2026-02-03 10:00:43,125 INFO Start Time: 2026-02-03 10:00:43.125990
2026-02-03 10:00:43,126 INFO [MOCK] Serial terminal initialized
2026-02-03 10:00:43,126 INFO [MOCK] Serial terminal connected
2026-02-03 10:00:43,126 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-02-03 10:00:43,126 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-02-03 10:00:43,127 INFO [MOCK] Simulating target acquisition: will appear after 9 scan cycles
2026-02-03 10:00:43,137 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,194 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,258 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,320 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,380 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,443 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,494 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,557 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,628 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,682 INFO [MOCK] Target simulated at distance 1180
2026-02-03 10:00:43,682 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts
2026-02-03 10:00:43,682 INFO tgt_gen_alone(): 0
2026-02-03 10:00:43,682 INFO tgt_gen() - timeout: 10.0s
2026-02-03 10:00:43,697 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-02-03 10:00:43,697 INFO TgtMsg: 0 0
2026-02-03 10:00:43,698 INFO Tgt: 1 @ 1180
2026-02-03 10:00:43,698 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-03 10:00:43,698 INFO OK: read value = 1
2026-02-03 10:00:43,698 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-03 10:00:43,699 INFO OK: read value = 1180
2026-02-03 10:00:43,699 INFO [MOCK] Log stopped
2026-02-03 10:00:43,699 INFO Repetition 1 of 10
2026-02-03 10:00:43,699 DEBUG [MOCK] Serial statistics reset
2026-02-03 10:00:43,699 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-03 10:00:44,710 INFO Set MAIN_POWER to False
2026-02-03 10:00:44,710 INFO [MOCK] Power OFF
2026-02-03 10:00:44,711 INFO [MOCK] 1553 Interface stopped
2026-02-03 10:00:49,724 INFO Check that MAIN_POWER is equal to 0
2026-02-03 10:00:49,724 INFO OK: read value = False
2026-02-03 10:00:53,724 INFO The test operator is required to switch on the target.
2026-02-03 10:00:53,724 INFO Set MAIN_POWER to True
2026-02-03 10:00:53,724 INFO [MOCK] Power ON
2026-02-03 10:00:53,725 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-03 10:00:53,725 INFO run_count = 1
2026-02-03 10:00:53,725 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-03 10:00:53,725 INFO current_scenario = 'mixed'
2026-02-03 10:00:53,726 INFO _scenario_list = ['tx_tests_fail', 'transmitter_fail', 'processor_fail', 'agc_tests_fail', 'recycle_recovery_2', 'random_failures', 'random_failures', 'tx_tests_fail', 'mixed_b8_failures', 'normal']
2026-02-03 10:00:53,726 INFO [DEBUG] Entering MIXED MODE branch
2026-02-03 10:00:53,726 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='tx_tests_fail'
2026-02-03 10:00:53,726 INFO [DEBUG] About to call _log_scenario_info('tx_tests_fail', 1, 10)
2026-02-03 10:00:53,727 INFO
2026-02-03 10:00:53,727 INFO ####################################################################################################
2026-02-03 10:00:53,727 INFO ####################################################################################################
2026-02-03 10:00:53,727 INFO ### RUN 1/10: TRANSMITTER TEST FAILURES
2026-02-03 10:00:53,727 INFO ####################################################################################################
2026-02-03 10:00:53,727 INFO
2026-02-03 10:00:53,727 INFO SCENARIO: tx_tests_fail
2026-02-03 10:00:53,727 INFO DESCRIPTION: Individual TX tests fail (TX10, TX11, TX12)
2026-02-03 10:00:53,727 INFO
2026-02-03 10:00:53,728 INFO EXPECTED FAILURES:
2026-02-03 10:00:53,728 INFO ✗ B8: test_tx10_hv_ps_over_temperature_warning = FAIL
2026-02-03 10:00:53,728 INFO ✗ B8: test_tx11_twt_helix_over_current = FAIL
2026-02-03 10:00:53,728 INFO ✗ B8: test_tx12_cathode_to_helix_arc = FAIL
2026-02-03 10:00:53,728 INFO
2026-02-03 10:00:53,728 INFO EXPECTED PASSES:
2026-02-03 10:00:53,728 INFO ✓ B6 status fields (except transmitter)
2026-02-03 10:00:53,729 INFO ✓ Other B8 tests
2026-02-03 10:00:53,729 INFO
2026-02-03 10:00:53,729 INFO NOTES: Demonstrates granular test failure analysis - specific TX high-voltage issues
2026-02-03 10:00:53,729 INFO
2026-02-03 10:00:53,729 INFO ####################################################################################################
2026-02-03 10:00:53,730 INFO ####################################################################################################
2026-02-03 10:00:53,730 INFO
2026-02-03 10:00:53,730 INFO [DEBUG] _log_scenario_info() completed
2026-02-03 10:00:53,730 INFO [MOCK APPLY] ✗ Setting trasmitter_status = FAIL
2026-02-03 10:00:53,730 INFO [MOCK APPLY] ✗ B8 failures: TX10 (hv_ps_over_temp), TX11 (twt_helix_overcurrent), TX12 (cathode_arc)
2026-02-03 10:00:53,731 INFO [MOCK] Run 1: Target will be VISIBLE (pattern index 0)
2026-02-03 10:00:53,731 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1)
2026-02-03 10:00:58,741 INFO Check that MAIN_POWER is equal to 1
2026-02-03 10:00:58,741 INFO OK: read value = True
2026-02-03 10:00:58,851 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-03 10:00:58,852 DEBUG [MOCK] assignMessageFieldValue: A1_MsgRdrSettingsAndParameters.settings_RDROperationalSettings_rdr_symbology_intensity = 100
2026-02-03 10:00:59,057 INFO [MOCK] BIT report available after 5.3s
2026-02-03 10:00:59,091 INFO BIT report available after 0.2s
2026-02-03 10:00:59,092 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-03 10:00:59,092 INFO OK: read value = false
2026-02-03 10:00:59,093 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-03 10:00:59,093 WARNING CHECK ERROR: read value = true
2026-02-03 10:00:59,094 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:00:59,095 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-03 10:00:59,095 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-03 10:00:59,096 INFO OK: read value = false
2026-02-03 10:00:59,096 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-03 10:00:59,097 INFO OK: read value = false
2026-02-03 10:00:59,097 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-03 10:00:59,097 INFO OK: read value = false
2026-02-03 10:00:59,097 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-03 10:00:59,097 INFO OK: read value = false
2026-02-03 10:00:59,098 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-03 10:00:59,098 INFO OK: read value = false
2026-02-03 10:00:59,099 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-03 10:00:59,099 INFO OK: read value = false
2026-02-03 10:00:59,100 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-03 10:00:59,100 INFO OK: read value = false
2026-02-03 10:00:59,100 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-03 10:00:59,100 INFO OK: read value = false
2026-02-03 10:00:59,100 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-03 10:00:59,100 DEBUG [MOCK] Field status: true
2026-02-03 10:00:59,100 WARNING CHECK ERROR: read value = true
2026-02-03 10:00:59,100 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:00:59,102 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-03 10:00:59,102 WARNING CHECK ERROR: read value = true
2026-02-03 10:00:59,102 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:00:59,102 WARNING Radar fail status: REAL failure (caused by: status, status)
2026-02-03 10:00:59,103 INFO [Run 1] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known
2026-02-03 10:00:59,104 INFO Known failures (HW setup): 1
2026-02-03 10:00:59,104 WARNING Real failures: status, status
2026-02-03 10:00:59,105 INFO
Drill-down: Verifying all 173 B8 diagnostic fields...
2026-02-03 10:00:59,105 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-03 10:00:59,107 INFO OK: read value = false
2026-02-03 10:00:59,107 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-03 10:00:59,107 INFO OK: read value = false
2026-02-03 10:00:59,107 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-03 10:00:59,108 INFO OK: read value = false
2026-02-03 10:00:59,108 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-03 10:00:59,108 INFO OK: read value = false
2026-02-03 10:00:59,108 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-03 10:00:59,108 INFO OK: read value = false
2026-02-03 10:00:59,109 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-03 10:00:59,109 INFO OK: read value = false
2026-02-03 10:00:59,109 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-03 10:00:59,110 INFO OK: read value = false
2026-02-03 10:00:59,110 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-03 10:00:59,110 INFO OK: read value = false
2026-02-03 10:00:59,111 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-03 10:00:59,111 INFO OK: read value = false
2026-02-03 10:00:59,112 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-03 10:00:59,112 WARNING CHECK ERROR: read value = 0
2026-02-03 10:00:59,112 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-03 10:00:59,113 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-03 10:00:59,113 INFO OK: read value = false
2026-02-03 10:00:59,113 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-03 10:00:59,113 INFO OK: read value = false
2026-02-03 10:00:59,114 WARNING B8_Degradation: 1/12 failures
2026-02-03 10:00:59,114 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-03 10:00:59,114 INFO OK: read value = false
2026-02-03 10:00:59,114 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-03 10:00:59,114 INFO OK: read value = false
2026-02-03 10:00:59,115 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-03 10:00:59,115 INFO OK: read value = false
2026-02-03 10:00:59,115 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-03 10:00:59,116 INFO OK: read value = false
2026-02-03 10:00:59,116 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-03 10:00:59,116 INFO OK: read value = false
2026-02-03 10:00:59,117 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-03 10:00:59,118 INFO OK: read value = false
2026-02-03 10:00:59,118 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-03 10:00:59,118 INFO OK: read value = false
2026-02-03 10:00:59,119 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-03 10:00:59,119 INFO OK: read value = false
2026-02-03 10:00:59,119 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-03 10:00:59,119 INFO OK: read value = false
2026-02-03 10:00:59,120 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-03 10:00:59,120 INFO OK: read value = false
2026-02-03 10:00:59,120 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-03 10:00:59,120 INFO OK: read value = false
2026-02-03 10:00:59,120 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-03 10:00:59,121 INFO OK: read value = false
2026-02-03 10:00:59,121 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-03 10:00:59,121 INFO OK: read value = false
2026-02-03 10:00:59,121 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-03 10:00:59,122 INFO OK: read value = false
2026-02-03 10:00:59,122 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-03 10:00:59,123 INFO OK: read value = false
2026-02-03 10:00:59,123 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-03 10:00:59,123 INFO OK: read value = false
2026-02-03 10:00:59,123 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-03 10:00:59,124 INFO OK: read value = false
2026-02-03 10:00:59,124 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-03 10:00:59,124 INFO OK: read value = false
2026-02-03 10:00:59,124 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-03 10:00:59,125 INFO OK: read value = false
2026-02-03 10:00:59,125 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-03 10:00:59,125 INFO OK: read value = false
2026-02-03 10:00:59,126 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-03 10:00:59,126 INFO OK: read value = false
2026-02-03 10:00:59,126 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-03 10:00:59,126 INFO OK: read value = false
2026-02-03 10:00:59,126 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-03 10:00:59,127 INFO OK: read value = false
2026-02-03 10:00:59,127 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-03 10:00:59,127 INFO OK: read value = false
2026-02-03 10:00:59,127 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-03 10:00:59,128 INFO OK: read value = false
2026-02-03 10:00:59,128 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-03 10:00:59,128 INFO OK: read value = false
2026-02-03 10:00:59,129 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-03 10:00:59,129 INFO OK: read value = false
2026-02-03 10:00:59,129 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-03 10:00:59,130 INFO OK: read value = false
2026-02-03 10:00:59,130 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-03 10:00:59,130 INFO OK: read value = false
2026-02-03 10:00:59,130 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-03 10:00:59,130 INFO OK: read value = false
2026-02-03 10:00:59,131 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-03 10:00:59,131 INFO OK: read value = false
2026-02-03 10:00:59,131 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-03 10:00:59,131 INFO OK: read value = false
2026-02-03 10:00:59,131 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-03 10:00:59,132 INFO OK: read value = false
2026-02-03 10:00:59,132 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-03 10:00:59,132 INFO OK: read value = false
2026-02-03 10:00:59,132 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-03 10:00:59,133 INFO OK: read value = false
2026-02-03 10:00:59,133 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-03 10:00:59,133 INFO OK: read value = false
2026-02-03 10:00:59,133 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-03 10:00:59,133 INFO OK: read value = false
2026-02-03 10:00:59,134 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-03 10:00:59,134 INFO OK: read value = false
2026-02-03 10:00:59,134 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-03 10:00:59,135 INFO OK: read value = false
2026-02-03 10:00:59,135 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-03 10:00:59,135 INFO OK: read value = false
2026-02-03 10:00:59,135 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-03 10:00:59,136 INFO OK: read value = false
2026-02-03 10:00:59,136 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-03 10:00:59,136 INFO OK: read value = false
2026-02-03 10:00:59,136 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-03 10:00:59,137 INFO OK: read value = false
2026-02-03 10:00:59,137 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-03 10:00:59,137 INFO OK: read value = false
2026-02-03 10:00:59,138 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-03 10:00:59,138 INFO OK: read value = false
2026-02-03 10:00:59,138 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-03 10:00:59,139 INFO OK: read value = false
2026-02-03 10:00:59,139 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-03 10:00:59,139 INFO OK: read value = false
2026-02-03 10:00:59,140 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-03 10:00:59,140 INFO OK: read value = false
2026-02-03 10:00:59,140 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-03 10:00:59,140 INFO OK: read value = false
2026-02-03 10:00:59,141 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-03 10:00:59,141 INFO OK: read value = false
2026-02-03 10:00:59,141 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-03 10:00:59,141 INFO OK: read value = false
2026-02-03 10:00:59,142 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-03 10:00:59,142 INFO OK: read value = false
2026-02-03 10:00:59,142 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-03 10:00:59,142 INFO OK: read value = false
2026-02-03 10:00:59,144 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-03 10:00:59,144 INFO OK: read value = false
2026-02-03 10:00:59,144 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-03 10:00:59,144 INFO OK: read value = false
2026-02-03 10:00:59,144 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-03 10:00:59,144 INFO OK: read value = false
2026-02-03 10:00:59,145 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-03 10:00:59,145 INFO OK: read value = false
2026-02-03 10:00:59,145 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-03 10:00:59,145 INFO OK: read value = false
2026-02-03 10:00:59,146 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-03 10:00:59,146 INFO OK: read value = false
2026-02-03 10:00:59,146 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-03 10:00:59,146 INFO OK: read value = false
2026-02-03 10:00:59,146 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-03 10:00:59,147 INFO OK: read value = false
2026-02-03 10:00:59,147 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-03 10:00:59,147 INFO OK: read value = false
2026-02-03 10:00:59,147 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-03 10:00:59,147 INFO OK: read value = false
2026-02-03 10:00:59,148 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-03 10:00:59,148 INFO OK: read value = false
2026-02-03 10:00:59,148 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-03 10:00:59,148 INFO OK: read value = false
2026-02-03 10:00:59,149 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-03 10:00:59,149 INFO OK: read value = false
2026-02-03 10:00:59,149 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-03 10:00:59,149 INFO OK: read value = false
2026-02-03 10:00:59,149 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-03 10:00:59,150 INFO OK: read value = false
2026-02-03 10:00:59,150 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-03 10:00:59,150 INFO OK: read value = false
2026-02-03 10:00:59,150 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-03 10:00:59,150 INFO OK: read value = false
2026-02-03 10:00:59,151 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-03 10:00:59,151 INFO OK: read value = false
2026-02-03 10:00:59,151 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-03 10:00:59,151 INFO OK: read value = false
2026-02-03 10:00:59,151 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-03 10:00:59,151 INFO OK: read value = false
2026-02-03 10:00:59,152 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-03 10:00:59,152 INFO OK: read value = false
2026-02-03 10:00:59,152 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-03 10:00:59,152 INFO OK: read value = false
2026-02-03 10:00:59,152 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-03 10:00:59,152 INFO OK: read value = false
2026-02-03 10:00:59,153 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-03 10:00:59,153 INFO OK: read value = false
2026-02-03 10:00:59,153 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-03 10:00:59,153 INFO OK: read value = false
2026-02-03 10:00:59,153 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-03 10:00:59,154 INFO OK: read value = false
2026-02-03 10:00:59,154 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-03 10:00:59,154 INFO OK: read value = false
2026-02-03 10:00:59,154 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-03 10:00:59,154 INFO OK: read value = false
2026-02-03 10:00:59,154 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-03 10:00:59,155 INFO OK: read value = false
2026-02-03 10:00:59,155 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-03 10:00:59,155 INFO OK: read value = false
2026-02-03 10:00:59,155 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-03 10:00:59,156 INFO OK: read value = false
2026-02-03 10:00:59,156 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-03 10:00:59,156 INFO OK: read value = false
2026-02-03 10:00:59,156 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-03 10:00:59,156 INFO OK: read value = false
2026-02-03 10:00:59,157 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-03 10:00:59,157 INFO OK: read value = false
2026-02-03 10:00:59,157 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-03 10:00:59,157 INFO OK: read value = false
2026-02-03 10:00:59,158 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-03 10:00:59,158 INFO OK: read value = false
2026-02-03 10:00:59,158 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-03 10:00:59,158 INFO OK: read value = false
2026-02-03 10:00:59,158 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-03 10:00:59,159 INFO OK: read value = false
2026-02-03 10:00:59,159 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-03 10:00:59,159 INFO OK: read value = false
2026-02-03 10:00:59,159 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-03 10:00:59,160 INFO OK: read value = false
2026-02-03 10:00:59,160 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-03 10:00:59,160 INFO OK: read value = false
2026-02-03 10:00:59,160 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-03 10:00:59,160 INFO OK: read value = false
2026-02-03 10:00:59,161 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-03 10:00:59,161 INFO OK: read value = false
2026-02-03 10:00:59,161 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-03 10:00:59,161 INFO OK: read value = false
2026-02-03 10:00:59,161 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-03 10:00:59,162 INFO OK: read value = false
2026-02-03 10:00:59,162 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-03 10:00:59,162 INFO OK: read value = false
2026-02-03 10:00:59,162 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-03 10:00:59,162 INFO OK: read value = false
2026-02-03 10:00:59,163 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-03 10:00:59,163 INFO OK: read value = false
2026-02-03 10:00:59,163 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-03 10:00:59,163 INFO OK: read value = false
2026-02-03 10:00:59,163 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-03 10:00:59,163 INFO OK: read value = false
2026-02-03 10:00:59,163 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-03 10:00:59,164 INFO OK: read value = false
2026-02-03 10:00:59,164 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-03 10:00:59,164 INFO OK: read value = false
2026-02-03 10:00:59,164 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-03 10:00:59,164 INFO OK: read value = false
2026-02-03 10:00:59,165 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-03 10:00:59,165 INFO OK: read value = false
2026-02-03 10:00:59,165 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-03 10:00:59,165 INFO OK: read value = false
2026-02-03 10:00:59,165 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-03 10:00:59,165 INFO OK: read value = false
2026-02-03 10:00:59,166 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-03 10:00:59,166 INFO OK: read value = false
2026-02-03 10:00:59,166 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-03 10:00:59,166 INFO OK: read value = false
2026-02-03 10:00:59,166 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-03 10:00:59,166 INFO OK: read value = false
2026-02-03 10:00:59,167 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-03 10:00:59,167 INFO OK: read value = false
2026-02-03 10:00:59,167 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-03 10:00:59,167 INFO OK: read value = false
2026-02-03 10:00:59,167 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-03 10:00:59,167 INFO OK: read value = false
2026-02-03 10:00:59,167 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-03 10:00:59,168 INFO OK: read value = false
2026-02-03 10:00:59,168 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-03 10:00:59,168 INFO OK: read value = false
2026-02-03 10:00:59,168 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-03 10:00:59,168 INFO OK: read value = false
2026-02-03 10:00:59,169 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-03 10:00:59,169 INFO OK: read value = false
2026-02-03 10:00:59,169 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-03 10:00:59,169 INFO OK: read value = false
2026-02-03 10:00:59,169 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-03 10:00:59,169 INFO OK: read value = false
2026-02-03 10:00:59,170 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-03 10:00:59,170 INFO OK: read value = false
2026-02-03 10:00:59,170 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-03 10:00:59,170 INFO OK: read value = false
2026-02-03 10:00:59,170 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-03 10:00:59,170 INFO OK: read value = false
2026-02-03 10:00:59,170 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-03 10:00:59,171 INFO OK: read value = false
2026-02-03 10:00:59,171 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-03 10:00:59,171 INFO OK: read value = false
2026-02-03 10:00:59,171 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-03 10:00:59,171 INFO OK: read value = false
2026-02-03 10:00:59,171 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-03 10:00:59,172 INFO OK: read value = false
2026-02-03 10:00:59,172 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-03 10:00:59,172 INFO OK: read value = false
2026-02-03 10:00:59,172 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-03 10:00:59,172 INFO OK: read value = false
2026-02-03 10:00:59,172 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-03 10:00:59,173 INFO OK: read value = false
2026-02-03 10:00:59,173 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-03 10:00:59,173 INFO OK: read value = false
2026-02-03 10:00:59,173 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-03 10:00:59,173 INFO OK: read value = false
2026-02-03 10:00:59,173 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-03 10:00:59,174 INFO OK: read value = false
2026-02-03 10:00:59,174 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-03 10:00:59,174 INFO OK: read value = false
2026-02-03 10:00:59,175 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-03 10:00:59,175 WARNING CHECK ERROR: read value = true
2026-02-03 10:00:59,175 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:00:59,175 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-03 10:00:59,175 DEBUG [MOCK] Field current: true
2026-02-03 10:00:59,175 WARNING CHECK ERROR: read value = true
2026-02-03 10:00:59,176 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:00:59,176 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-03 10:00:59,176 WARNING CHECK ERROR: read value = true
2026-02-03 10:00:59,176 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:00:59,177 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-03 10:00:59,178 INFO OK: read value = false
2026-02-03 10:00:59,178 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-03 10:00:59,178 INFO OK: read value = false
2026-02-03 10:00:59,179 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-03 10:00:59,180 INFO OK: read value = false
2026-02-03 10:00:59,180 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-03 10:00:59,180 INFO OK: read value = false
2026-02-03 10:00:59,181 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-03 10:00:59,181 INFO OK: read value = false
2026-02-03 10:00:59,181 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-03 10:00:59,181 INFO OK: read value = false
2026-02-03 10:00:59,182 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-03 10:00:59,182 INFO OK: read value = false
2026-02-03 10:00:59,182 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-03 10:00:59,183 INFO OK: read value = false
2026-02-03 10:00:59,183 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-03 10:00:59,183 INFO OK: read value = false
2026-02-03 10:00:59,183 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-03 10:00:59,183 INFO OK: read value = false
2026-02-03 10:00:59,184 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-03 10:00:59,184 INFO OK: read value = false
2026-02-03 10:00:59,184 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-03 10:00:59,184 INFO OK: read value = false
2026-02-03 10:00:59,184 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-03 10:00:59,184 INFO OK: read value = false
2026-02-03 10:00:59,185 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-03 10:00:59,185 INFO OK: read value = false
2026-02-03 10:00:59,185 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-03 10:00:59,186 INFO OK: read value = false
2026-02-03 10:00:59,186 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-03 10:00:59,186 INFO OK: read value = false
2026-02-03 10:00:59,186 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-03 10:00:59,187 INFO OK: read value = false
2026-02-03 10:00:59,187 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-03 10:00:59,187 INFO OK: read value = false
2026-02-03 10:00:59,187 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-03 10:00:59,188 INFO OK: read value = false
2026-02-03 10:00:59,188 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-03 10:00:59,188 INFO OK: read value = false
2026-02-03 10:00:59,188 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-03 10:00:59,189 INFO OK: read value = false
2026-02-03 10:00:59,189 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-03 10:00:59,189 INFO OK: read value = false
2026-02-03 10:00:59,189 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-03 10:00:59,189 INFO OK: read value = false
2026-02-03 10:00:59,190 WARNING B8_Test_Transmitter: 3/26 failures
2026-02-03 10:00:59,190 INFO [Run 1] B8 Diagnostics: 173 checked, 169 pass, 4 fail
2026-02-03 10:00:59,190 WARNING B8_Degradation: 1 failures - fail
2026-02-03 10:00:59,190 WARNING B8_Test_Transmitter: 3 failures - warning, current, arc
2026-02-03 10:00:59,191 INFO 0.0s remaining ...
2026-02-03 10:00:59,191 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-03 10:00:59,191 INFO Target Detection Test
2026-02-03 10:00:59,191 INFO [Run 1] Starting target detection test (timeout: 10.0s)
2026-02-03 10:00:59,191 INFO Setting radar to operational mode before target test (best-effort)
2026-02-03 10:00:59,192 INFO Executing auxiliary serial sequence to prepare radar
2026-02-03 10:00:59,193 INFO Opening serial port: COM5 @ 115200bps
2026-02-03 10:00:59,193 ERROR Error in send_serial_sequence: could not open port 'COM5': FileNotFoundError(2, 'Impossibile trovare il file specificato.', None, 2)
Traceback (most recent call last):
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\serial_aux.py", line 99, in send_serial_sequence
parity=PARITY, stopbits=STOPBITS, timeout=0.2)
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\PlatformSimulator\bin\python37.zip\serial\serialwin32.py", line 31, in __init__
super(Serial, self).__init__(*args, **kwargs)
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\PlatformSimulator\bin\python37.zip\serial\serialutil.py", line 240, in __init__
self.open()
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\PlatformSimulator\bin\python37.zip\serial\serialwin32.py", line 62, in open
raise SerialException("could not open port {!r}: {!r}".format(self.portstr, ctypes.WinError()))
serial.serialutil.SerialException: could not open port 'COM5': FileNotFoundError(2, 'Impossibile trovare il file specificato.', None, 2)
2026-02-03 10:00:59,204 WARNING Aux serial sequence failed: could not open port 'COM5': FileNotFoundError(2, 'Impossibile trovare il file specificato.', None, 2)
2026-02-03 10:00:59,204 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_silence to 1
2026-02-03 10:00:59,204 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_silence = 1
2026-02-03 10:00:59,410 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_silence -> 1 : True
2026-02-03 10:00:59,410 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby to 1
2026-02-03 10:00:59,410 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_stby = 1
2026-02-03 10:00:59,615 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby -> 1 : True
2026-02-03 10:01:01,616 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 127
2026-02-03 10:01:01,618 DEBUG [MOCK] assignMessageFieldValue: A1_MsgRdrSettingsAndParameters.settings_RDROperationalSettings_rdr_symbology_intensity = 127
2026-02-03 10:01:01,832 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity -> 127 : True
2026-02-03 10:01:01,833 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_target_history to 3
2026-02-03 10:01:01,833 DEBUG [MOCK] assignMessageFieldValue: A1_MsgRdrSettingsAndParameters.settings_RDROperationalSettings_target_history = 3
2026-02-03 10:01:02,038 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_target_history -> 3 : True
2026-02-03 10:01:02,038 INFO Set A2_MsgRdrOperationCommand param1_RdrFunAndParam1_range_scale_selection to 1
2026-02-03 10:01:02,038 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.param1_RdrFunAndParam1_range_scale_selection = 1
2026-02-03 10:01:02,241 INFO Set A2_MsgRdrOperationCommand param1_RdrFunAndParam1_range_scale_selection -> 1 : True
2026-02-03 10:01:02,243 INFO Set A2_MsgRdrModeCommand rdr_mode_command_master_mode to RWS
2026-02-03 10:01:02,243 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrModeCommand.rdr_mode_command_master_mode = RWS
2026-02-03 10:01:02,443 INFO Set A2_MsgRdrModeCommand rdr_mode_command_master_mode -> RWS : True
2026-02-03 10:01:02,443 INFO Set A2_MsgRdrModeCommand param1_gm_submode to 0
2026-02-03 10:01:02,443 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrModeCommand.param1_gm_submode = 0
2026-02-03 10:01:02,649 INFO Set A2_MsgRdrModeCommand param1_gm_submode -> 0 : True
2026-02-03 10:01:02,649 INFO Set A4_MsgValidityAndSlew validity_and_slew_raw to 0
2026-02-03 10:01:02,650 DEBUG [MOCK] assignMessageFieldValue: A4_MsgValidityAndSlew.validity_and_slew_raw = 0
2026-02-03 10:01:02,853 INFO Set A4_MsgValidityAndSlew validity_and_slew_raw -> 0 : True
2026-02-03 10:01:02,853 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_stby_tellback is equal to STBY_ON
2026-02-03 10:01:02,854 INFO OK: read value = STBY_ON
2026-02-03 10:01:02,854 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_rf_radiation_status is equal to RADIATION_OFF
2026-02-03 10:01:02,854 INFO OK: read value = RADIATION_OFF
2026-02-03 10:01:02,854 INFO Removing STBY before target acquisition to enable radar TX
2026-02-03 10:01:02,855 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby to 0
2026-02-03 10:01:02,855 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_stby = 0
2026-02-03 10:01:05,085 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_stby_tellback is equal to STBY_OFF
2026-02-03 10:01:05,085 INFO OK: read value = STBY_OFF
2026-02-03 10:01:05,086 INFO tgt_gen() - timeout: 10.0s
2026-02-03 10:01:05,101 DEBUG [MOCK] Field num: 1
2026-02-03 10:01:05,101 INFO TgtMsg: 1 1
2026-02-03 10:01:05,102 INFO Tgt: 1 @ 1180
2026-02-03 10:01:05,103 INFO Check that B9 b9_t_num is between 1 and 2
2026-02-03 10:01:05,103 INFO OK: read value = 1
2026-02-03 10:01:05,103 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-02-03 10:01:05,104 INFO OK: read value = 1180
2026-02-03 10:01:05,104 INFO Re-enabling STBY after target test
2026-02-03 10:01:05,105 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby to 1
2026-02-03 10:01:05,105 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_stby = 1
2026-02-03 10:01:07,317 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_stby_tellback is equal to STBY_ON
2026-02-03 10:01:07,317 INFO OK: read value = STBY_ON
2026-02-03 10:01:07,318 INFO Target detected successfully in 0.02s
2026-02-03 10:01:07,318 INFO [Run 1] Target DETECTED in 0.02s
2026-02-03 10:01:07,318 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 10
Total Step 208: Success 201 (96.63%), Failed 7 (3.37%),
2026-02-03 10:01:07,318 INFO Repetition 2 of 10
2026-02-03 10:01:07,318 DEBUG [MOCK] Serial statistics reset
2026-02-03 10:01:07,318 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-02-03 10:01:08,318 INFO Set MAIN_POWER to False
2026-02-03 10:01:08,318 INFO [MOCK] Power OFF
2026-02-03 10:01:08,319 INFO [MOCK] 1553 Interface stopped
2026-02-03 10:01:13,333 INFO Check that MAIN_POWER is equal to 0
2026-02-03 10:01:13,334 INFO OK: read value = False
2026-02-03 10:01:17,336 INFO The test operator is required to switch on the target.
2026-02-03 10:01:17,336 INFO Set MAIN_POWER to True
2026-02-03 10:01:17,336 INFO [MOCK] Power ON
2026-02-03 10:01:17,338 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-02-03 10:01:17,338 INFO run_count = 2
2026-02-03 10:01:17,338 INFO SIMULATION_SCENARIO = 'mixed'
2026-02-03 10:01:17,338 INFO current_scenario = 'mixed'
2026-02-03 10:01:17,338 INFO _scenario_list = ['tx_tests_fail', 'transmitter_fail', 'processor_fail', 'agc_tests_fail', 'recycle_recovery_2', 'random_failures', 'random_failures', 'tx_tests_fail', 'mixed_b8_failures', 'normal']
2026-02-03 10:01:17,339 INFO [DEBUG] Entering MIXED MODE branch
2026-02-03 10:01:17,340 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='transmitter_fail'
2026-02-03 10:01:17,340 INFO [DEBUG] About to call _log_scenario_info('transmitter_fail', 2, 10)
2026-02-03 10:01:17,340 INFO
2026-02-03 10:01:17,340 INFO ####################################################################################################
2026-02-03 10:01:17,340 INFO ####################################################################################################
2026-02-03 10:01:17,341 INFO ### RUN 2/10: TRANSMITTER FAILURE
2026-02-03 10:01:17,341 INFO ####################################################################################################
2026-02-03 10:01:17,341 INFO
2026-02-03 10:01:17,341 INFO SCENARIO: transmitter_fail
2026-02-03 10:01:17,341 INFO DESCRIPTION: Transmitter subsystem failure detected
2026-02-03 10:01:17,341 INFO
2026-02-03 10:01:17,342 INFO EXPECTED FAILURES:
2026-02-03 10:01:17,342 INFO ✗ B6: trasmitter_status = FAIL
2026-02-03 10:01:17,342 INFO ✗ B6: radar_fail_status = RDR_FAIL
2026-02-03 10:01:17,342 INFO
2026-02-03 10:01:17,342 INFO EXPECTED PASSES:
2026-02-03 10:01:17,342 INFO ✓ Other B6 fields
2026-02-03 10:01:17,343 INFO ✓ B8 diagnostic fields
2026-02-03 10:01:17,343 INFO ✓ Target generation
2026-02-03 10:01:17,343 INFO
2026-02-03 10:01:17,343 INFO NOTES: Test should detect transmitter failure and trigger B8 drill-down
2026-02-03 10:01:17,343 INFO
2026-02-03 10:01:17,343 INFO ####################################################################################################
2026-02-03 10:01:17,343 INFO ####################################################################################################
2026-02-03 10:01:17,343 INFO
2026-02-03 10:01:17,344 INFO [DEBUG] _log_scenario_info() completed
2026-02-03 10:01:17,344 INFO [MOCK APPLY] ✗ Setting trasmitter_status = FAIL
2026-02-03 10:01:17,344 INFO [MOCK APPLY] ✗ Setting radar_fail_status = RDR_FAIL
2026-02-03 10:01:17,344 INFO [MOCK] Run 2: Target will be NOT VISIBLE (pattern index 1)
2026-02-03 10:01:17,344 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-02-03 10:01:22,351 INFO Check that MAIN_POWER is equal to 1
2026-02-03 10:01:22,351 INFO OK: read value = True
2026-02-03 10:01:22,459 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 100
2026-02-03 10:01:22,459 DEBUG [MOCK] assignMessageFieldValue: A1_MsgRdrSettingsAndParameters.settings_RDROperationalSettings_rdr_symbology_intensity = 100
2026-02-03 10:01:22,669 INFO [MOCK] BIT report available after 5.3s
2026-02-03 10:01:22,694 INFO BIT report available after 0.2s
2026-02-03 10:01:22,694 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-02-03 10:01:22,695 INFO OK: read value = false
2026-02-03 10:01:22,695 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-02-03 10:01:22,696 WARNING CHECK ERROR: read value = true
2026-02-03 10:01:22,696 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:01:22,696 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-02-03 10:01:22,696 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-02-03 10:01:22,697 INFO OK: read value = false
2026-02-03 10:01:22,697 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-02-03 10:01:22,697 INFO OK: read value = false
2026-02-03 10:01:22,697 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-02-03 10:01:22,697 INFO OK: read value = false
2026-02-03 10:01:22,698 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-02-03 10:01:22,698 INFO OK: read value = false
2026-02-03 10:01:22,698 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-02-03 10:01:22,698 INFO OK: read value = false
2026-02-03 10:01:22,699 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-02-03 10:01:22,699 INFO OK: read value = false
2026-02-03 10:01:22,699 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-02-03 10:01:22,699 INFO OK: read value = false
2026-02-03 10:01:22,699 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-02-03 10:01:22,699 INFO OK: read value = false
2026-02-03 10:01:22,700 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-02-03 10:01:22,700 WARNING CHECK ERROR: read value = true
2026-02-03 10:01:22,700 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:01:22,700 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-02-03 10:01:22,700 WARNING CHECK ERROR: read value = true
2026-02-03 10:01:22,701 ERROR INTERFACE ERROR: Expected false, got true
2026-02-03 10:01:22,701 WARNING Radar fail status: REAL failure (caused by: status, status)
2026-02-03 10:01:22,701 INFO [Run 2] B6 LRU Status: 12 total, 9 pass, 2 fail, 1 known
2026-02-03 10:01:22,701 INFO Known failures (HW setup): 1
2026-02-03 10:01:22,701 WARNING Real failures: status, status
2026-02-03 10:01:22,701 INFO
Drill-down: Verifying all 173 B8 diagnostic fields...
2026-02-03 10:01:22,702 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_bcn_fail is equal to false
2026-02-03 10:01:22,702 INFO OK: read value = false
2026-02-03 10:01:22,702 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_gm_rbm_sea1_ta_wa_fail is equal to false
2026-02-03 10:01:22,702 INFO OK: read value = false
2026-02-03 10:01:22,702 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group1_fail is equal to false
2026-02-03 10:01:22,702 INFO OK: read value = false
2026-02-03 10:01:22,702 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group2_fail is equal to false
2026-02-03 10:01:22,703 INFO OK: read value = false
2026-02-03 10:01:22,703 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group3_fail is equal to false
2026-02-03 10:01:22,703 INFO OK: read value = false
2026-02-03 10:01:22,703 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group4_fail is equal to false
2026-02-03 10:01:22,703 INFO OK: read value = false
2026-02-03 10:01:22,703 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_group5_fail is equal to false
2026-02-03 10:01:22,703 INFO OK: read value = false
2026-02-03 10:01:22,703 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_hr_modes_and_gm_dbs_fail is equal to false
2026-02-03 10:01:22,704 INFO OK: read value = false
2026-02-03 10:01:22,704 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_no_rdr_symbology is equal to false
2026-02-03 10:01:22,704 INFO OK: read value = false
2026-02-03 10:01:22,704 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_not_identified_rdr_fail is equal to false
2026-02-03 10:01:22,704 WARNING CHECK ERROR: read value = 0
2026-02-03 10:01:22,704 ERROR INTERFACE ERROR: Expected false, got 0
2026-02-03 10:01:22,704 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_selected_channel_fail is equal to false
2026-02-03 10:01:22,704 INFO OK: read value = false
2026-02-03 10:01:22,704 INFO Check that B8_MsgBitReport degradation_conditions_w1_DegradationConditionsW1_total_rdr_fail is equal to false
2026-02-03 10:01:22,705 INFO OK: read value = false
2026-02-03 10:01:22,705 WARNING B8_Degradation: 1/12 failures
2026-02-03 10:01:22,705 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru1_gimbal is equal to false
2026-02-03 10:01:22,705 INFO OK: read value = false
2026-02-03 10:01:22,705 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru2_waveguide is equal to false
2026-02-03 10:01:22,705 INFO OK: read value = false
2026-02-03 10:01:22,705 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru3_waveguide is equal to false
2026-02-03 10:01:22,705 INFO OK: read value = false
2026-02-03 10:01:22,706 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru4_delta_guard_lna_switch is equal to false
2026-02-03 10:01:22,706 INFO OK: read value = false
2026-02-03 10:01:22,706 INFO Check that B8_MsgBitReport failure_location_pedestal_FailureLocationPedestal_sru5_waveguide_switch is equal to false
2026-02-03 10:01:22,706 INFO OK: read value = false
2026-02-03 10:01:22,706 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru10_main_computer is equal to false
2026-02-03 10:01:22,706 INFO OK: read value = false
2026-02-03 10:01:22,706 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru11_graphic_computer is equal to false
2026-02-03 10:01:22,706 INFO OK: read value = false
2026-02-03 10:01:22,707 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru12_power_supply is equal to false
2026-02-03 10:01:22,707 INFO OK: read value = false
2026-02-03 10:01:22,707 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru13_det_exp is equal to false
2026-02-03 10:01:22,707 INFO OK: read value = false
2026-02-03 10:01:22,707 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru14_rx_module is equal to false
2026-02-03 10:01:22,707 INFO OK: read value = false
2026-02-03 10:01:22,708 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru1_motherboard_chassis is equal to false
2026-02-03 10:01:22,708 INFO OK: read value = false
2026-02-03 10:01:22,708 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru2_mti_fft is equal to false
2026-02-03 10:01:22,708 INFO OK: read value = false
2026-02-03 10:01:22,708 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru3_dsp0 is equal to false
2026-02-03 10:01:22,708 INFO OK: read value = false
2026-02-03 10:01:22,708 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru4_dsp1 is equal to false
2026-02-03 10:01:22,708 INFO OK: read value = false
2026-02-03 10:01:22,709 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru5_cfar_px_ctrl is equal to false
2026-02-03 10:01:22,709 INFO OK: read value = false
2026-02-03 10:01:22,709 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru6_timer is equal to false
2026-02-03 10:01:22,709 INFO OK: read value = false
2026-02-03 10:01:22,709 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru7_post_processor is equal to false
2026-02-03 10:01:22,709 INFO OK: read value = false
2026-02-03 10:01:22,709 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru8_agc is equal to false
2026-02-03 10:01:22,709 INFO OK: read value = false
2026-02-03 10:01:22,710 INFO Check that B8_MsgBitReport failure_location_processor_FailureLocationProcessor_sru9_esa_if is equal to false
2026-02-03 10:01:22,710 INFO OK: read value = false
2026-02-03 10:01:22,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru1_chassis is equal to false
2026-02-03 10:01:22,710 INFO OK: read value = false
2026-02-03 10:01:22,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru2_uhf_assy is equal to false
2026-02-03 10:01:22,710 INFO OK: read value = false
2026-02-03 10:01:22,710 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru3_synthesizer is equal to false
2026-02-03 10:01:22,710 INFO OK: read value = false
2026-02-03 10:01:22,711 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru4_delta_guard_down_converter is equal to false
2026-02-03 10:01:22,711 INFO OK: read value = false
2026-02-03 10:01:22,711 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru5_sum_down_converter is equal to false
2026-02-03 10:01:22,711 INFO OK: read value = false
2026-02-03 10:01:22,711 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru6_lo_distributor is equal to false
2026-02-03 10:01:22,711 INFO OK: read value = false
2026-02-03 10:01:22,711 INFO Check that B8_MsgBitReport failure_location_receiver_FailureLocationReceiver_sru7_up_converter is equal to false
2026-02-03 10:01:22,711 INFO OK: read value = false
2026-02-03 10:01:22,712 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru1_chassis is equal to false
2026-02-03 10:01:22,712 INFO OK: read value = false
2026-02-03 10:01:22,712 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru2_delta_guard_lna is equal to false
2026-02-03 10:01:22,715 INFO OK: read value = false
2026-02-03 10:01:22,716 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru3_sum_act_prot_lna is equal to false
2026-02-03 10:01:22,716 INFO OK: read value = false
2026-02-03 10:01:22,716 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru4_4port_circulator is equal to false
2026-02-03 10:01:22,716 INFO OK: read value = false
2026-02-03 10:01:22,717 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_delta_guard is equal to false
2026-02-03 10:01:22,717 INFO OK: read value = false
2026-02-03 10:01:22,717 INFO Check that B8_MsgBitReport failure_location_rx_frontend_FailureLocationRxFrontEnd_sru5_stc_sum is equal to false
2026-02-03 10:01:22,717 INFO OK: read value = false
2026-02-03 10:01:22,717 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru1_chassis is equal to false
2026-02-03 10:01:22,717 INFO OK: read value = false
2026-02-03 10:01:22,717 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru2_power_supply is equal to false
2026-02-03 10:01:22,718 INFO OK: read value = false
2026-02-03 10:01:22,718 INFO Check that B8_MsgBitReport failure_location_servoloop_FailureLocationServoloop_sru3_digital_controller is equal to false
2026-02-03 10:01:22,718 INFO OK: read value = false
2026-02-03 10:01:22,719 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru1_chassis is equal to false
2026-02-03 10:01:22,719 INFO OK: read value = false
2026-02-03 10:01:22,719 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru2_rex_f_tx is equal to false
2026-02-03 10:01:22,719 INFO OK: read value = false
2026-02-03 10:01:22,719 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru3_power_supply is equal to false
2026-02-03 10:01:22,719 INFO OK: read value = false
2026-02-03 10:01:22,719 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru4_valve_el_twt_tx is equal to false
2026-02-03 10:01:22,719 INFO OK: read value = false
2026-02-03 10:01:22,720 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru5_rf_driver is equal to false
2026-02-03 10:01:22,720 INFO OK: read value = false
2026-02-03 10:01:22,720 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru6_controller_tx is equal to false
2026-02-03 10:01:22,720 INFO OK: read value = false
2026-02-03 10:01:22,720 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru7_hv_power_supply is equal to false
2026-02-03 10:01:22,720 INFO OK: read value = false
2026-02-03 10:01:22,720 INFO Check that B8_MsgBitReport failure_location_transmitter_FailureLocationTransmitter_sru8_eht_power_supply is equal to false
2026-02-03 10:01:22,721 INFO OK: read value = false
2026-02-03 10:01:22,721 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc10_pulse_compressor_interface is equal to false
2026-02-03 10:01:22,721 INFO OK: read value = false
2026-02-03 10:01:22,721 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc11_dp_interface is equal to false
2026-02-03 10:01:22,721 INFO OK: read value = false
2026-02-03 10:01:22,721 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc13_taxi_running is equal to false
2026-02-03 10:01:22,722 INFO OK: read value = false
2026-02-03 10:01:22,722 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc14_external_xyp_ram is equal to false
2026-02-03 10:01:22,723 INFO OK: read value = false
2026-02-03 10:01:22,723 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc15_servoloop_interface is equal to false
2026-02-03 10:01:22,723 INFO OK: read value = false
2026-02-03 10:01:22,723 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc1_internal_xyp_ram is equal to false
2026-02-03 10:01:22,723 INFO OK: read value = false
2026-02-03 10:01:22,724 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc2_external_xyp_ram is equal to false
2026-02-03 10:01:22,724 INFO OK: read value = false
2026-02-03 10:01:22,724 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc5_dual_port_ram is equal to false
2026-02-03 10:01:22,724 INFO OK: read value = false
2026-02-03 10:01:22,725 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc6_agc_machine is equal to false
2026-02-03 10:01:22,725 INFO OK: read value = false
2026-02-03 10:01:22,725 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc7_sat_machine is equal to false
2026-02-03 10:01:22,725 INFO OK: read value = false
2026-02-03 10:01:22,725 INFO Check that B8_MsgBitReport agc_test_results_AGCTestResults_test_agc9_c_ram_xy_checksum is equal to false
2026-02-03 10:01:22,726 INFO OK: read value = false
2026-02-03 10:01:22,726 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp10_video_memory is equal to false
2026-02-03 10:01:22,726 INFO OK: read value = false
2026-02-03 10:01:22,726 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp11_video_unit is equal to false
2026-02-03 10:01:22,726 INFO OK: read value = false
2026-02-03 10:01:22,727 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp12_transputer_unit is equal to false
2026-02-03 10:01:22,727 INFO OK: read value = false
2026-02-03 10:01:22,727 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp13_scan_converter_polar_memory is equal to false
2026-02-03 10:01:22,728 INFO OK: read value = false
2026-02-03 10:01:22,728 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp14_scan_converter_format_converter is equal to false
2026-02-03 10:01:22,729 INFO OK: read value = false
2026-02-03 10:01:22,729 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp1_486_cpu_tests is equal to false
2026-02-03 10:01:22,730 INFO OK: read value = false
2026-02-03 10:01:22,730 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp2_486_interfaces_with_r3000_gc is equal to false
2026-02-03 10:01:22,730 INFO OK: read value = false
2026-02-03 10:01:22,730 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp3_486_interface_with_slc is equal to false
2026-02-03 10:01:22,730 INFO OK: read value = false
2026-02-03 10:01:22,731 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp4_slc_communications is equal to false
2026-02-03 10:01:22,731 INFO OK: read value = false
2026-02-03 10:01:22,731 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp5_r3000_cpu_tests is equal to false
2026-02-03 10:01:22,731 INFO OK: read value = false
2026-02-03 10:01:22,731 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp6_r3000_interfaces is equal to false
2026-02-03 10:01:22,731 INFO OK: read value = false
2026-02-03 10:01:22,732 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp7_1553_and_discretes is equal to false
2026-02-03 10:01:22,732 INFO OK: read value = false
2026-02-03 10:01:22,732 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp8_graphic_cpu is equal to false
2026-02-03 10:01:22,732 INFO OK: read value = false
2026-02-03 10:01:22,732 INFO Check that B8_MsgBitReport data_processor_test_results_DataProcessorTestResults_test_dp9_graphic_processors is equal to false
2026-02-03 10:01:22,732 INFO OK: read value = false
2026-02-03 10:01:22,733 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_array_status is equal to false
2026-02-03 10:01:22,733 INFO OK: read value = false
2026-02-03 10:01:22,733 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_delta_channel_fail is equal to false
2026-02-03 10:01:22,733 INFO OK: read value = false
2026-02-03 10:01:22,733 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_injection_fail is equal to false
2026-02-03 10:01:22,733 INFO OK: read value = false
2026-02-03 10:01:22,734 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_cal_noise_fail is equal to false
2026-02-03 10:01:22,734 INFO OK: read value = false
2026-02-03 10:01:22,734 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_pedestal_status is equal to false
2026-02-03 10:01:22,734 INFO OK: read value = false
2026-02-03 10:01:22,735 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_processor_status is equal to false
2026-02-03 10:01:22,735 INFO OK: read value = false
2026-02-03 10:01:22,735 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_receiver_status is equal to false
2026-02-03 10:01:22,735 INFO OK: read value = false
2026-02-03 10:01:22,735 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_rx_frontend_status is equal to false
2026-02-03 10:01:22,735 INFO OK: read value = false
2026-02-03 10:01:22,736 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_servoloop_status is equal to false
2026-02-03 10:01:22,736 INFO OK: read value = false
2026-02-03 10:01:22,736 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is1_upconverter_chain_levels is equal to false
2026-02-03 10:01:22,736 INFO OK: read value = false
2026-02-03 10:01:22,736 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is2_downconverter_chain_levels is equal to false
2026-02-03 10:01:22,736 INFO OK: read value = false
2026-02-03 10:01:22,736 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is3_antenna_status_inconsistent is equal to false
2026-02-03 10:01:22,736 INFO OK: read value = false
2026-02-03 10:01:22,736 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is4_tx_status_inconsistent is equal to false
2026-02-03 10:01:22,738 INFO OK: read value = false
2026-02-03 10:01:22,739 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_test_is5_tx_power_level is equal to false
2026-02-03 10:01:22,740 INFO OK: read value = false
2026-02-03 10:01:22,740 INFO Check that B8_MsgBitReport integrated_system_test_results_IntegratedSystemTestResults_transmitter_status is equal to false
2026-02-03 10:01:22,740 INFO OK: read value = false
2026-02-03 10:01:22,741 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp1_master_dsp is equal to false
2026-02-03 10:01:22,741 INFO OK: read value = false
2026-02-03 10:01:22,741 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp2_interface_card is equal to false
2026-02-03 10:01:22,741 INFO OK: read value = false
2026-02-03 10:01:22,741 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp3_cpu_cards is equal to false
2026-02-03 10:01:22,742 INFO OK: read value = false
2026-02-03 10:01:22,742 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp4_dma_bus is equal to false
2026-02-03 10:01:22,742 INFO OK: read value = false
2026-02-03 10:01:22,743 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp5_sp_interface is equal to false
2026-02-03 10:01:22,743 INFO OK: read value = false
2026-02-03 10:01:22,744 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp6_dp_interface is equal to false
2026-02-03 10:01:22,744 INFO OK: read value = false
2026-02-03 10:01:22,744 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp7_scan_converter_interface is equal to false
2026-02-03 10:01:22,744 INFO OK: read value = false
2026-02-03 10:01:22,744 INFO Check that B8_MsgBitReport post_processor_test_results_PostProcessorTestResults_test_pp8_agc_interface is equal to false
2026-02-03 10:01:22,744 INFO OK: read value = false
2026-02-03 10:01:22,744 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps1_power_supply is equal to false
2026-02-03 10:01:22,744 INFO OK: read value = false
2026-02-03 10:01:22,745 INFO Check that B8_MsgBitReport power_supply_test_results_PowerSupplyTestResults_test_ps2_over_temperature is equal to false
2026-02-03 10:01:22,745 INFO OK: read value = false
2026-02-03 10:01:22,745 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe1_lna is equal to false
2026-02-03 10:01:22,745 INFO OK: read value = false
2026-02-03 10:01:22,745 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_fe2_agc_attenuators is equal to false
2026-02-03 10:01:22,745 INFO OK: read value = false
2026-02-03 10:01:22,745 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx1_synthesizer_commands is equal to false
2026-02-03 10:01:22,746 INFO OK: read value = false
2026-02-03 10:01:22,746 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx2_synthesizer_internal_tests is equal to false
2026-02-03 10:01:22,746 INFO OK: read value = false
2026-02-03 10:01:22,746 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx3_uhf_oscillator_level is equal to false
2026-02-03 10:01:22,746 INFO OK: read value = false
2026-02-03 10:01:22,746 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx4_downconverter_lo_level is equal to false
2026-02-03 10:01:22,746 INFO OK: read value = false
2026-02-03 10:01:22,746 INFO Check that B8_MsgBitReport receiver_and_rx_frontend_test_results_ReceiverAndRxTestResults_test_rx5_upconverter_lo_level is equal to false
2026-02-03 10:01:22,747 INFO OK: read value = false
2026-02-03 10:01:22,747 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm16_calibration_sum_channel_fail is equal to false
2026-02-03 10:01:22,747 INFO OK: read value = false
2026-02-03 10:01:22,747 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm1_master_clock_level is equal to false
2026-02-03 10:01:22,747 INFO OK: read value = false
2026-02-03 10:01:22,748 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm2_expander_level is equal to false
2026-02-03 10:01:22,748 INFO OK: read value = false
2026-02-03 10:01:22,749 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm3_sum_channel_down_converter is equal to false
2026-02-03 10:01:22,749 INFO OK: read value = false
2026-02-03 10:01:22,750 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm4_dg_channel_down_converter is equal to false
2026-02-03 10:01:22,750 INFO OK: read value = false
2026-02-03 10:01:22,750 INFO Check that B8_MsgBitReport rx_module_test_results_RxModuleTestResults_test_rm5_noise_attenuators is equal to false
2026-02-03 10:01:22,750 INFO OK: read value = false
2026-02-03 10:01:22,751 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl10_agc_control is equal to false
2026-02-03 10:01:22,751 INFO OK: read value = false
2026-02-03 10:01:22,751 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl11_ad is equal to false
2026-02-03 10:01:22,751 INFO OK: read value = false
2026-02-03 10:01:22,751 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl12_das is equal to false
2026-02-03 10:01:22,751 INFO OK: read value = false
2026-02-03 10:01:22,752 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl13_serial_communications is equal to false
2026-02-03 10:01:22,752 INFO OK: read value = false
2026-02-03 10:01:22,752 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl14_taxi_interface is equal to false
2026-02-03 10:01:22,752 INFO OK: read value = false
2026-02-03 10:01:22,752 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl15_pedestal_centre_scan_location is equal to false
2026-02-03 10:01:22,752 INFO OK: read value = false
2026-02-03 10:01:22,753 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl1_low_voltage_power_supply is equal to false
2026-02-03 10:01:22,753 INFO OK: read value = false
2026-02-03 10:01:22,753 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl2_high_voltage_power_supply is equal to false
2026-02-03 10:01:22,753 INFO OK: read value = false
2026-02-03 10:01:22,753 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl3_motor_drivers is equal to false
2026-02-03 10:01:22,753 INFO OK: read value = false
2026-02-03 10:01:22,754 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl4_resolvers_power_supply is equal to false
2026-02-03 10:01:22,754 INFO OK: read value = false
2026-02-03 10:01:22,754 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl5_waveguide_switch is equal to false
2026-02-03 10:01:22,755 INFO OK: read value = false
2026-02-03 10:01:22,755 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl6_over_temperature is equal to false
2026-02-03 10:01:22,755 INFO OK: read value = false
2026-02-03 10:01:22,755 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl7_resolver_to_digital_conv is equal to false
2026-02-03 10:01:22,755 INFO OK: read value = false
2026-02-03 10:01:22,756 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl8_position_loop_error is equal to false
2026-02-03 10:01:22,756 INFO OK: read value = false
2026-02-03 10:01:22,756 INFO Check that B8_MsgBitReport servoloop_test_results_ServoloopTestResults_test_sl9_microprocessor is equal to false
2026-02-03 10:01:22,756 INFO OK: read value = false
2026-02-03 10:01:22,756 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp10_board_overall is equal to false
2026-02-03 10:01:22,757 INFO OK: read value = false
2026-02-03 10:01:22,757 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp11_attenuatori_antenna is equal to false
2026-02-03 10:01:22,757 INFO OK: read value = false
2026-02-03 10:01:22,758 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp14_external_sp_if is equal to false
2026-02-03 10:01:22,758 INFO OK: read value = false
2026-02-03 10:01:22,758 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp16_bcn is equal to false
2026-02-03 10:01:22,759 INFO OK: read value = false
2026-02-03 10:01:22,759 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp1_timer1_up is equal to false
2026-02-03 10:01:22,759 INFO OK: read value = false
2026-02-03 10:01:22,759 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp2_timer_dma_pxc_if is equal to false
2026-02-03 10:01:22,759 INFO OK: read value = false
2026-02-03 10:01:22,760 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp3_timer_internal is equal to false
2026-02-03 10:01:22,760 INFO OK: read value = false
2026-02-03 10:01:22,760 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp4_px_ctrl_comm is equal to false
2026-02-03 10:01:22,760 INFO OK: read value = false
2026-02-03 10:01:22,760 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp5_video1_without_ad is equal to false
2026-02-03 10:01:22,761 INFO OK: read value = false
2026-02-03 10:01:22,761 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp6_video1_with_ad is equal to false
2026-02-03 10:01:22,761 INFO OK: read value = false
2026-02-03 10:01:22,761 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp7_video2_ad_sync is equal to false
2026-02-03 10:01:22,762 INFO OK: read value = false
2026-02-03 10:01:22,762 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp8_video2_timer_sync is equal to false
2026-02-03 10:01:22,763 INFO OK: read value = false
2026-02-03 10:01:22,763 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9_ad_da is equal to false
2026-02-03 10:01:22,763 INFO OK: read value = false
2026-02-03 10:01:22,763 INFO Check that B8_MsgBitReport signal_processor_test_results_SignalProcessorTestResults_test_sp9b_wideband_expander is equal to false
2026-02-03 10:01:22,764 INFO OK: read value = false
2026-02-03 10:01:22,764 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx10_hv_ps_over_temperature_warning is equal to false
2026-02-03 10:01:22,764 INFO OK: read value = false
2026-02-03 10:01:22,765 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx11_twt_helix_over_current is equal to false
2026-02-03 10:01:22,765 INFO OK: read value = false
2026-02-03 10:01:22,765 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx12_cathode_to_helix_arc is equal to false
2026-02-03 10:01:22,765 INFO OK: read value = false
2026-02-03 10:01:22,765 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx13_twt_over_temperature_hazard is equal to false
2026-02-03 10:01:22,766 INFO OK: read value = false
2026-02-03 10:01:22,766 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx14_twt_over_temperature_warning is equal to false
2026-02-03 10:01:22,766 INFO OK: read value = false
2026-02-03 10:01:22,766 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx15_cathode_under_voltage is equal to false
2026-02-03 10:01:22,767 INFO OK: read value = false
2026-02-03 10:01:22,767 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx16_cathode_over_voltage is equal to false
2026-02-03 10:01:22,767 INFO OK: read value = false
2026-02-03 10:01:22,767 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx1_microprocessors is equal to false
2026-02-03 10:01:22,767 INFO OK: read value = false
2026-02-03 10:01:22,767 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx2_tx_rf_input is equal to false
2026-02-03 10:01:22,768 INFO OK: read value = false
2026-02-03 10:01:22,768 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx3_twt_rf_input is equal to false
2026-02-03 10:01:22,768 INFO OK: read value = false
2026-02-03 10:01:22,768 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx4_twt_rf_output is equal to false
2026-02-03 10:01:22,768 INFO OK: read value = false
2026-02-03 10:01:22,769 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx5_tx_rf_output_level is equal to false
2026-02-03 10:01:22,769 INFO OK: read value = false
2026-02-03 10:01:22,769 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx6_vswr is equal to false
2026-02-03 10:01:22,769 INFO OK: read value = false
2026-02-03 10:01:22,770 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx7_three_phase_input_power is equal to false
2026-02-03 10:01:22,770 INFO OK: read value = false
2026-02-03 10:01:22,770 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx8_low_voltage_power_supplies is equal to false
2026-02-03 10:01:22,770 INFO OK: read value = false
2026-02-03 10:01:22,770 INFO Check that B8_MsgBitReport transmitter_test_results_w1_TransmitterTestResultsW1_test_tx9_hv_ps_over_temperature_hazard is equal to false
2026-02-03 10:01:22,770 INFO OK: read value = false
2026-02-03 10:01:22,771 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx17_collector_under_voltage is equal to false
2026-02-03 10:01:22,771 INFO OK: read value = false
2026-02-03 10:01:22,771 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx18_collector_over_voltage is equal to false
2026-02-03 10:01:22,771 INFO OK: read value = false
2026-02-03 10:01:22,771 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx19_rectified_voltage is equal to false
2026-02-03 10:01:22,771 INFO OK: read value = false
2026-02-03 10:01:22,772 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx20_cathode_inv_current_fail is equal to false
2026-02-03 10:01:22,772 INFO OK: read value = false
2026-02-03 10:01:22,772 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx21_collector_inv_current_fail is equal to false
2026-02-03 10:01:22,772 INFO OK: read value = false
2026-02-03 10:01:22,773 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx22_waveguide_pressurization is equal to false
2026-02-03 10:01:22,773 INFO OK: read value = false
2026-02-03 10:01:22,773 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx23_grid_window_over_duty_alt is equal to false
2026-02-03 10:01:22,773 INFO OK: read value = false
2026-02-03 10:01:22,773 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx24_floating_deck_fail is equal to false
2026-02-03 10:01:22,773 INFO OK: read value = false
2026-02-03 10:01:22,774 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx25_floating_deck_ps_fail is equal to false
2026-02-03 10:01:22,774 INFO OK: read value = false
2026-02-03 10:01:22,774 INFO Check that B8_MsgBitReport transmitter_test_results_w2_TransmitterTestResultsW2_test_tx26_grid_window_over_duty is equal to false
2026-02-03 10:01:22,774 INFO OK: read value = false
2026-02-03 10:01:22,774 INFO [Run 2] B8 Diagnostics: 173 checked, 172 pass, 1 fail
2026-02-03 10:01:22,774 WARNING B8_Degradation: 1 failures - fail
2026-02-03 10:01:22,774 INFO 0.0s remaining ...
2026-02-03 10:01:22,775 INFO [Run 2] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-02-03 10:01:22,775 INFO Target Detection Test
2026-02-03 10:01:22,775 INFO [Run 2] Starting target detection test (timeout: 10.0s)
2026-02-03 10:01:22,775 INFO Setting radar to operational mode before target test (best-effort)
2026-02-03 10:01:22,775 INFO Executing auxiliary serial sequence to prepare radar
2026-02-03 10:01:22,776 INFO Opening serial port: COM5 @ 115200bps
2026-02-03 10:01:22,777 ERROR Error in send_serial_sequence: could not open port 'COM5': FileNotFoundError(2, 'Impossibile trovare il file specificato.', None, 2)
Traceback (most recent call last):
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\serial_aux.py", line 99, in send_serial_sequence
parity=PARITY, stopbits=STOPBITS, timeout=0.2)
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\PlatformSimulator\bin\python37.zip\serial\serialwin32.py", line 31, in __init__
super(Serial, self).__init__(*args, **kwargs)
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\PlatformSimulator\bin\python37.zip\serial\serialutil.py", line 240, in __init__
self.open()
File "C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\PlatformSimulator\bin\python37.zip\serial\serialwin32.py", line 62, in open
raise SerialException("could not open port {!r}: {!r}".format(self.portstr, ctypes.WinError()))
serial.serialutil.SerialException: could not open port 'COM5': FileNotFoundError(2, 'Impossibile trovare il file specificato.', None, 2)
2026-02-03 10:01:22,786 WARNING Aux serial sequence failed: could not open port 'COM5': FileNotFoundError(2, 'Impossibile trovare il file specificato.', None, 2)
2026-02-03 10:01:22,787 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_silence to 1
2026-02-03 10:01:22,787 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_silence = 1
2026-02-03 10:01:22,991 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_silence -> 1 : True
2026-02-03 10:01:22,991 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby to 1
2026-02-03 10:01:22,991 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_stby = 1
2026-02-03 10:01:23,192 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby -> 1 : True
2026-02-03 10:01:25,194 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity to 127
2026-02-03 10:01:25,194 DEBUG [MOCK] assignMessageFieldValue: A1_MsgRdrSettingsAndParameters.settings_RDROperationalSettings_rdr_symbology_intensity = 127
2026-02-03 10:01:25,396 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_rdr_symbology_intensity -> 127 : True
2026-02-03 10:01:25,396 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_target_history to 3
2026-02-03 10:01:25,396 DEBUG [MOCK] assignMessageFieldValue: A1_MsgRdrSettingsAndParameters.settings_RDROperationalSettings_target_history = 3
2026-02-03 10:01:25,610 INFO Set A1_MsgRdrSettingsAndParameters settings_RDROperationalSettings_target_history -> 3 : True
2026-02-03 10:01:25,610 INFO Set A2_MsgRdrOperationCommand param1_RdrFunAndParam1_range_scale_selection to 1
2026-02-03 10:01:25,610 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.param1_RdrFunAndParam1_range_scale_selection = 1
2026-02-03 10:01:25,818 INFO Set A2_MsgRdrOperationCommand param1_RdrFunAndParam1_range_scale_selection -> 1 : True
2026-02-03 10:01:25,819 INFO Set A2_MsgRdrModeCommand rdr_mode_command_master_mode to RWS
2026-02-03 10:01:25,819 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrModeCommand.rdr_mode_command_master_mode = RWS
2026-02-03 10:01:26,026 INFO Set A2_MsgRdrModeCommand rdr_mode_command_master_mode -> RWS : True
2026-02-03 10:01:26,026 INFO Set A2_MsgRdrModeCommand param1_gm_submode to 0
2026-02-03 10:01:26,026 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrModeCommand.param1_gm_submode = 0
2026-02-03 10:01:26,228 INFO Set A2_MsgRdrModeCommand param1_gm_submode -> 0 : True
2026-02-03 10:01:26,228 INFO Set A4_MsgValidityAndSlew validity_and_slew_raw to 0
2026-02-03 10:01:26,228 DEBUG [MOCK] assignMessageFieldValue: A4_MsgValidityAndSlew.validity_and_slew_raw = 0
2026-02-03 10:01:26,433 INFO Set A4_MsgValidityAndSlew validity_and_slew_raw -> 0 : True
2026-02-03 10:01:26,433 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_stby_tellback is equal to STBY_ON
2026-02-03 10:01:26,433 INFO OK: read value = STBY_ON
2026-02-03 10:01:26,434 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_rf_radiation_status is equal to RADIATION_OFF
2026-02-03 10:01:26,434 INFO OK: read value = RADIATION_OFF
2026-02-03 10:01:26,434 INFO Removing STBY before target acquisition to enable radar TX
2026-02-03 10:01:26,434 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby to 0
2026-02-03 10:01:26,435 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_stby = 0
2026-02-03 10:01:28,647 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_stby_tellback is equal to STBY_OFF
2026-02-03 10:01:28,648 INFO OK: read value = STBY_OFF
2026-02-03 10:01:28,648 INFO tgt_gen() - timeout: 10.0s
2026-02-03 10:01:28,663 INFO TgtMsg: 2 2
2026-02-03 10:01:28,815 INFO TgtMsg: 12 10
2026-02-03 10:01:28,966 INFO TgtMsg: 22 10
2026-02-03 10:01:29,132 INFO TgtMsg: 32 10
2026-02-03 10:01:29,287 INFO TgtMsg: 42 10
2026-02-03 10:01:29,449 INFO TgtMsg: 52 10
2026-02-03 10:01:29,605 INFO TgtMsg: 62 10
2026-02-03 10:01:29,767 INFO TgtMsg: 72 10
2026-02-03 10:01:29,926 INFO TgtMsg: 82 10
2026-02-03 10:01:30,102 INFO TgtMsg: 92 10
2026-02-03 10:01:30,223 DEBUG [MOCK] Message B9: counter at 100
2026-02-03 10:01:30,255 INFO TgtMsg: 102 10
2026-02-03 10:01:30,417 INFO TgtMsg: 112 10
2026-02-03 10:01:30,578 INFO TgtMsg: 122 10
2026-02-03 10:01:30,734 INFO TgtMsg: 132 10
2026-02-03 10:01:30,881 INFO TgtMsg: 142 10
2026-02-03 10:01:31,042 INFO TgtMsg: 152 10
2026-02-03 10:01:31,207 INFO TgtMsg: 162 10
2026-02-03 10:01:31,368 INFO TgtMsg: 172 10
2026-02-03 10:01:31,522 INFO TgtMsg: 182 10
2026-02-03 10:01:31,686 INFO TgtMsg: 192 10
2026-02-03 10:01:31,804 DEBUG [MOCK] Message B9: counter at 200
2026-02-03 10:01:31,836 INFO TgtMsg: 202 10
2026-02-03 10:01:31,999 INFO TgtMsg: 212 10
2026-02-03 10:01:32,160 INFO TgtMsg: 222 10
2026-02-03 10:01:32,331 INFO TgtMsg: 232 10
2026-02-03 10:01:32,509 INFO TgtMsg: 242 10
2026-02-03 10:01:32,675 INFO TgtMsg: 252 10
2026-02-03 10:01:32,846 INFO TgtMsg: 262 10
2026-02-03 10:01:33,000 INFO TgtMsg: 272 10
2026-02-03 10:01:33,171 INFO TgtMsg: 282 10
2026-02-03 10:01:33,330 INFO TgtMsg: 292 10
2026-02-03 10:01:33,456 DEBUG [MOCK] Message B9: counter at 300
2026-02-03 10:01:33,467 INFO Ctrl-C detected, exiting gracefully...
2026-02-03 10:01:33,483 INFO TgtMsg: 302 10
2026-02-03 10:01:33,483 INFO Re-enabling STBY after target test
2026-02-03 10:01:33,483 INFO Set A2_MsgRdrOperationCommand rdr_mode_command_RdrModeCommandWord_stby to 1
2026-02-03 10:01:33,483 DEBUG [MOCK] assignMessageFieldValue: A2_MsgRdrOperationCommand.rdr_mode_command_RdrModeCommandWord_stby = 1
2026-02-03 10:01:33,596 INFO Ctrl-C detected, exiting gracefully...
2026-02-03 10:01:33,853 INFO Ctrl-C detected, exiting gracefully...
2026-02-03 10:01:34,945 INFO Ctrl-C detected, exiting gracefully...
2026-02-03 10:01:35,138 INFO Ctrl-C detected, exiting gracefully...
2026-02-03 10:01:35,303 INFO Ctrl-C detected, exiting gracefully...
2026-02-03 10:01:35,462 INFO Ctrl-C detected, exiting gracefully...
2026-02-03 10:01:35,693 INFO Check that B7_MsgRdrStatusTellback rdr_mode_tellback_RdrStatusTellback_stby_tellback is equal to STBY_ON
2026-02-03 10:01:35,694 INFO OK: read value = STBY_ON
2026-02-03 10:01:35,694 INFO Target NOT detected (timeout after 4.83s)
2026-02-03 10:01:35,694 WARNING [Run 2] Target NOT DETECTED (timeout: 4.83s)
2026-02-03 10:01:35,695 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 10
Total Step 204: Success 200 (98.04%), Failed 4 (1.96%),
2026-02-03 10:01:35,695 INFO Test interrupted by user (Ctrl-C)
2026-02-03 10:01:35,695 INFO Repetitions terminated.
2026-02-03 10:01:35,696 INFO [Report] Custom statistics data registered for PDF generation
2026-02-03 10:01:35,696 INFO ==========================================================================================
2026-02-03 10:01:35,696 INFO FINAL TEST STATISTICS SUMMARY
2026-02-03 10:01:35,696 INFO ==========================================================================================
2026-02-03 10:01:35,697 INFO Total Runs: 2
2026-02-03 10:01:35,697 INFO Successful: 0 (0.0%)
2026-02-03 10:01:35,697 INFO Failed: 2 (100.0%)
2026-02-03 10:01:35,698 INFO B6 Checks: 24 (Pass: 18, Fail: 4, Known: 2)
2026-02-03 10:01:35,698 INFO B8 Checks: 346 (Pass: 341, Fail: 5)
2026-02-03 10:01:35,699 INFO Serial: 0 messages (0 errors, 0 fatal, 0 recycles)
2026-02-03 10:01:35,699 INFO Target: 1 detected, 1 not detected (50.0% pass rate)
2026-02-03 10:01:35,700 INFO PBIT Timing: avg=0.24s, min=0.23s, max=0.24s, σ=0.00s
2026-02-03 10:01:35,700 INFO ==========================================================================================
2026-02-03 10:01:35,700 INFO Detailed statistics will be available in the PDF report
2026-02-03 10:01:35,700 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260203_100135_statistics.csv
2026-02-03 10:01:35,725 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260203_100135_statistics.csv
2026-02-03 10:01:35,728 INFO Statistics exported successfully to JSON: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260203_100135_statistics.json
2026-02-03 10:01:35,729 INFO Set MAIN_POWER to False
2026-02-03 10:01:35,729 INFO [MOCK] Power OFF
2026-02-03 10:01:35,729 INFO [MOCK] 1553 Interface stopped
2026-02-03 10:01:40,740 INFO Check that MAIN_POWER is equal to 0
2026-02-03 10:01:40,740 INFO OK: read value = False
2026-02-03 10:01:40,740 INFO [MOCK] Serial terminal disconnected
2026-02-03 10:01:40,740 INFO Stop Time: 2026-02-03 10:00:43.125990
2026-02-03 10:01:40,740 INFO Test execution time: 0:00:57.614933