2026-01-30 16:14:44,458 INFO Start Time: 2026-01-30 16:14:44.458330
2026-01-30 16:14:44,458 INFO [MOCK] Serial terminal initialized
2026-01-30 16:14:44,458 INFO [MOCK] Serial terminal connected
2026-01-30 16:14:44,458 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 16:14:44,565 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 16:14:44,565 INFO The Test Operator check if the failure BIT in B6_MsgRdrSettingsAndParametersTellback changes ...
2026-01-30 16:14:44,576 INFO [MOCK] Log started at level 3 in directory: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts
2026-01-30 16:14:44,577 INFO tgt_gen_alone(): 0
2026-01-30 16:14:44,577 INFO tgt_gen()
2026-01-30 16:14:44,597 INFO TgtMsg: 1 1
2026-01-30 16:14:44,597 INFO Tgt: 1 @ 1180
2026-01-30 16:14:44,598 INFO Check that B9 b9_t_num is between 1 and 2
2026-01-30 16:14:44,599 INFO OK: read value = 1
2026-01-30 16:14:44,599 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-01-30 16:14:44,599 INFO OK: read value = 1180
2026-01-30 16:14:44,599 INFO [MOCK] Log stopped
2026-01-30 16:14:44,600 INFO Repetition 1 of 3
2026-01-30 16:14:44,600 DEBUG [MOCK] Serial statistics reset
2026-01-30 16:14:44,600 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-01-30 16:14:44,600 INFO Set MAIN_POWER to False
2026-01-30 16:14:44,600 INFO [MOCK] Power OFF
2026-01-30 16:14:44,600 INFO [MOCK] 1553 Interface stopped
2026-01-30 16:14:49,617 INFO Check that MAIN_POWER is equal to 0
2026-01-30 16:14:49,617 INFO OK: read value = False
2026-01-30 16:14:52,628 INFO The test operator is required to switch on the target.
2026-01-30 16:14:52,628 INFO Set MAIN_POWER to True
2026-01-30 16:14:52,628 INFO [MOCK] Power ON
2026-01-30 16:14:52,628 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-01-30 16:14:52,628 INFO run_count = 2
2026-01-30 16:14:52,628 INFO SIMULATION_SCENARIO = 'mixed'
2026-01-30 16:14:52,628 INFO current_scenario = 'mixed'
2026-01-30 16:14:52,628 INFO _scenario_list = ['recycle_recovery_1', 'normal', 'random_failures']
2026-01-30 16:14:52,628 INFO [DEBUG] Entering MIXED MODE branch
2026-01-30 16:14:52,628 INFO [DEBUG] Mixed mode: scenario_index=1, selected scenario='normal'
2026-01-30 16:14:52,628 INFO [DEBUG] About to call _log_scenario_info('normal', 2, 3)
2026-01-30 16:14:52,628 INFO
2026-01-30 16:14:52,628 INFO ####################################################################################################
2026-01-30 16:14:52,628 INFO ####################################################################################################
2026-01-30 16:14:52,628 INFO ### RUN 2/3: NORMAL OPERATION
2026-01-30 16:14:52,628 INFO ####################################################################################################
2026-01-30 16:14:52,628 INFO
2026-01-30 16:14:52,628 INFO SCENARIO: normal
2026-01-30 16:14:52,635 INFO DESCRIPTION: All systems operational - no failures
2026-01-30 16:14:52,635 INFO
2026-01-30 16:14:52,635 INFO EXPECTED FAILURES:
2026-01-30 16:14:52,635 INFO (none)
2026-01-30 16:14:52,635 INFO
2026-01-30 16:14:52,635 INFO EXPECTED PASSES:
2026-01-30 16:14:52,635 INFO ✓ All B6 status fields (except pedestal)
2026-01-30 16:14:52,635 INFO ✓ All B8 diagnostic fields
2026-01-30 16:14:52,636 INFO ✓ Target generation
2026-01-30 16:14:52,636 INFO
2026-01-30 16:14:52,636 INFO NOTES: Pedestal always fails due to HW test setup limitation (unit not present)
2026-01-30 16:14:52,636 INFO
2026-01-30 16:14:52,636 INFO ####################################################################################################
2026-01-30 16:14:52,636 INFO ####################################################################################################
2026-01-30 16:14:52,636 INFO
2026-01-30 16:14:52,636 INFO [DEBUG] _log_scenario_info() completed
2026-01-30 16:14:52,636 INFO [MOCK APPLY] ✓ All systems nominal (no failures injected)
2026-01-30 16:14:52,637 INFO [MOCK RECYCLE] Initial processor failure detected
2026-01-30 16:14:53,143 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 16:14:53,458 INFO [MOCK RECYCLE] System recovered after 1 RECYCLE (self-healing)
2026-01-30 16:14:53,458 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 2)
2026-01-30 16:14:58,471 INFO Check that MAIN_POWER is equal to 1
2026-01-30 16:14:58,471 INFO OK: read value = True
2026-01-30 16:14:58,471 INFO [MOCK] BIT report available after 5.8s
2026-01-30 16:14:58,501 INFO BIT report available after 0.0s
2026-01-30 16:14:58,501 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-01-30 16:14:58,501 INFO OK: read value = false
2026-01-30 16:14:58,501 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-01-30 16:14:58,502 DEBUG [MOCK] Field status: true
2026-01-30 16:14:58,502 WARNING CHECK ERROR: read value = true
2026-01-30 16:14:58,502 ERROR INTERFACE ERROR: Expected false, got true
2026-01-30 16:14:58,502 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-01-30 16:14:58,502 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-01-30 16:14:58,502 INFO OK: read value = false
2026-01-30 16:14:58,503 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-01-30 16:14:58,503 INFO OK: read value = false
2026-01-30 16:14:58,503 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-01-30 16:14:58,503 INFO OK: read value = false
2026-01-30 16:14:58,503 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-01-30 16:14:58,503 INFO OK: read value = false
2026-01-30 16:14:58,503 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-01-30 16:14:58,503 INFO OK: read value = false
2026-01-30 16:14:58,504 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-01-30 16:14:58,504 INFO OK: read value = false
2026-01-30 16:14:58,504 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-01-30 16:14:58,504 INFO OK: read value = false
2026-01-30 16:14:58,505 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-01-30 16:14:58,505 INFO OK: read value = false
2026-01-30 16:14:58,505 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-01-30 16:14:58,505 INFO OK: read value = false
2026-01-30 16:14:58,506 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-01-30 16:14:58,506 WARNING CHECK ERROR: read value = RDR_OK
2026-01-30 16:14:58,506 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-01-30 16:14:58,507 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-01-30 16:14:58,508 INFO [Run 1] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-01-30 16:14:58,508 INFO Known failures (HW setup): 2
2026-01-30 16:14:58,508 INFO [Run 1] All B6 LRU Status PASS (no B8 drill-down needed)
2026-01-30 16:14:58,508 INFO 0.0s remaining ...
2026-01-30 16:14:58,508 INFO [Run 1] Serial: 1 total, 0 errors, 1 fatal, 1 recycles
2026-01-30 16:14:58,508 WARNING Session: GRIFO_M_PBIT : Repetition 1 of 3
Total Step 18: Success 16 (88.89%), Failed 2 (11.11%),
2026-01-30 16:14:58,509 INFO Repetition 2 of 3
2026-01-30 16:14:58,509 DEBUG [MOCK] Serial statistics reset
2026-01-30 16:14:58,510 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-01-30 16:14:58,510 INFO Set MAIN_POWER to False
2026-01-30 16:14:58,510 INFO [MOCK] Power OFF
2026-01-30 16:14:58,510 INFO [MOCK] 1553 Interface stopped
2026-01-30 16:15:03,511 INFO Check that MAIN_POWER is equal to 0
2026-01-30 16:15:03,511 INFO OK: read value = False
2026-01-30 16:15:06,522 INFO The test operator is required to switch on the target.
2026-01-30 16:15:06,522 INFO Set MAIN_POWER to True
2026-01-30 16:15:06,522 INFO [MOCK] Power ON
2026-01-30 16:15:06,522 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-01-30 16:15:06,522 INFO run_count = 3
2026-01-30 16:15:06,522 INFO SIMULATION_SCENARIO = 'mixed'
2026-01-30 16:15:06,522 INFO current_scenario = 'mixed'
2026-01-30 16:15:06,522 INFO _scenario_list = ['recycle_recovery_1', 'normal', 'random_failures']
2026-01-30 16:15:06,522 INFO [DEBUG] Entering MIXED MODE branch
2026-01-30 16:15:06,522 INFO [DEBUG] Mixed mode: scenario_index=2, selected scenario='random_failures'
2026-01-30 16:15:06,522 INFO [DEBUG] About to call _log_scenario_info('random_failures', 3, 3)
2026-01-30 16:15:06,522 INFO
2026-01-30 16:15:06,522 INFO ####################################################################################################
2026-01-30 16:15:06,528 INFO ####################################################################################################
2026-01-30 16:15:06,529 INFO ### RUN 3/3: RANDOM COMPONENT FAILURES
2026-01-30 16:15:06,529 INFO ####################################################################################################
2026-01-30 16:15:06,529 INFO
2026-01-30 16:15:06,529 INFO SCENARIO: random_failures
2026-01-30 16:15:06,531 INFO DESCRIPTION: Random selection of component failures (30% proc, 20% tx, 15% rx)
2026-01-30 16:15:06,532 INFO
2026-01-30 16:15:06,533 INFO EXPECTED FAILURES:
2026-01-30 16:15:06,533 INFO ✗ Variable - one or more of: processor_status, trasmitter_status, receiver_status
2026-01-30 16:15:06,533 INFO
2026-01-30 16:15:06,533 INFO EXPECTED PASSES:
2026-01-30 16:15:06,533 INFO ✓ Non-failed components
2026-01-30 16:15:06,533 INFO ✓ B8 diagnostic fields
2026-01-30 16:15:06,533 INFO ✓ Target generation
2026-01-30 16:15:06,534 INFO
2026-01-30 16:15:06,534 INFO NOTES: Validates test handling of multiple simultaneous failures
2026-01-30 16:15:06,534 INFO
2026-01-30 16:15:06,534 INFO ####################################################################################################
2026-01-30 16:15:06,534 INFO ####################################################################################################
2026-01-30 16:15:06,534 INFO
2026-01-30 16:15:06,534 INFO [DEBUG] _log_scenario_info() completed
2026-01-30 16:15:06,534 INFO [MOCK APPLY] ✗ Random failures applied: processor_status
2026-01-30 16:15:06,534 INFO [MOCK APPLY] ✗ Setting radar_fail_status = RDR_FAIL
2026-01-30 16:15:06,535 INFO [MOCK RECYCLE] Initial processor failure detected
2026-01-30 16:15:07,038 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 16:15:07,359 INFO [MOCK RECYCLE] System recovered after 1 RECYCLE (self-healing)
2026-01-30 16:15:07,359 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 3)
2026-01-30 16:15:12,366 INFO Check that MAIN_POWER is equal to 1
2026-01-30 16:15:12,366 INFO OK: read value = True
2026-01-30 16:15:12,366 INFO [MOCK] BIT report available after 5.8s
2026-01-30 16:15:12,398 INFO BIT report available after 0.0s
2026-01-30 16:15:12,399 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-01-30 16:15:12,399 INFO OK: read value = false
2026-01-30 16:15:12,399 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-01-30 16:15:12,399 WARNING CHECK ERROR: read value = true
2026-01-30 16:15:12,399 ERROR INTERFACE ERROR: Expected false, got true
2026-01-30 16:15:12,400 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-01-30 16:15:12,400 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-01-30 16:15:12,400 INFO OK: read value = false
2026-01-30 16:15:12,400 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-01-30 16:15:12,400 INFO OK: read value = false
2026-01-30 16:15:12,400 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-01-30 16:15:12,400 INFO OK: read value = false
2026-01-30 16:15:12,401 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-01-30 16:15:12,401 INFO OK: read value = false
2026-01-30 16:15:12,401 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-01-30 16:15:12,401 INFO OK: read value = false
2026-01-30 16:15:12,401 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-01-30 16:15:12,401 INFO OK: read value = false
2026-01-30 16:15:12,401 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-01-30 16:15:12,402 INFO OK: read value = false
2026-01-30 16:15:12,402 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-01-30 16:15:12,402 INFO OK: read value = false
2026-01-30 16:15:12,402 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-01-30 16:15:12,402 INFO OK: read value = false
2026-01-30 16:15:12,402 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-01-30 16:15:12,403 WARNING CHECK ERROR: read value = RDR_OK
2026-01-30 16:15:12,403 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-01-30 16:15:12,404 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-01-30 16:15:12,404 INFO [Run 2] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-01-30 16:15:12,404 INFO Known failures (HW setup): 2
2026-01-30 16:15:12,404 INFO [Run 2] All B6 LRU Status PASS (no B8 drill-down needed)
2026-01-30 16:15:12,404 INFO 0.0s remaining ...
2026-01-30 16:15:12,404 INFO [Run 2] Serial: 1 total, 0 errors, 1 fatal, 1 recycles
2026-01-30 16:15:12,405 WARNING Session: GRIFO_M_PBIT : Repetition 2 of 3
Total Step 16: Success 14 (87.50%), Failed 2 (12.50%),
2026-01-30 16:15:12,405 INFO Repetition 3 of 3
2026-01-30 16:15:12,405 DEBUG [MOCK] Serial statistics reset
2026-01-30 16:15:12,405 INFO The test operator is required to switch off the target and wait 3 seconds.
2026-01-30 16:15:12,405 INFO Set MAIN_POWER to False
2026-01-30 16:15:12,406 INFO [MOCK] Power OFF
2026-01-30 16:15:12,406 INFO [MOCK] 1553 Interface stopped
2026-01-30 16:15:17,421 INFO Check that MAIN_POWER is equal to 0
2026-01-30 16:15:17,421 INFO OK: read value = False
2026-01-30 16:15:20,432 INFO The test operator is required to switch on the target.
2026-01-30 16:15:20,432 INFO Set MAIN_POWER to True
2026-01-30 16:15:20,432 INFO [MOCK] Power ON
2026-01-30 16:15:20,432 INFO
====================================================================================================
[CRITICAL DEBUG] _initialize_field_values() CALLED
====================================================================================================
2026-01-30 16:15:20,432 INFO run_count = 4
2026-01-30 16:15:20,432 INFO SIMULATION_SCENARIO = 'mixed'
2026-01-30 16:15:20,432 INFO current_scenario = 'mixed'
2026-01-30 16:15:20,432 INFO _scenario_list = ['recycle_recovery_1', 'normal', 'random_failures']
2026-01-30 16:15:20,432 INFO [DEBUG] Entering MIXED MODE branch
2026-01-30 16:15:20,432 INFO [DEBUG] Mixed mode: scenario_index=0, selected scenario='recycle_recovery_1'
2026-01-30 16:15:20,432 INFO [DEBUG] About to call _log_scenario_info('recycle_recovery_1', 4, 3)
2026-01-30 16:15:20,438 INFO
2026-01-30 16:15:20,439 INFO ####################################################################################################
2026-01-30 16:15:20,439 INFO ####################################################################################################
2026-01-30 16:15:20,440 INFO ### RUN 4/3: RECYCLE SELF-HEALING (1 CYCLE)
2026-01-30 16:15:20,441 INFO ####################################################################################################
2026-01-30 16:15:20,441 INFO
2026-01-30 16:15:20,442 INFO SCENARIO: recycle_recovery_1
2026-01-30 16:15:20,442 INFO DESCRIPTION: Processor fails, then auto-recovers after 1 RECYCLE event
2026-01-30 16:15:20,443 INFO
2026-01-30 16:15:20,443 INFO EXPECTED FAILURES:
2026-01-30 16:15:20,443 INFO ✗ Initial: processor_status = FAIL
2026-01-30 16:15:20,443 INFO ✗ Serial: 1x RECYCLE event detected
2026-01-30 16:15:20,443 INFO
2026-01-30 16:15:20,445 INFO EXPECTED PASSES:
2026-01-30 16:15:20,445 INFO ✓ After RECYCLE: processor_status = PASS
2026-01-30 16:15:20,445 INFO ✓ Final: All systems OK
2026-01-30 16:15:20,445 INFO
2026-01-30 16:15:20,445 INFO NOTES: Simulates transient failure with fast self-healing. Test should detect RECYCLE and eventual recovery
2026-01-30 16:15:20,448 INFO
2026-01-30 16:15:20,448 INFO ####################################################################################################
2026-01-30 16:15:20,448 INFO ####################################################################################################
2026-01-30 16:15:20,448 INFO
2026-01-30 16:15:20,448 INFO [DEBUG] _log_scenario_info() completed
2026-01-30 16:15:20,449 INFO [MOCK APPLY] ⚠ RECYCLE scenario enabled: 1 cycle to recovery
2026-01-30 16:15:20,449 INFO [MOCK RECYCLE] Initial processor failure detected
2026-01-30 16:15:20,955 INFO [MOCK] Simulated RECYCLE event: %%F-10747-SP*: ***** RECYCLE!******
2026-01-30 16:15:21,267 INFO [MOCK RECYCLE] System recovered after 1 RECYCLE (self-healing)
2026-01-30 16:15:21,267 INFO [MOCK] 1553 Interface started - simulating BIT execution (Run 4)
2026-01-30 16:15:26,277 INFO Check that MAIN_POWER is equal to 1
2026-01-30 16:15:26,277 INFO OK: read value = True
2026-01-30 16:15:26,277 INFO [MOCK] BIT report available after 5.8s
2026-01-30 16:15:26,309 INFO BIT report available after 0.0s
2026-01-30 16:15:26,309 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_array_status is equal to false
2026-01-30 16:15:26,309 INFO OK: read value = false
2026-01-30 16:15:26,309 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status is equal to false
2026-01-30 16:15:26,309 WARNING CHECK ERROR: read value = true
2026-01-30 16:15:26,310 ERROR INTERFACE ERROR: Expected false, got true
2026-01-30 16:15:26,310 WARNING Known failure (ignored): radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pedestal_status
2026-01-30 16:15:26,310 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_pressurization_status is equal to false
2026-01-30 16:15:26,310 INFO OK: read value = false
2026-01-30 16:15:26,310 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_over_temperature_alarm is equal to false
2026-01-30 16:15:26,310 INFO OK: read value = false
2026-01-30 16:15:26,310 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_processor_status is equal to false
2026-01-30 16:15:26,310 INFO OK: read value = false
2026-01-30 16:15:26,311 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_receiver_status is equal to false
2026-01-30 16:15:26,311 INFO OK: read value = false
2026-01-30 16:15:26,311 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_rx_front_end_status is equal to false
2026-01-30 16:15:26,311 INFO OK: read value = false
2026-01-30 16:15:26,311 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_over_temperature_alarm is equal to false
2026-01-30 16:15:26,312 INFO OK: read value = false
2026-01-30 16:15:26,312 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_servoloop_status is equal to false
2026-01-30 16:15:26,312 INFO OK: read value = false
2026-01-30 16:15:26,312 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_over_temperature_alarm is equal to false
2026-01-30 16:15:26,312 INFO OK: read value = false
2026-01-30 16:15:26,312 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_trasmitter_status is equal to false
2026-01-30 16:15:26,312 INFO OK: read value = false
2026-01-30 16:15:26,313 INFO Check that B6_MsgRdrSettingsAndParametersTellback radar_health_status_and_bit_report_valid_RdrHealthStatusAndBitReport_radar_fail_status is equal to false
2026-01-30 16:15:26,313 WARNING CHECK ERROR: read value = RDR_OK
2026-01-30 16:15:26,313 ERROR INTERFACE ERROR: Expected false, got RDR_OK
2026-01-30 16:15:26,313 WARNING Radar fail status: Known failure (caused only by pedestal)
2026-01-30 16:15:26,313 INFO [Run 3] B6 LRU Status: 12 total, 10 pass, 0 fail, 2 known
2026-01-30 16:15:26,313 INFO Known failures (HW setup): 2
2026-01-30 16:15:26,314 INFO [Run 3] All B6 LRU Status PASS (no B8 drill-down needed)
2026-01-30 16:15:26,314 INFO 0.0s remaining ...
2026-01-30 16:15:26,314 INFO [Run 3] Serial: 1 total, 0 errors, 1 fatal, 1 recycles
2026-01-30 16:15:26,314 WARNING Session: GRIFO_M_PBIT : Repetition 3 of 3
Total Step 16: Success 14 (87.50%), Failed 2 (12.50%),
2026-01-30 16:15:26,314 INFO tgt_gen()
2026-01-30 16:15:26,337 INFO TgtMsg: 2 2
2026-01-30 16:15:26,337 INFO Tgt: 1 @ 1180
2026-01-30 16:15:26,337 INFO Check that B9 b9_t_num is between 1 and 2
2026-01-30 16:15:26,338 INFO OK: read value = 1
2026-01-30 16:15:26,338 INFO Check that B9 b9_t1_rng is between 1179 and 1186
2026-01-30 16:15:26,338 INFO OK: read value = 1180
2026-01-30 16:15:26,339 INFO Repetitions terminated.
2026-01-30 16:15:26,339 INFO [Report] Custom statistics data registered for PDF generation
2026-01-30 16:15:26,339 INFO ==========================================================================================
2026-01-30 16:15:26,339 INFO FINAL TEST STATISTICS SUMMARY
2026-01-30 16:15:26,339 INFO ==========================================================================================
2026-01-30 16:15:26,340 INFO Total Runs: 3
2026-01-30 16:15:26,340 INFO Successful: 3 (100.0%)
2026-01-30 16:15:26,340 INFO Failed: 0 (0.0%)
2026-01-30 16:15:26,340 INFO B6 Checks: 36 (Pass: 30, Fail: 0, Known: 6)
2026-01-30 16:15:26,341 INFO B8 Checks: 0 (Pass: 0, Fail: 0)
2026-01-30 16:15:26,341 INFO Serial: 3 messages (0 errors, 3 fatal, 3 recycles)
2026-01-30 16:15:26,341 INFO PBIT Timing: avg=0.03s, min=0.03s, max=0.03s, σ=0.00s
2026-01-30 16:15:26,341 INFO ==========================================================================================
2026-01-30 16:15:26,341 INFO Detailed statistics will be available in the PDF report
2026-01-30 16:15:26,341 INFO Exporting statistics to CSV: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260130_161526_statistics.csv
2026-01-30 16:15:26,344 INFO Statistics exported successfully to: C:\src\____GitProjects\SXXXXXXX_PyBusMonitor1553\__OLD\__TEST_GENOVA\GrifoAutomaticTestEnv\TestEnvironment\scripts\..\env\..\pdf_reports/GRIFO_M_PBIT\GRIFO_M_PBIT_20260130_161526_statistics.csv
2026-01-30 16:15:26,344 INFO Set MAIN_POWER to False
2026-01-30 16:15:26,345 INFO [MOCK] Power OFF
2026-01-30 16:15:26,346 INFO [MOCK] 1553 Interface stopped
2026-01-30 16:15:31,361 INFO Check that MAIN_POWER is equal to 0
2026-01-30 16:15:31,361 INFO OK: read value = False
2026-01-30 16:15:31,361 INFO [MOCK] Serial terminal disconnected
2026-01-30 16:15:31,361 INFO Stop Time: 2026-01-30 16:14:44.458330
2026-01-30 16:15:31,361 INFO Test execution time: 0:00:46.903474