02 15:28:25,436 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:28:25,436 INFO OK: read value = false
2026-02-02 15:28:25,436 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:28:25,436 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 15:28:25,436 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 15:28:25,437 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 15:28:25,437 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 15:28:25,437 INFO Known failures (HW setup): 2
2026-02-02 15:28:25,437 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 15:28:25,437 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 15:28:25,437 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:28:25,437 INFO OK: read value = false
2026-02-02 15:28:25,437 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:28:25,438 INFO OK: read value = false
2026-02-02 15:28:25,438 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:28:25,438 INFO OK: read value = false
2026-02-02 15:28:25,438 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:28:25,439 INFO OK: read value = false
2026-02-02 15:28:25,439 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:28:25,439 INFO OK: read value = false
2026-02-02 15:28:25,439 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:28:25,439 INFO OK: read value = false
2026-02-02 15:28:25,439 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:28:25,440 INFO OK: read value = false
2026-02-02 15:28:25,440 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:28:25,440 INFO OK: read value = false
2026-02-02 15:28:25,440 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:28:25,440 INFO OK: read value = false
2026-02-02 15:28:25,441 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:28:25,441 WARNING CHECK ERROR: read value = 0
2026-02-02 15:28:25,441 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:28:25,441 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:28:25,441 INFO OK: read value = false
2026-02-02 15:28:25,441 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:28:25,441 INFO OK: read value = false
2026-02-02 15:28:25,441 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:28:25,441 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:28:25,442 INFO OK: read value = false
2026-02-02 15:28:25,442 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:28:25,442 INFO OK: read value = false
2026-02-02 15:28:25,442 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:28:25,442 INFO OK: read value = false
2026-02-02 15:28:25,442 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:28:25,442 INFO OK: read value = false
2026-02-02 15:28:25,442 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:28:25,443 INFO OK: read value = false
2026-02-02 15:28:25,443 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:28:25,443 INFO OK: read value = false
2026-02-02 15:28:25,443 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:28:25,443 INFO OK: read value = false
2026-02-02 15:28:25,443 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:28:25,443 INFO OK: read value = false
2026-02-02 15:28:25,443 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:28:25,443 INFO OK: read value = false
2026-02-02 15:28:25,443 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:28:25,444 INFO OK: read value = false
2026-02-02 15:28:25,444 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:28:25,444 INFO OK: read value = false
2026-02-02 15:28:25,444 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:28:25,444 INFO OK: read value = false
2026-02-02 15:28:25,444 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:28:25,444 INFO OK: read value = false
2026-02-02 15:28:25,444 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:28:25,445 INFO OK: read value = false
2026-02-02 15:28:25,445 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:28:25,445 INFO OK: read value = false
2026-02-02 15:28:25,445 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:28:25,445 INFO OK: read value = false
2026-02-02 15:28:25,445 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:28:25,445 INFO OK: read value = false
2026-02-02 15:28:25,445 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:28:25,445 INFO OK: read value = false
2026-02-02 15:28:25,446 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:28:25,446 INFO OK: read value = false
2026-02-02 15:28:25,446 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:28:25,446 INFO OK: read value = false
2026-02-02 15:28:25,446 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:28:25,446 INFO OK: read value = false
2026-02-02 15:28:25,446 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:28:25,446 INFO OK: read value = false
2026-02-02 15:28:25,446 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:28:25,447 INFO OK: read value = false
2026-02-02 15:28:25,447 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:28:25,447 INFO OK: read value = false
2026-02-02 15:28:25,447 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:28:25,447 INFO OK: read value = false
2026-02-02 15:28:25,447 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:28:25,447 INFO OK: read value = false
2026-02-02 15:28:25,447 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:28:25,448 INFO OK: read value = false
2026-02-02 15:28:25,448 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:28:25,448 INFO OK: read value = false
2026-02-02 15:28:25,448 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:28:25,448 INFO OK: read value = false
2026-02-02 15:28:25,448 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:28:25,448 INFO OK: read value = false
2026-02-02 15:28:25,448 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:28:25,448 INFO OK: read value = false
2026-02-02 15:28:25,448 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:28:25,448 INFO OK: read value = false
2026-02-02 15:28:25,449 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:28:25,449 INFO OK: read value = false
2026-02-02 15:28:25,449 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:28:25,449 INFO OK: read value = false
2026-02-02 15:28:25,449 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:28:25,449 INFO OK: read value = false
2026-02-02 15:28:25,449 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:28:25,449 INFO OK: read value = false
2026-02-02 15:28:25,449 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:28:25,449 INFO OK: read value = false
2026-02-02 15:28:25,450 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:28:25,450 INFO OK: read value = false
2026-02-02 15:28:25,450 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:28:25,450 INFO OK: read value = false
2026-02-02 15:28:25,450 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:28:25,450 INFO OK: read value = false
2026-02-02 15:28:25,450 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:28:25,450 INFO OK: read value = false
2026-02-02 15:28:25,451 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:28:25,451 INFO OK: read value = false
2026-02-02 15:28:25,451 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:28:25,451 INFO OK: read value = false
2026-02-02 15:28:25,451 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:28:25,451 INFO OK: read value = false
2026-02-02 15:28:25,451 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:28:25,451 INFO OK: read value = false
2026-02-02 15:28:25,452 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:28:25,452 INFO OK: read value = false
2026-02-02 15:28:25,452 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:28:25,452 INFO OK: read value = false
2026-02-02 15:28:25,452 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:28:25,452 INFO OK: read value = false
2026-02-02 15:28:25,452 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:28:25,452 INFO OK: read value = false
2026-02-02 15:28:25,452 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:28:25,453 INFO OK: read value = false
2026-02-02 15:28:25,453 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:28:25,453 INFO OK: read value = false
2026-02-02 15:28:25,453 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:28:25,453 INFO OK: read value = false
2026-02-02 15:28:25,453 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:28:25,453 INFO OK: read value = false
2026-02-02 15:28:25,454 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:28:25,454 INFO OK: read value = false
2026-02-02 15:28:25,454 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:28:25,454 INFO OK: read value = false
2026-02-02 15:28:25,454 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:28:25,457 INFO OK: read value = false
2026-02-02 15:28:25,458 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:28:25,458 INFO OK: read value = false
2026-02-02 15:28:25,458 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:28:25,458 INFO OK: read value = false
2026-02-02 15:28:25,458 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:28:25,458 INFO OK: read value = false
2026-02-02 15:28:25,462 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:28:25,462 INFO OK: read value = false
2026-02-02 15:28:25,462 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:28:25,462 INFO OK: read value = false
2026-02-02 15:28:25,462 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:28:25,463 INFO OK: read value = false
2026-02-02 15:28:25,463 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:28:25,463 INFO OK: read value = false
2026-02-02 15:28:25,463 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:28:25,464 INFO OK: read value = false
2026-02-02 15:28:25,464 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:28:25,464 INFO OK: read value = false
2026-02-02 15:28:25,464 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:28:25,464 INFO OK: read value = false
2026-02-02 15:28:25,464 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:28:25,464 INFO OK: read value = false
2026-02-02 15:28:25,464 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:28:25,465 INFO OK: read value = false
2026-02-02 15:28:25,465 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:28:25,465 INFO OK: read value = false
2026-02-02 15:28:25,465 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:28:25,465 INFO OK: read value = false
2026-02-02 15:28:25,465 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:28:25,465 INFO OK: read value = false
2026-02-02 15:28:25,465 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:28:25,466 INFO OK: read value = false
2026-02-02 15:28:25,466 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:28:25,466 INFO OK: read value = false
2026-02-02 15:28:25,466 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:28:25,466 INFO OK: read value = false
2026-02-02 15:28:25,466 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:28:25,467 INFO OK: read value = false
2026-02-02 15:28:25,467 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:28:25,467 INFO OK: read value = false
2026-02-02 15:28:25,467 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:28:25,467 INFO OK: read value = false
2026-02-02 15:28:25,467 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:28:25,468 INFO OK: read value = false
2026-02-02 15:28:25,468 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:28:25,468 INFO OK: read value = false
2026-02-02 15:28:25,468 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:28:25,468 INFO OK: read value = false
2026-02-02 15:28:25,468 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:28:25,468 INFO OK: read value = false
2026-02-02 15:28:25,468 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:28:25,469 INFO OK: read value = false
2026-02-02 15:28:25,469 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:28:25,470 INFO OK: read value = false
2026-02-02 15:28:25,470 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:28:25,470 INFO OK: read value = false
2026-02-02 15:28:25,470 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:28:25,470 INFO OK: read value = false
2026-02-02 15:28:25,471 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:28:25,471 INFO OK: read value = false
2026-02-02 15:28:25,472 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:28:25,473 INFO OK: read value = false
2026-02-02 15:28:25,473 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:28:25,473 INFO OK: read value = false
2026-02-02 15:28:25,473 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:28:25,473 INFO OK: read value = false
2026-02-02 15:28:25,473 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:28:25,473 INFO OK: read value = false
2026-02-02 15:28:25,474 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:28:25,475 INFO OK: read value = false
2026-02-02 15:28:25,475 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:28:25,475 INFO OK: read value = false
2026-02-02 15:28:25,475 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:28:25,475 INFO OK: read value = false
2026-02-02 15:28:25,475 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:28:25,476 INFO OK: read value = false
2026-02-02 15:28:25,476 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:28:25,478 INFO OK: read value = false
2026-02-02 15:28:25,478 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:28:25,478 INFO OK: read value = false
2026-02-02 15:28:25,479 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:28:25,479 INFO OK: read value = false
2026-02-02 15:28:25,479 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:28:25,479 INFO OK: read value = false
2026-02-02 15:28:25,479 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:28:25,480 INFO OK: read value = false
2026-02-02 15:28:25,480 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:28:25,480 INFO OK: read value = false
2026-02-02 15:28:25,480 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:28:25,480 INFO OK: read value = false
2026-02-02 15:28:25,480 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:28:25,481 INFO OK: read value = false
2026-02-02 15:28:25,481 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:28:25,481 INFO OK: read value = false
2026-02-02 15:28:25,483 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:28:25,483 INFO OK: read value = false
2026-02-02 15:28:25,483 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:28:25,484 INFO OK: read value = false
2026-02-02 15:28:25,484 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:28:25,484 INFO OK: read value = false
2026-02-02 15:28:25,484 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:28:25,484 INFO OK: read value = false
2026-02-02 15:28:25,484 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:28:25,484 INFO OK: read value = false
2026-02-02 15:28:25,485 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:28:25,485 INFO OK: read value = false
2026-02-02 15:28:25,485 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:28:25,485 INFO OK: read value = false
2026-02-02 15:28:25,486 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:28:25,486 INFO OK: read value = false
2026-02-02 15:28:25,486 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:28:25,486 INFO OK: read value = false
2026-02-02 15:28:25,487 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:28:25,487 INFO OK: read value = false
2026-02-02 15:28:25,487 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:28:25,488 INFO OK: read value = false
2026-02-02 15:28:25,488 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:28:25,488 INFO OK: read value = false
2026-02-02 15:28:25,488 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:28:25,488 INFO OK: read value = false
2026-02-02 15:28:25,488 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:28:25,488 INFO OK: read value = false
2026-02-02 15:28:25,489 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:28:25,489 INFO OK: read value = false
2026-02-02 15:28:25,489 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:28:25,489 INFO OK: read value = false
2026-02-02 15:28:25,489 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:28:25,489 INFO OK: read value = false
2026-02-02 15:28:25,490 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:28:25,490 INFO OK: read value = false
2026-02-02 15:28:25,490 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:28:25,490 INFO OK: read value = false
2026-02-02 15:28:25,490 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:28:25,490 INFO OK: read value = false
2026-02-02 15:28:25,490 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:28:25,491 INFO OK: read value = false
2026-02-02 15:28:25,491 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:28:25,491 INFO OK: read value = false
2026-02-02 15:28:25,491 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:28:25,491 INFO OK: read value = false
2026-02-02 15:28:25,491 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:28:25,491 INFO OK: read value = false
2026-02-02 15:28:25,491 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:28:25,491 INFO OK: read value = false
2026-02-02 15:28:25,492 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:28:25,492 INFO OK: read value = false
2026-02-02 15:28:25,492 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:28:25,492 INFO OK: read value = false
2026-02-02 15:28:25,492 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:28:25,492 INFO OK: read value = false
2026-02-02 15:28:25,492 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:28:25,492 INFO OK: read value = false
2026-02-02 15:28:25,492 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:28:25,493 INFO OK: read value = false
2026-02-02 15:28:25,493 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:28:25,493 INFO OK: read value = false
2026-02-02 15:28:25,493 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:28:25,493 INFO OK: read value = false
2026-02-02 15:28:25,493 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:28:25,493 INFO OK: read value = false
2026-02-02 15:28:25,493 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:28:25,494 INFO OK: read value = false
2026-02-02 15:28:25,494 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:28:25,494 INFO OK: read value = false
2026-02-02 15:28:25,494 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:28:25,494 INFO OK: read value = false
2026-02-02 15:28:25,494 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:28:25,494 INFO OK: read value = false
2026-02-02 15:28:25,494 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:28:25,495 INFO OK: read value = false
2026-02-02 15:28:25,495 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:28:25,495 INFO OK: read value = false
2026-02-02 15:28:25,495 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:28:25,496 INFO OK: read value = false
2026-02-02 15:28:25,496 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:28:25,496 INFO OK: read value = false
2026-02-02 15:28:25,496 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:28:25,497 INFO OK: read value = false
2026-02-02 15:28:25,497 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:28:25,497 INFO OK: read value = false
2026-02-02 15:28:25,497 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:28:25,497 INFO OK: read value = false
2026-02-02 15:28:25,497 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:28:25,498 INFO OK: read value = false
2026-02-02 15:28:25,498 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:28:25,498 INFO OK: read value = false
2026-02-02 15:28:25,499 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:28:25,499 INFO OK: read value = false
2026-02-02 15:28:25,499 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:28:25,499 INFO OK: read value = false
2026-02-02 15:28:25,500 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:28:25,500 INFO OK: read value = false
2026-02-02 15:28:25,500 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:28:25,500 INFO OK: read value = false
2026-02-02 15:28:25,500 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:28:25,501 INFO OK: read value = false
2026-02-02 15:28:25,501 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:28:25,501 INFO OK: read value = false
2026-02-02 15:28:25,501 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:28:25,502 INFO OK: read value = false
2026-02-02 15:28:25,502 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:28:25,502 INFO OK: read value = false
2026-02-02 15:28:25,502 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:28:25,502 INFO OK: read value = false
2026-02-02 15:28:25,502 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:28:25,503 INFO OK: read value = false
2026-02-02 15:28:25,503 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:28:25,503 INFO OK: read value = false
2026-02-02 15:28:25,503 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:28:25,503 INFO OK: read value = false
2026-02-02 15:28:25,503 INFO [Run 1] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:28:25,503 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:28:25,504 INFO 0.0s remaining ...
2026-02-02 15:28:25,504 INFO [Run 1] Serial: 2 total, 0 errors, 2 fatal, 2 recycles
2026-02-02 15:28:25,504 INFO Target Detection Test
2026-02-02 15:28:25,504 INFO [Run 1] Starting target detection test (timeout: 5.0s)
2026-02-02 15:28:25,505 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:28:25,515 DEBUG [MOCK] Field rng: 1180
2026-02-02 15:28:25,515 INFO TgtMsg: 1 1
2026-02-02 15:28:25,516 INFO Tgt: 1 @ 1180
2026-02-02 15:28:25,516 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:28:25,516 INFO OK: read value = 1
2026-02-02 15:28:25,516 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:28:25,517 INFO OK: read value = 1180
2026-02-02 15:28:25,517 INFO Target detected successfully in 0.01s
2026-02-02 15:28:25,517 INFO [Run 1] Target DETECTED in 0.01s
2026-02-02 15:28:25,517 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3
Total Step 194: Success 191 (98.45%), Failed 3 (1.55%),
2026-02-02 15:28:25,518 INFO Repetition 2 of 3
2026-02-02 15:28:25,518 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:28:25,518 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:28:26,520 INFO Set MAIN_POWER to False
2026-02-02 15:28:26,520 INFO [MOCK] Power OFF
2026-02-02 15:28:26,520 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:28:31,522 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:28:31,522 INFO OK: read value = False
2026-02-02 15:28:35,524 INFO The test operator is required to switch on the target.
2026-02-02 15:28:35,524 INFO Set MAIN_POWER to True
2026-02-02 15:28:35,525 INFO [MOCK] Power ON
2026-02-02 15:28:35,525 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:28:35,525 INFO run_count = 2
2026-02-02 15:28:35,525 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:28:35,525 INFO current_scenario = 'mixed'
2026-02-02 15:28:35,526 INFO _scenario_list = ['recycle_recovery_2', 'normal', 'recycle_recovery_2']
2026-02-02 15:28:35,526 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:28:35,526 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='normal'
2026-02-02 15:28:35,526 INFO [DEBUG] About to call _log_scenario_info('normal', 2, 3)
2026-02-02 15:28:35,526 INFO
2026-02-02 15:28:35,526 INFO ####################################################################################################
2026-02-02 15:28:35,527 INFO ####################################################################################################
2026-02-02 15:28:35,527 INFO ### RUN 2/3: NORMAL OPERATION
2026-02-02 15:28:35,527 INFO ####################################################################################################
2026-02-02 15:28:35,527 INFO
2026-02-02 15:28:35,527 INFO SCENARIO: normal
2026-02-02 15:28:35,528 INFO DESCRIPTION: All systems operational - no failures
2026-02-02 15:28:35,528 INFO
2026-02-02 15:28:35,528 INFO EXPECTED FAILURES:
2026-02-02 15:28:35,528 INFO (none)
2026-02-02 15:28:35,528 INFO
2026-02-02 15:28:35,528 INFO EXPECTED PASSES:
2026-02-02 15:28:35,529 INFO ✓ All B6 status fields (except pedestal)
2026-02-02 15:28:35,529 INFO ✓ All B8 diagnostic fields
2026-02-02 15:28:35,529 INFO ✓ Target generation
2026-02-02 15:28:35,529 INFO
2026-02-02 15:28:35,531 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present)
2026-02-02 15:28:35,531 INFO
2026-02-02 15:28:35,531 INFO ####################################################################################################
2026-02-02 15:28:35,531 INFO ####################################################################################################
2026-02-02 15:28:35,532 INFO
2026-02-02 15:28:35,532 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:28:35,532 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected)
2026-02-02 15:28:35,532 INFO [MOCK RECYCLE] Initial processor failure detected
2026-02-02 15:28:36,033 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:28:36,034 INFO [MOCK RECYCLE] RECYCLE 1/2
2026-02-02 15:28:36,535 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:28:36,535 INFO [MOCK RECYCLE] RECYCLE 2/2
2026-02-02 15:28:36,837 INFO [MOCK RECYCLE] System recovered after 2 RECYCLEs (slower self-healing)
2026-02-02 15:28:36,837 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-02-02 15:28:41,838 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:28:41,839 INFO OK: read value = True
2026-02-02 15:28:41,939 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:28:42,140 INFO [MOCK] BIT report available after 6.6s
2026-02-02 15:28:42,161 INFO BIT report available after 0.2s
2026-02-02 15:28:42,162 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:28:42,162 INFO OK: read value = false
2026-02-02 15:28:42,162 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:28:42,162 WARNING CHECK ERROR: read value = true
2026-02-02 15:28:42,162 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:28:42,163 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:28:42,163 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:28:42,163 INFO OK: read value = false
2026-02-02 15:28:42,163 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:28:42,164 INFO OK: read value = false
2026-02-02 15:28:42,164 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:28:42,164 INFO OK: read value = false
2026-02-02 15:28:42,164 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:28:42,164 INFO OK: read value = false
2026-02-02 15:28:42,165 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:28:42,165 INFO OK: read value = false
2026-02-02 15:28:42,165 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:28:42,165 INFO OK: read value = false
2026-02-02 15:28:42,165 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:28:42,165 INFO OK: read value = false
2026-02-02 15:28:42,165 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:28:42,166 INFO OK: read value = false
2026-02-02 15:28:42,166 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:28:42,166 INFO OK: read value = false
2026-02-02 15:28:42,166 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:28:42,166 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 15:28:42,167 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 15:28:42,167 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 15:28:42,167 INFO [Run 2] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 15:28:42,168 INFO Known failures (HW setup): 2
2026-02-02 15:28:42,168 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 15:28:42,168 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 15:28:42,168 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:28:42,168 INFO OK: read value = false
2026-02-02 15:28:42,169 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:28:42,169 INFO OK: read value = false
2026-02-02 15:28:42,169 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:28:42,169 INFO OK: read value = false
2026-02-02 15:28:42,169 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:28:42,170 INFO OK: read value = false
2026-02-02 15:28:42,170 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:28:42,170 INFO OK: read value = false
2026-02-02 15:28:42,170 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:28:42,170 INFO OK: read value = false
2026-02-02 15:28:42,170 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:28:42,170 INFO OK: read value = false
2026-02-02 15:28:42,171 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:28:42,171 INFO OK: read value = false
2026-02-02 15:28:42,171 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:28:42,171 INFO OK: read value = false
2026-02-02 15:28:42,171 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:28:42,171 WARNING CHECK ERROR: read value = 0
2026-02-02 15:28:42,171 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:28:42,172 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:28:42,172 INFO OK: read value = false
2026-02-02 15:28:42,172 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:28:42,173 INFO OK: read value = false
2026-02-02 15:28:42,173 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:28:42,173 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:28:42,173 INFO OK: read value = false
2026-02-02 15:28:42,174 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:28:42,174 INFO OK: read value = false
2026-02-02 15:28:42,174 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:28:42,174 INFO OK: read value = false
2026-02-02 15:28:42,175 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:28:42,176 INFO OK: read value = false
2026-02-02 15:28:42,176 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:28:42,176 INFO OK: read value = false
2026-02-02 15:28:42,176 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:28:42,178 INFO OK: read value = false
2026-02-02 15:28:42,179 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:28:42,179 INFO OK: read value = false
2026-02-02 15:28:42,179 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:28:42,179 INFO OK: read value = false
2026-02-02 15:28:42,180 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:28:42,180 INFO OK: read value = false
2026-02-02 15:28:42,180 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:28:42,180 INFO OK: read value = false
2026-02-02 15:28:42,181 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:28:42,181 INFO OK: read value = false
2026-02-02 15:28:42,181 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:28:42,181 INFO OK: read value = false
2026-02-02 15:28:42,181 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:28:42,181 INFO OK: read value = false
2026-02-02 15:28:42,182 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:28:42,182 INFO OK: read value = false
2026-02-02 15:28:42,182 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:28:42,183 INFO OK: read value = false
2026-02-02 15:28:42,183 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:28:42,184 INFO OK: read value = false
2026-02-02 15:28:42,184 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:28:42,184 INFO OK: read value = false
2026-02-02 15:28:42,185 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:28:42,185 INFO OK: read value = false
2026-02-02 15:28:42,185 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:28:42,186 INFO OK: read value = false
2026-02-02 15:28:42,186 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:28:42,186 INFO OK: read value = false
2026-02-02 15:28:42,186 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:28:42,186 INFO OK: read value = false
2026-02-02 15:28:42,188 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:28:42,188 INFO OK: read value = false
2026-02-02 15:28:42,188 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:28:42,188 INFO OK: read value = false
2026-02-02 15:28:42,189 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:28:42,189 INFO OK: read value = false
2026-02-02 15:28:42,189 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:28:42,190 INFO OK: read value = false
2026-02-02 15:28:42,190 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:28:42,190 INFO OK: read value = false
2026-02-02 15:28:42,191 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:28:42,191 INFO OK: read value = false
2026-02-02 15:28:42,191 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:28:42,192 INFO OK: read value = false
2026-02-02 15:28:42,192 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:28:42,192 INFO OK: read value = false
2026-02-02 15:28:42,192 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:28:42,192 INFO OK: read value = false
2026-02-02 15:28:42,193 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:28:42,193 INFO OK: read value = false
2026-02-02 15:28:42,193 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:28:42,193 INFO OK: read value = false
2026-02-02 15:28:42,193 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:28:42,193 INFO OK: read value = false
2026-02-02 15:28:42,193 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:28:42,194 INFO OK: read value = false
2026-02-02 15:28:42,194 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:28:42,194 INFO OK: read value = false
2026-02-02 15:28:42,194 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:28:42,195 INFO OK: read value = false
2026-02-02 15:28:42,195 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:28:42,195 INFO OK: read value = false
2026-02-02 15:28:42,195 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:28:42,195 INFO OK: read value = false
2026-02-02 15:28:42,196 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:28:42,196 INFO OK: read value = false
2026-02-02 15:28:42,196 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:28:42,196 INFO OK: read value = false
2026-02-02 15:28:42,197 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:28:42,197 INFO OK: read value = false
2026-02-02 15:28:42,197 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:28:42,197 INFO OK: read value = false
2026-02-02 15:28:42,197 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:28:42,198 INFO OK: read value = false
2026-02-02 15:28:42,198 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:28:42,198 INFO OK: read value = false
2026-02-02 15:28:42,198 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:28:42,198 INFO OK: read value = false
2026-02-02 15:28:42,198 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:28:42,199 INFO OK: read value = false
2026-02-02 15:28:42,199 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:28:42,199 INFO OK: read value = false
2026-02-02 15:28:42,199 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:28:42,200 INFO OK: read value = false
2026-02-02 15:28:42,200 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:28:42,200 INFO OK: read value = false
2026-02-02 15:28:42,200 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:28:42,200 INFO OK: read value = false
2026-02-02 15:28:42,201 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:28:42,201 INFO OK: read value = false
2026-02-02 15:28:42,201 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:28:42,202 INFO OK: read value = false
2026-02-02 15:28:42,202 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:28:42,202 INFO OK: read value = false
2026-02-02 15:28:42,204 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:28:42,204 INFO OK: read value = false
2026-02-02 15:28:42,205 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:28:42,205 INFO OK: read value = false
2026-02-02 15:28:42,205 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:28:42,206 INFO OK: read value = false
2026-02-02 15:28:42,206 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:28:42,206 INFO OK: read value = false
2026-02-02 15:28:42,206 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:28:42,206 INFO OK: read value = false
2026-02-02 15:28:42,207 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:28:42,207 INFO OK: read value = false
2026-02-02 15:28:42,207 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:28:42,208 INFO OK: read value = false
2026-02-02 15:28:42,208 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:28:42,208 INFO OK: read value = false
2026-02-02 15:28:42,208 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:28:42,209 INFO OK: read value = false
2026-02-02 15:28:42,209 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:28:42,209 INFO OK: read value = false
2026-02-02 15:28:42,210 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:28:42,210 INFO OK: read value = false
2026-02-02 15:28:42,210 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:28:42,210 INFO OK: read value = false
2026-02-02 15:28:42,211 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:28:42,211 INFO OK: read value = false
2026-02-02 15:28:42,211 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:28:42,211 INFO OK: read value = false
2026-02-02 15:28:42,211 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:28:42,212 INFO OK: read value = false
2026-02-02 15:28:42,213 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:28:42,213 INFO OK: read value = false
2026-02-02 15:28:42,213 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:28:42,214 INFO OK: read value = false
2026-02-02 15:28:42,214 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:28:42,215 INFO OK: read value = false
2026-02-02 15:28:42,216 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:28:42,216 INFO OK: read value = false
2026-02-02 15:28:42,216 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:28:42,216 INFO OK: read value = false
2026-02-02 15:28:42,216 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:28:42,217 INFO OK: read value = false
2026-02-02 15:28:42,217 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:28:42,217 INFO OK: read value = false
2026-02-02 15:28:42,217 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:28:42,217 INFO OK: read value = false
2026-02-02 15:28:42,218 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:28:42,218 INFO OK: read value = false
2026-02-02 15:28:42,218 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:28:42,218 INFO OK: read value = false
2026-02-02 15:28:42,218 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:28:42,219 INFO OK: read value = false
2026-02-02 15:28:42,219 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:28:42,219 INFO OK: read value = false
2026-02-02 15:28:42,219 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:28:42,219 INFO OK: read value = false
2026-02-02 15:28:42,220 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:28:42,220 INFO OK: read value = false
2026-02-02 15:28:42,220 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:28:42,221 INFO OK: read value = false
2026-02-02 15:28:42,221 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:28:42,221 INFO OK: read value = false
2026-02-02 15:28:42,222 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:28:42,222 INFO OK: read value = false
2026-02-02 15:28:42,222 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:28:42,222 INFO OK: read value = false
2026-02-02 15:28:42,223 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:28:42,223 INFO OK: read value = false
2026-02-02 15:28:42,223 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:28:42,223 INFO OK: read value = false
2026-02-02 15:28:42,224 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:28:42,224 INFO OK: read value = false
2026-02-02 15:28:42,224 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:28:42,224 INFO OK: read value = false
2026-02-02 15:28:42,224 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:28:42,225 INFO OK: read value = false
2026-02-02 15:28:42,225 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:28:42,225 INFO OK: read value = false
2026-02-02 15:28:42,225 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:28:42,226 INFO OK: read value = false
2026-02-02 15:28:42,226 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:28:42,226 INFO OK: read value = false
2026-02-02 15:28:42,226 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:28:42,226 INFO OK: read value = false
2026-02-02 15:28:42,226 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:28:42,227 INFO OK: read value = false
2026-02-02 15:28:42,227 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:28:42,227 INFO OK: read value = false
2026-02-02 15:28:42,227 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:28:42,227 INFO OK: read value = false
2026-02-02 15:28:42,227 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:28:42,227 INFO OK: read value = false
2026-02-02 15:28:42,227 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:28:42,228 INFO OK: read value = false
2026-02-02 15:28:42,228 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:28:42,228 INFO OK: read value = false
2026-02-02 15:28:42,228 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:28:42,228 INFO OK: read value = false
2026-02-02 15:28:42,228 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:28:42,228 INFO OK: read value = false
2026-02-02 15:28:42,228 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:28:42,229 INFO OK: read value = false
2026-02-02 15:28:42,229 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:28:42,229 INFO OK: read value = false
2026-02-02 15:28:42,229 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:28:42,229 INFO OK: read value = false
2026-02-02 15:28:42,230 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:28:42,230 INFO OK: read value = false
2026-02-02 15:28:42,230 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:28:42,230 INFO OK: read value = false
2026-02-02 15:28:42,230 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:28:42,230 INFO OK: read value = false
2026-02-02 15:28:42,230 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:28:42,230 INFO OK: read value = false
2026-02-02 15:28:42,231 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:28:42,231 INFO OK: read value = false
2026-02-02 15:28:42,231 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:28:42,231 INFO OK: read value = false
2026-02-02 15:28:42,231 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:28:42,232 INFO OK: read value = false
2026-02-02 15:28:42,232 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:28:42,232 INFO OK: read value = false
2026-02-02 15:28:42,232 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:28:42,232 INFO OK: read value = false
2026-02-02 15:28:42,232 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:28:42,232 INFO OK: read value = false
2026-02-02 15:28:42,233 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:28:42,233 INFO OK: read value = false
2026-02-02 15:28:42,233 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:28:42,233 INFO OK: read value = false
2026-02-02 15:28:42,233 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:28:42,233 INFO OK: read value = false
2026-02-02 15:28:42,234 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:28:42,234 INFO OK: read value = false
2026-02-02 15:28:42,234 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:28:42,234 INFO OK: read value = false
2026-02-02 15:28:42,235 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:28:42,235 INFO OK: read value = false
2026-02-02 15:28:42,235 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:28:42,235 INFO OK: read value = false
2026-02-02 15:28:42,235 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:28:42,236 INFO OK: read value = false
2026-02-02 15:28:42,236 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:28:42,236 INFO OK: read value = false
2026-02-02 15:28:42,236 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:28:42,236 INFO OK: read value = false
2026-02-02 15:28:42,237 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:28:42,237 INFO OK: read value = false
2026-02-02 15:28:42,237 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:28:42,237 INFO OK: read value = false
2026-02-02 15:28:42,238 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:28:42,238 INFO OK: read value = false
2026-02-02 15:28:42,238 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:28:42,238 INFO OK: read value = false
2026-02-02 15:28:42,239 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:28:42,239 INFO OK: read value = false
2026-02-02 15:28:42,239 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:28:42,239 INFO OK: read value = false
2026-02-02 15:28:42,239 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:28:42,239 INFO OK: read value = false
2026-02-02 15:28:42,240 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:28:42,240 INFO OK: read value = false
2026-02-02 15:28:42,240 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:28:42,240 INFO OK: read value = false
2026-02-02 15:28:42,240 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:28:42,240 INFO OK: read value = false
2026-02-02 15:28:42,240 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:28:42,241 INFO OK: read value = false
2026-02-02 15:28:42,241 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:28:42,241 INFO OK: read value = false
2026-02-02 15:28:42,241 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:28:42,241 INFO OK: read value = false
2026-02-02 15:28:42,241 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:28:42,242 INFO OK: read value = false
2026-02-02 15:28:42,242 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:28:42,242 INFO OK: read value = false
2026-02-02 15:28:42,242 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:28:42,242 INFO OK: read value = false
2026-02-02 15:28:42,242 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:28:42,242 INFO OK: read value = false
2026-02-02 15:28:42,242 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:28:42,243 INFO OK: read value = false
2026-02-02 15:28:42,243 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:28:42,243 INFO OK: read value = false
2026-02-02 15:28:42,243 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:28:42,243 INFO OK: read value = false
2026-02-02 15:28:42,243 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:28:42,244 INFO OK: read value = false
2026-02-02 15:28:42,244 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:28:42,244 INFO OK: read value = false
2026-02-02 15:28:42,244 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:28:42,244 INFO OK: read value = false
2026-02-02 15:28:42,245 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:28:42,245 INFO OK: read value = false
2026-02-02 15:28:42,245 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:28:42,245 INFO OK: read value = false
2026-02-02 15:28:42,246 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:28:42,247 INFO OK: read value = false
2026-02-02 15:28:42,248 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:28:42,248 INFO OK: read value = false
2026-02-02 15:28:42,249 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:28:42,249 INFO OK: read value = false
2026-02-02 15:28:42,249 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:28:42,249 INFO OK: read value = false
2026-02-02 15:28:42,250 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:28:42,250 INFO OK: read value = false
2026-02-02 15:28:42,250 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:28:42,250 INFO OK: read value = false
2026-02-02 15:28:42,250 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:28:42,250 INFO OK: read value = false
2026-02-02 15:28:42,251 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:28:42,251 INFO OK: read value = false
2026-02-02 15:28:42,251 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:28:42,252 INFO OK: read value = false
2026-02-02 15:28:42,252 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:28:42,252 INFO OK: read value = false
2026-02-02 15:28:42,252 INFO [Run 2] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:28:42,253 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:28:42,253 INFO 0.0s remaining ...
2026-02-02 15:28:42,253 INFO [Run 2] Serial: 2 total, 0 errors, 2 fatal, 2 recycles
2026-02-02 15:28:42,254 INFO Target Detection Test
2026-02-02 15:28:42,254 INFO [Run 2] Starting target detection test (timeout: 5.0s)
2026-02-02 15:28:42,254 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:28:42,264 INFO TgtMsg: 2 2
2026-02-02 15:28:42,265 INFO Tgt: 1 @ 1180
2026-02-02 15:28:42,265 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:28:42,266 INFO OK: read value = 1
2026-02-02 15:28:42,266 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:28:42,266 DEBUG [MOCK] Field rng: 1180
2026-02-02 15:28:42,266 INFO OK: read value = 1180
2026-02-02 15:28:42,266 INFO Target detected successfully in 0.01s
2026-02-02 15:28:42,267 INFO [Run 2] Target DETECTED in 0.01s
2026-02-02 15:28:42,267 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3
Total Step 192: Success 189 (98.44%), Failed 3 (1.56%),
2026-02-02 15:28:42,267 INFO Repetition 3 of 3
2026-02-02 15:28:42,267 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:28:42,267 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:28:43,269 INFO Set MAIN_POWER to False
2026-02-02 15:28:43,269 INFO [MOCK] Power OFF
2026-02-02 15:28:43,269 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:28:48,269 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:28:48,270 INFO OK: read value = False
2026-02-02 15:28:52,273 INFO The test operator is required to switch on the target.
2026-02-02 15:28:52,274 INFO Set MAIN_POWER to True
2026-02-02 15:28:52,274 INFO [MOCK] Power ON
2026-02-02 15:28:52,274 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:28:52,275 INFO run_count = 3
2026-02-02 15:28:52,275 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:28:52,275 INFO current_scenario = 'mixed'
2026-02-02 15:28:52,275 INFO _scenario_list = ['recycle_recovery_2', 'normal', 'recycle_recovery_2']
2026-02-02 15:28:52,275 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:28:52,275 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='recycle_recovery_2'
2026-02-02 15:28:52,276 INFO [DEBUG] About to call _log_scenario_info('recycle_recovery_2', 3, 3)
2026-02-02 15:28:52,276 INFO
2026-02-02 15:28:52,276 INFO ####################################################################################################
2026-02-02 15:28:52,276 INFO ####################################################################################################
2026-02-02 15:28:52,276 INFO ### RUN 3/3: RECYCLE SELF-HEALING (2 CYCLES)
2026-02-02 15:28:52,276 INFO ####################################################################################################
2026-02-02 15:28:52,276 INFO
2026-02-02 15:28:52,276 INFO SCENARIO: recycle_recovery_2
2026-02-02 15:28:52,276 INFO DESCRIPTION: Processor fails, then auto-recovers after 2 RECYCLE events
2026-02-02 15:28:52,276 INFO
2026-02-02 15:28:52,276 INFO EXPECTED FAILURES:
2026-02-02 15:28:52,276 INFO ✗ Initial: processor_status = FAIL
2026-02-02 15:28:52,276 INFO ✗ Serial: 2x RECYCLE events detected
2026-02-02 15:28:52,276 INFO
2026-02-02 15:28:52,276 INFO EXPECTED PASSES:
2026-02-02 15:28:52,276 INFO ✓ After 2nd RECYCLE: processor_status = PASS
2026-02-02 15:28:52,277 INFO ✓ Final: All systems OK
2026-02-02 15:28:52,277 INFO
2026-02-02 15:28:52,277 INFO NOTES: Simulates persistent failure requiring multiple recovery attempts
2026-02-02 15:28:52,277 INFO
2026-02-02 15:28:52,277 INFO ####################################################################################################
2026-02-02 15:28:52,277 INFO ####################################################################################################
2026-02-02 15:28:52,277 INFO
2026-02-02 15:28:52,277 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:28:52,277 INFO [MOCK APPLY] ⚠ RECYCLE scenario enabled: 2 cycles to recovery
2026-02-02 15:28:52,277 INFO [MOCK RECYCLE] Initial processor failure detected
2026-02-02 15:28:52,777 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:28:52,778 INFO [MOCK RECYCLE] RECYCLE 1/2
2026-02-02 15:28:53,278 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:28:53,279 INFO [MOCK RECYCLE] RECYCLE 2/2
2026-02-02 15:28:53,579 INFO [MOCK RECYCLE] System recovered after 2 RECYCLEs (slower self-healing)
2026-02-02 15:28:53,580 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3)
2026-02-02 15:28:58,581 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:28:58,581 INFO OK: read value = True
2026-02-02 15:28:58,682 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:28:58,882 INFO [MOCK] BIT report available after 6.6s
2026-02-02 15:28:58,903 INFO BIT report available after 0.2s
2026-02-02 15:28:58,903 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:28:58,904 INFO OK: read value = false
2026-02-02 15:28:58,904 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:28:58,904 WARNING CHECK ERROR: read value = true
2026-02-02 15:28:58,904 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:28:58,904 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:28:58,904 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:28:58,905 INFO OK: read value = false
2026-02-02 15:28:58,905 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:28:58,905 INFO OK: read value = false
2026-02-02 15:28:58,905 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:28:58,905 INFO OK: read value = false
2026-02-02 15:28:58,905 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:28:58,905 INFO OK: read value = false
2026-02-02 15:28:58,905 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:28:58,905 INFO OK: read value = false
2026-02-02 15:28:58,906 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:28:58,906 INFO OK: read value = false
2026-02-02 15:28:58,906 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:28:58,906 INFO OK: read value = false
2026-02-02 15:28:58,906 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:28:58,906 INFO OK: read value = false
2026-02-02 15:28:58,906 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:28:58,906 INFO OK: read value = false
2026-02-02 15:28:58,907 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:28:58,907 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 15:28:58,907 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 15:28:58,907 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 15:28:58,907 INFO [Run 3] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 15:28:58,907 INFO Known failures (HW setup): 2
2026-02-02 15:28:58,907 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 15:28:58,907 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 15:28:58,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:28:58,908 INFO OK: read value = false
2026-02-02 15:28:58,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:28:58,908 INFO OK: read value = false
2026-02-02 15:28:58,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:28:58,908 INFO OK: read value = false
2026-02-02 15:28:58,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:28:58,908 INFO OK: read value = false
2026-02-02 15:28:58,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:28:58,908 INFO OK: read value = false
2026-02-02 15:28:58,908 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:28:58,909 INFO OK: read value = false
2026-02-02 15:28:58,909 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:28:58,909 INFO OK: read value = false
2026-02-02 15:28:58,909 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:28:58,909 INFO OK: read value = false
2026-02-02 15:28:58,909 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:28:58,909 INFO OK: read value = false
2026-02-02 15:28:58,912 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:28:58,913 WARNING CHECK ERROR: read value = 0
2026-02-02 15:28:58,913 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:28:58,914 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:28:58,914 INFO OK: read value = false
2026-02-02 15:28:58,914 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:28:58,914 INFO OK: read value = false
2026-02-02 15:28:58,914 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:28:58,914 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:28:58,914 INFO OK: read value = false
2026-02-02 15:28:58,915 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:28:58,915 INFO OK: read value = false
2026-02-02 15:28:58,915 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:28:58,915 INFO OK: read value = false
2026-02-02 15:28:58,915 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:28:58,915 INFO OK: read value = false
2026-02-02 15:28:58,915 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:28:58,915 INFO OK: read value = false
2026-02-02 15:28:58,916 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:28:58,916 INFO OK: read value = false
2026-02-02 15:28:58,916 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:28:58,916 INFO OK: read value = false
2026-02-02 15:28:58,916 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:28:58,916 INFO OK: read value = false
2026-02-02 15:28:58,916 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:28:58,916 INFO OK: read value = false
2026-02-02 15:28:58,917 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:28:58,917 INFO OK: read value = false
2026-02-02 15:28:58,917 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:28:58,917 INFO OK: read value = false
2026-02-02 15:28:58,917 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:28:58,917 INFO OK: read value = false
2026-02-02 15:28:58,917 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:28:58,918 INFO OK: read value = false
2026-02-02 15:28:58,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:28:58,918 INFO OK: read value = false
2026-02-02 15:28:58,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:28:58,918 INFO OK: read value = false
2026-02-02 15:28:58,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:28:58,918 INFO OK: read value = false
2026-02-02 15:28:58,918 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:28:58,918 INFO OK: read value = false
2026-02-02 15:28:58,919 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:28:58,919 INFO OK: read value = false
2026-02-02 15:28:58,921 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:28:58,921 INFO OK: read value = false
2026-02-02 15:28:58,921 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:28:58,921 INFO OK: read value = false
2026-02-02 15:28:58,922 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:28:58,922 INFO OK: read value = false
2026-02-02 15:28:58,922 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:28:58,922 INFO OK: read value = false
2026-02-02 15:28:58,922 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:28:58,922 INFO OK: read value = false
2026-02-02 15:28:58,923 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:28:58,923 INFO OK: read value = false
2026-02-02 15:28:58,923 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:28:58,923 INFO OK: read value = false
2026-02-02 15:28:58,923 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:28:58,923 INFO OK: read value = false
2026-02-02 15:28:58,924 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:28:58,924 INFO OK: read value = false
2026-02-02 15:28:58,924 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:28:58,924 INFO OK: read value = false
2026-02-02 15:28:58,924 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:28:58,925 INFO OK: read value = false
2026-02-02 15:28:58,925 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:28:58,925 INFO OK: read value = false
2026-02-02 15:28:58,926 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:28:58,926 INFO OK: read value = false
2026-02-02 15:28:58,926 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:28:58,926 INFO OK: read value = false
2026-02-02 15:28:58,926 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:28:58,926 INFO OK: read value = false
2026-02-02 15:28:58,926 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:28:58,926 INFO OK: read value = false
2026-02-02 15:28:58,927 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:28:58,927 INFO OK: read value = false
2026-02-02 15:28:58,927 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:28:58,927 INFO OK: read value = false
2026-02-02 15:28:58,927 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:28:58,927 INFO OK: read value = false
2026-02-02 15:28:58,927 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:28:58,928 INFO OK: read value = false
2026-02-02 15:28:58,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:28:58,928 INFO OK: read value = false
2026-02-02 15:28:58,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:28:58,928 INFO OK: read value = false
2026-02-02 15:28:58,929 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:28:58,929 INFO OK: read value = false
2026-02-02 15:28:58,929 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:28:58,930 INFO OK: read value = false
2026-02-02 15:28:58,930 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:28:58,930 INFO OK: read value = false
2026-02-02 15:28:58,930 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:28:58,930 INFO OK: read value = false
2026-02-02 15:28:58,930 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:28:58,931 INFO OK: read value = false
2026-02-02 15:28:58,931 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:28:58,931 INFO OK: read value = false
2026-02-02 15:28:58,931 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:28:58,932 INFO OK: read value = false
2026-02-02 15:28:58,932 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:28:58,932 INFO OK: read value = false
2026-02-02 15:28:58,932 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:28:58,932 INFO OK: read value = false
2026-02-02 15:28:58,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:28:58,933 INFO OK: read value = false
2026-02-02 15:28:58,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:28:58,933 INFO OK: read value = false
2026-02-02 15:28:58,934 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:28:58,934 INFO OK: read value = false
2026-02-02 15:28:58,935 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:28:58,935 INFO OK: read value = false
2026-02-02 15:28:58,935 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:28:58,936 INFO OK: read value = false
2026-02-02 15:28:58,937 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:28:58,937 INFO OK: read value = false
2026-02-02 15:28:58,937 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:28:58,937 INFO OK: read value = false
2026-02-02 15:28:58,937 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:28:58,938 INFO OK: read value = false
2026-02-02 15:28:58,938 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:28:58,938 INFO OK: read value = false
2026-02-02 15:28:58,939 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:28:58,939 INFO OK: read value = false
2026-02-02 15:28:58,939 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:28:58,939 INFO OK: read value = false
2026-02-02 15:28:58,939 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:28:58,939 INFO OK: read value = false
2026-02-02 15:28:58,939 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:28:58,939 INFO OK: read value = false
2026-02-02 15:28:58,940 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:28:58,940 INFO OK: read value = false
2026-02-02 15:28:58,940 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:28:58,940 INFO OK: read value = false
2026-02-02 15:28:58,940 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:28:58,940 INFO OK: read value = false
2026-02-02 15:28:58,940 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:28:58,940 INFO OK: read value = false
2026-02-02 15:28:58,941 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:28:58,941 INFO OK: read value = false
2026-02-02 15:28:58,941 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:28:58,941 INFO OK: read value = false
2026-02-02 15:28:58,942 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:28:58,942 INFO OK: read value = false
2026-02-02 15:28:58,942 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:28:58,942 INFO OK: read value = false
2026-02-02 15:28:58,942 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:28:58,942 INFO OK: read value = false
2026-02-02 15:28:58,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:28:58,943 INFO OK: read value = false
2026-02-02 15:28:58,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:28:58,943 INFO OK: read value = false
2026-02-02 15:28:58,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:28:58,943 INFO OK: read value = false
2026-02-02 15:28:58,944 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:28:58,944 INFO OK: read value = false
2026-02-02 15:28:58,944 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:28:58,944 INFO OK: read value = false
2026-02-02 15:28:58,944 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:28:58,945 INFO OK: read value = false
2026-02-02 15:28:58,945 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:28:58,945 INFO OK: read value = false
2026-02-02 15:28:58,945 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:28:58,945 INFO OK: read value = false
2026-02-02 15:28:58,946 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:28:58,946 INFO OK: read value = false
2026-02-02 15:28:58,946 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:28:58,946 INFO OK: read value = false
2026-02-02 15:28:58,947 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:28:58,947 INFO OK: read value = false
2026-02-02 15:28:58,947 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:28:58,947 INFO OK: read value = false
2026-02-02 15:28:58,948 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:28:58,948 INFO OK: read value = false
2026-02-02 15:28:58,949 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:28:58,949 INFO OK: read value = false
2026-02-02 15:28:58,949 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:28:58,949 INFO OK: read value = false
2026-02-02 15:28:58,949 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:28:58,949 INFO OK: read value = false
2026-02-02 15:28:58,950 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:28:58,951 INFO OK: read value = false
2026-02-02 15:28:58,951 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:28:58,951 INFO OK: read value = false
2026-02-02 15:28:58,952 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:28:58,952 INFO OK: read value = false
2026-02-02 15:28:58,952 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:28:58,952 INFO OK: read value = false
2026-02-02 15:28:58,952 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:28:58,952 INFO OK: read value = false
2026-02-02 15:28:58,952 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:28:58,953 INFO OK: read value = false
2026-02-02 15:28:58,953 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:28:58,953 INFO OK: read value = false
2026-02-02 15:28:58,953 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:28:58,953 INFO OK: read value = false
2026-02-02 15:28:58,953 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:28:58,953 INFO OK: read value = false
2026-02-02 15:28:58,954 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:28:58,954 INFO OK: read value = false
2026-02-02 15:28:58,954 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:28:58,954 INFO OK: read value = false
2026-02-02 15:28:58,954 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:28:58,955 INFO OK: read value = false
2026-02-02 15:28:58,955 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:28:58,955 INFO OK: read value = false
2026-02-02 15:28:58,955 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:28:58,956 INFO OK: read value = false
2026-02-02 15:28:58,956 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:28:58,956 INFO OK: read value = false
2026-02-02 15:28:58,956 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:28:58,956 INFO OK: read value = false
2026-02-02 15:28:58,957 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:28:58,957 INFO OK: read value = false
2026-02-02 15:28:58,957 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:28:58,957 INFO OK: read value = false
2026-02-02 15:28:58,957 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:28:58,958 INFO OK: read value = false
2026-02-02 15:28:58,958 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:28:58,958 INFO OK: read value = false
2026-02-02 15:28:58,958 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:28:58,958 INFO OK: read value = false
2026-02-02 15:28:58,958 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:28:58,959 INFO OK: read value = false
2026-02-02 15:28:58,959 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:28:58,959 INFO OK: read value = false
2026-02-02 15:28:58,959 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:28:58,959 INFO OK: read value = false
2026-02-02 15:28:58,960 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:28:58,960 INFO OK: read value = false
2026-02-02 15:28:58,960 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:28:58,960 INFO OK: read value = false
2026-02-02 15:28:58,960 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:28:58,961 INFO OK: read value = false
2026-02-02 15:28:58,961 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:28:58,961 INFO OK: read value = false
2026-02-02 15:28:58,961 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:28:58,961 INFO OK: read value = false
2026-02-02 15:28:58,962 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:28:58,962 INFO OK: read value = false
2026-02-02 15:28:58,962 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:28:58,962 INFO OK: read value = false
2026-02-02 15:28:58,963 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:28:58,963 INFO OK: read value = false
2026-02-02 15:28:58,963 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:28:58,963 INFO OK: read value = false
2026-02-02 15:28:58,963 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:28:58,964 INFO OK: read value = false
2026-02-02 15:28:58,964 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:28:58,964 INFO OK: read value = false
2026-02-02 15:28:58,964 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:28:58,964 INFO OK: read value = false
2026-02-02 15:28:58,965 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:28:58,965 INFO OK: read value = false
2026-02-02 15:28:58,965 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:28:58,965 INFO OK: read value = false
2026-02-02 15:28:58,966 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:28:58,966 INFO OK: read value = false
2026-02-02 15:28:58,966 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:28:58,966 INFO OK: read value = false
2026-02-02 15:28:58,966 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:28:58,967 INFO OK: read value = false
2026-02-02 15:28:58,967 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:28:58,967 INFO OK: read value = false
2026-02-02 15:28:58,967 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:28:58,967 INFO OK: read value = false
2026-02-02 15:28:58,968 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:28:58,968 INFO OK: read value = false
2026-02-02 15:28:58,968 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:28:58,968 INFO OK: read value = false
2026-02-02 15:28:58,968 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:28:58,969 INFO OK: read value = false
2026-02-02 15:28:58,970 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:28:58,971 INFO OK: read value = false
2026-02-02 15:28:58,971 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:28:58,971 INFO OK: read value = false
2026-02-02 15:28:58,971 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:28:58,971 INFO OK: read value = false
2026-02-02 15:28:58,971 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:28:58,972 INFO OK: read value = false
2026-02-02 15:28:58,972 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:28:58,972 INFO OK: read value = false
2026-02-02 15:28:58,972 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:28:58,972 INFO OK: read value = false
2026-02-02 15:28:58,972 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:28:58,973 INFO OK: read value = false
2026-02-02 15:28:58,973 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:28:58,973 INFO OK: read value = false
2026-02-02 15:28:58,973 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:28:58,973 INFO OK: read value = false
2026-02-02 15:28:58,973 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:28:58,974 INFO OK: read value = false
2026-02-02 15:28:58,974 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:28:58,974 INFO OK: read value = false
2026-02-02 15:28:58,974 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:28:58,975 INFO OK: read value = false
2026-02-02 15:28:58,975 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:28:58,975 INFO OK: read value = false
2026-02-02 15:28:58,975 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:28:58,975 INFO OK: read value = false
2026-02-02 15:28:58,975 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:28:58,976 INFO OK: read value = false
2026-02-02 15:28:58,976 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:28:58,976 INFO OK: read value = false
2026-02-02 15:28:58,976 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:28:58,976 INFO OK: read value = false
2026-02-02 15:28:58,976 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:28:58,977 INFO OK: read value = false
2026-02-02 15:28:58,977 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:28:58,977 INFO OK: read value = false
2026-02-02 15:28:58,977 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:28:58,977 INFO OK: read value = false
2026-02-02 15:28:58,977 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:28:58,977 INFO OK: read value = false
2026-02-02 15:28:58,978 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:28:58,978 INFO OK: read value = false
2026-02-02 15:28:58,978 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:28:58,978 INFO OK: read value = false
2026-02-02 15:28:58,978 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:28:58,978 INFO OK: read value = false
2026-02-02 15:28:58,978 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:28:58,979 INFO OK: read value = false
2026-02-02 15:28:58,979 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:28:58,979 INFO OK: read value = false
2026-02-02 15:28:58,979 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:28:58,980 INFO OK: read value = false
2026-02-02 15:28:58,980 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:28:58,981 INFO OK: read value = false
2026-02-02 15:28:58,982 INFO [Run 3] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:28:58,982 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:28:58,984 INFO 0.0s remaining ...
2026-02-02 15:28:58,984 INFO [Run 3] Serial: 2 total, 0 errors, 2 fatal, 2 recycles
2026-02-02 15:28:58,984 INFO Target Detection Test
2026-02-02 15:28:58,985 INFO [Run 3] Starting target detection test (timeout: 5.0s)
2026-02-02 15:28:58,985 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:28:58,995 INFO TgtMsg: 3 3
2026-02-02 15:28:58,995 INFO Tgt: 1 @ 1180
2026-02-02 15:28:58,996 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:28:58,996 INFO OK: read value = 1
2026-02-02 15:28:58,996 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:28:58,996 INFO OK: read value = 1180
2026-02-02 15:28:58,997 INFO Target detected successfully in 0.01s
2026-02-02 15:28:58,997 INFO [Run 3] Target DETECTED in 0.01s
2026-02-02 15:28:58,997 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3
Total Step 192: Success 189 (98.44%), Failed 3 (1.56%),
2026-02-02 15:28:58,998 INFO Repetitions terminated.
2026-02-02 15:28:58,998 INFO [Report] Custom statistics data registered for PDF generation
2026-02-02 15:28:58,999 INFO ==========================================================================================
2026-02-02 15:28:58,999 INFO FINAL TEST STATISTICS SUMMARY
2026-02-02 15:28:58,999 INFO ==========================================================================================
2026-02-02 15:28:58,999 INFO Total Runs: 3
2026-02-02 15:28:59,000 INFO Successful: 3 (100.0%)
2026-02-02 15:28:59,000 INFO Failed: 0 (0.0%)
2026-02-02 15:28:59,000 INFO B6 Checks: 36 (Pass: 30, Fail: 0, Known: 6)
2026-02-02 15:28:59,000 INFO B8 Checks: 519 (Pass: 516, Fail: 3)
2026-02-02 15:28:59,000 INFO Serial: 6 messages (0 errors, 6 fatal, 6 recycles)
2026-02-02 15:28:59,000 INFO Target: 3 detected, 0 not detected (100.0% pass rate)
2026-02-02 15:28:59,000 INFO PBIT Timing: avg=0.22s, min=0.22s, max=0.22s, σ=0.00s
2026-02-02 15:28:59,001 INFO ==========================================================================================
2026-02-02 15:28:59,001 INFO Detailed statistics will be available in the PDF report
2026-02-02 15:28:59,001 INFO Exporting statistics to CSV: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_152859_statistics.csv
2026-02-02 15:28:59,019 INFO Statistics exported successfully to: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_152859_statistics.csv
2026-02-02 15:28:59,021 INFO Statistics exported successfully to JSON: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_152859_statistics.json
2026-02-02 15:28:59,022 INFO Set MAIN_POWER to False
2026-02-02 15:28:59,022 INFO [MOCK] Power OFF
2026-02-02 15:28:59,022 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:29:04,023 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:29:04,023 INFO OK: read value = False
2026-02-02 15:29:04,023 INFO [MOCK] Serial terminal disconnected
2026-02-02 15:29:04,024 INFO Stop Time: 2026-02-02 15:28:08.463987
2026-02-02 15:29:04,024 INFO Test execution time: 0:00:55.560264