2026-01-30 17:11:17,325 INFO Start Time: 2026-01-30 17:11:17.325979
2026-01-30 17:11:17,326 INFO [MOCK] Serial terminal initialized
2026-01-30 17:11:17,326 INFO [MOCK] Serial terminal connected
2026-01-30 17:11:17,326 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 17:11:17,327 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-01-30 17:11:17,327 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts
2026-01-30 17:11:17,338 INFO tgt_gen_alone(): 0
2026-01-30 17:11:17,338 INFO tgt_gen()
2026-01-30 17:11:17,362 WARNING [MOCK] getSingleMessageReceivedSz called but interface not started! Returning 0
2026-01-30 17:11:17,362 INFO TgtMsg: 0 0
2026-01-30 17:11:17,362 INFO Tgt: 1 @ 1180
2026-01-30 17:11:17,363 INFO Check that B9 b9_t_num is between 1 and 2
2026-01-30 17:11:17,363 INFO OK: read value = 1
2026-01-30 17:11:17,363 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-01-30 17:11:17,363 DEBUG [MOCK] Field rng: 1180
2026-01-30 17:11:17,363 INFO OK: read value = 1180
2026-01-30 17:11:17,363 INFO [MOCK] Log stopped
2026-01-30 17:11:17,363 INFO Repetition 1 of 3
2026-01-30 17:11:17,363 DEBUG [MOCK] Serial statistics reset
2026-01-30 17:11:17,363 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-01-30 17:11:17,364 INFO Set MAIN_POWER to False
2026-01-30 17:11:17,364 INFO [MOCK] Power OFF
2026-01-30 17:11:17,364 INFO [MOCK] 1553 Interface stopped
2026-01-30 17:11:22,375 INFO Check that MAIN_POWER is equal to 0
2026-01-30 17:11:22,375 INFO OK: read value = False
2026-01-30 17:11:25,380 INFO The test operator is required to switch on the target.
2026-01-30 17:11:25,380 INFO Set MAIN_POWER to True
2026-01-30 17:11:25,380 INFO [MOCK] Power ON
2026-01-30 17:11:25,383 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-01-30 17:11:25,383 INFO run_count = 1
2026-01-30 17:11:25,383 INFO SIMULATION_SCENARIO = 'mixed'
2026-01-30 17:11:25,383 INFO current_scenario = 'mixed'
2026-01-30 17:11:25,383 INFO _scenario_list = ['random_failures', 'recycle_recovery_1', 'normal']
2026-01-30 17:11:25,383 INFO [DEBUG] Entering MIXED MODE branch
2026-01-30 17:11:25,383 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='random_failures'
2026-01-30 17:11:25,383 INFO [DEBUG] About to call _log_scenario_info('random_failures', 1, 3)
2026-01-30 17:11:25,383 INFO
2026-01-30 17:11:25,383 INFO ####################################################################################################
2026-01-30 17:11:25,383 INFO ####################################################################################################
2026-01-30 17:11:25,387 INFO ### RUN 1/3: RANDOM COMPONENT FAILURES
2026-01-30 17:11:25,387 INFO ####################################################################################################
2026-01-30 17:11:25,387 INFO
2026-01-30 17:11:25,388 INFO SCENARIO: random_failures
2026-01-30 17:11:25,388 INFO DESCRIPTION: Random selection of component failures (30% proc, 20% tx, 15% rx)
2026-01-30 17:11:25,388 INFO
2026-01-30 17:11:25,388 INFO EXPECTED FAILURES:
2026-01-30 17:11:25,388 INFO ✗ Variable - one or more of: processor_status, trasmitter_status, receiver_status
2026-01-30 17:11:25,389 INFO
2026-01-30 17:11:25,389 INFO EXPECTED PASSES:
2026-01-30 17:11:25,389 INFO ✓ Non-failed components
2026-01-30 17:11:25,389 INFO ✓ B8 diagnostic fields
2026-01-30 17:11:25,389 INFO ✓ Target generation
2026-01-30 17:11:25,389 INFO
2026-01-30 17:11:25,389 INFO NOTES: Validates test handling of multiple simultaneous failures
2026-01-30 17:11:25,390 INFO
2026-01-30 17:11:25,390 INFO ####################################################################################################
2026-01-30 17:11:25,390 INFO ####################################################################################################
2026-01-30 17:11:25,390 INFO
2026-01-30 17:11:25,393 INFO [DEBUG] _log_scenario_info() completed
2026-01-30 17:11:25,393 INFO [MOCK APPLY] ✓ No random failures triggered (all passed)
2026-01-30 17:11:25,393 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 1)
2026-01-30 17:11:30,404 INFO Check that MAIN_POWER is equal to 1
2026-01-30 17:11:30,404 INFO OK: read value = True
2026-01-30 17:11:30,404 INFO [MOCK] BIT report available after 5.0s
2026-01-30 17:11:30,438 INFO BIT report available after 0.0s
2026-01-30 17:11:30,438 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-01-30 17:11:30,438 INFO OK: read value = false
2026-01-30 17:11:30,438 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-01-30 17:11:30,438 WARNING CHECK ERROR: read value = true
2026-01-30 17:11:30,438 ERROR INTERFACE ERROR: Expected false, got true
2026-01-30 17:11:30,438 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-01-30 17:11:30,439 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-01-30 17:11:30,439 INFO OK: read value = false
2026-01-30 17:11:30,439 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-01-30 17:11:30,439 INFO OK: read value = false
2026-01-30 17:11:30,439 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-01-30 17:11:30,439 INFO OK: read value = false
2026-01-30 17:11:30,439 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-01-30 17:11:30,439 INFO OK: read value = false
2026-01-30 17:11:30,439 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-01-30 17:11:30,439 INFO OK: read value = false
2026-01-30 17:11:30,439 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-01-30 17:11:30,439 INFO OK: read value = false
2026-01-30 17:11:30,440 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-01-30 17:11:30,440 INFO OK: read value = false
2026-01-30 17:11:30,440 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-01-30 17:11:30,440 INFO OK: read value = false
2026-01-30 17:11:30,440 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-01-30 17:11:30,440 INFO OK: read value = false
2026-01-30 17:11:30,440 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-01-30 17:11:30,440 WARNING CHECK ERROR: read value = RDR_OK
2026-01-30 17:11:30,440 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-01-30 17:11:30,440 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-01-30 17:11:30,441 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-01-30 17:11:30,441 INFO Known failures (HW setup): 2
2026-01-30 17:11:30,441 INFO [Run 1] All B6 LRU Status PASS (no B8 drill-down needed)
2026-01-30 17:11:30,441 INFO 0.0s remaining ...
2026-01-30 17:11:30,441 INFO [Run 1] Serial: 0 total, 0 errors, 0 fatal, 0 recycles
2026-01-30 17:11:30,441 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3
Total Step 18: Success 16 (88.89%), Failed 2 (11.11%),
2026-01-30 17:11:30,441 INFO Repetition 2 of 3
2026-01-30 17:11:30,441 DEBUG [MOCK] Serial statistics reset
2026-01-30 17:11:30,441 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-01-30 17:11:30,441 INFO Set MAIN_POWER to False
2026-01-30 17:11:30,441 INFO [MOCK] Power OFF
2026-01-30 17:11:30,442 INFO [MOCK] 1553 Interface stopped
2026-01-30 17:11:35,451 INFO Check that MAIN_POWER is equal to 0
2026-01-30 17:11:35,451 INFO OK: read value = False
2026-01-30 17:11:38,463 INFO The test operator is required to switch on the target.
2026-01-30 17:11:38,463 INFO Set MAIN_POWER to True
2026-01-30 17:11:38,465 INFO [MOCK] Power ON
2026-01-30 17:11:38,465 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-01-30 17:11:38,467 INFO run_count = 2
2026-01-30 17:11:38,467 INFO SIMULATION_SCENARIO = 'mixed'
2026-01-30 17:11:38,467 INFO current_scenario = 'mixed'
2026-01-30 17:11:38,467 INFO _scenario_list = ['random_failures', 'recycle_recovery_1', 'normal']
2026-01-30 17:11:38,469 INFO [DEBUG] Entering MIXED MODE branch
2026-01-30 17:11:38,469 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='recycle_recovery_1'
2026-01-30 17:11:38,469 INFO [DEBUG] About to call _log_scenario_info('recycle_recovery_1', 2, 3)
2026-01-30 17:11:38,471 INFO
2026-01-30 17:11:38,471 INFO ####################################################################################################
2026-01-30 17:11:38,471 INFO ####################################################################################################
2026-01-30 17:11:38,471 INFO ### RUN 2/3: RECYCLE SELF-HEALING (1 CYCLE)
2026-01-30 17:11:38,471 INFO ####################################################################################################
2026-01-30 17:11:38,471 INFO
2026-01-30 17:11:38,471 INFO SCENARIO: recycle_recovery_1
2026-01-30 17:11:38,472 INFO DESCRIPTION: Processor fails, then auto-recovers after 1 RECYCLE event
2026-01-30 17:11:38,472 INFO
2026-01-30 17:11:38,472 INFO EXPECTED FAILURES:
2026-01-30 17:11:38,472 INFO ✗ Initial: processor_status = FAIL
2026-01-30 17:11:38,472 INFO ✗ Serial: 1x RECYCLE event detected
2026-01-30 17:11:38,474 INFO
2026-01-30 17:11:38,475 INFO EXPECTED PASSES:
2026-01-30 17:11:38,475 INFO ✓ After RECYCLE: processor_status = PASS
2026-01-30 17:11:38,475 INFO ✓ Final: All systems OK
2026-01-30 17:11:38,475 INFO
2026-01-30 17:11:38,475 INFO NOTES: Simulates transient failure with fast self-healing. Test should detect RECYCLE and eventual recovery
2026-01-30 17:11:38,476 INFO
2026-01-30 17:11:38,476 INFO ####################################################################################################
2026-01-30 17:11:38,476 INFO ####################################################################################################
2026-01-30 17:11:38,476 INFO
2026-01-30 17:11:38,476 INFO [DEBUG] _log_scenario_info() completed
2026-01-30 17:11:38,476 INFO [MOCK APPLY] ⚠ RECYCLE scenario enabled: 1 cycle to recovery
2026-01-30 17:11:38,476 INFO [MOCK RECYCLE] Initial processor failure detected
2026-01-30 17:11:38,991 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 17:11:39,299 INFO [MOCK RECYCLE] System recovered after 1 RECYCLE (self-healing)
2026-01-30 17:11:39,299 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-01-30 17:11:44,313 INFO Check that MAIN_POWER is equal to 1
2026-01-30 17:11:44,313 INFO OK: read value = True
2026-01-30 17:11:44,313 INFO [MOCK] BIT report available after 5.8s
2026-01-30 17:11:44,346 INFO BIT report available after 0.0s
2026-01-30 17:11:44,346 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-01-30 17:11:44,346 INFO OK: read value = false
2026-01-30 17:11:44,346 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-01-30 17:11:44,348 WARNING CHECK ERROR: read value = true
2026-01-30 17:11:44,348 ERROR INTERFACE ERROR: Expected false, got true
2026-01-30 17:11:44,348 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-01-30 17:11:44,348 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-01-30 17:11:44,348 INFO OK: read value = false
2026-01-30 17:11:44,348 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-01-30 17:11:44,348 INFO OK: read value = false
2026-01-30 17:11:44,348 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-01-30 17:11:44,348 INFO OK: read value = false
2026-01-30 17:11:44,348 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-01-30 17:11:44,349 INFO OK: read value = false
2026-01-30 17:11:44,349 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-01-30 17:11:44,349 INFO OK: read value = false
2026-01-30 17:11:44,349 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-01-30 17:11:44,349 INFO OK: read value = false
2026-01-30 17:11:44,349 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-01-30 17:11:44,349 INFO OK: read value = false
2026-01-30 17:11:44,349 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-01-30 17:11:44,349 INFO OK: read value = false
2026-01-30 17:11:44,349 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-01-30 17:11:44,349 INFO OK: read value = false
2026-01-30 17:11:44,350 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-01-30 17:11:44,350 WARNING CHECK ERROR: read value = RDR_OK
2026-01-30 17:11:44,350 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-01-30 17:11:44,350 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-01-30 17:11:44,350 INFO [Run 2] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-01-30 17:11:44,350 INFO Known failures (HW setup): 2
2026-01-30 17:11:44,350 INFO [Run 2] All B6 LRU Status PASS (no B8 drill-down needed)
2026-01-30 17:11:44,350 INFO 0.0s remaining ...
2026-01-30 17:11:44,350 INFO [Run 2] Serial: 1 total, 0 errors, 1 fatal, 1 recycles
2026-01-30 17:11:44,351 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3
Total Step 16: Success 14 (87.50%), Failed 2 (12.50%),
2026-01-30 17:11:44,351 INFO Repetition 3 of 3
2026-01-30 17:11:44,351 DEBUG [MOCK] Serial statistics reset
2026-01-30 17:11:44,351 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-01-30 17:11:44,351 INFO Set MAIN_POWER to False
2026-01-30 17:11:44,351 INFO [MOCK] Power OFF
2026-01-30 17:11:44,351 INFO [MOCK] 1553 Interface stopped
2026-01-30 17:11:49,351 INFO Check that MAIN_POWER is equal to 0
2026-01-30 17:11:49,351 INFO OK: read value = False
2026-01-30 17:11:52,357 INFO The test operator is required to switch on the target.
2026-01-30 17:11:52,357 INFO Set MAIN_POWER to True
2026-01-30 17:11:52,357 INFO [MOCK] Power ON
2026-01-30 17:11:52,357 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-01-30 17:11:52,357 INFO run_count = 3
2026-01-30 17:11:52,357 INFO SIMULATION_SCENARIO = 'mixed'
2026-01-30 17:11:52,357 INFO current_scenario = 'mixed'
2026-01-30 17:11:52,357 INFO _scenario_list = ['random_failures', 'recycle_recovery_1', 'normal']
2026-01-30 17:11:52,357 INFO [DEBUG] Entering MIXED MODE branch
2026-01-30 17:11:52,357 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='normal'
2026-01-30 17:11:52,357 INFO [DEBUG] About to call _log_scenario_info('normal', 3, 3)
2026-01-30 17:11:52,357 INFO
2026-01-30 17:11:52,357 INFO ####################################################################################################
2026-01-30 17:11:52,357 INFO ####################################################################################################
2026-01-30 17:11:52,357 INFO ### RUN 3/3: NORMAL OPERATION
2026-01-30 17:11:52,357 INFO ####################################################################################################
2026-01-30 17:11:52,357 INFO
2026-01-30 17:11:52,357 INFO SCENARIO: normal
2026-01-30 17:11:52,357 INFO DESCRIPTION: All systems operational - no failures
2026-01-30 17:11:52,357 INFO
2026-01-30 17:11:52,357 INFO EXPECTED FAILURES:
2026-01-30 17:11:52,357 INFO (none)
2026-01-30 17:11:52,357 INFO
2026-01-30 17:11:52,357 INFO EXPECTED PASSES:
2026-01-30 17:11:52,357 INFO ✓ All B6 status fields (except pedestal)
2026-01-30 17:11:52,357 INFO ✓ All B8 diagnostic fields
2026-01-30 17:11:52,357 INFO ✓ Target generation
2026-01-30 17:11:52,357 INFO
2026-01-30 17:11:52,357 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present)
2026-01-30 17:11:52,357 INFO
2026-01-30 17:11:52,363 INFO ####################################################################################################
2026-01-30 17:11:52,363 INFO ####################################################################################################
2026-01-30 17:11:52,363 INFO
2026-01-30 17:11:52,364 INFO [DEBUG] _log_scenario_info() completed
2026-01-30 17:11:52,364 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected)
2026-01-30 17:11:52,364 INFO [MOCK RECYCLE] Initial processor failure detected
2026-01-30 17:11:52,882 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 17:11:53,191 INFO [MOCK RECYCLE] System recovered after 1 RECYCLE (self-healing)
2026-01-30 17:11:53,191 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3)
2026-01-30 17:11:58,195 INFO Check that MAIN_POWER is equal to 1
2026-01-30 17:11:58,195 INFO OK: read value = True
2026-01-30 17:11:58,195 INFO [MOCK] BIT report available after 5.8s
2026-01-30 17:11:58,229 INFO BIT report available after 0.0s
2026-01-30 17:11:58,229 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-01-30 17:11:58,229 INFO OK: read value = false
2026-01-30 17:11:58,229 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-01-30 17:11:58,229 WARNING CHECK ERROR: read value = true
2026-01-30 17:11:58,229 ERROR INTERFACE ERROR: Expected false, got true
2026-01-30 17:11:58,229 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-01-30 17:11:58,230 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-01-30 17:11:58,230 INFO OK: read value = false
2026-01-30 17:11:58,230 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-01-30 17:11:58,230 INFO OK: read value = false
2026-01-30 17:11:58,230 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-01-30 17:11:58,230 INFO OK: read value = false
2026-01-30 17:11:58,232 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-01-30 17:11:58,232 INFO OK: read value = false
2026-01-30 17:11:58,232 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-01-30 17:11:58,232 INFO OK: read value = false
2026-01-30 17:11:58,232 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-01-30 17:11:58,233 INFO OK: read value = false
2026-01-30 17:11:58,233 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-01-30 17:11:58,233 INFO OK: read value = false
2026-01-30 17:11:58,233 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-01-30 17:11:58,234 INFO OK: read value = false
2026-01-30 17:11:58,234 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-01-30 17:11:58,234 INFO OK: read value = false
2026-01-30 17:11:58,234 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-01-30 17:11:58,234 WARNING CHECK ERROR: read value = RDR_OK
2026-01-30 17:11:58,234 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-01-30 17:11:58,234 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-01-30 17:11:58,234 INFO [Run 3] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-01-30 17:11:58,234 INFO Known failures (HW setup): 2
2026-01-30 17:11:58,235 INFO [Run 3] All B6 LRU Status PASS (no B8 drill-down needed)
2026-01-30 17:11:58,235 INFO 0.0s remaining ...
2026-01-30 17:11:58,235 INFO [Run 3] Serial: 1 total, 0 errors, 1 fatal, 1 recycles
2026-01-30 17:11:58,235 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3
Total Step 16: Success 14 (87.50%), Failed 2 (12.50%),
2026-01-30 17:11:58,235 INFO tgt_gen()
2026-01-30 17:11:58,245 INFO TgtMsg: 1 1
2026-01-30 17:11:58,245 INFO Tgt: 1 @ 1180
2026-01-30 17:11:58,245 INFO Check that B9 b9_t_num is between 1 and 2
2026-01-30 17:11:58,245 INFO OK: read value = 1
2026-01-30 17:11:58,246 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-01-30 17:11:58,246 INFO OK: read value = 1180
2026-01-30 17:11:58,246 INFO Repetitions terminated.
2026-01-30 17:11:58,246 INFO [Report] Custom statistics data registered for PDF generation
2026-01-30 17:11:58,246 INFO ==========================================================================================
2026-01-30 17:11:58,247 INFO FINAL TEST STATISTICS SUMMARY
2026-01-30 17:11:58,247 INFO ==========================================================================================
2026-01-30 17:11:58,247 INFO Total Runs: 3
2026-01-30 17:11:58,247 INFO Successful: 3 (100.0%)
2026-01-30 17:11:58,247 INFO Failed: 0 (0.0%)
2026-01-30 17:11:58,247 INFO B6 Checks: 36 (Pass: 30, Fail: 0, Known: 6)
2026-01-30 17:11:58,248 INFO B8 Checks: 0 (Pass: 0, Fail: 0)
2026-01-30 17:11:58,249 INFO Serial: 2 messages (0 errors, 2 fatal, 2 recycles)
2026-01-30 17:11:58,250 INFO PBIT Timing: avg=0.03s, min=0.03s, max=0.03s, σ=0.00s
2026-01-30 17:11:58,250 INFO ==========================================================================================
2026-01-30 17:11:58,250 INFO Detailed statistics will be available in the PDF report
2026-01-30 17:11:58,251 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260130_171158_statistics.csv
2026-01-30 17:11:58,258 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260130_171158_statistics.csv
2026-01-30 17:11:58,259 INFO Statistics exported successfully to JSON: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260130_171158_statistics.json
2026-01-30 17:11:58,259 INFO Set MAIN_POWER to False
2026-01-30 17:11:58,260 INFO [MOCK] Power OFF
2026-01-30 17:11:58,260 INFO [MOCK] 1553 Interface stopped
2026-01-30 17:12:03,269 INFO Check that MAIN_POWER is equal to 0
2026-01-30 17:12:03,269 INFO OK: read value = False
2026-01-30 17:12:03,269 INFO [MOCK] Serial terminal disconnected
2026-01-30 17:12:03,269 INFO Stop Time: 2026-01-30 17:11:17.325979
2026-01-30 17:12:03,269 INFO Test execution time: 0:00:45.943470