2026-02-02 15:38:47,997 INFO Start Time: 2026-02-02 15:38:47.997168
2026-02-02 15:38:47,997 INFO [MOCK] Serial terminal initialized
2026-02-02 15:38:47,997 INFO [MOCK] Serial terminal connected
2026-02-02 15:38:47,997 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-02 15:38:47,998 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-02-02 15:38:47,998 INFO [MOCK] Simulating target acquisition: will appear after 11 scan cycles
2026-02-02 15:38:48,008 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,058 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,109 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,160 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,211 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,262 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,312 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,363 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,414 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,465 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,515 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,566 INFO [MOCK] Target simulated at distance 1180
2026-02-02 15:38:48,566 INFO [MOCK] Log started at level 3 in directory: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts
2026-02-02 15:38:48,566 INFO tgt_gen_alone(): 0
2026-02-02 15:38:48,567 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:38:48,577 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-02 15:38:48,577 INFO TgtMsg: 0 0
2026-02-02 15:38:48,577 INFO Tgt: 1 @ 1180
2026-02-02 15:38:48,578 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:38:48,578 DEBUG [MOCK] Field num: 1
2026-02-02 15:38:48,578 INFO OK: read value = 1
2026-02-02 15:38:48,578 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:38:48,578 INFO OK: read value = 1180
2026-02-02 15:38:48,579 INFO [MOCK] Log stopped
2026-02-02 15:38:48,579 INFO Repetition 1 of 3
2026-02-02 15:38:48,579 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:38:48,579 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:38:49,580 INFO Set MAIN_POWER to False
2026-02-02 15:38:49,580 INFO [MOCK] Power OFF
2026-02-02 15:38:49,580 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:38:54,581 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:38:54,581 INFO OK: read value = False
2026-02-02 15:38:58,581 INFO The test operator is required to switch on the target.
2026-02-02 15:38:58,582 INFO Set MAIN_POWER to True
2026-02-02 15:38:58,582 INFO [MOCK] Power ON
2026-02-02 15:38:58,582 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:38:58,583 INFO run_count = 1
2026-02-02 15:38:58,583 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:38:58,583 INFO current_scenario = 'mixed'
2026-02-02 15:38:58,583 INFO _scenario_list = ['normal', 'mixed_b8_failures', 'receiver_fail']
2026-02-02 15:38:58,583 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:38:58,584 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='normal'
2026-02-02 15:38:58,584 INFO [DEBUG] About to call _log_scenario_info('normal', 1, 3)
2026-02-02 15:38:58,584 INFO
2026-02-02 15:38:58,585 INFO ####################################################################################################
2026-02-02 15:38:58,585 INFO ####################################################################################################
2026-02-02 15:38:58,585 INFO ### RUN 1/3: NORMAL OPERATION
2026-02-02 15:38:58,585 INFO ####################################################################################################
2026-02-02 15:38:58,585 INFO
2026-02-02 15:38:58,585 INFO SCENARIO: normal
2026-02-02 15:38:58,585 INFO DESCRIPTION: All systems operational - no failures
2026-02-02 15:38:58,586 INFO
2026-02-02 15:38:58,586 INFO EXPECTED FAILURES:
2026-02-02 15:38:58,586 INFO (none)
2026-02-02 15:38:58,586 INFO
2026-02-02 15:38:58,586 INFO EXPECTED PASSES:
2026-02-02 15:38:58,586 INFO ✓ All B6 status fields (except pedestal)
2026-02-02 15:38:58,586 INFO ✓ All B8 diagnostic fields
2026-02-02 15:38:58,586 INFO ✓ Target generation
2026-02-02 15:38:58,586 INFO
2026-02-02 15:38:58,586 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present)
2026-02-02 15:38:58,586 INFO
2026-02-02 15:38:58,586 INFO ####################################################################################################
2026-02-02 15:38:58,587 INFO ####################################################################################################
2026-02-02 15:38:58,587 INFO
2026-02-02 15:38:58,587 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:38:58,587 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected)
2026-02-02 15:38:58,587 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1)
2026-02-02 15:39:03,588 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:39:03,588 INFO OK: read value = True
2026-02-02 15:39:03,689 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:39:03,890 INFO [MOCK] BIT report available after 5.3s
2026-02-02 15:39:03,910 INFO BIT report available after 0.2s
2026-02-02 15:39:03,911 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:39:03,911 INFO OK: read value = false
2026-02-02 15:39:03,911 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:39:03,911 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:03,911 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:03,911 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:39:03,911 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:39:03,912 INFO OK: read value = false
2026-02-02 15:39:03,912 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:39:03,912 INFO OK: read value = false
2026-02-02 15:39:03,912 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:39:03,912 INFO OK: read value = false
2026-02-02 15:39:03,912 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:39:03,912 INFO OK: read value = false
2026-02-02 15:39:03,912 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:39:03,913 INFO OK: read value = false
2026-02-02 15:39:03,913 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:39:03,913 INFO OK: read value = false
2026-02-02 15:39:03,913 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:39:03,913 INFO OK: read value = false
2026-02-02 15:39:03,913 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:39:03,913 INFO OK: read value = false
2026-02-02 15:39:03,914 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:39:03,914 INFO OK: read value = false
2026-02-02 15:39:03,914 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:39:03,914 WARNING CHECK ERROR: read value = RDR_OK
2026-02-02 15:39:03,914 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-02-02 15:39:03,914 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-02-02 15:39:03,914 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-02-02 15:39:03,914 INFO Known failures (HW setup): 2
2026-02-02 15:39:03,915 INFO
Forced B8 drill-down (FORCE_B8_DRILL_DOWN=True): Verifying all 173 B8 diagnostic fields...
2026-02-02 15:39:03,915 INFO [FORCE_B8_DRILL_DOWN] Performing B8 drill-down despite only known failures
2026-02-02 15:39:03,915 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:39:03,915 INFO OK: read value = false
2026-02-02 15:39:03,915 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:39:03,915 INFO OK: read value = false
2026-02-02 15:39:03,915 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:39:03,916 INFO OK: read value = false
2026-02-02 15:39:03,916 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:39:03,916 INFO OK: read value = false
2026-02-02 15:39:03,916 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:39:03,916 INFO OK: read value = false
2026-02-02 15:39:03,916 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:39:03,916 INFO OK: read value = false
2026-02-02 15:39:03,917 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:39:03,917 INFO OK: read value = false
2026-02-02 15:39:03,917 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:39:03,917 INFO OK: read value = false
2026-02-02 15:39:03,917 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:39:03,917 INFO OK: read value = false
2026-02-02 15:39:03,917 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:39:03,918 WARNING CHECK ERROR: read value = 0
2026-02-02 15:39:03,918 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:39:03,918 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:39:03,918 INFO OK: read value = false
2026-02-02 15:39:03,918 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:39:03,918 INFO OK: read value = false
2026-02-02 15:39:03,918 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:39:03,918 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:39:03,918 INFO OK: read value = false
2026-02-02 15:39:03,918 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:39:03,919 INFO OK: read value = false
2026-02-02 15:39:03,919 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:39:03,919 INFO OK: read value = false
2026-02-02 15:39:03,919 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:39:03,919 INFO OK: read value = false
2026-02-02 15:39:03,919 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:39:03,919 INFO OK: read value = false
2026-02-02 15:39:03,919 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:39:03,920 INFO OK: read value = false
2026-02-02 15:39:03,920 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:39:03,920 INFO OK: read value = false
2026-02-02 15:39:03,920 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:39:03,920 INFO OK: read value = false
2026-02-02 15:39:03,920 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:39:03,920 INFO OK: read value = false
2026-02-02 15:39:03,922 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:39:03,922 INFO OK: read value = false
2026-02-02 15:39:03,922 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:39:03,922 INFO OK: read value = false
2026-02-02 15:39:03,922 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:39:03,922 INFO OK: read value = false
2026-02-02 15:39:03,922 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:39:03,922 INFO OK: read value = false
2026-02-02 15:39:03,923 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:39:03,923 INFO OK: read value = false
2026-02-02 15:39:03,923 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:39:03,923 INFO OK: read value = false
2026-02-02 15:39:03,923 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:39:03,923 INFO OK: read value = false
2026-02-02 15:39:03,923 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:39:03,923 INFO OK: read value = false
2026-02-02 15:39:03,924 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:39:03,924 INFO OK: read value = false
2026-02-02 15:39:03,924 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:39:03,924 INFO OK: read value = false
2026-02-02 15:39:03,924 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:39:03,924 INFO OK: read value = false
2026-02-02 15:39:03,924 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:39:03,924 INFO OK: read value = false
2026-02-02 15:39:03,924 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:39:03,925 INFO OK: read value = false
2026-02-02 15:39:03,925 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:39:03,925 INFO OK: read value = false
2026-02-02 15:39:03,925 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:39:03,925 INFO OK: read value = false
2026-02-02 15:39:03,925 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:39:03,925 INFO OK: read value = false
2026-02-02 15:39:03,925 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:39:03,925 INFO OK: read value = false
2026-02-02 15:39:03,926 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:39:03,926 INFO OK: read value = false
2026-02-02 15:39:03,926 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:39:03,926 INFO OK: read value = false
2026-02-02 15:39:03,926 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:39:03,926 INFO OK: read value = false
2026-02-02 15:39:03,926 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:39:03,926 INFO OK: read value = false
2026-02-02 15:39:03,927 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:39:03,927 INFO OK: read value = false
2026-02-02 15:39:03,927 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:39:03,927 INFO OK: read value = false
2026-02-02 15:39:03,927 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:39:03,927 INFO OK: read value = false
2026-02-02 15:39:03,927 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:39:03,927 INFO OK: read value = false
2026-02-02 15:39:03,928 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:39:03,928 INFO OK: read value = false
2026-02-02 15:39:03,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:39:03,928 INFO OK: read value = false
2026-02-02 15:39:03,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:39:03,928 INFO OK: read value = false
2026-02-02 15:39:03,928 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:39:03,928 INFO OK: read value = false
2026-02-02 15:39:03,929 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:39:03,930 INFO OK: read value = false
2026-02-02 15:39:03,930 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:39:03,930 INFO OK: read value = false
2026-02-02 15:39:03,930 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:39:03,931 INFO OK: read value = false
2026-02-02 15:39:03,931 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:39:03,931 INFO OK: read value = false
2026-02-02 15:39:03,931 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:39:03,931 INFO OK: read value = false
2026-02-02 15:39:03,931 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:39:03,931 INFO OK: read value = false
2026-02-02 15:39:03,931 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:39:03,931 INFO OK: read value = false
2026-02-02 15:39:03,932 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:39:03,932 INFO OK: read value = false
2026-02-02 15:39:03,932 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:39:03,932 INFO OK: read value = false
2026-02-02 15:39:03,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:39:03,933 INFO OK: read value = false
2026-02-02 15:39:03,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:39:03,933 INFO OK: read value = false
2026-02-02 15:39:03,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:39:03,933 INFO OK: read value = false
2026-02-02 15:39:03,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:39:03,933 INFO OK: read value = false
2026-02-02 15:39:03,933 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:39:03,934 INFO OK: read value = false
2026-02-02 15:39:03,934 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:39:03,934 INFO OK: read value = false
2026-02-02 15:39:03,934 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:39:03,934 INFO OK: read value = false
2026-02-02 15:39:03,934 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:39:03,934 INFO OK: read value = false
2026-02-02 15:39:03,934 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:39:03,934 INFO OK: read value = false
2026-02-02 15:39:03,934 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:39:03,934 INFO OK: read value = false
2026-02-02 15:39:03,934 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:39:03,934 INFO OK: read value = false
2026-02-02 15:39:03,935 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:39:03,935 INFO OK: read value = false
2026-02-02 15:39:03,935 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:39:03,935 INFO OK: read value = false
2026-02-02 15:39:03,935 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:39:03,935 INFO OK: read value = false
2026-02-02 15:39:03,935 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:39:03,935 INFO OK: read value = false
2026-02-02 15:39:03,935 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:39:03,935 INFO OK: read value = false
2026-02-02 15:39:03,936 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:39:03,936 INFO OK: read value = false
2026-02-02 15:39:03,936 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:39:03,936 INFO OK: read value = false
2026-02-02 15:39:03,936 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:39:03,936 INFO OK: read value = false
2026-02-02 15:39:03,936 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:39:03,936 INFO OK: read value = false
2026-02-02 15:39:03,936 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:39:03,937 INFO OK: read value = false
2026-02-02 15:39:03,937 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:39:03,937 INFO OK: read value = false
2026-02-02 15:39:03,937 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:39:03,937 INFO OK: read value = false
2026-02-02 15:39:03,937 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:39:03,937 INFO OK: read value = false
2026-02-02 15:39:03,937 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:39:03,937 INFO OK: read value = false
2026-02-02 15:39:03,937 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:39:03,937 INFO OK: read value = false
2026-02-02 15:39:03,937 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:39:03,940 INFO OK: read value = false
2026-02-02 15:39:03,940 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:39:03,941 INFO OK: read value = false
2026-02-02 15:39:03,941 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:39:03,943 INFO OK: read value = false
2026-02-02 15:39:03,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:39:03,943 INFO OK: read value = false
2026-02-02 15:39:03,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:39:03,943 INFO OK: read value = false
2026-02-02 15:39:03,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:39:03,943 INFO OK: read value = false
2026-02-02 15:39:03,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:39:03,943 INFO OK: read value = false
2026-02-02 15:39:03,943 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:39:03,943 INFO OK: read value = false
2026-02-02 15:39:03,944 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:39:03,944 INFO OK: read value = false
2026-02-02 15:39:03,944 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:39:03,944 INFO OK: read value = false
2026-02-02 15:39:03,944 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:39:03,944 INFO OK: read value = false
2026-02-02 15:39:03,945 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:39:03,945 INFO OK: read value = false
2026-02-02 15:39:03,945 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:39:03,945 INFO OK: read value = false
2026-02-02 15:39:03,946 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:39:03,946 INFO OK: read value = false
2026-02-02 15:39:03,946 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:39:03,946 INFO OK: read value = false
2026-02-02 15:39:03,946 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:39:03,946 INFO OK: read value = false
2026-02-02 15:39:03,946 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:39:03,947 INFO OK: read value = false
2026-02-02 15:39:03,947 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:39:03,947 INFO OK: read value = false
2026-02-02 15:39:03,947 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:39:03,947 INFO OK: read value = false
2026-02-02 15:39:03,948 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:39:03,948 INFO OK: read value = false
2026-02-02 15:39:03,948 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:39:03,948 INFO OK: read value = false
2026-02-02 15:39:03,948 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:39:03,948 INFO OK: read value = false
2026-02-02 15:39:03,948 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:39:03,948 INFO OK: read value = false
2026-02-02 15:39:03,949 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:39:03,949 INFO OK: read value = false
2026-02-02 15:39:03,949 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:39:03,949 INFO OK: read value = false
2026-02-02 15:39:03,949 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:39:03,949 INFO OK: read value = false
2026-02-02 15:39:03,949 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:39:03,949 INFO OK: read value = false
2026-02-02 15:39:03,949 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:39:03,949 INFO OK: read value = false
2026-02-02 15:39:03,950 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:39:03,950 INFO OK: read value = false
2026-02-02 15:39:03,950 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:39:03,950 INFO OK: read value = false
2026-02-02 15:39:03,950 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:39:03,950 INFO OK: read value = false
2026-02-02 15:39:03,950 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:39:03,950 INFO OK: read value = false
2026-02-02 15:39:03,950 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:39:03,951 INFO OK: read value = false
2026-02-02 15:39:03,951 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:39:03,951 INFO OK: read value = false
2026-02-02 15:39:03,951 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:39:03,951 INFO OK: read value = false
2026-02-02 15:39:03,951 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:39:03,952 INFO OK: read value = false
2026-02-02 15:39:03,952 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:39:03,952 INFO OK: read value = false
2026-02-02 15:39:03,952 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:39:03,953 INFO OK: read value = false
2026-02-02 15:39:03,953 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:39:03,953 INFO OK: read value = false
2026-02-02 15:39:03,954 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:39:03,954 INFO OK: read value = false
2026-02-02 15:39:03,954 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:39:03,954 INFO OK: read value = false
2026-02-02 15:39:03,954 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:39:03,954 INFO OK: read value = false
2026-02-02 15:39:03,954 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:39:03,954 INFO OK: read value = false
2026-02-02 15:39:03,954 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:39:03,955 INFO OK: read value = false
2026-02-02 15:39:03,955 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:39:03,955 INFO OK: read value = false
2026-02-02 15:39:03,955 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:39:03,955 INFO OK: read value = false
2026-02-02 15:39:03,955 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:39:03,955 INFO OK: read value = false
2026-02-02 15:39:03,955 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:39:03,955 INFO OK: read value = false
2026-02-02 15:39:03,955 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:39:03,955 INFO OK: read value = false
2026-02-02 15:39:03,955 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:39:03,956 INFO OK: read value = false
2026-02-02 15:39:03,956 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:39:03,956 INFO OK: read value = false
2026-02-02 15:39:03,956 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:39:03,956 INFO OK: read value = false
2026-02-02 15:39:03,956 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:39:03,956 INFO OK: read value = false
2026-02-02 15:39:03,957 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:39:03,957 INFO OK: read value = false
2026-02-02 15:39:03,957 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:39:03,957 INFO OK: read value = false
2026-02-02 15:39:03,957 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:39:03,957 INFO OK: read value = false
2026-02-02 15:39:03,958 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:39:03,958 INFO OK: read value = false
2026-02-02 15:39:03,958 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:39:03,958 INFO OK: read value = false
2026-02-02 15:39:03,959 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:39:03,959 INFO OK: read value = false
2026-02-02 15:39:03,959 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:39:03,959 INFO OK: read value = false
2026-02-02 15:39:03,959 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:39:03,959 INFO OK: read value = false
2026-02-02 15:39:03,960 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:39:03,960 INFO OK: read value = false
2026-02-02 15:39:03,960 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:39:03,961 INFO OK: read value = false
2026-02-02 15:39:03,962 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:39:03,962 INFO OK: read value = false
2026-02-02 15:39:03,963 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:39:03,963 INFO OK: read value = false
2026-02-02 15:39:03,963 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:39:03,963 INFO OK: read value = false
2026-02-02 15:39:03,963 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:39:03,963 INFO OK: read value = false
2026-02-02 15:39:03,964 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:39:03,964 INFO OK: read value = false
2026-02-02 15:39:03,964 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:39:03,964 INFO OK: read value = false
2026-02-02 15:39:03,965 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:39:03,965 INFO OK: read value = false
2026-02-02 15:39:03,965 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:39:03,965 INFO OK: read value = false
2026-02-02 15:39:03,966 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:39:03,966 INFO OK: read value = false
2026-02-02 15:39:03,966 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:39:03,966 INFO OK: read value = false
2026-02-02 15:39:03,966 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:39:03,966 INFO OK: read value = false
2026-02-02 15:39:03,966 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:39:03,967 INFO OK: read value = false
2026-02-02 15:39:03,967 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:39:03,967 INFO OK: read value = false
2026-02-02 15:39:03,967 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:39:03,968 INFO OK: read value = false
2026-02-02 15:39:03,968 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:39:03,969 INFO OK: read value = false
2026-02-02 15:39:03,969 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:39:03,969 INFO OK: read value = false
2026-02-02 15:39:03,969 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:39:03,969 INFO OK: read value = false
2026-02-02 15:39:03,969 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:39:03,969 INFO OK: read value = false
2026-02-02 15:39:03,969 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:39:03,969 INFO OK: read value = false
2026-02-02 15:39:03,969 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:39:03,969 INFO OK: read value = false
2026-02-02 15:39:03,970 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:39:03,970 INFO OK: read value = false
2026-02-02 15:39:03,970 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:39:03,970 INFO OK: read value = false
2026-02-02 15:39:03,970 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:39:03,970 INFO OK: read value = false
2026-02-02 15:39:03,970 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:39:03,970 INFO OK: read value = false
2026-02-02 15:39:03,970 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:39:03,970 INFO OK: read value = false
2026-02-02 15:39:03,970 INFO [Run 1] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:39:03,971 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:39:03,971 INFO 0.0s remaining ...
2026-02-02 15:39:03,971 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 15:39:03,971 INFO Target Detection Test
2026-02-02 15:39:03,971 INFO [Run 1] Starting target detection test (timeout: 5.0s)
2026-02-02 15:39:03,971 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:39:03,982 INFO TgtMsg: 1 1
2026-02-02 15:39:03,982 INFO Tgt: 1 @ 1180
2026-02-02 15:39:03,982 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:39:03,982 INFO OK: read value = 1
2026-02-02 15:39:03,983 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:39:03,983 INFO OK: read value = 1180
2026-02-02 15:39:03,983 INFO Target detected successfully in 0.01s
2026-02-02 15:39:03,983 INFO [Run 1] Target DETECTED in 0.01s
2026-02-02 15:39:03,984 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3
Total Step 194: Success 191 (98.45%), Failed 3 (1.55%),
2026-02-02 15:39:03,984 INFO Repetition 2 of 3
2026-02-02 15:39:03,984 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:39:03,984 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:39:04,984 INFO Set MAIN_POWER to False
2026-02-02 15:39:04,985 INFO [MOCK] Power OFF
2026-02-02 15:39:04,985 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:39:09,986 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:39:09,988 INFO OK: read value = False
2026-02-02 15:39:13,991 INFO The test operator is required to switch on the target.
2026-02-02 15:39:13,992 INFO Set MAIN_POWER to True
2026-02-02 15:39:13,993 INFO [MOCK] Power ON
2026-02-02 15:39:13,993 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:39:13,993 INFO run_count = 2
2026-02-02 15:39:13,994 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:39:13,994 INFO current_scenario = 'mixed'
2026-02-02 15:39:13,994 INFO _scenario_list = ['normal', 'mixed_b8_failures', 'receiver_fail']
2026-02-02 15:39:13,994 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:39:13,994 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='mixed_b8_failures'
2026-02-02 15:39:13,994 INFO [DEBUG] About to call _log_scenario_info('mixed_b8_failures', 2, 3)
2026-02-02 15:39:13,994 INFO
2026-02-02 15:39:13,995 INFO ####################################################################################################
2026-02-02 15:39:13,995 INFO ####################################################################################################
2026-02-02 15:39:13,995 INFO ### RUN 2/3: MIXED B8 TEST FAILURES
2026-02-02 15:39:13,995 INFO ####################################################################################################
2026-02-02 15:39:13,995 INFO
2026-02-02 15:39:13,996 INFO SCENARIO: mixed_b8_failures
2026-02-02 15:39:13,996 INFO DESCRIPTION: Random selection of individual B8 test failures across subsystems
2026-02-02 15:39:13,996 INFO
2026-02-02 15:39:13,996 INFO EXPECTED FAILURES:
2026-02-02 15:39:13,996 INFO ✗ Variable - random B8 tests from SP, TX, AGC, DP, IS categories
2026-02-02 15:39:13,996 INFO
2026-02-02 15:39:13,997 INFO EXPECTED PASSES:
2026-02-02 15:39:13,997 INFO ✓ B6 status fields (may show degradation)
2026-02-02 15:39:13,997 INFO ✓ Non-failed B8 tests
2026-02-02 15:39:13,997 INFO
2026-02-02 15:39:13,997 INFO NOTES: Best scenario to demonstrate test failure analysis with diverse test IDs
2026-02-02 15:39:13,997 INFO
2026-02-02 15:39:13,997 INFO ####################################################################################################
2026-02-02 15:39:13,998 INFO ####################################################################################################
2026-02-02 15:39:13,998 INFO
2026-02-02 15:39:13,998 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:39:13,998 INFO [MOCK APPLY] ✗ Mixed B8 test failures: SP5, TX10, AGC1, IS1
2026-02-02 15:39:13,999 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-02-02 15:39:18,999 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:39:19,000 INFO OK: read value = True
2026-02-02 15:39:19,100 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:39:19,301 INFO [MOCK] BIT report available after 5.3s
2026-02-02 15:39:19,322 INFO BIT report available after 0.2s
2026-02-02 15:39:19,323 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:39:19,323 INFO OK: read value = false
2026-02-02 15:39:19,323 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:39:19,323 DEBUG [MOCK] Field status: true
2026-02-02 15:39:19,324 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:19,324 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:19,324 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:39:19,324 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:39:19,324 INFO OK: read value = false
2026-02-02 15:39:19,324 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:39:19,325 INFO OK: read value = false
2026-02-02 15:39:19,325 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:39:19,325 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:19,325 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:19,325 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:39:19,325 INFO OK: read value = false
2026-02-02 15:39:19,325 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:39:19,325 INFO OK: read value = false
2026-02-02 15:39:19,326 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:39:19,326 INFO OK: read value = false
2026-02-02 15:39:19,326 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:39:19,326 INFO OK: read value = false
2026-02-02 15:39:19,326 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:39:19,326 INFO OK: read value = false
2026-02-02 15:39:19,327 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:39:19,327 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:19,327 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:19,327 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:39:19,327 WARNING CHECK ERROR: read value = RDR_FAIL
2026-02-02 15:39:19,327 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL
2026-02-02 15:39:19,327 WARNING Radar fail status: REAL failure (caused by: status, status, status)
2026-02-02 15:39:19,327 INFO [Run 2] B6 LRU Status: 12 total, 8 pass, 3 fail, 1 known
2026-02-02 15:39:19,328 INFO Known failures (HW setup): 1
2026-02-02 15:39:19,328 WARNING Real failures: status, status, status
2026-02-02 15:39:19,328 INFO
Drill-down: Verifying all 173 B8 diagnostic fields...
2026-02-02 15:39:19,328 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:39:19,328 INFO OK: read value = false
2026-02-02 15:39:19,329 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:39:19,329 INFO OK: read value = false
2026-02-02 15:39:19,329 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:39:19,329 INFO OK: read value = false
2026-02-02 15:39:19,329 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:39:19,329 INFO OK: read value = false
2026-02-02 15:39:19,329 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:39:19,330 INFO OK: read value = false
2026-02-02 15:39:19,330 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:39:19,330 INFO OK: read value = false
2026-02-02 15:39:19,330 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:39:19,330 INFO OK: read value = false
2026-02-02 15:39:19,330 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:39:19,330 INFO OK: read value = false
2026-02-02 15:39:19,331 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:39:19,331 INFO OK: read value = false
2026-02-02 15:39:19,331 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:39:19,331 WARNING CHECK ERROR: read value = 0
2026-02-02 15:39:19,331 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:39:19,331 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:39:19,331 INFO OK: read value = false
2026-02-02 15:39:19,332 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:39:19,332 INFO OK: read value = false
2026-02-02 15:39:19,332 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:39:19,332 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:39:19,332 INFO OK: read value = false
2026-02-02 15:39:19,332 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:39:19,333 INFO OK: read value = false
2026-02-02 15:39:19,333 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:39:19,333 INFO OK: read value = false
2026-02-02 15:39:19,333 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:39:19,333 INFO OK: read value = false
2026-02-02 15:39:19,333 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:39:19,334 INFO OK: read value = false
2026-02-02 15:39:19,334 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:39:19,334 INFO OK: read value = false
2026-02-02 15:39:19,334 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:39:19,334 INFO OK: read value = false
2026-02-02 15:39:19,335 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:39:19,335 INFO OK: read value = false
2026-02-02 15:39:19,335 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:39:19,335 INFO OK: read value = false
2026-02-02 15:39:19,335 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:39:19,336 INFO OK: read value = false
2026-02-02 15:39:19,336 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:39:19,336 INFO OK: read value = false
2026-02-02 15:39:19,336 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:39:19,336 INFO OK: read value = false
2026-02-02 15:39:19,336 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:39:19,337 INFO OK: read value = false
2026-02-02 15:39:19,337 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:39:19,337 INFO OK: read value = false
2026-02-02 15:39:19,337 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:39:19,337 INFO OK: read value = false
2026-02-02 15:39:19,337 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:39:19,337 INFO OK: read value = false
2026-02-02 15:39:19,338 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:39:19,338 INFO OK: read value = false
2026-02-02 15:39:19,338 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:39:19,338 INFO OK: read value = false
2026-02-02 15:39:19,338 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:39:19,338 INFO OK: read value = false
2026-02-02 15:39:19,338 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:39:19,339 INFO OK: read value = false
2026-02-02 15:39:19,339 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:39:19,340 INFO OK: read value = false
2026-02-02 15:39:19,340 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:39:19,340 INFO OK: read value = false
2026-02-02 15:39:19,340 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:39:19,341 INFO OK: read value = false
2026-02-02 15:39:19,341 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:39:19,341 INFO OK: read value = false
2026-02-02 15:39:19,341 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:39:19,341 INFO OK: read value = false
2026-02-02 15:39:19,341 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:39:19,341 INFO OK: read value = false
2026-02-02 15:39:19,342 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:39:19,342 INFO OK: read value = false
2026-02-02 15:39:19,342 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:39:19,342 INFO OK: read value = false
2026-02-02 15:39:19,342 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:39:19,342 INFO OK: read value = false
2026-02-02 15:39:19,343 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:39:19,344 INFO OK: read value = false
2026-02-02 15:39:19,344 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:39:19,344 INFO OK: read value = false
2026-02-02 15:39:19,344 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:39:19,344 INFO OK: read value = false
2026-02-02 15:39:19,345 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:39:19,345 INFO OK: read value = false
2026-02-02 15:39:19,345 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:39:19,345 INFO OK: read value = false
2026-02-02 15:39:19,345 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:39:19,345 INFO OK: read value = false
2026-02-02 15:39:19,345 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:39:19,345 INFO OK: read value = false
2026-02-02 15:39:19,346 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:39:19,346 INFO OK: read value = false
2026-02-02 15:39:19,346 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:39:19,346 INFO OK: read value = false
2026-02-02 15:39:19,346 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:39:19,346 INFO OK: read value = false
2026-02-02 15:39:19,346 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:39:19,347 INFO OK: read value = false
2026-02-02 15:39:19,347 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:39:19,347 INFO OK: read value = false
2026-02-02 15:39:19,347 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:39:19,347 INFO OK: read value = false
2026-02-02 15:39:19,347 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:39:19,347 INFO OK: read value = false
2026-02-02 15:39:19,348 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:39:19,348 INFO OK: read value = false
2026-02-02 15:39:19,348 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:39:19,348 INFO OK: read value = false
2026-02-02 15:39:19,348 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:39:19,349 INFO OK: read value = false
2026-02-02 15:39:19,349 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:39:19,349 INFO OK: read value = false
2026-02-02 15:39:19,349 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:39:19,349 INFO OK: read value = false
2026-02-02 15:39:19,349 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:39:19,350 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:19,350 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:19,350 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:39:19,350 INFO OK: read value = false
2026-02-02 15:39:19,350 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:39:19,350 INFO OK: read value = false
2026-02-02 15:39:19,350 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:39:19,351 INFO OK: read value = false
2026-02-02 15:39:19,351 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:39:19,351 INFO OK: read value = false
2026-02-02 15:39:19,351 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:39:19,351 INFO OK: read value = false
2026-02-02 15:39:19,351 WARNING B8_Test_AGC: 1/11 failures
2026-02-02 15:39:19,351 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:39:19,352 INFO OK: read value = false
2026-02-02 15:39:19,352 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:39:19,352 INFO OK: read value = false
2026-02-02 15:39:19,352 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:39:19,352 INFO OK: read value = false
2026-02-02 15:39:19,353 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:39:19,353 INFO OK: read value = false
2026-02-02 15:39:19,353 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:39:19,353 INFO OK: read value = false
2026-02-02 15:39:19,353 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:39:19,353 INFO OK: read value = false
2026-02-02 15:39:19,354 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:39:19,354 INFO OK: read value = false
2026-02-02 15:39:19,354 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:39:19,354 INFO OK: read value = false
2026-02-02 15:39:19,355 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:39:19,355 INFO OK: read value = false
2026-02-02 15:39:19,355 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:39:19,355 INFO OK: read value = false
2026-02-02 15:39:19,355 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:39:19,356 INFO OK: read value = false
2026-02-02 15:39:19,356 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:39:19,356 INFO OK: read value = false
2026-02-02 15:39:19,356 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:39:19,356 INFO OK: read value = false
2026-02-02 15:39:19,356 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:39:19,356 INFO OK: read value = false
2026-02-02 15:39:19,356 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:39:19,356 INFO OK: read value = false
2026-02-02 15:39:19,357 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:39:19,357 INFO OK: read value = false
2026-02-02 15:39:19,357 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:39:19,357 INFO OK: read value = false
2026-02-02 15:39:19,357 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:39:19,357 INFO OK: read value = false
2026-02-02 15:39:19,358 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:39:19,358 INFO OK: read value = false
2026-02-02 15:39:19,358 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:39:19,358 INFO OK: read value = false
2026-02-02 15:39:19,358 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:39:19,358 INFO OK: read value = false
2026-02-02 15:39:19,358 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:39:19,359 INFO OK: read value = false
2026-02-02 15:39:19,359 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:39:19,359 INFO OK: read value = false
2026-02-02 15:39:19,359 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:39:19,359 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:19,359 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:19,359 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:39:19,359 INFO OK: read value = false
2026-02-02 15:39:19,360 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:39:19,360 INFO OK: read value = false
2026-02-02 15:39:19,360 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:39:19,360 INFO OK: read value = false
2026-02-02 15:39:19,360 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:39:19,360 INFO OK: read value = false
2026-02-02 15:39:19,360 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:39:19,361 INFO OK: read value = false
2026-02-02 15:39:19,361 WARNING B8_Test_IntegratedSystem: 1/15 failures
2026-02-02 15:39:19,361 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:39:19,361 INFO OK: read value = false
2026-02-02 15:39:19,361 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:39:19,361 INFO OK: read value = false
2026-02-02 15:39:19,361 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:39:19,362 INFO OK: read value = false
2026-02-02 15:39:19,362 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:39:19,362 INFO OK: read value = false
2026-02-02 15:39:19,362 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:39:19,362 INFO OK: read value = false
2026-02-02 15:39:19,363 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:39:19,363 INFO OK: read value = false
2026-02-02 15:39:19,363 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:39:19,363 INFO OK: read value = false
2026-02-02 15:39:19,363 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:39:19,363 INFO OK: read value = false
2026-02-02 15:39:19,363 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:39:19,363 INFO OK: read value = false
2026-02-02 15:39:19,364 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:39:19,364 INFO OK: read value = false
2026-02-02 15:39:19,364 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:39:19,364 INFO OK: read value = false
2026-02-02 15:39:19,364 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:39:19,365 INFO OK: read value = false
2026-02-02 15:39:19,365 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:39:19,365 INFO OK: read value = false
2026-02-02 15:39:19,365 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:39:19,365 INFO OK: read value = false
2026-02-02 15:39:19,365 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:39:19,365 INFO OK: read value = false
2026-02-02 15:39:19,365 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:39:19,365 INFO OK: read value = false
2026-02-02 15:39:19,366 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:39:19,366 INFO OK: read value = false
2026-02-02 15:39:19,366 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:39:19,366 INFO OK: read value = false
2026-02-02 15:39:19,366 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:39:19,367 INFO OK: read value = false
2026-02-02 15:39:19,367 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:39:19,367 INFO OK: read value = false
2026-02-02 15:39:19,367 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:39:19,367 INFO OK: read value = false
2026-02-02 15:39:19,368 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:39:19,368 INFO OK: read value = false
2026-02-02 15:39:19,368 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:39:19,368 INFO OK: read value = false
2026-02-02 15:39:19,368 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:39:19,368 INFO OK: read value = false
2026-02-02 15:39:19,369 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:39:19,369 INFO OK: read value = false
2026-02-02 15:39:19,369 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:39:19,369 INFO OK: read value = false
2026-02-02 15:39:19,369 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:39:19,369 INFO OK: read value = false
2026-02-02 15:39:19,370 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:39:19,370 INFO OK: read value = false
2026-02-02 15:39:19,370 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:39:19,370 INFO OK: read value = false
2026-02-02 15:39:19,370 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:39:19,370 INFO OK: read value = false
2026-02-02 15:39:19,371 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:39:19,371 INFO OK: read value = false
2026-02-02 15:39:19,371 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:39:19,371 INFO OK: read value = false
2026-02-02 15:39:19,371 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:39:19,371 INFO OK: read value = false
2026-02-02 15:39:19,371 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:39:19,372 INFO OK: read value = false
2026-02-02 15:39:19,372 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:39:19,372 INFO OK: read value = false
2026-02-02 15:39:19,372 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:39:19,372 INFO OK: read value = false
2026-02-02 15:39:19,372 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:39:19,372 INFO OK: read value = false
2026-02-02 15:39:19,372 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:39:19,373 INFO OK: read value = false
2026-02-02 15:39:19,373 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:39:19,373 INFO OK: read value = false
2026-02-02 15:39:19,373 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:39:19,373 INFO OK: read value = false
2026-02-02 15:39:19,373 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:39:19,373 INFO OK: read value = false
2026-02-02 15:39:19,374 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:39:19,374 INFO OK: read value = false
2026-02-02 15:39:19,374 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:39:19,374 INFO OK: read value = false
2026-02-02 15:39:19,374 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:39:19,374 INFO OK: read value = false
2026-02-02 15:39:19,374 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:39:19,374 INFO OK: read value = false
2026-02-02 15:39:19,375 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:39:19,375 INFO OK: read value = false
2026-02-02 15:39:19,375 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:39:19,375 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:19,375 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:19,375 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:39:19,375 INFO OK: read value = false
2026-02-02 15:39:19,376 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:39:19,376 INFO OK: read value = false
2026-02-02 15:39:19,376 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:39:19,376 INFO OK: read value = false
2026-02-02 15:39:19,376 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:39:19,377 INFO OK: read value = false
2026-02-02 15:39:19,377 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:39:19,377 INFO OK: read value = false
2026-02-02 15:39:19,377 WARNING B8_Test_SignalProcessor: 1/14 failures
2026-02-02 15:39:19,377 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:39:19,378 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:19,378 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:19,378 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:39:19,378 INFO OK: read value = false
2026-02-02 15:39:19,378 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:39:19,378 INFO OK: read value = false
2026-02-02 15:39:19,378 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:39:19,379 INFO OK: read value = false
2026-02-02 15:39:19,379 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:39:19,379 INFO OK: read value = false
2026-02-02 15:39:19,379 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:39:19,379 INFO OK: read value = false
2026-02-02 15:39:19,379 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:39:19,379 INFO OK: read value = false
2026-02-02 15:39:19,379 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:39:19,380 INFO OK: read value = false
2026-02-02 15:39:19,380 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:39:19,380 INFO OK: read value = false
2026-02-02 15:39:19,381 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:39:19,381 INFO OK: read value = false
2026-02-02 15:39:19,381 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:39:19,381 INFO OK: read value = false
2026-02-02 15:39:19,381 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:39:19,382 INFO OK: read value = false
2026-02-02 15:39:19,382 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:39:19,382 INFO OK: read value = false
2026-02-02 15:39:19,382 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:39:19,382 INFO OK: read value = false
2026-02-02 15:39:19,382 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:39:19,383 INFO OK: read value = false
2026-02-02 15:39:19,383 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:39:19,383 INFO OK: read value = false
2026-02-02 15:39:19,383 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:39:19,383 INFO OK: read value = false
2026-02-02 15:39:19,384 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:39:19,384 INFO OK: read value = false
2026-02-02 15:39:19,384 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:39:19,384 INFO OK: read value = false
2026-02-02 15:39:19,384 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:39:19,385 INFO OK: read value = false
2026-02-02 15:39:19,385 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:39:19,385 INFO OK: read value = false
2026-02-02 15:39:19,385 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:39:19,385 INFO OK: read value = false
2026-02-02 15:39:19,385 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:39:19,386 INFO OK: read value = false
2026-02-02 15:39:19,386 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:39:19,386 INFO OK: read value = false
2026-02-02 15:39:19,386 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:39:19,386 INFO OK: read value = false
2026-02-02 15:39:19,386 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:39:19,386 INFO OK: read value = false
2026-02-02 15:39:19,387 WARNING B8_Test_Transmitter: 1/26 failures
2026-02-02 15:39:19,387 INFO [Run 2] B8 Diagnostics: 173 checked, 168 pass, 5 fail
2026-02-02 15:39:19,387 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:39:19,387 WARNING B8_Test_AGC: 1 failures - ram
2026-02-02 15:39:19,387 WARNING B8_Test_IntegratedSystem: 1 failures - levels
2026-02-02 15:39:19,387 WARNING B8_Test_SignalProcessor: 1 failures - ad
2026-02-02 15:39:19,388 WARNING B8_Test_Transmitter: 1 failures - warning
2026-02-02 15:39:19,388 INFO 0.0s remaining ...
2026-02-02 15:39:19,388 INFO [Run 2] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 15:39:19,388 INFO Target Detection Test
2026-02-02 15:39:19,388 INFO [Run 2] Starting target detection test (timeout: 5.0s)
2026-02-02 15:39:19,388 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:39:19,399 INFO TgtMsg: 2 2
2026-02-02 15:39:19,399 INFO Tgt: 1 @ 1180
2026-02-02 15:39:19,399 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:39:19,400 INFO OK: read value = 1
2026-02-02 15:39:19,400 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:39:19,400 INFO OK: read value = 1180
2026-02-02 15:39:19,400 INFO Target detected successfully in 0.01s
2026-02-02 15:39:19,400 INFO [Run 2] Target DETECTED in 0.01s
2026-02-02 15:39:19,401 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3
Total Step 192: Success 183 (95.31%), Failed 9 (4.69%),
2026-02-02 15:39:19,401 INFO Repetition 3 of 3
2026-02-02 15:39:19,401 DEBUG [MOCK] Serial statistics reset
2026-02-02 15:39:19,401 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-02 15:39:20,402 INFO Set MAIN_POWER to False
2026-02-02 15:39:20,402 INFO [MOCK] Power OFF
2026-02-02 15:39:20,402 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:39:25,403 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:39:25,404 INFO OK: read value = False
2026-02-02 15:39:29,405 INFO The test operator is required to switch on the target.
2026-02-02 15:39:29,406 INFO Set MAIN_POWER to True
2026-02-02 15:39:29,406 INFO [MOCK] Power ON
2026-02-02 15:39:29,407 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-02 15:39:29,408 INFO run_count = 3
2026-02-02 15:39:29,408 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-02 15:39:29,408 INFO current_scenario = 'mixed'
2026-02-02 15:39:29,408 INFO _scenario_list = ['normal', 'mixed_b8_failures', 'receiver_fail']
2026-02-02 15:39:29,409 INFO [DEBUG] Entering MIXED MODE branch
2026-02-02 15:39:29,409 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='receiver_fail'
2026-02-02 15:39:29,410 INFO [DEBUG] About to call _log_scenario_info('receiver_fail', 3, 3)
2026-02-02 15:39:29,411 INFO
2026-02-02 15:39:29,411 INFO ####################################################################################################
2026-02-02 15:39:29,412 INFO ####################################################################################################
2026-02-02 15:39:29,412 INFO ### RUN 3/3: RECEIVER FAILURE
2026-02-02 15:39:29,412 INFO ####################################################################################################
2026-02-02 15:39:29,412 INFO
2026-02-02 15:39:29,412 INFO SCENARIO: receiver_fail
2026-02-02 15:39:29,413 INFO DESCRIPTION: Receiver subsystem failure detected
2026-02-02 15:39:29,413 INFO
2026-02-02 15:39:29,413 INFO EXPECTED FAILURES:
2026-02-02 15:39:29,413 INFO ✗ B6: receiver_status = FAIL
2026-02-02 15:39:29,413 INFO ✗ B6: radar_fail_status = RDR_FAIL
2026-02-02 15:39:29,413 INFO
2026-02-02 15:39:29,414 INFO EXPECTED PASSES:
2026-02-02 15:39:29,414 INFO ✓ Other B6 fields
2026-02-02 15:39:29,414 INFO ✓ B8 diagnostic fields
2026-02-02 15:39:29,414 INFO ✓ Target generation
2026-02-02 15:39:29,414 INFO
2026-02-02 15:39:29,414 INFO NOTES: Test should detect receiver failure and trigger B8 drill-down
2026-02-02 15:39:29,415 INFO
2026-02-02 15:39:29,415 INFO ####################################################################################################
2026-02-02 15:39:29,415 INFO ####################################################################################################
2026-02-02 15:39:29,415 INFO
2026-02-02 15:39:29,415 INFO [DEBUG] _log_scenario_info() completed
2026-02-02 15:39:29,416 INFO [MOCK APPLY] ✗ Setting receiver_status = FAIL
2026-02-02 15:39:29,416 INFO [MOCK APPLY] ✗ Setting radar_fail_status = RDR_FAIL
2026-02-02 15:39:29,416 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3)
2026-02-02 15:39:34,416 INFO Check that MAIN_POWER is equal to 1
2026-02-02 15:39:34,417 INFO OK: read value = True
2026-02-02 15:39:34,517 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-02 15:39:34,718 INFO [MOCK] BIT report available after 5.3s
2026-02-02 15:39:34,738 INFO BIT report available after 0.2s
2026-02-02 15:39:34,739 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-02 15:39:34,739 INFO OK: read value = false
2026-02-02 15:39:34,739 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-02 15:39:34,739 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:34,739 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:34,740 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-02 15:39:34,740 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-02 15:39:34,740 INFO OK: read value = false
2026-02-02 15:39:34,740 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-02 15:39:34,740 INFO OK: read value = false
2026-02-02 15:39:34,740 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-02 15:39:34,741 INFO OK: read value = false
2026-02-02 15:39:34,741 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-02 15:39:34,741 WARNING CHECK ERROR: read value = true
2026-02-02 15:39:34,741 ERROR INTERFACE ERROR: Expected false, got true
2026-02-02 15:39:34,741 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-02 15:39:34,741 INFO OK: read value = false
2026-02-02 15:39:34,742 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-02 15:39:34,742 INFO OK: read value = false
2026-02-02 15:39:34,742 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-02 15:39:34,742 INFO OK: read value = false
2026-02-02 15:39:34,742 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-02 15:39:34,742 INFO OK: read value = false
2026-02-02 15:39:34,742 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-02 15:39:34,743 INFO OK: read value = false
2026-02-02 15:39:34,743 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-02 15:39:34,743 WARNING CHECK ERROR: read value = RDR_FAIL
2026-02-02 15:39:34,743 ERROR INTERFACE ERROR: Expected false, got RDR_FAIL
2026-02-02 15:39:34,743 WARNING Radar fail status: REAL failure (caused by: status, status)
2026-02-02 15:39:34,743 INFO [Run 3] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known
2026-02-02 15:39:34,743 INFO Known failures (HW setup): 1
2026-02-02 15:39:34,744 WARNING Real failures: status, status
2026-02-02 15:39:34,744 INFO
Drill-down: Verifying all 173 B8 diagnostic fields...
2026-02-02 15:39:34,744 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-02 15:39:34,746 INFO OK: read value = false
2026-02-02 15:39:34,746 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-02 15:39:34,747 INFO OK: read value = false
2026-02-02 15:39:34,747 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-02 15:39:34,748 INFO OK: read value = false
2026-02-02 15:39:34,748 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-02 15:39:34,749 INFO OK: read value = false
2026-02-02 15:39:34,749 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-02 15:39:34,749 INFO OK: read value = false
2026-02-02 15:39:34,749 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-02 15:39:34,749 INFO OK: read value = false
2026-02-02 15:39:34,749 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-02 15:39:34,750 INFO OK: read value = false
2026-02-02 15:39:34,750 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-02 15:39:34,750 INFO OK: read value = false
2026-02-02 15:39:34,750 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-02 15:39:34,751 INFO OK: read value = false
2026-02-02 15:39:34,751 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-02 15:39:34,751 WARNING CHECK ERROR: read value = 0
2026-02-02 15:39:34,751 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-02 15:39:34,752 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-02 15:39:34,752 INFO OK: read value = false
2026-02-02 15:39:34,752 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-02 15:39:34,752 INFO OK: read value = false
2026-02-02 15:39:34,752 WARNING B8_Degradation: 1/12 failures
2026-02-02 15:39:34,752 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-02 15:39:34,752 INFO OK: read value = false
2026-02-02 15:39:34,753 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-02 15:39:34,753 INFO OK: read value = false
2026-02-02 15:39:34,753 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-02 15:39:34,753 INFO OK: read value = false
2026-02-02 15:39:34,753 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-02 15:39:34,754 INFO OK: read value = false
2026-02-02 15:39:34,754 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-02 15:39:34,754 INFO OK: read value = false
2026-02-02 15:39:34,754 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-02 15:39:34,754 INFO OK: read value = false
2026-02-02 15:39:34,755 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-02 15:39:34,755 INFO OK: read value = false
2026-02-02 15:39:34,755 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-02 15:39:34,755 INFO OK: read value = false
2026-02-02 15:39:34,755 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-02 15:39:34,755 INFO OK: read value = false
2026-02-02 15:39:34,755 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-02 15:39:34,756 INFO OK: read value = false
2026-02-02 15:39:34,756 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-02 15:39:34,756 INFO OK: read value = false
2026-02-02 15:39:34,756 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-02 15:39:34,756 INFO OK: read value = false
2026-02-02 15:39:34,756 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-02 15:39:34,757 INFO OK: read value = false
2026-02-02 15:39:34,757 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-02 15:39:34,757 INFO OK: read value = false
2026-02-02 15:39:34,757 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-02 15:39:34,757 INFO OK: read value = false
2026-02-02 15:39:34,757 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-02 15:39:34,757 INFO OK: read value = false
2026-02-02 15:39:34,758 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-02 15:39:34,758 INFO OK: read value = false
2026-02-02 15:39:34,758 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-02 15:39:34,758 INFO OK: read value = false
2026-02-02 15:39:34,758 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-02 15:39:34,758 INFO OK: read value = false
2026-02-02 15:39:34,758 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-02 15:39:34,759 INFO OK: read value = false
2026-02-02 15:39:34,759 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-02 15:39:34,759 INFO OK: read value = false
2026-02-02 15:39:34,759 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-02 15:39:34,759 INFO OK: read value = false
2026-02-02 15:39:34,759 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-02 15:39:34,759 INFO OK: read value = false
2026-02-02 15:39:34,759 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-02 15:39:34,759 INFO OK: read value = false
2026-02-02 15:39:34,760 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-02 15:39:34,760 INFO OK: read value = false
2026-02-02 15:39:34,760 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-02 15:39:34,760 INFO OK: read value = false
2026-02-02 15:39:34,761 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-02 15:39:34,761 INFO OK: read value = false
2026-02-02 15:39:34,761 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-02 15:39:34,761 INFO OK: read value = false
2026-02-02 15:39:34,761 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-02 15:39:34,761 INFO OK: read value = false
2026-02-02 15:39:34,762 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-02 15:39:34,763 INFO OK: read value = false
2026-02-02 15:39:34,763 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-02 15:39:34,763 INFO OK: read value = false
2026-02-02 15:39:34,763 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-02 15:39:34,763 INFO OK: read value = false
2026-02-02 15:39:34,763 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-02 15:39:34,764 INFO OK: read value = false
2026-02-02 15:39:34,764 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-02 15:39:34,764 INFO OK: read value = false
2026-02-02 15:39:34,764 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-02 15:39:34,764 INFO OK: read value = false
2026-02-02 15:39:34,764 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-02 15:39:34,764 INFO OK: read value = false
2026-02-02 15:39:34,764 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-02 15:39:34,764 INFO OK: read value = false
2026-02-02 15:39:34,765 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-02 15:39:34,765 INFO OK: read value = false
2026-02-02 15:39:34,765 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-02 15:39:34,765 INFO OK: read value = false
2026-02-02 15:39:34,765 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-02 15:39:34,765 INFO OK: read value = false
2026-02-02 15:39:34,765 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-02 15:39:34,766 INFO OK: read value = false
2026-02-02 15:39:34,766 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-02 15:39:34,766 INFO OK: read value = false
2026-02-02 15:39:34,767 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-02 15:39:34,767 INFO OK: read value = false
2026-02-02 15:39:34,767 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-02 15:39:34,767 INFO OK: read value = false
2026-02-02 15:39:34,767 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-02 15:39:34,767 INFO OK: read value = false
2026-02-02 15:39:34,768 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-02 15:39:34,768 INFO OK: read value = false
2026-02-02 15:39:34,768 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-02 15:39:34,768 INFO OK: read value = false
2026-02-02 15:39:34,768 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-02 15:39:34,768 INFO OK: read value = false
2026-02-02 15:39:34,768 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-02 15:39:34,769 INFO OK: read value = false
2026-02-02 15:39:34,769 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-02 15:39:34,769 INFO OK: read value = false
2026-02-02 15:39:34,769 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-02 15:39:34,769 INFO OK: read value = false
2026-02-02 15:39:34,769 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-02 15:39:34,770 INFO OK: read value = false
2026-02-02 15:39:34,770 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-02 15:39:34,770 INFO OK: read value = false
2026-02-02 15:39:34,770 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-02 15:39:34,770 INFO OK: read value = false
2026-02-02 15:39:34,771 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-02 15:39:34,771 INFO OK: read value = false
2026-02-02 15:39:34,771 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-02 15:39:34,771 INFO OK: read value = false
2026-02-02 15:39:34,772 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-02 15:39:34,772 INFO OK: read value = false
2026-02-02 15:39:34,773 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-02 15:39:34,774 INFO OK: read value = false
2026-02-02 15:39:34,774 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-02 15:39:34,775 INFO OK: read value = false
2026-02-02 15:39:34,775 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-02 15:39:34,775 INFO OK: read value = false
2026-02-02 15:39:34,776 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-02 15:39:34,776 INFO OK: read value = false
2026-02-02 15:39:34,776 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-02 15:39:34,776 INFO OK: read value = false
2026-02-02 15:39:34,776 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-02 15:39:34,776 INFO OK: read value = false
2026-02-02 15:39:34,776 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-02 15:39:34,777 INFO OK: read value = false
2026-02-02 15:39:34,777 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-02 15:39:34,777 INFO OK: read value = false
2026-02-02 15:39:34,777 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-02 15:39:34,777 INFO OK: read value = false
2026-02-02 15:39:34,777 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-02 15:39:34,777 INFO OK: read value = false
2026-02-02 15:39:34,777 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-02 15:39:34,777 INFO OK: read value = false
2026-02-02 15:39:34,778 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-02 15:39:34,778 INFO OK: read value = false
2026-02-02 15:39:34,778 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-02 15:39:34,778 INFO OK: read value = false
2026-02-02 15:39:34,779 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-02 15:39:34,779 INFO OK: read value = false
2026-02-02 15:39:34,779 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-02 15:39:34,779 INFO OK: read value = false
2026-02-02 15:39:34,780 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-02 15:39:34,780 INFO OK: read value = false
2026-02-02 15:39:34,780 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-02 15:39:34,781 INFO OK: read value = false
2026-02-02 15:39:34,781 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-02 15:39:34,781 INFO OK: read value = false
2026-02-02 15:39:34,781 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-02 15:39:34,782 INFO OK: read value = false
2026-02-02 15:39:34,782 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-02 15:39:34,782 INFO OK: read value = false
2026-02-02 15:39:34,782 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-02 15:39:34,783 INFO OK: read value = false
2026-02-02 15:39:34,783 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-02 15:39:34,783 INFO OK: read value = false
2026-02-02 15:39:34,783 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-02 15:39:34,783 INFO OK: read value = false
2026-02-02 15:39:34,783 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-02 15:39:34,783 INFO OK: read value = false
2026-02-02 15:39:34,784 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-02 15:39:34,784 INFO OK: read value = false
2026-02-02 15:39:34,784 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-02 15:39:34,784 INFO OK: read value = false
2026-02-02 15:39:34,784 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-02 15:39:34,785 INFO OK: read value = false
2026-02-02 15:39:34,785 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-02 15:39:34,785 INFO OK: read value = false
2026-02-02 15:39:34,785 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-02 15:39:34,785 INFO OK: read value = false
2026-02-02 15:39:34,786 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-02 15:39:34,786 INFO OK: read value = false
2026-02-02 15:39:34,786 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-02 15:39:34,786 INFO OK: read value = false
2026-02-02 15:39:34,786 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-02 15:39:34,787 INFO OK: read value = false
2026-02-02 15:39:34,787 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-02 15:39:34,787 INFO OK: read value = false
2026-02-02 15:39:34,787 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-02 15:39:34,788 INFO OK: read value = false
2026-02-02 15:39:34,788 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-02 15:39:34,788 INFO OK: read value = false
2026-02-02 15:39:34,788 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-02 15:39:34,788 INFO OK: read value = false
2026-02-02 15:39:34,789 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-02 15:39:34,789 INFO OK: read value = false
2026-02-02 15:39:34,789 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-02 15:39:34,789 INFO OK: read value = false
2026-02-02 15:39:34,789 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-02 15:39:34,790 INFO OK: read value = false
2026-02-02 15:39:34,790 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-02 15:39:34,790 INFO OK: read value = false
2026-02-02 15:39:34,790 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-02 15:39:34,790 INFO OK: read value = false
2026-02-02 15:39:34,790 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-02 15:39:34,790 INFO OK: read value = false
2026-02-02 15:39:34,790 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-02 15:39:34,790 INFO OK: read value = false
2026-02-02 15:39:34,791 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-02 15:39:34,791 INFO OK: read value = false
2026-02-02 15:39:34,791 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-02 15:39:34,791 INFO OK: read value = false
2026-02-02 15:39:34,791 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-02 15:39:34,791 INFO OK: read value = false
2026-02-02 15:39:34,791 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-02 15:39:34,791 INFO OK: read value = false
2026-02-02 15:39:34,792 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-02 15:39:34,792 INFO OK: read value = false
2026-02-02 15:39:34,792 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-02 15:39:34,792 INFO OK: read value = false
2026-02-02 15:39:34,792 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-02 15:39:34,792 INFO OK: read value = false
2026-02-02 15:39:34,793 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-02 15:39:34,793 INFO OK: read value = false
2026-02-02 15:39:34,793 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-02 15:39:34,793 INFO OK: read value = false
2026-02-02 15:39:34,794 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-02 15:39:34,794 INFO OK: read value = false
2026-02-02 15:39:34,794 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-02 15:39:34,794 INFO OK: read value = false
2026-02-02 15:39:34,794 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-02 15:39:34,795 INFO OK: read value = false
2026-02-02 15:39:34,795 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-02 15:39:34,795 INFO OK: read value = false
2026-02-02 15:39:34,795 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-02 15:39:34,795 INFO OK: read value = false
2026-02-02 15:39:34,795 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-02 15:39:34,795 INFO OK: read value = false
2026-02-02 15:39:34,795 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-02 15:39:34,796 INFO OK: read value = false
2026-02-02 15:39:34,796 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-02 15:39:34,796 INFO OK: read value = false
2026-02-02 15:39:34,796 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-02 15:39:34,797 INFO OK: read value = false
2026-02-02 15:39:34,797 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-02 15:39:34,797 INFO OK: read value = false
2026-02-02 15:39:34,797 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-02 15:39:34,798 INFO OK: read value = false
2026-02-02 15:39:34,798 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-02 15:39:34,798 INFO OK: read value = false
2026-02-02 15:39:34,798 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-02 15:39:34,799 INFO OK: read value = false
2026-02-02 15:39:34,799 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-02 15:39:34,799 INFO OK: read value = false
2026-02-02 15:39:34,799 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-02 15:39:34,800 INFO OK: read value = false
2026-02-02 15:39:34,800 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-02 15:39:34,800 INFO OK: read value = false
2026-02-02 15:39:34,800 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-02 15:39:34,801 INFO OK: read value = false
2026-02-02 15:39:34,803 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-02 15:39:34,803 INFO OK: read value = false
2026-02-02 15:39:34,803 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-02 15:39:34,804 INFO OK: read value = false
2026-02-02 15:39:34,804 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-02 15:39:34,804 INFO OK: read value = false
2026-02-02 15:39:34,804 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-02 15:39:34,804 INFO OK: read value = false
2026-02-02 15:39:34,804 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-02 15:39:34,804 INFO OK: read value = false
2026-02-02 15:39:34,805 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-02 15:39:34,805 INFO OK: read value = false
2026-02-02 15:39:34,805 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-02 15:39:34,805 INFO OK: read value = false
2026-02-02 15:39:34,806 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-02 15:39:34,806 INFO OK: read value = false
2026-02-02 15:39:34,806 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-02 15:39:34,806 INFO OK: read value = false
2026-02-02 15:39:34,806 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-02 15:39:34,806 INFO OK: read value = false
2026-02-02 15:39:34,806 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-02 15:39:34,806 INFO OK: read value = false
2026-02-02 15:39:34,806 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-02 15:39:34,806 INFO OK: read value = false
2026-02-02 15:39:34,807 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-02 15:39:34,807 INFO OK: read value = false
2026-02-02 15:39:34,807 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-02 15:39:34,807 INFO OK: read value = false
2026-02-02 15:39:34,807 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-02 15:39:34,808 INFO OK: read value = false
2026-02-02 15:39:34,808 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-02 15:39:34,808 INFO OK: read value = false
2026-02-02 15:39:34,810 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-02 15:39:34,810 INFO OK: read value = false
2026-02-02 15:39:34,810 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-02 15:39:34,810 INFO OK: read value = false
2026-02-02 15:39:34,810 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-02 15:39:34,810 INFO OK: read value = false
2026-02-02 15:39:34,811 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-02 15:39:34,811 INFO OK: read value = false
2026-02-02 15:39:34,811 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-02 15:39:34,811 INFO OK: read value = false
2026-02-02 15:39:34,811 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-02 15:39:34,812 INFO OK: read value = false
2026-02-02 15:39:34,812 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-02 15:39:34,813 INFO OK: read value = false
2026-02-02 15:39:34,813 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-02 15:39:34,813 INFO OK: read value = false
2026-02-02 15:39:34,813 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-02 15:39:34,814 INFO OK: read value = false
2026-02-02 15:39:34,814 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-02 15:39:34,814 INFO OK: read value = false
2026-02-02 15:39:34,814 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-02 15:39:34,815 INFO OK: read value = false
2026-02-02 15:39:34,815 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-02 15:39:34,816 INFO OK: read value = false
2026-02-02 15:39:34,816 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-02 15:39:34,817 INFO OK: read value = false
2026-02-02 15:39:34,817 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-02 15:39:34,817 INFO OK: read value = false
2026-02-02 15:39:34,817 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-02 15:39:34,818 INFO OK: read value = false
2026-02-02 15:39:34,818 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-02 15:39:34,819 INFO OK: read value = false
2026-02-02 15:39:34,819 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-02 15:39:34,819 INFO OK: read value = false
2026-02-02 15:39:34,819 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-02 15:39:34,819 INFO OK: read value = false
2026-02-02 15:39:34,820 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-02 15:39:34,820 INFO OK: read value = false
2026-02-02 15:39:34,820 INFO [Run 3] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-02 15:39:34,820 WARNING B8_Degradation: 1 failures - fail
2026-02-02 15:39:34,820 INFO 0.0s remaining ...
2026-02-02 15:39:34,821 INFO [Run 3] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-02 15:39:34,821 INFO Target Detection Test
2026-02-02 15:39:34,821 INFO [Run 3] Starting target detection test (timeout: 5.0s)
2026-02-02 15:39:34,821 INFO tgt_gen() - timeout: 5.0s
2026-02-02 15:39:34,834 INFO TgtMsg: 3 3
2026-02-02 15:39:34,834 INFO Tgt: 1 @ 1180
2026-02-02 15:39:34,835 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-02 15:39:34,835 INFO OK: read value = 1
2026-02-02 15:39:34,835 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-02 15:39:34,835 DEBUG [MOCK] Field rng: 1180
2026-02-02 15:39:34,835 INFO OK: read value = 1180
2026-02-02 15:39:34,836 INFO Target detected successfully in 0.01s
2026-02-02 15:39:34,836 INFO [Run 3] Target DETECTED in 0.01s
2026-02-02 15:39:34,837 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3
Total Step 192: Success 188 (97.92%), Failed 4 (2.08%),
2026-02-02 15:39:34,837 INFO Repetitions terminated.
2026-02-02 15:39:34,837 INFO [Report] Custom statistics data registered for PDF generation
2026-02-02 15:39:34,837 INFO ==========================================================================================
2026-02-02 15:39:34,838 INFO FINAL TEST STATISTICS SUMMARY
2026-02-02 15:39:34,838 INFO ==========================================================================================
2026-02-02 15:39:34,838 INFO Total Runs: 3
2026-02-02 15:39:34,839 INFO Successful: 1 (33.3%)
2026-02-02 15:39:34,839 INFO Failed: 2 (66.7%)
2026-02-02 15:39:34,839 INFO B6 Checks: 36 (Pass: 27, Fail: 5, Known: 4)
2026-02-02 15:39:34,839 INFO B8 Checks: 519 (Pass: 512, Fail: 7)
2026-02-02 15:39:34,839 INFO Serial: 0 messages (0 errors, 0 fatal, 0 recycles)
2026-02-02 15:39:34,839 INFO Target: 3 detected, 0 not detected (100.0% pass rate)
2026-02-02 15:39:34,840 INFO PBIT Timing: avg=0.22s, min=0.22s, max=0.22s, σ=0.00s
2026-02-02 15:39:34,840 INFO ==========================================================================================
2026-02-02 15:39:34,840 INFO Detailed statistics will be available in the PDF report
2026-02-02 15:39:34,840 INFO Exporting statistics to CSV: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_153934_statistics.csv
2026-02-02 15:39:34,842 INFO Statistics exported successfully to: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_153934_statistics.csv
2026-02-02 15:39:34,843 INFO Statistics exported successfully to JSON: c:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260202_153934_statistics.json
2026-02-02 15:39:34,843 INFO Set MAIN_POWER to False
2026-02-02 15:39:34,844 INFO [MOCK] Power OFF
2026-02-02 15:39:34,844 INFO [MOCK] 1553 Interface stopped
2026-02-02 15:39:39,844 INFO Check that MAIN_POWER is equal to 0
2026-02-02 15:39:39,845 INFO OK: read value = False
2026-02-02 15:39:39,845 INFO [MOCK] Serial terminal disconnected
2026-02-02 15:39:39,845 INFO Stop Time: 2026-02-02 15:38:47.997168
2026-02-02 15:39:39,846 INFO Test execution time: 0:00:51.848634